1
|
Ghosh A, Kumar S, Singh PP, Nandi S, Mandal M, Pradhan D, Khatua BB, Das RK. Dynamic Metal-Coordinated Adhesive and Self-Healable Antifreezing Hydrogels for Strain Sensing, Flexible Supercapacitors, and EMI Shielding Applications. ACS OMEGA 2024; 9:33204-33223. [PMID: 39100348 PMCID: PMC11292641 DOI: 10.1021/acsomega.4c04851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Revised: 07/03/2024] [Accepted: 07/08/2024] [Indexed: 08/06/2024]
Abstract
Dynamic metal-coordinated adhesive and self-healable hydrogel materials have garnered significant attention in recent years due to their potential applications in various fields. These hydrogels can form reversible metal-ligand bonds, resulting in a network structure that can be easily broken and reformed, leading to self-healing capabilities. In addition, these hydrogels possess excellent mechanical strength and flexibility, making them suitable for strain-sensing applications. In this work, we have developed a mechanically robust, highly stretchable, self-healing, and adhesive hydrogel by incorporating Ca2+-dicarboxylate dynamic metal-ligand cross-links in combination with low density chemical cross-links into a poly(acrylamide-co-maleic acid) copolymer structure. Utilizing the reversible nature of the Ca2+-dicarboxylate bond, the hydrogel exhibited a tensile strength of up to ∼250 kPa and was able to stretch to 15-16 times its original length. The hydrogel exhibited a high fracture energy of ∼1500 J m-2, similar to that of cartilage. Furthermore, the hydrogel showed good recovery, fatigue resistance, and fast self-healing properties due to the reversible Ca2+-dicarboxylate cross-links. The presence of Ca2+ resulted in a highly conductive hydrogel, which was utilized to design a flexible resistive strain sensor. This hydrogel can strongly adhere to different substrates, making it advantageous for applications in flexible electronic devices. When adhered to human body parts, the hydrogel can efficiently detect limb movements. The hydrogel also exhibited excellent performance as a solid electrolyte for flexible supercapacitors, with a capacitance of ∼260 F/g at 0.5 A/g current density. Due to its antifreezing and antidehydration properties, this hydrogel retains its flexibility at subzero temperatures for an extended period. Additionally, the porous network and high water content of the hydrogel impart remarkable electromagnetic attenuation properties, with a value of ∼38 dB in the 14.5-20.5 GHz frequency range, which is higher than any other hydrogel without conducting fillers. Overall, the hydrogel reported in this study exhibits diverse applications as a strain sensor, solid electrolyte for flexible supercapacitors, and efficient material for electromagnetic attenuation. Its multifunctional properties make it a promising candidate for use in various fields as a state-of-the-art material.
Collapse
Affiliation(s)
- Ashis Ghosh
- Materials
Science Centre, Indian Institute of Technology
Kharagpur, Kharagpur 721302, India
| | - Sudhir Kumar
- Materials
Science Centre, Indian Institute of Technology
Kharagpur, Kharagpur 721302, India
| | - Prem Pal Singh
- Materials
Science Centre, Indian Institute of Technology
Kharagpur, Kharagpur 721302, India
| | - Suvendu Nandi
- School
of Medical Science and Technology, Indian
Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Mahitosh Mandal
- School
of Medical Science and Technology, Indian
Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Debabrata Pradhan
- Materials
Science Centre, Indian Institute of Technology
Kharagpur, Kharagpur 721302, India
| | - Bhanu Bhusan Khatua
- Materials
Science Centre, Indian Institute of Technology
Kharagpur, Kharagpur 721302, India
| | - Rajat Kumar Das
- Materials
Science Centre, Indian Institute of Technology
Kharagpur, Kharagpur 721302, India
| |
Collapse
|
2
|
Zarif ME, Bita B, Yehia-Alexe SA, Negut I, Gradisteanu Pircalabioru G, Andronescu E, Groza A. Biological and Physicochemical Analysis of Sr-Doped Hydroxyapatite/Chitosan Composite Layers. Polymers (Basel) 2024; 16:1922. [PMID: 39000777 PMCID: PMC11244040 DOI: 10.3390/polym16131922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 06/06/2024] [Accepted: 07/02/2024] [Indexed: 07/17/2024] Open
Abstract
In this work results are presented on the evaluation of HAp, HApSr, HAp_CS, and HApSr_CS layers deposited on Ti substrates regarding L929 cell viability and cytotoxicity as well as antimicrobial activity against Staphylococcus aureus, in connection with their physicochemical properties. The HAp and HApSr layers generated by radio-frequency magnetron sputtering technique were further covered with chitosan by a matrix-assisted pulsed laser evaporation technique. During the plasma depositions, the Ti substrates were heated externally by a home-made oven above 100 °C. The HApSr_CS layers generated on the unpolished Ti substrates at 100 °C and 400 °C showed the highest biocompatibility properties and antimicrobial activity against Staphylococcus aureus. The morphology of the layer surfaces, revealed by scanning electron microscopy, is dependent on substrate temperature and substrate surface roughness. The optically polished surfaces of Ti substrates revealed grain-like and microchannel structure morphologies of the layers deposited at 25 °C substrate temperature and 400 °C, respectively. Chitosan has no major influence on HAp and HApSr layer surface morphologies. X-ray photoelectron spectroscopy indicated the presence of Ca 2p3/2 peak characteristic of the HAp structure even in the case of the HApSr_CS samples generated at a 400 °C substrate temperature. Fourier transform infrared spectroscopy investigations showed shifts in the wavenumber positions of the P-O absorption bands as a function of Sr or chitosan presence in the HAp layers generated at 25, 100, and 400 °C substrate temperatures.
Collapse
Affiliation(s)
- Maria Elena Zarif
- National Institute for Lasers, Plasma and Radiation Physics, 077125 Măgurele, Romania; (M.E.Z.); (B.B.); (S.A.Y.-A.); (I.N.)
- Faculty of Chemical Engineering and Biotechnologies, University Politehnica of Bucharest, 011061 Bucharest, Romania;
| | - Bogdan Bita
- National Institute for Lasers, Plasma and Radiation Physics, 077125 Măgurele, Romania; (M.E.Z.); (B.B.); (S.A.Y.-A.); (I.N.)
- Faculty of Physics, University of Bucharest, 077125 Măgurele, Romania
| | - Sasa Alexandra Yehia-Alexe
- National Institute for Lasers, Plasma and Radiation Physics, 077125 Măgurele, Romania; (M.E.Z.); (B.B.); (S.A.Y.-A.); (I.N.)
- Faculty of Physics, University of Bucharest, 077125 Măgurele, Romania
| | - Irina Negut
- National Institute for Lasers, Plasma and Radiation Physics, 077125 Măgurele, Romania; (M.E.Z.); (B.B.); (S.A.Y.-A.); (I.N.)
| | - Gratiela Gradisteanu Pircalabioru
- eBio-Hub Research Center, University Politehnica of Bucharest-CAMPUS, 6 Iuliu Maniu Boulevard, 061344 Bucharest, Romania;
- Research Institute of the University of Bucharest (ICUB), University of Bucharest, 050657 Bucharest, Romania
- Department of Microbiology and Immunology, Faculty of Biology, University of Bucharest, 050657 Bucharest, Romania
| | - Ecaterina Andronescu
- Faculty of Chemical Engineering and Biotechnologies, University Politehnica of Bucharest, 011061 Bucharest, Romania;
- Academy of Romanian Scientists, 3 Ilfov Str., District 5, 050044 Bucharest, Romania
- National Research Center for Micro and Nanomaterials, University Politehnica of Bucharest, 060042 Bucharest, Romania
| | - Andreea Groza
- National Institute for Lasers, Plasma and Radiation Physics, 077125 Măgurele, Romania; (M.E.Z.); (B.B.); (S.A.Y.-A.); (I.N.)
| |
Collapse
|
3
|
Tabira K, Kajimoto N, Minamisawa H, Sato T, Maruta M, Oka K, Kataoka T, Yoshioka T, Hayakawa S, Tsuru K. Functional evaluation of mineral trioxide aggregate cement with choline dihydrogen phosphate. Dent Mater J 2023. [PMID: 37121734 DOI: 10.4012/dmj.2022-283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
To improve the cytocompatibility of mineral trioxide aggregate (MTA) cement and its ability for reparative dentin formation, the effect of adding choline dihydrogen phosphate (CDHP), which is reported to be biocompatible, to MTA cement was investigated. The L929 cell proliferation showed that the addition of CDHP improved cell viability. The addition of CDHP shortened the setting time of MTA cement, with a significant decrease in consistency above 0.4 g/mL. Diametral tensile strength of the set cement was improved by the addition of 0.4 g/mL CDHP. Solubility was judged to be within the range of clinical application. The spontaneous precipitation of low crystalline hydroxyapatite was examined by immersing the set cement in phosphate buffer saline, and it was found that the ability of the cement with 0.4 g/mL of CDHP was significantly improved compared with that of the cement without CDHP.
Collapse
Affiliation(s)
- Kazuhisa Tabira
- Section of Bioengineering, Department of Dental Engineering, Fukuoka Dental College
- Section of Pediatric Dentistry, Department of Oral Growth and Development, Fukuoka Dental College
| | - Noboru Kajimoto
- Section of Bioengineering, Department of Dental Engineering, Fukuoka Dental College
| | - Hirogo Minamisawa
- Section of Bioengineering, Department of Dental Engineering, Fukuoka Dental College
| | - Taira Sato
- Section of Biomaterials, Department of Dental Engineering, Fukuoka Dental College
| | - Michito Maruta
- Section of Bioengineering, Department of Dental Engineering, Fukuoka Dental College
| | - Kyoko Oka
- Section of Pediatric Dentistry, Department of Oral Growth and Development, Fukuoka Dental College
- Oral Medicine Research Center, Fukuoka Dental College
| | - Takuya Kataoka
- Biomaterials Laboratory, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University
| | - Tomohiko Yoshioka
- Biomaterials Laboratory, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University
| | - Satoshi Hayakawa
- Biomaterials Laboratory, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University
| | - Kanji Tsuru
- Section of Bioengineering, Department of Dental Engineering, Fukuoka Dental College
| |
Collapse
|
4
|
Youssef AR, Elsherief S. Evaluation of the cytotoxic effects of a new Harvard MTA compared to MTA Flow and ProRoot MTA on human gingival fibroblasts. Saudi Dent J 2021; 33:679-686. [PMID: 34803319 PMCID: PMC8589600 DOI: 10.1016/j.sdentj.2020.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 04/25/2020] [Accepted: 04/26/2020] [Indexed: 10/27/2022] Open
Abstract
Background Biocompatibility is an essential property for any dental root repair material that may interact with the surrounding periodontal tissues. We hypothesise that the three mineral trioxide aggregate (MTA) restorative brands ProRoot MTA, MTA Flow and Harvard MTA have similar biocompatibility. To test this hypothesis, we compared the cytotoxic effects of these materials on human gingival fibroblast (GF). Methods MTA cements were prepared, and after completion of setting, they were incubated in Dulbecco's Modified Eagle Medium for 1 day or 4 days to obtain low and high concentrations of MTA elutes respectively. The elutes of MTA supplemented with fetal bovine serum were added to GF and incubated for 3 days at 37 °C and 5% CO2. Untreated cells were used as control. The cell viability was assessed using a 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) assay at 24, 48 and 72 h. Results After 24 h, the MTT assay showed that both 1- and 4-day elutes of MTA flow and Harvard MTA reduced cell viability significantly compared to control (P < 0.05). After 48 h, the 1-day elute of ProRoot MTA induced GF proliferation (P = 0.0136) while MTA flow and Harvard MTA were similar to control. After 72 h, the 1-day elute of ProRoot MTA and Harvard MTA induced GF proliferation, while the elute of MTA flow was comparable to control. The 4-day elute of Harvard MTA continued to be cytotoxic to GF after 24 h, 48 h, and 72 h incubation, while the 4-day elute of ProRoot MTA and MTA flow were similar to control. Conclusion ProRoot MTA and MTA Flow showed comparable biocompatibility. However, the 4-day elute of Harvard MTA was cytotoxic to GF. Further studied are required to assess the cell viability after direct contact with these materials versus eluent in vitro and compare these sealers in the clinical setting.
Collapse
Affiliation(s)
- Abdel-Rahman Youssef
- Department of Basic and Clinical Oral Sciences, Faculty of Dentistry, Umm Al-Qura University, Saudi Arabia.,Department of Microbiology, Faculty of Medicine, Suez Canal University, Egypt
| | - Samia Elsherief
- Department of Endodontics, Faculty of Dentistry, Umm Al-Qura University, Saudi Arabia.,Department of Endodontics, Faculty of Oral and Dental Medicine, Cairo University, Egypt
| |
Collapse
|
5
|
Toxicity screening of a novel poly(methylmethacrylate)-Eudragit nanocarrier on L929 fibroblasts. Toxicol Lett 2017; 276:129-137. [DOI: 10.1016/j.toxlet.2017.05.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 05/02/2017] [Accepted: 05/15/2017] [Indexed: 01/25/2023]
|
6
|
Huang YS, Bertrand V, Bozukova D, Pagnoulle C, Labrugère C, De Pauw E, De Pauw-Gillet MC, Durrieu MC. RGD surface functionalization of the hydrophilic acrylic intraocular lens material to control posterior capsular opacification. PLoS One 2014; 9:e114973. [PMID: 25501012 PMCID: PMC4263720 DOI: 10.1371/journal.pone.0114973] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2014] [Accepted: 11/17/2014] [Indexed: 11/19/2022] Open
Abstract
Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development.
Collapse
Affiliation(s)
- Yi-Shiang Huang
- Departments of Chemistry & Bio-Medical and Preclinical Sciences, Mass Spectrometry Laboratory & Mammalian Cell Culture Laboratory – GIGA R, Université de Liège, Liège, Belgium
- CBMN UMR5248, Institute of Chemistry & Biology of Membranes & Nanoobjects, Université de Bordeaux, Pessac, France
| | - Virginie Bertrand
- Departments of Chemistry & Bio-Medical and Preclinical Sciences, Mass Spectrometry Laboratory & Mammalian Cell Culture Laboratory – GIGA R, Université de Liège, Liège, Belgium
| | | | | | - Christine Labrugère
- PLACAMAT, Plateforme Aquitaine de Caractérisation des Matériaux, UMS 3626, Université de Bordeaux, Pessac, France
| | - Edwin De Pauw
- Departments of Chemistry & Bio-Medical and Preclinical Sciences, Mass Spectrometry Laboratory & Mammalian Cell Culture Laboratory – GIGA R, Université de Liège, Liège, Belgium
| | - Marie-Claire De Pauw-Gillet
- Departments of Chemistry & Bio-Medical and Preclinical Sciences, Mass Spectrometry Laboratory & Mammalian Cell Culture Laboratory – GIGA R, Université de Liège, Liège, Belgium
| | - Marie-Christine Durrieu
- CBMN UMR5248, Institute of Chemistry & Biology of Membranes & Nanoobjects, Université de Bordeaux, Pessac, France
| |
Collapse
|