Moon HS, Song SY, Oh JU, Seo YJ. Effects of modified trans-tibial versus trans-portal technique on stress patterns around the femoral tunnel in anatomical single-bundle ACL reconstruction with different knee flexion angles using finite element analysis. BMC Musculoskelet Disord 2022; 23:759. [PMID: 35941643 PMCID: PMC9361554 DOI: 10.1186/s12891-022-05713-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 07/27/2022] [Indexed: 12/20/2022] Open
Abstract
Background It is unclear whether different anterior cruciate ligament (ACL) graft trajectories in the distal femur would have different effects on stress generated within the distal femur around the femoral tunnel during knee motion. Thus, the purpose of this study was to determine differences in stress patterns around the femoral tunnel created by trans-portal (TP) vs. modified trans-tibial (TT) technique in anatomical ACL reconstruction at different knee flexion angles. Methods Twelve male subjects’ right knees were scanned with a high-resolution computed tomography (CT) scanner (slice thickness: 1 mm) at four different knee flexion angles (0°, 45°, 90°, and 135°). Three-dimensional (3D) models of these four different flexion angles were created and manipulated with several modelling programs. For the TP group, the virtual femoral tunnelling procedure was performed in a 135° flexion model from the low far anteromedial (AM) portal. For the modified TT group, the same knee models were drilled through the modified TT technique at 90° of flexion separately. Virtual grafts under tension of 40 N were put into corresponding bone tunnel and fixed at the outer aperture of femoral tunnels to simulate the suspensory fixation, followed by fixation of the grafts at the middle of tibial tunnels in the 0° knee flexion models. Finally, the models were exported to a finite element analysis package and analysed using ABAQUS/Explicit code (ABAQUS, USA) to monitor the stress occurring at the node where stress distribution occurred most significantly in the femoral bone around the bone tunnel. Results In general, both groups showed a high stress distribution in bony structures around inner and outer orifices of the femoral tunnel. Mean maximal stresses occurring at the lateral femoral condyle around the inner orifice of the femoral tunnel in the TP group were found to be significantly greater than those in the modified TT group at all flexion angles except 90° of flexion. Mean maximal stresses monitored around the outer orifice of the femoral tunnel in the TP group were also significantly greater than those in the modified TT group at all flexion angles. Conclusions Different tunnelling technologies could yield different stress patterns in the lateral femoral condyle around the femoral tunnel. During knee motion, higher stresses were noticed in the TP group than in the modified TT group, especially around inner and outer orifices of the tunnel. Position of the tunnel after reconstruction with the TP technique can have a greater effect on the stress increase in the femur compared to that with the modified TT technique.
Collapse
Affiliation(s)
- Hyun-Soo Moon
- Department of Orthopedic Surgery, Hallym University Sacred Heart Hospital, Anyang, Gyeonggi-do, Republic of Korea
| | - Si Young Song
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, 7, Keunjaebong-gil, Hwaseong, Gyeonggi-do, Republic of Korea
| | - Ji Ung Oh
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, 7, Keunjaebong-gil, Hwaseong, Gyeonggi-do, Republic of Korea
| | - Young-Jin Seo
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, 7, Keunjaebong-gil, Hwaseong, Gyeonggi-do, Republic of Korea.
| |
Collapse
|
2
|
Zhang L, Lai ZW, Shah MA. Construction of 3D model of knee joint motion based on MRI image registration. JOURNAL OF INTELLIGENT SYSTEMS 2021. [DOI: 10.1515/jisys-2021-0161] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Abstract
There is a growing demand for information and computational technology for surgeons help with surgical planning as well as prosthetics design. The two-dimensional images are registered to the three-dimensional (3D) model for high efficiency. To reconstruct the 3D model of knee joint including bone structure and main soft tissue structure, the evaluation and analysis of sports injury and rehabilitation treatment are detailed in this study. Mimics 10.0 was used to reconstruct the bone structure, ligament, and meniscus according to the pulse diffusion-weighted imaging sequence (PDWI) and stir sequences of magnetic resonance imaging (MRI). Excluding congenital malformations and diseases of the skeletal muscle system, MRI scanning was performed on bilateral knee joints. Proton weighted sequence (PDWI sequence) and stir pulse sequence were selected for MRI. The models were imported into Geomagic Studio 11 software for refinement and modification, and 3D registration of bone structure and main soft tissue structure was performed to construct a digital model of knee joint bone structure and accessory cartilage and ligament structure. The 3D knee joint model including bone, meniscus, and collateral ligament was established. Reconstruction and image registration based on mimics and Geomagic Studio can build a 3D model of knee joint with satisfactory morphology, which can meet the requirements of teaching, motion simulation, and biomechanical analysis.
Collapse
Affiliation(s)
- Lei Zhang
- Henan Polytechnic Institute , Nanyang Henan , 473000 , China
| | - Zheng Wen Lai
- Guangzhou Maritime University, Guangzhou , Guangdong , China
| | | |
Collapse
|
3
|
Seo YJ, Song SY, Im WY, Kim YS, Jang SW. Effects of flexible reamer on the femoral tunnel characteristics in anterior cruciate ligament reconstruction. Medicine (Baltimore) 2021; 100:e27833. [PMID: 34766599 PMCID: PMC8589247 DOI: 10.1097/md.0000000000027833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 10/26/2021] [Indexed: 11/25/2022] Open
Abstract
To compare the femoral tunnel characteristics using a rigid versus flexible reamer during anterior cruciate ligament reconstruction. It was hypothesized that the employment of a flexible reamer along with femoral tunnel would exhibit longer tunnel length and more acute femoral graft tunnel angle compared to the case of a rigid reamer.The study population included 28 patients who underwent anatomical single-bundle anterior cruciate ligament reconstruction using transportal technique and were able to take postoperative computed tomography (CT) evaluation. Of these, the femoral tunnel of 14 cases was drilled with a flexible reamer (group I) and in another 14 cases drill was performed with a conventional rigid reamer (group II). The femoral tunnel in group I was made at 90° of knee flexion. In group II, the femoral tunnel was created at 120° of knee flexion. The parameters of the femoral tunnels were compared in terms of the femoral tunnel length and femoral graft tunnel angle. Special software was used to create and manipulate (3-D) 3-dimensional knee models.The difference in the mean femoral tunnel locations expressed in percentage distance between the 2 groups was not significantly different. The mean femoral tunnel length of group I was significantly longer than that of group II, (P = .03, 36.7 ± 2.9 vs 32.9 ± 9.0 mm). The angle formed by the femoral tunnel and the graft in group I was significantly smaller than in group II (P = .01, 109.8° ± 9.4° vs 118.1° ± 7.2°).Our data suggest that the flexible reamer can provide sufficient tunnel length for the suspensory fixation with a fixed loop. Whereas, the femoral graft-tunnel angle through flexible reaming at 90° of knee flexion was more acute compared to rigid reaming at 120° of knee flexion.Study Design: level of evidence III.
Collapse
Affiliation(s)
- Young-Jin Seo
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Gyeonggi-do, Republic of Korea
| | - Si Young Song
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Gyeonggi-do, Republic of Korea
| | - Woo-Young Im
- Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Gyeonggi-do, Republic of Korea
| | - Yoon Sang Kim
- BioComputing Lab, Institute for Bio-engineering Application Technology, School of Computer Science and Engineering, Korea University of Technology and Education (KOREATECH), Cheonan, Republic of Korea
| | - Seong-wook Jang
- BioComputing Lab, Institute for Bio-engineering Application Technology, School of Computer Science and Engineering, Korea University of Technology and Education (KOREATECH), Cheonan, Republic of Korea
| |
Collapse
|
4
|
Kim SJ, Song SY, Kim TS, Kim YS, Jang SW, Seo YJ. Creating a Femoral Tunnel Aperture at the Anteromedial Footprint Versus the Central Footprint in ACL Reconstruction: Comparison of Contact Stress Patterns. Orthop J Sports Med 2021; 9:23259671211001802. [PMID: 33997070 PMCID: PMC8111278 DOI: 10.1177/23259671211001802] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 12/15/2020] [Indexed: 11/16/2022] Open
Abstract
Background: It remains unclear whether an anteromedial (AM) footprint or a central footprint anterior cruciate ligament (ACL) graft exhibits less contact stress with the femoral tunnel aperture. This contact stress can generate graft attrition forces, which can lead to potential graft failure. Purpose/Hypothesis: The purpose of this study was to compare the difference in contact stress patterns of the graft around a femoral tunnel that is created at the anatomic AM footprint versus the central footprint. It was hypothesized that the difference in femoral tunnel positions would influence the contact stress at the interface between the reconstructed graft and the femoral tunnel orifice. Study Design: Controlled laboratory study. Methods: A total of 24 patients who underwent anatomic single-bundle ACL reconstruction were included in this study. In 12 patients, the femoral tunnels were created at the center of the native AM footprint (AM group), and in the remaining 12 patients the center of the femoral tunnel was placed in the anatomic central footprint (central group). Three-dimensional knee models were created and manipulated using several modeling programs, and the graft-tunnel angle (GTA) was determined using a special software program. The peak contact stresses generated on the virtual ACL graft around the femoral tunnel orifice were calculated using a finite element method. Results: The mean GTA was significantly more obtuse in the AM group than in the central group (124.2° ± 5.9° vs 112.6° ± 7.9°; P = .001). In general, both groups showed high stress distribution on the anterior surface of the graft, which came in contact with the anterior aspect of the femoral tunnel aperture. The degree of stress in the central group (5.3 ± 2.6 MPa) was significantly higher than that in the AM group (1.2 ± 1.1 MPa) (P < .001). Conclusion: Compared with the AM footprint ACL graft, the central footprint ACL graft developed significantly higher contact stress in the extended position, especially around the anterior aspect of the femoral tunnel orifice. Clinical Relevance: The contact stress of the ACL graft at the extended position of the knee may be minimized by creating the femoral tunnel at the AM-oriented footprint.
Collapse
Affiliation(s)
- Sung-Jae Kim
- Department of Orthopaedic Surgery, Hallym University, Dongtan Sacred Heart Hospital, Hwaseong, Gyeonggi-do, Republic of Korea
| | - Si Young Song
- Department of Orthopaedic Surgery, Hallym University, Dongtan Sacred Heart Hospital, Hwaseong, Gyeonggi-do, Republic of Korea
| | - Tae Soung Kim
- Department of Orthopaedic Surgery, Hallym University, Dongtan Sacred Heart Hospital, Hwaseong, Gyeonggi-do, Republic of Korea
| | - Yoon Sang Kim
- BioComputing Lab, School of Computer Science and Engineering, Korea University of Technology and Education (KOREATECH), Cheonan, Republic of Korea
| | - Seong-Wook Jang
- BioComputing Lab, School of Computer Science and Engineering, Korea University of Technology and Education (KOREATECH), Cheonan, Republic of Korea
| | - Young-Jin Seo
- Department of Orthopaedic Surgery, Hallym University, Dongtan Sacred Heart Hospital, Hwaseong, Gyeonggi-do, Republic of Korea
| |
Collapse
|
5
|
Automatic Segmentation and Measurement on Knee Computerized Tomography Images for Patellar Dislocation Diagnosis. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2021; 2020:1782531. [PMID: 32454878 PMCID: PMC7212331 DOI: 10.1155/2020/1782531] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 12/04/2019] [Accepted: 12/10/2019] [Indexed: 11/18/2022]
Abstract
Traditionally, for diagnosing patellar dislocation, clinicians make manual geometric measurements on computerized tomography (CT) images taken in the knee area, which is often complex and error-prone. Therefore, we develop a prototype CAD system for automatic measurement and diagnosis. We firstly segment the patella and the femur regions on the CT images and then measure two geometric quantities, patellar tilt angle (PTA), and patellar lateral shift (PLS) automatically on the segmentation results, which are finally used to assist in diagnoses. The proposed quantities are proved valid and the proposed algorithms are proved effective by experiments.
Collapse
|
6
|
Engelkes K. Accuracy of bone segmentation and surface generation strategies analyzed by using synthetic CT volumes. J Anat 2020; 238:1456-1471. [PMID: 33325545 DOI: 10.1111/joa.13383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 11/19/2020] [Accepted: 11/25/2020] [Indexed: 11/30/2022] Open
Abstract
Different kinds of bone measurements are commonly derived from computed-tomography (CT) volumes to answer a multitude of questions in biology and related fields. The underlying steps of bone segmentation and, optionally, polygon surface generation are crucial to keep the measurement error small. In this study, the performance of different, easily accessible segmentation techniques (global thresholding, automatic local thresholding, weighted random walk, neural network, and watershed) and surface generation approaches (different algorithms combined with varying degrees of simplification) was analyzed and recommendations for minimizing inaccuracies were derived. The different approaches were applied to synthetic CT volumes for which the correct segmentation and surface geometry were known. The most accurate segmentations of the synthetic volumes were achieved by setting a case-specific window to the gray value histogram and subsequently applying automatic local thresholding with appropriately chosen thresholding method and radius. Surfaces generated by the Amira® module Generate Lego Surface in combination with careful surface simplification were the most accurate. Surfaces with sub-voxel accuracy were obtained even for synthetic CT volumes with low contrast-to-noise ratios. Segmentation trials with real CT volumes supported the findings. Very accurate segmentations and surfaces can be derived from CT volumes by using readily accessible software packages. The presented results and derived recommendations will help to reduce the measurement error in future studies. Furthermore, the demonstrated strategies for assessing segmentation and surface qualities can be adopted to quantify the performance of new segmentation approaches in future studies.
Collapse
Affiliation(s)
- Karolin Engelkes
- Center of Natural History (CeNak), Universität Hamburg, Hamburg, Germany
| |
Collapse
|
7
|
A Comparative Systematic Literature Review on Knee Bone Reports from MRI, X-rays and CT Scans Using Deep Learning and Machine Learning Methodologies. Diagnostics (Basel) 2020; 10:diagnostics10080518. [PMID: 32722605 PMCID: PMC7460189 DOI: 10.3390/diagnostics10080518] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 07/02/2020] [Accepted: 07/15/2020] [Indexed: 01/26/2023] Open
Abstract
The purpose of this research was to provide a “systematic literature review” of knee bone reports that are obtained by MRI, CT scans, and X-rays by using deep learning and machine learning techniques by comparing different approaches—to perform a comprehensive study on the deep learning and machine learning methodologies to diagnose knee bone diseases by detecting symptoms from X-ray, CT scan, and MRI images. This study will help those researchers who want to conduct research in the knee bone field. A comparative systematic literature review was conducted for the accomplishment of our work. A total of 32 papers were reviewed in this research. Six papers consist of X-rays of knee bone with deep learning methodologies, five papers cover the MRI of knee bone using deep learning approaches, and another five papers cover CT scans of knee bone with deep learning techniques. Another 16 papers cover the machine learning techniques for evaluating CT scans, X-rays, and MRIs of knee bone. This research compares the deep learning methodologies for CT scan, MRI, and X-ray reports on knee bone, comparing the accuracy of each technique, which can be used for future development. In the future, this research will be enhanced by comparing X-ray, CT-scan, and MRI reports of knee bone with information retrieval and big data techniques. The results show that deep learning techniques are best for X-ray, MRI, and CT scan images of the knee bone to diagnose diseases.
Collapse
|
8
|
Jędzierowska M, Koprowski R, Wilczyński S, Krysik K. A new method for detecting the outer corneal contour in images from an ultra-fast Scheimpflug camera. Biomed Eng Online 2019; 18:115. [PMID: 31796067 PMCID: PMC6888987 DOI: 10.1186/s12938-019-0735-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Accepted: 11/22/2019] [Indexed: 01/28/2023] Open
Abstract
Background The Corvis® ST tonometer is an innovative device which, by combining a classic non-contact tonometer with an ultra-fast Scheimpflug camera, provides a number of parameters allowing for the assessment of corneal biomechanics. The acquired biomechanical parameters improve medical diagnosis of selected eye diseases. One of the key elements in biomechanical measurements is the correct corneal contour detection, which is the basis for further calculations. The presented study deals with the problem of outer corneal edge detection based on a series of images from the afore-mentioned device. Corneal contour detection is the first and extremely important stage in the acquisition and analysis of corneal dynamic parameters. Result A total of 15,400 images from the Corvis® ST tonometer acquired from 110 patients undergoing routine ophthalmologic examinations were analysed. A method of outer corneal edge detection on the basis of a series of images from the Corvis® ST was proposed. The method was compared with known and commonly used edge detectors: Sobel, Roberts, and Canny operators, as well as others, known from the literature. The analysis was carried out in MATLAB® version 9.0.0.341360 (R2016a) with the Image Processing Toolbox (version 9.4) and the Neural Network Toolbox (version 9.0). The method presented in this paper provided the smallest values of the mean error (0.16%), stability (standard deviation 0.19%) and resistance to noise, characteristic for Corvis® ST tonometry tests, compared to the methods known from the literature. The errors were 5.78 ± 9.19%, 3.43 ± 6.21%, and 1.26 ± 3.11% for the Roberts, Sobel, and Canny methods, respectively. Conclusions The proposed new method for detecting the outer corneal contour increases the accuracy of intraocular pressure measurements. It can be used to analyse dynamic parameters of the cornea.
Collapse
Affiliation(s)
- Magdalena Jędzierowska
- Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, ul. Będzińska 39, 41-200, Sosnowiec, Poland.
| | - Robert Koprowski
- Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, ul. Będzińska 39, 41-200, Sosnowiec, Poland
| | - Sławomir Wilczyński
- Department of Basic Biomedical Science, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia in Katowice, Kasztanowa Street 3, 41-200, Sosnowiec, Poland
| | - Katarzyna Krysik
- Department of Ophthalmology with Paediatric Unit, St. Barbara Hospital, Trauma Centre, Plac Medykow 1, 41-200, Sosnowiec, Poland
| |
Collapse
|
9
|
Cabitza F, Locoro A, Banfi G. Machine Learning in Orthopedics: A Literature Review. Front Bioeng Biotechnol 2018; 6:75. [PMID: 29998104 PMCID: PMC6030383 DOI: 10.3389/fbioe.2018.00075] [Citation(s) in RCA: 119] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Accepted: 05/23/2018] [Indexed: 12/12/2022] Open
Abstract
In this paper we present the findings of a systematic literature review covering the articles published in the last two decades in which the authors described the application of a machine learning technique and method to an orthopedic problem or purpose. By searching both in the Scopus and Medline databases, we retrieved, screened and analyzed the content of 70 journal articles, and coded these resources following an iterative method within a Grounded Theory approach. We report the survey findings by outlining the articles' content in terms of the main machine learning techniques mentioned therein, the orthopedic application domains, the source data and the quality of their predictive performance.
Collapse
Affiliation(s)
- Federico Cabitza
- Dipartimento di Informatica, Sistemistica e Comunicazione, Universitá degli Studi di Milano-Bicocca, Milan, Italy
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | | | - Giuseppe Banfi
- Dipartimento di Informatica, Sistemistica e Comunicazione, Universitá degli Studi di Milano-Bicocca, Milan, Italy
| |
Collapse
|