1
|
Jin S, Lim JR, Yoon TH, Choi YR, Chun YM. Optimal immobilization position for conservative treatment of proximal humerus fractures by fracture type: a biomechanical cadaveric study. Sci Rep 2024; 14:13460. [PMID: 38862648 PMCID: PMC11166630 DOI: 10.1038/s41598-024-64326-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 06/07/2024] [Indexed: 06/13/2024] Open
Abstract
In conservative treatment for proximal humerus fractures (PHFs), the immobilization position of the affected arm should not be determined uniformly. The aim of this study is to investigate the optimal immobilization position for conservative treatment of different types of PHFs. We hypothesized that the optimal position minimizing the deforming force in PHFs depends on the fracture components involved. PHF models involving either the surgical neck (SN) or greater tuberosity (GT) were created using 12 fresh-frozen cadaveric shoulders. In the SN model, the deforming forces on the pectoralis major muscle were measured in full adduction by increasing external rotation. In the GT model, the deforming force of the supraspinatus muscle was measured in neutral rotation by decreasing abduction, and the deforming force of the infraspinatus muscle was measured in full adduction by increasing internal rotation, respectively. In the SN model, the deforming force of the pectoralis major muscle increased significantly with external rotation from full internal rotation to neutral rotation (P = 0.006), indicating that the arm should be placed in full internal rotation. In the GT model, the deforming force of the supraspinatus muscle increased significantly with adduction from 45° of abduction to full adduction (P = 0.006); the deforming force of the infraspinatus muscle increased significantly with internal rotation from neutral rotation to full internal rotation (P = 0.006). These findings should be considered when placing the arm in abduction and neutral rotation so as to minimize the deforming force by either the supra or infraspinatus muscle. In conservative treatment for PHFs, the affected arm should be placed in a position that minimizes the deforming force on the fracture components involved.
Collapse
Affiliation(s)
- Seokhwan Jin
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Korea
| | - Joon-Ryul Lim
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Korea
| | - Tae-Hwan Yoon
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Korea
| | - Yun-Rak Choi
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Korea
| | - Yong-Min Chun
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1, Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Korea.
| |
Collapse
|
2
|
Wang L, Lyu F, Rong J, Sun H, Li B, Liu J. Factors influencing shoulder stiffness after open reduction and internal fixation of proximal humeral fractures. Jt Dis Relat Surg 2024; 35:285-292. [PMID: 38727106 PMCID: PMC11128974 DOI: 10.52312/jdrs.2024.1529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 02/28/2024] [Indexed: 05/29/2024] Open
Abstract
OBJECTIVES The study aimed to investigate the factors associated with shoulder stiffness following open reduction and internal fixation (ORIF) of proximal humeral fractures. PATIENTS AND METHODS The retrospective study included a total of 151 patients who underwent ORIF of proximal humeral fractures between January 2016 and May 2021. Based on their shoulder joint motion at the latest follow-up, the patients were divided into two groups. The stiffness group (n=32; 8 males, 24 females; mean age: 62.4±9.3 years; range, 31 to 79 years), exhibited restricted shoulder forward flexion (<120°), limited arm lateral external rotation (<30°), and reduced back internal rotation below the L3 level. The remaining patients were included in the non-stiffness group (n=119; 52 males, 67 females; mean age: 56.4±13.4 years; range, 18 to 90 years). Various factors were examined to evaluate the association with shoulder stiffness following ORIF of proximal humeral fractures by multivariate unconditional logistic regression models. RESULTS The mean follow-up duration was 31.8±12.6 (range, 12 to 68) months. Based on the results of the multivariate regression analysis, it was found that high-energy injuries [compared to low-energy injuries; adjusted odds ratio (aOR)=7.706, 95% confidence interval (CI): 3.564-15.579, p<0.001], a time from injury to surgery longer than one week (compared to a time from injury to surgery equal to or less than one week; aOR=5.275, 95% CI: 1.7321-9.472, p=0.031), and a body mass index (BMI) >24.0 kg/m2 (compared to a BMI between 18.5 and 24.0 kg/m2 ; aOR=4.427, 95% CI: 1.671-11.722, p=0.023) were identified as risk factors for shoulder stiffness following ORIF of proximal humeral fractures. CONCLUSION High-energy injury, time from injury to surgery longer than one week, and BMI >24.0 kg/m2 were identified as independent risk factors for shoulder stiffness after proximal humeral fracture surgery, which should be treated with caution in clinical treatment.
Collapse
Affiliation(s)
| | | | | | | | | | - Jun Liu
- Department of Orthopedics, Tianjin Hospital, Tianjin, 300211 People's Republic of China.
| |
Collapse
|
3
|
Klute L, Henssler L, Schliemann B, Königshausen M, Weber N, Alt V, Kerschbaum M. Factors influencing choice of treatment for proximal humeral fractures elaborated in a Delphi consensus process. Arch Orthop Trauma Surg 2023; 143:7053-7061. [PMID: 37658856 PMCID: PMC10635939 DOI: 10.1007/s00402-023-05028-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 08/09/2023] [Indexed: 09/05/2023]
Abstract
INTRODUCTION Hitherto, the decision-making process for treatment of proximal humerus fractures (PHF) remains controversial, with no established or commonly used treatment regimens. Identifying fracture- and patient-related factors that influence treatment decisions is crucial for the development of such treatment algorithms. The objective of this study was to define a Delphi consensus of clinically relevant fracture- and patient-related factors of PHF for clinical application and scientific research. METHODS An online survey was conducted among an international panel of preselected experienced shoulder surgeons. An evidence-based list of fracture-related and patient-related factors affecting treatment outcome after PHF was generated and reviewed by the members of the committee through online surveys. The proposed factors were revised for definitions, and suggestions from the first round mentioned in the free text were included as possible factors in the second round of surveys. Consensus was defined as having at least a two-thirds majority agreement. RESULTS The Delphi consensus panel consisted of 18 shoulder surgeons who completed 2 rounds of online surveys. There was an agreement of more than two-thirds of the panel for three fracture-related factors affecting treatment decision in the case of PHF: head-split fracture, dislocated tuberosities, and fracture dislocation. Of all patient-related factors, a two-thirds consensus was reached for two factors: age and rotator cuff tear arthropathy. CONCLUSION This study successfully conducted a Delphi consensus on factors influencing decision-making in the treatment of proximal humeral fractures. The documented factors will be useful for clinical evaluation and scientific validation in future studies.
Collapse
Affiliation(s)
- Lisa Klute
- Department of Trauma Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - Leopold Henssler
- Department of Trauma Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - Benedikt Schliemann
- Department of Trauma, Hand and Reconstructive Surgery, Herz-Jesu Hospital, 48165, Münster, Germany
| | - Matthias Königshausen
- Department of Trauma Surgery and General Surgery, BG University Hospital Bergmannsheil, Ruhr University Bochum, Bürkle-de-La-Camp-Platz 1, 44789, Bochum, Germany
| | - Nadine Weber
- Department of Trauma Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - Volker Alt
- Department of Trauma Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - Maximilian Kerschbaum
- Department of Trauma Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany.
| |
Collapse
|
4
|
Lanzerath F, Loew M, Schnetzke M. Is there still a place for anatomic hemiarthroplasty in patients with high functional demands in primary, nonreconstructable proximal humeral fractures? A clinical and radiographic assessment. J Shoulder Elbow Surg 2023; 32:1909-1917. [PMID: 36907312 DOI: 10.1016/j.jse.2023.02.118] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 01/26/2023] [Accepted: 02/04/2023] [Indexed: 03/14/2023]
Abstract
BACKGROUND Vitality-threatening proximal humerus fractures often provide an indication for prosthetic treatment. We investigated the issue of how anatomic hemiprostheses perform in younger, functionally challenging patients with the use of a specific fracture stem and systematic tuberosity management in medium-term follow-up. METHODS Thirteen skeletally mature patients with a mean age of 64 ± 9 years and a minimum follow-up of 1 year after primary open-stem hemiarthroplasty for 3- and 4-part proximal humeral fractures were included. All patients were followed up regarding their clinical course. Radiologic follow-up included fracture classification, healing of tuberosities, proximal migration of the humeral head, evidence of stem loosening, and glenoid erosion. Functional follow-up included range of motion, pain, objective and subjective performance scores, complications, and return to sports rates. We statistically compared treatment success based on the Constant score between the cohort with proximal migration and the cohort with regular acromiohumeral distance by means of the Mann-Whitney U test. RESULTS After an average follow-up period of 4.8 years, satisfactory results were obtained. The absolute Constant-Murley score was 73.2 ± 12.4 points. The disabilities of the arm, shoulder, and hand score was 13.2 ± 13.0 points. Patients reported their mean subjective shoulder value as 86.6% ± 8.5%. Pain was reported as 1.1 ± 1.3 points on a visual analog scale. Flexion, abduction, and external rotation values were 138 ± 31°, 134 ± 34°, and 32 ± 17°, respectively. 84.6% of the referred tuberosities healed successfully. Proximal migration was observed in 38.5% of cases and was associated with worse Constant score results (P = .065). No patient showed signs of loosening. Mild glenoid erosion was apparent in 4 patients (30.8%). All patients who were interviewed and participated in sports before surgery were able to return to their primary sport after surgery and continued to do so during the final follow-up. CONCLUSIONS With narrow indications, use of a specific fracture stem and adequate tuberosity management, successful radiographic and functional results are presented after a mean follow-up of 4.8 years after hemiarthroplasty for primary nonreconstructable humeral head fractures. Accordingly, open-stem hemiarthroplasty appears to remain a possible alternative to reverse shoulder arthroplasty in younger, functionally challenging patients with primary 3- or 4-part proximal humeral fractures.
Collapse
Affiliation(s)
- Fabian Lanzerath
- Department of Shoulder and Elbow Surgery, ATOS Clinic Heidelberg, Heidelberg, Germany; Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany.
| | - Markus Loew
- Department of Shoulder and Elbow Surgery, ATOS Clinic Heidelberg, Heidelberg, Germany
| | - Marc Schnetzke
- Department of Shoulder and Elbow Surgery, ATOS Clinic Heidelberg, Heidelberg, Germany
| |
Collapse
|
5
|
Wu Z, Shen W. An updated systematic review and meta‑analysis comparing deltoid‑split approach with deltopectoral approach for proximal humerus fractures. Exp Ther Med 2023; 25:296. [PMID: 37229316 PMCID: PMC10203753 DOI: 10.3892/etm.2023.11995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 03/15/2023] [Indexed: 05/27/2023] Open
Abstract
The present review and meta-analysis aimed to summarize the currently available data and to compare the important clinical and functional outcomes in patients with proximal humerus fractures who were treated using deltoid split (DS) or deltopectoral (DP) surgical approaches. The PubMed, EMBASE, Scopus and Cochrane Central Register of Controlled Trials databases were systematically searched for randomized controlled trials or observational studies that reported functional outcome data of patients with fracture of proximal humerus who were surgically treated using DS and DP approaches. A total of 14 studies were included in the present meta-analysis. The duration of surgery [min; weighted mean difference (WMD), -16.44; 95% CI, -(25.25-7.63)], amount of blood loss [ml; WMD, -57.99; 95% CI, -(102.74-13.23)] and time to bone union [weeks WMD, -1.66; 95% CI, -(2.30-1.02)] was comparatively lower in patients that underwent DS. There were no statistically significant differences in the pain and quality of life scores, range of movement and risk of complications between the DS and the DP groups. Patients in the DS group had improved shoulder function and constant shoulder score (CSS) at 3 months post-surgery (WMD, 6.36; 95% CI, 1.06-11.65). No differences were observed between the two groups in terms of CSS and disabilities of the arm, shoulder and hand scores at 12 and 24 months post-operatively. The activity of daily living (ADL) score was significantly improved in the DS group at 3 (WMD, 1.23; 95% CI, 0.40-2.06), 6 (WMD, 0.99; 95% CI, 0.72-1.25) and 12 months (WMD, 0.83; 95% CI, 0.18-1.47) after the surgery. The present results suggested that DS and DP surgical approaches were associated with similar clinical outcomes. The DS approach was associated with certain perioperative benefits, as well as reduced time to bone union, improved shoulder function in the early postoperative period and improved ADL scores. These benefits may be considered while choosing between these two surgical approaches.
Collapse
Affiliation(s)
- Zhe Wu
- Department of Orthopedics, Huzhou Central Hospital, Affiliated Central Hospital Huzhou University, Huzhou, Zhejiang 313000, P.R. China
| | - Wenting Shen
- Department of Orthopedics, Huzhou Central Hospital, Affiliated Central Hospital Huzhou University, Huzhou, Zhejiang 313000, P.R. China
| |
Collapse
|
6
|
Lei M, Zhang M, Luo N, Ye J, Lin F, Chen Y, Chen J, Xiao M. The clinical performance of ultra-low-dose shoulder CT scans: The assessment on image and physical 3D printing models. PLoS One 2022; 17:e0275297. [PMID: 36155982 PMCID: PMC9512178 DOI: 10.1371/journal.pone.0275297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 09/13/2022] [Indexed: 11/19/2022] Open
Abstract
Objectives Evaluation of the clinical performance of ultra-low-dose computed tomography (CT) images of the shoulder joint on image-based diagnosis and three-dimensional (3D) printing surgical planning. Materials and methods A total of 93 patients with displaced shoulder fractures were randomly divided into standard-dose, low-dose, and ultra-low-dose groups. Three-dimensional printing models of all patients’ shoulder joints were fabricated. The subjective image quality and 3D-printing model were evaluated by two senior orthopedic surgeons who were blinded to any scanning setting. A 3-point scale system was used to quantitatively assess the image quality and 3D printing model, where more than 2 points meant adequate level for clinical application. Results Compared with the standard dose protocol, ultra-low-dose technique reduced the radiation dose by 99.29% without loss of key image quality of fracture pattern. Regarding the subjective image quality, the assessment scores for groups of standard, low, and ultra-low doses were 3.00, 2.76, 2.00 points on scapula and humerus, and 3.00, 2.73, 2.44 points on clavicle. Scores of the three groups for the assessment of 3D printing models were 3.00, 2.80, 1.34 on scapula and humerus, and 3.00, 2.90, 2.06 on clavicle. In the ultra-low-dose group, 24 out of 33 (72.7%) 3D printing models of scapula and humerus received lower than 2 points of the evaluation score, while nearly 94% of the clavicle models reached the adequate level. Conclusion An ultra-low-dose protocol is adequate for the diagnosis of either displaced or non-displaced fractures of the shoulder joint even though minor flaws of images are present. Three-dimensional printing models of shoulder joints created from ultra-low-dose CT scans can be used for surgical planning at specific bone like the clavicle but perform insufficiently in the overall surgical planning for shoulder injuries due to the significant geometric flaws.
Collapse
Affiliation(s)
- Ming Lei
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Meng Zhang
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Niyuan Luo
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Jingzhi Ye
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Fenghuan Lin
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Yanxia Chen
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Jun Chen
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
| | - Mengqiang Xiao
- Department of Imaging, Zhuhai Hospital Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai, China
- * E-mail:
| |
Collapse
|
7
|
Mohan K, Hintze JM, Morrissey D, Molony D. Incidence of avascular necrosis following biceps tenodesis during proximal humerus open reduction and internal fixation. Acta Orthop Belg 2021. [DOI: 10.52628/87.2.20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Avascular necrosis (AVN) may occur in up to 77% of proximal humeral fractures and can cause fixation failure. Risk factors include fracture position, calcar length and medial hinge integrity. We routinely perform intra-articular biceps tenotomy with tenodesis at the level of pectoralis major to facilitate fragment identification and potentially ameliorate post-operative pain relief. Concern exists that tenotomising the biceps damages the adjacent arcuate artery, potentially increasing the rate of AVN. The purpose of this study was to evaluate whether biceps tenodesis is associated with an increased risk of radiographically evident humeral head AVN.
61 fractures surgically treated over a 52-month period were retrospectively reviewed and radiographically assessed in accordance with Neer’s classification, calcar-length and medial hinge integrity.
40, 20 and 1 were four-, three- and two-part fractures respectively. 37 had a calcar-length less than 8mm and 26 suffered loss of the medial hinge. The median radiographic follow-up was 23 months. There was radiographic evidence of humeral head AVN in only one case, comparing favourably to rates quoted in current literature.
In our experience, intra-articular biceps tenotomy with the deltopectoral approach was thus not associated with a significantly increased risk of humeral head AVN, even in complex four-part fractures.
Collapse
|
8
|
Wilson WT, Pickup AR, Findlay H, Gupta S, Mahendra A. Stabilisation of pathological humerus fractures using cement augmented plating: A case series. J Clin Orthop Trauma 2021; 15:93-98. [PMID: 33680826 PMCID: PMC7919932 DOI: 10.1016/j.jcot.2020.10.028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/07/2020] [Accepted: 10/13/2020] [Indexed: 10/23/2022] Open
Abstract
The humerus is the second most common long bone for metastatic tumours. These lesions result in weakened bone architecture and increased fracture risk with patients suffering pain, loss of function and diminished quality of life, often when life expectancy is short. Fractures or impending fractures require surgical stabilisation to relieve pain and restore function for the remainder of the patient's life without the need for further surgery. Conventional management of these lesions in the humerus is intramedullary nailing, however there are issues with this technique, particularly regarding rigidity of fixation. Advances in contoured locking plates have led to the development of different stabilisation techniques. The preferred technique in our regional oncology unit is curettage of the tumour and plating, augmented with cement to fill the defect and restore the structural morphology. In this case series we evaluate the survivorship of the construct and the clinical outcomes in patients who had an established or prospective pathological humeral fracture treated with curettage and cement augmented plating, since 2010. We identified 19 patients; 17 had metastasis and 2 myeloma of whom 15 had established fractures and four impending. The mean age at surgery was 69 years (51-86), and mean time since surgery 3.2 years. Overall mean follow up time was 20 months with 14 patients deceased and 5 surviving. There was 100% survivorship of the construct with no mechanical failures and no re-operations. There were no post-operative wound complications. Excellent early pain control was achieved in 18 patients with one experiencing pain controlled by analgesia. Function was assessed using Toronto Extremity Salvage Score (TESS) and was satisfactory; mean 79/100 (range 72-85). Cement augmented plating for pathological humerus fractures is a suitable alternative to intramedullary nailing and addresses several of the concerns with that technique. It provides immediate rigidity and allows early unrestricted function.
Collapse
Affiliation(s)
- William T. Wilson
- Department of Orthopaedic Oncology, Glasgow Royal Infirmary, Glasgow, UK
| | - Alan R. Pickup
- Department of Orthopaedic Oncology, Glasgow Royal Infirmary, Glasgow, UK
| | - Helen Findlay
- Department of Orthopaedic Oncology, Glasgow Royal Infirmary, Glasgow, UK
| | - Sanjay Gupta
- Department of Orthopaedic Oncology, Glasgow Royal Infirmary, Glasgow, UK
| | - Ashish Mahendra
- Department of Orthopaedic Oncology, Glasgow Royal Infirmary, Glasgow, UK
| |
Collapse
|
9
|
Bougher H, Buttner P, Smith J, Banks J, Na HS, Forrestal D, Heal C. Interobserver and intraobserver agreement of three-dimensionally printed models for the classification of proximal humeral fractures. JSES Int 2021; 5:198-204. [PMID: 33681838 PMCID: PMC7910723 DOI: 10.1016/j.jseint.2020.10.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Hypothesis This study aimed to examine whether three-dimensionally printed models (3D models) could improve interobserver and intraobserver agreement when classifying proximal humeral fractures (PHFs) using the Neer system. We hypothesized that 3D models would improve interobserver and intraobserver agreement compared with x-ray, two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) and that agreement using 3D models would be higher for registrars than for consultants. Methods Thirty consecutive PHF images were selected from a state-wide database and classified by fourteen observers. Each imaging modality (x-ray, 2D CT, 3D CT, 3D models) was grouped and presented in a randomly allocated sequence on two separate occasions. Interobserver and intraobserver agreements were quantified with kappa values (κ), percentage agreement, and 95% confidence intervals (CIs). Results Seven orthopedic registrars and seven orthopedic consultants classified 30 fractures on one occasion (interobserver). Four registrars and three consultants additionally completed classification on a second occasion (intraobserver). Interobserver agreement was greater with 3D models than with x-ray (κ = 0.47, CI: 0.44-0.50, 66.5%, CI: 64.6-68.4% and κ = 0.29, CI: 0.26-0.31, 57.2%, CI: 55.1-59.3%, respectively), 2D CT (κ = 0.30, CI: 0.27-0.33, 57.8%, CI: 55.5-60.2%), and 3D CT (κ = 0.35, CI: 0.33-0.38, 58.8%, CI: 56.7-60.9%). Intraobserver agreement appeared higher for 3D models than for other modalities; however, results were not significant. There were no differences in interobserver or intraobserver agreement between registrars and consultants. Conclusion Three-dimensionally printed models improved interobserver agreement in the classification of PHFs using the Neer system. This has potential implications for using 3D models for surgical planning and teaching.
Collapse
Affiliation(s)
- Hannah Bougher
- James Cook University, Mackay Clinical School, Mackay, QLD, Australia
| | | | | | - Jennifer Banks
- James Cook University, Mackay Clinical School, Mackay, QLD, Australia
| | - Hyun Su Na
- Mackay Base Hospital, Mackay, QLD, Australia
| | - David Forrestal
- Queensland University of Technology, Brisbane City, QLD, Australia
| | - Clare Heal
- James Cook University, Mackay Clinical School, Mackay, QLD, Australia
| |
Collapse
|
10
|
Chan JM, Kahlenberg C, Gadinsky NE, Lorich DG, Dines JS. Arthroscopic-Assisted Removal of Proximal Humerus Locking Plates With Capsular Release Significantly Improves Range of Motion and Function. Arthrosc Sports Med Rehabil 2021; 3:e211-e217. [PMID: 33615267 PMCID: PMC7879204 DOI: 10.1016/j.asmr.2020.09.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Accepted: 09/13/2020] [Indexed: 11/29/2022] Open
Abstract
Purpose To investigate the clinical outcomes following the arthroscopic removal of proximal humerus locking plates for symptomatic hardware after open reduction and internal fixation (ORIF) of proximal humerus fractures. Methods Patients who underwent arthroscopic removal of hardware (ROH) with capsular release due to pain and/or immobility after receiving locking plates to treat proximal humerus fractures from 2009 to 2016 were identified. Operative and clinic records were reviewed to obtain demographic information, concomitant procedures during ROH, and pre- and postoperative active shoulder range of motion. Postoperative patient-reported outcomes included the QuickDASH, PROMIS Pain Intensity, Constant, and University of California, Los Angeles shoulder rating scale. Results In total, 88 patients were included. Patients were evaluated at a minimum of 6 weeks postoperatively after ROH. Patients with pre- and postoperative active range of motion values demonstrated significant improvements in mean forward elevation (n = 69; 78.4%; 115.1° to 152.1°, P < .001), abduction (n = 29; 33.0%; 70.9° to 138.7°, P < .001), external rotation (n = 49; 55.7%; 43.7° to 58.6°, P = .012), and internal rotation (n = 45; 51.1%; 25.7° to 61.9°, P < .001). Patients also reported positive patient-reported scores, including the QuickDASH (4.1 ± 7.8), PROMIS Pain Intensity (3.5 ± 0.9), Constant (84.6 ± 10.7), and University of California, Los Angeles shoulder rating scale (33 ± 2.9), which were measured 70.6 ± 26.6 months postoperatively. There were no surgical complications, no arthroscopic cases were converted to open, but 2 reported refractures (2.3%). Conclusions Arthroscopic-assisted removal of proximal humerus locking plates significantly improves motion and function while allowing for management of concomitant shoulder pathology and potentially avoiding open surgery complications. Given that patients undergoing this procedure frequently have multiple comorbidities, arthroscopic-assisted removal with smaller incisions may minimize risks while restoring shoulder mobility. Therefore, arthroscopic ROH for patients experiencing symptomatic hardware after ORIF is recommended. Level of Evidence Level IV, therapeutic case series.
Collapse
Affiliation(s)
- Justin M Chan
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Cynthia Kahlenberg
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Naomi E Gadinsky
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Dean G Lorich
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Joshua S Dines
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
11
|
MRI evaluation of axillary neurovascular bundle: Implications for minimally invasive proximal humerus fracture fixation. JSES Int 2021; 5:205-211. [PMID: 33681839 PMCID: PMC7910741 DOI: 10.1016/j.jseint.2020.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background Percutaneous fixation of proximal humeral fractures places the axillary nerve and posterior humeral circumflex artery at risk for injury. Safe operative zones for the axillary nerve are described based on external measurements from anatomic landmarks, but no study to date has incorporated advanced imaging to help guide surgical procedures in the region of the axillary neurovascular bundle (ANVB). We sought to define the location and trajectory of the ANVB in relation to osseous landmarks using magnetic resonance imaging (MRI) measurements. Methods Retrospective review of 750 consecutive MRI studies was performed with 55 imaging studies meeting inclusion criteria for patient positioning, image alignment, and quality. Five measurements were performed including the distance from mid-lateral acromion to lateral ANVB, mid-lateral acromion to medial ANVB, greater tuberosity to lateral ANVB, vertical distance between inferior anatomic neck and lateral ANVB, and angle the ANVB crosses the humerus. Height, gender, and age were recorded. Analysis was performed using ANOVA and Pearson correlation tests. Results The lateral ANVB was below the inferior articular margin of the humeral head by an average of 12.9 ± 3.9 mm and within a 22 mm window. It was an average of 57.4 ± 5.1 mm from the lateral mid-acromion, and 34.7 ± 4.3 mm below the greater tuberosity. The angle formed by the ANVB crossing the humerus averaged 19.5 ± 3.9 degrees upward from medial to lateral. Height and gender directly impacted measurements. Conclusions The use of the inferior humeral head articular margin provides a radiographic landmark to aid intraoperative lateral ANVB assessment which may be helpful during percutaneous fracture fixation.
Collapse
|
12
|
Zhang V, Koa B, Borja AJ, Padmanhabhan S, Bhattaru A, Raynor WY, Rojulpote C, Seraj SM, Werner TJ, Rajapakse C, Alavi A, Revheim ME. Diagnosis and Monitoring of Osteoporosis with Total-Body 18F-Sodium Fluoride-PET/CT. PET Clin 2020; 15:487-496. [PMID: 32768370 DOI: 10.1016/j.cpet.2020.06.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
In recent years, 18F-Sodium Fluoride (NaF)-PET/CT has seen its role in the detection and management of osteoporosis increase. This article reviews the extent of this application in the literature, its efficacy compared with other comparable imaging tools, and how total-body PET/CT combined with global disease assessment can revolutionize measurement of total osteoporotic disease activity. NaF-PET/CT eventually can be the modality of choice for metabolic bone disorders, especially with these advances in technology and computation.
Collapse
Affiliation(s)
- Vincent Zhang
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Benjamin Koa
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA; Drexel University College of Medicine, Philadelphia, PA, USA
| | - Austin J Borja
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA; Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| | - Sayuri Padmanhabhan
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Abhijit Bhattaru
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - William Y Raynor
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA; Drexel University College of Medicine, Philadelphia, PA, USA
| | - Chaitanya Rojulpote
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA; Department of Internal Medicine, The Wright Center for Graduate Medical Education, Scranton, PA, USA
| | | | - Thomas J Werner
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Chamith Rajapakse
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Abass Alavi
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA.
| | - Mona-Elisabeth Revheim
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA; Division of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway; Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
13
|
Branca Vergano L, Corsini G, Monesi M. Long head of biceps in proximal fractures of the humerus: an underestimated problem? ACTA BIO-MEDICA : ATENEI PARMENSIS 2020; 91:69-78. [PMID: 32555078 PMCID: PMC7944844 DOI: 10.23750/abm.v91i4-s.9634] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 04/28/2020] [Indexed: 11/25/2022]
Abstract
Background and aim of the work: The long head of biceps (LHB) is one of the tendons of the rotator cuff that runs strictly close to the humeral head. In case of pathology, it can be responsible for pain and shoulder impairment: in such cases, surgical options include tenotomy or tenodesis. The management of LHB along with surgery of the rotator cuff or during shoulder prosthetic replacement has been widely discussed in the literature. Conversely, the possibility of acute impingement and incarceration of LHB in proximal humerus fractures, as well as its role in shoulder pain in outcomes of these fractures, has been poorly considered. Methods: The following aspects in the literature on LHB and proximal humerus fractures have been analysed: its management during fixation of fractures, the possibility of interference of the tendon with reduction of fractures or dislocations of the shoulder and its possible role in chronic pain after fixation of proximal humerus fractures. Results: LHB can be an obstacle in the reduction of fractures, dislocations and fracture-dislocations. Only a few papers take into account acute surgery to LHB (tenotomy or tenodesis); most of the studies on fixation of proximal humerus fractures simply ignore the problem of LHB. The tendon can be a source of pain and a cause of disability in sequelae of these fractures. Conclusions: LHB should be taken into consideration both in the acute phase of fractures of the proximal humerus and in the outcomes. Other studies are needed to better understand its optimal management during fracture surgery. (www.actabiomedica.it)
Collapse
Affiliation(s)
| | | | - Mauro Monesi
- Ortopedia e traumatologia Ospedale M. Bufalini, Cesena (FC).
| |
Collapse
|
14
|
Peters PM, Plachel F, Danzinger V, Novi M, Märdian S, Scheibel M, Moroder P. Clinical and Radiographic Outcomes After Surgical Treatment of Proximal Humeral Fractures with Head-Split Component. J Bone Joint Surg Am 2020; 102:68-75. [PMID: 31596803 DOI: 10.2106/jbjs.19.00320] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Head-split fractures are a subgroup of proximal humeral fractures in which the fracture line affects the articular surface. Limited data are available regarding outcomes and risk factors for failure following surgical treatment of this rare fracture type. METHODS Of 45 patients with head-split fractures identified, a total of 30 (67%) were included in this retrospective study, with a mean follow-up of 49 ± 18 months (range, 12 to 83 months). Of those 30, 24 were treated with open reduction and internal fixation (ORIF), 4 with reverse total shoulder arthroplasty (RTSA), and 2 with hemiarthroplasty. Subjective Shoulder Value, Simple Shoulder Test, Constant score, and biplanar radiographs were assessed. Fracture pattern, quality of reduction, eventual complications, revision procedures, and clinical failure (adjusted Constant score < 40) were analyzed, and risk factors for failure were calculated. RESULTS The overall complication rate was 83% (ORIF: 21 of 24 [88%]; RTSA: 3 of 4 [75%]; and hemiarthroplasty: 1 of 2 [50%]). The most common complications following ORIF were humeral head osteonecrosis (42%), malunion of the lesser tuberosity (33%), and screw protrusion (29%), whereas all complications following RTSA were related to tuberosity problems. Revision was performed in 7 of 24 (29%) of initial ORIF patients, and no revisions were performed in RTSA or hemiarthroplasty patients. Four patients (17%) who underwent primary ORIF underwent conversion to RTSA, and 3 patients (12.5%) had screw removal due to penetration. The overall clinical failure rate was 50% (ORIF: 12 of 24 [50%]; RTSA: 1 of 4 [25%]; and hemiarthroplasty: 2 of 2 [100%]). No significant association was found between preoperative factors and clinical failure. ORIF and primary RTSA showed higher average clinical outcome scores than primary hemiarthroplasty and secondary RTSA. In general, patients who required revision had worse Subjective Shoulder Value (p = 0.014), Simple Shoulder Test (p = 0.028), and adjusted Constant scores (p = 0.069). CONCLUSIONS Head-split fractures of the humerus treated with ORIF showed high complication and revision rates. RTSA resulted in comparable clinical outcomes and complication rates; however, the complications associated with RTSA were mostly related to tuberosity problems, which in this small series did not require revision. Therefore, RTSA may be the most predictable treatment option for head-split fractures in elderly patients. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete list of levels of evidence.
Collapse
Affiliation(s)
- Paulina-Maria Peters
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany
| | - Fabian Plachel
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany.,Institute of Tendon and Bone Regeneration, Paracelsus Medical University, Salzburg, Austria
| | - Victor Danzinger
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany
| | - Michele Novi
- Azienda Ospedaliera Universitaria Pisana, Università di Pisa, Pisa, Italy
| | - Sven Märdian
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany
| | - Markus Scheibel
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany.,Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Philipp Moroder
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany
| |
Collapse
|
15
|
Shaw L, Hong CK, Kuan FC, Lin CL, Wang PH, Su WR. The incidence of occult and missed surgical neck fractures in patients with isolated greater tuberosity fracture of the proximal humerus. BMC Musculoskelet Disord 2019; 20:482. [PMID: 31656189 PMCID: PMC6815442 DOI: 10.1186/s12891-019-2810-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2019] [Accepted: 08/30/2019] [Indexed: 11/29/2022] Open
Abstract
Background Occult and missed surgical neck fractures can be found in patients diagnosed with isolated greater tuberosity (GT) fracture during the follow up period. The purpose of this study was to retrospectively assess the incidence rate of occult and missed surgical neck fractures in those initially diagnosed with isolated GT fracture. Methods Records of patients diagnosed as having an isolated GT fracture were retrieved from a database in a medical center. Two senior orthopedic surgeons blindly reviewed all images of these patients three times to classify GT fracture types (split, avulsion and depression types), and recorded any surgical neck fractures found. Then a meeting was help to confirm the fracture types and presence of surgical neck fracture. Results Occult surgical neck fractures were found in 5 out of 68 (7.4%) patients, whereas missed surgical neck fractures were found in 3 out of 68 (4.4%) patients. In total, 32 patients had split type GT fracture, 32 had avulsion type and 4 had depression type. For those with occult surgical neck fractures, 7 had the split type GT fracture, while the remaining one had the avulsion type. Although the proportion of occult surgical neck fracture was higher in the split-type GT fracture (21.9%) than in the avulsion-type GT fracture (3.1%), the difference was not statistically significant (p = 0.056). Conclusion Occult humeral surgical neck fractures occurred in 7.4% of isolated greater tuberosity fractures after re-evaluation, while missed humeral surgical neck fractures occurred in 4.4%.
Collapse
Affiliation(s)
- Leo Shaw
- Department of Medical Education, Taichung Veteran's General Hospital, Taichung, Taiwan
| | - Chih-Kai Hong
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, No.138, Sheng-Li Road, Tainan City, Taiwan, 70428
| | - Fa-Chuan Kuan
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, No.138, Sheng-Li Road, Tainan City, Taiwan, 70428
| | - Cheng-Li Lin
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, No.138, Sheng-Li Road, Tainan City, Taiwan, 70428
| | - Ping-Hui Wang
- Department of Orthopaedic Surgery, Chi-Mei Medical Center, Tainan, Taiwan
| | - Wei-Ren Su
- Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, No.138, Sheng-Li Road, Tainan City, Taiwan, 70428. .,Skeleton Materials and Bio-compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
| |
Collapse
|
16
|
Nelson G, Brown C, Liu RW. No incidence of glenohumeral joint dislocation in a review of 220 paediatric proximal humerus fractures. J Child Orthop 2018; 12:493-496. [PMID: 30294374 PMCID: PMC6169566 DOI: 10.1302/1863-2548.12.180075] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
PURPOSE Proximal humerus fractures in adults are approached with a high suspicion for potential associated glenohumeral dislocation. Axillary views of the shoulder can be painful and possibly even lead to dynamic angulation of the proximal humerus fracture. The incidence of associated glenohumeral dislocation in the paediatric population is unclear and it would be useful to determine whether children with proximal humerus fracture require specific axillary view imaging to rule out dislocation. METHODS We retrospectively reviewed 220 proximal humerus fractures in 218 total children. Imaging and follow-up clinic notes were reviewed for potential glenohumeral dislocation. RESULTS Average patient age was 9.8 years SD 3.8 with 55% of the patients male and a wide variety of mechanisms of injury. None of the 220 fractures evaluated showed radiographic evidence of a shoulder dislocation, and all 218 children had a follow-up appointment at least 21 days after the injury without any clinical concern of a missed shoulder dislocation. CONCLUSION No paediatric patients presenting with proximal humerus fractures had a corresponding glenohumeral joint dislocation in our relatively large series. We recommend obtaining this additional imaging only in cases with higher energy mechanisms, if there is suspicion of subluxation or dislocation on anteroposterior and scapular-Y views or if there is clinical concern. LEVEL OF EVIDENCE Level III Diagnostic.
Collapse
Affiliation(s)
- G. Nelson
- Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
| | - C. Brown
- Department of Orthopaedics, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA
| | - R. W. Liu
- Division of Pediatric Orthopedic Surgery, Case Western Reserve University, Rainbow Babies and Children’s Hospital, Cleveland, Ohio, USA, Correspondence should be sent to R. W. Liu, Division of Pediatric Orthopedic Surgery, Case Western Reserve University, Rainbow Babies and Children’s Hospital, 11100 Euclid Avenue, RBC 6081, Cleveland, Ohio 44106, United States. E-mail:
| |
Collapse
|
17
|
Fai LY, Hin CAP, Cheong KJJS, Bon KK, Ho FJC. A Novel Closed Method to Retrieve Broken Teflon Tube during Intramedullary Nailing in Proximal Humeral Fracture. JOURNAL OF ORTHOPAEDICS, TRAUMA AND REHABILITATION 2017. [DOI: 10.1016/j.jotr.2016.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Broken medullary tubes have been used for intramedullary (IM) nailing of femoral and tibial fractures. In these reported cases, fragments of the medullary tube were retrieved by opening the fracture sites or left in situ, which might jeopardize periosteal blood supply. We herein present the case of a 58-year-old woman who underwent IM nailing for proximal humeral fracture, which was complicated by breakage of the medullary tube intraoperatively. Different instruments including guide rods, straight forceps, and cement extract hook were used to retrieve the retained fragments from the medullary canal, but these attempts were unsuccessful. Finally, the fragments were successfully removed using an anterior cruciate ligament (ACL) ENDOBUTTON depth gauge. This case highlights that medullary tubes can break during humeral IM nailing, which could be minimized by ensuring integrity of the medullary tube prior to surgery and disposing medullary tubes with more than 100 exposures. A novel method of using ACL ENDOBUTTON depth gauge to retrieve retained tube fragments is recommended because of its long and slim design.
Collapse
Affiliation(s)
- Lau Yuk Fai
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, China
| | - Chan Alexander Pak Hin
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, China
| | | | - Kwok Ka Bon
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, China
| | - Fan Jason Chi Ho
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, China
| |
Collapse
|
18
|
Abstract
Proximal humerus fractures (PHFs) are common injuries seen mostly in elderly patients. Although nonoperative management is acceptable for most patients, surgical fixation is often advocated for younger patients or active, elderly patients with reconstructable fractures. A variety of fixation methods exist: percutaneous pinning, open reduction and internal fixation with locking plates, and intramedullary nailing are viable options. Modern intramedullary nails serve as excellent options for the fixation of many operative PHFs. In this Supplemental Digital Content 1 (see video, http://links.lww.com/JOT/A27), we discuss the care of a 63-year-old active, healthy female with a 2-part PHF. The details of fixation of PHFs using a straight intramedullary nail are included, as well as a relevant literature review and description of our postoperative rehabilitation protocol.
Collapse
|
19
|
Goch AM, Christiano A, Konda SR, Leucht P, Egol KA. Operative repair of proximal humerus fractures in septuagenarians and octogenarians: Does chronologic age matter? J Clin Orthop Trauma 2017; 8:50-53. [PMID: 28360497 PMCID: PMC5359506 DOI: 10.1016/j.jcot.2017.01.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 01/03/2017] [Accepted: 01/14/2017] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND With an expected doubling of the geriatric population within the next thirty years it is becoming increasingly important to determine who among the elderly population benefit from orthopaedic interventions. This study assesses post-operative outcomes in patients aged seventy or greater who sustained a proximal humerus fracture and were treated surgically as compared to a younger geriatric cohort to determine if there is a chronologic age after which post-operative outcomes significantly decline. METHODS A retrospective chart review was conducted for 201 patients who sustained fractures of the proximal humerus (OTA 11A-C) and were treated operatively by open reduction and internal fixation. Data from 132 independent, active patients aged fifty-five or older was identified and analyzed. Forty-seven patients age 70 or older were compared to 78 patients aged 55-69. Average length of follow-up was 19.5 months. All complications were recorded. Univariate and multivariate analysis was conducted to assess for differences between groups. RESULTS 95% of patients achieved fracture union within 6 months. No significant differences were found between cohorts with regard to gender, fracture severity, or CCI (p = 0.197, p = 0.276, p = 0.084, respectively). Functional outcome scores, shoulder range of motion, and complications rates for patients aged 70 and older were not significantly different from patients aged 55-69. There were 10 complications in the older elderly cohort (21%), 6 of which required re-operation and 13 complications in the young elderly cohort (17%), 8 of which required re-operation. CONCLUSIONS Operative fracture repair using locked plating of the proximal humerus in septuagenarians and octogenarians can provide for excellent long-term outcomes in appropriately selected patients. These patients tend to have long term functional outcome scores, post-operative range of motion, and complication rates that are comparable to younger geriatric patients. Physicians should not exclude patients for repair of proximal humerus fractures based on chronological age cutoffs.
Collapse
|
20
|
Liu YW, Wei XE, Kuang Y, Zheng YX, Gu XF, Zhan HS, Shi YY. Open vs. closed reduction combined with minimally invasive plate osteosynthesis in humeral fractures. MINIM INVASIV THER 2016; 25:215-21. [PMID: 27266386 DOI: 10.3109/13645706.2016.1151891] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Aim To explore a more effective surgical procedure, the outcomes of closed manipulative reduction (CMR) combined with minimally invasive plate osteosynthesis (MIPO) and conventional open reduction and internal fixation (ORIF) for treating proximal humeral fractures were compared. Material and methods In a retrospective study of patients operated for humerus shaft fractures from April 2008 to July 2011, the outcomes of 33 patients treated with CMR/MIPO were compared with the outcomes of 42 patients treated with ORIF. The fractures were classified, and the incision length, blood transfusion, operating time, as well as the VAS (Visual Analog Scale) pain scores were analyzed. The neck-shaft angles of the proximal humerus were detected, and the postoperative function of the shoulder was evaluated. Results The mean values of incision length, blood transfusion, and VAS pain scores at the 1st and 3rd day after CMR/MIPO and operation time were lower than that of ORIF. The postoperative radiographs verified good position of all screws and satisfactory bone fracture reduction in both groups. Meanwhile, in the ORIF group, nonunion (three cases) and humeral head necrosis (four cases) were detected. Conclusions The MR/MIPO technique showed smaller incisions, easier operation, less blood transfusion and more effective recovery of shoulder joint function for treating proximal humeral fractures than ORIF.
Collapse
Affiliation(s)
- Yin-Wen Liu
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| | - Xiao-En Wei
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| | - Yong Kuang
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| | - Yu-Xin Zheng
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| | - Xin-Feng Gu
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| | - Hong-Sheng Zhan
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| | - Yin-Yu Shi
- a Orthopedic Department , Shuguang Hospital affiliated to Shanghai TCM University , Shanghai , China
| |
Collapse
|
21
|
Kubosch EJ, Bernstein A, Wolf L, Fretwurst T, Nelson K, Schmal H. Clinical trial and in-vitro study comparing the efficacy of treating bony lesions with allografts versus synthetic or highly-processed xenogeneic bone grafts. BMC Musculoskelet Disord 2016; 17:77. [PMID: 26873750 PMCID: PMC4752776 DOI: 10.1186/s12891-016-0930-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Accepted: 02/06/2016] [Indexed: 12/20/2022] Open
Abstract
Background Our study aim was to compare allogeneic cancellous bone (ACB) and synthetic or highly-processed xenogeneic bone substitutes (SBS) in the treatment of skeletal defects in orthopedic surgery. Methods 232 patients treated for bony lesions with ACB (n = 116) or SBS (n = 116) within a 10-year time period were included in this case–control study. Furthermore, both materials were seeded with human osteoblasts (hOB, n = 10) and analyzed by histology, for viability (AlamarBlue®) and protein expression activity (Luminex®). Results The complication rate was 14.2 %, proportion of defects without bony healing 3.6 %; neither outcome parameter differed comparing the intervention groups. Failed consolidation correlated with an increase in complications (p < 0.03). The rate of complications was further highly significant in association with the location of use (p < 0.001), but did not depend on age, ASA risk classification, BMI, smoking behavior or type of insurance. However, those factors did significantly influence the bony healing rate (p < 0.02). Complication and consolidation rates were independent of gender and the filling substances employed within the different locations. Histological examination revealed similar bone structures, whereas cell remnants were apparent only in the allografts. Both materials were biocompatible in-vitro, and seeded with human osteoblasts. The cells remained vital over the 3-week culture period and produced microscopically typical bone matrix. We observed initially increased expression of osteocalcin, osteopontin, and osteoprotegerin as well as leptin and adiponectin secretion declining after 1 week, especially in the ACB group. Conclusion Although both investigated materials appeared to be similarly suitable for the treatment of skeletal lesions in-vivo and in-vitro, outcome was decisively influenced by other factors such as the site of use or epidemiological parameters.
Collapse
Affiliation(s)
- Eva Johanna Kubosch
- Department of Orthopedics and Trauma Surgery, Albert-Ludwigs University Medical Center, Freiburg, Germany.
| | - Anke Bernstein
- Department of Orthopedics and Trauma Surgery, Albert-Ludwigs University Medical Center, Freiburg, Germany.
| | - Laura Wolf
- Department of Orthopedics and Trauma Surgery, Albert-Ludwigs University Medical Center, Freiburg, Germany.
| | - Tobias Fretwurst
- Department of Craniomaxillofacial Surgery, Albert-Ludwigs University Medical Center, Freiburg, Germany.
| | - Katja Nelson
- Department of Craniomaxillofacial Surgery, Albert-Ludwigs University Medical Center, Freiburg, Germany.
| | - Hagen Schmal
- Department of Orthopedics and Trauma Surgery, Albert-Ludwigs University Medical Center, Freiburg, Germany. .,Department of Orthopaedics and Traumatology, Odense University Hospital, Odense, Denmark. .,Department of Clinical Research, University of Southern Denmark, Odense, Denmark.
| |
Collapse
|
22
|
Handford C, Nathoo S, Porter K, Kalogrianitis S. A review of current concepts in the management of proximal humerus fractures. TRAUMA-ENGLAND 2015. [DOI: 10.1177/1460408614555069] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Fracture of the proximal humerus is a common orthopaedic injury and is likely to increase in incidence. This fracture type is associated with a wide variety in fracture morphology and as a direct result there are many treatment options available. It is often not clear what treatment modality should be utilised. This article reviews the current literature on proximal humerus fractures offering evidence for care pathways and management strategies from presentation to rehabilitation.
Collapse
|
23
|
Liu K, Liu PC, Liu R, Wu X. Advantage of minimally invasive lateral approach relative to conventional deltopectoral approach for treatment of proximal humerus fractures. Med Sci Monit 2015; 21:496-504. [PMID: 25682320 PMCID: PMC4335575 DOI: 10.12659/msm.893323] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Background Despite the wide application of open reduction and internal fixation with locking plates for the treatment of proximal humeral fractures, the surgical invasive approach remains controversial. This study aimed to evaluate the pros and cons of the minimally invasive lateral approach for the treatment of proximal humeral fracture (PHF) in comparison with the deltopectoral approach. Material/Methods All patients who sustained a PHF and received open reduction and internal fixation (ORIF) surgery with locking plate through either minimally invasive subacromial approach or conventional deltopectoral approach between January 2008 and February 2012 were retrospectively analyzed. Patients were divided into the conventional group and min-group according to the surgical incision. Surgery-related information, postoperative radiography, complications, and shoulder functional measurement scores in a 2-year follow-up were collected and evaluated. Results Ninety-one patients meeting the inclusion criteria were included in this study. We observed a significant difference in both surgery time (81.8±18.3 vs. 91.0±18.4) (p=0.021) and blood loss (172±54.2 vs. 205±73.6) (p=0.016) between the min-group and conventional group. Compared to the conventional group, the min-group had significantly better Constant-Murley score and DASH score at early follow-up (p<0.05) and higher patients satisfaction rate (8.1±1.1 vs. 7.6±1.2) (p= 0.019). The multiple linear regression analysis indicated that age, PHF types, surgical groups, surgery time, and blood loss have significant effect on the activity of affected shoulder in both abduction and forward flexion (p<0.05) except for gender factor. While larger range of movement of the affected shoulder, mainly in the 2-part and 3-part fractures, was observed in the min-group, the conventional group obtained better movement in the 4-part fractures. Conclusions The minimally invasive lateral approach is the optimal alternative for the treatment of Neer’s type 2 and 3 proximal humerus fractures.
Collapse
Affiliation(s)
- Kuan Liu
- Department of Orthopaedics, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Peng-cheng Liu
- Department of Orthopaedics, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Run Liu
- Department of Orthopaedics, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| | - Xing Wu
- Department of Orthopaedics, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China (mainland)
| |
Collapse
|
24
|
Hussain S, Gul M, Dhar S. Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate. Malays Orthop J 2014; 8:8-13. [PMID: 25279078 PMCID: PMC4093544 DOI: 10.5704/moj.1403.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
ABSTRACT BACKGROUND Proximal humeral fractures are considered the last unsolved fractures in orthopaedics. The treatment is controversial and various operative modalities have been reported in the literature. The aim of the present study was to evaluate functional outcome and complication rate after open reduction and internal fixation of displaced proximal humerus fractures by proximal humerus AO stainless steel T-plate. Twenty-five (25) patients with displaced proximal humerus fractures treated with proximal humerus T-plate between May 2005 and June 2008 were included in the study. Fractures were classified according to the Neer classification into displaced 2-part, 3-part, and 4-part fractures. Patients were followed-up for a minimum period of two years. Functional evaluation was done according to the Neer scoring system. Scores were compared with other studies in the literature using similar implant. Twenty patients had 2-part fracture, four had 3-part fracture, and one had 4-part fracture. Eighty-eight [88% (n = 22)] patients had good to excellent result, eight [8% (n = 2)] had fair, and four [4% (n = 1)] had poor result. Difference in Neer's score between 2-part and 3-part fractures was not significant. Complications encountered in this series were screw backout in 8% (n = 2), superficial infection in 12% (n = 3), and avascular necrosis in 4% (n = 1) of cases. We conclude that proximal humerus AO T- plate is a cheap and easily available implant, aspects which are particularly relevant in third world countries like India. It gives reliable fixation for 2-part and 3-part fractures. Its use in more complicated fracture patterns of 4-part fractures is not recommended. KEY WORDS Proximal humerus fractures, proximal humerus stainless steel T-plate, unstable fracture.
Collapse
Affiliation(s)
- S Hussain
- Hospital for Bone & Joint Surgery, Srinagar, India
| | - Ma Gul
- Hospital for Bone & Joint Surgery, Srinagar, India
| | - Sa Dhar
- Sher-i Kashmir Institute of Medical Sciences, Medical College & Hospital, Srinagar, India
| |
Collapse
|