• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4622684)   Today's Articles (294)   Subscriber (49406)
For: Ding X, Liao SH, Zhu XH, Wang HM. Influence of orthotropy on biomechanics of peri-implant bone in complete mandible model with full dentition. Biomed Res Int 2014;2014:709398. [PMID: 25530968 DOI: 10.1155/2014/709398] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 09/01/2014] [Accepted: 09/01/2014] [Indexed: 11/19/2022]
Number Cited by Other Article(s)
1
Falcinelli C, Valente F, Vasta M, Traini T. Finite element analysis in implant dentistry: State of the art and future directions. Dent Mater 2023:S0109-5641(23)00092-1. [PMID: 37080880 DOI: 10.1016/j.dental.2023.04.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 04/22/2023]
2
Gholamalizadeh T, Moshfeghifar F, Ferguson Z, Schneider T, Panozzo D, Darkner S, Makaremi M, Chan F, Søndergaard PL, Erleben K. Open-Full-Jaw: An open-access dataset and pipeline for finite element models of human jaw. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022;224:107009. [PMID: 35872385 DOI: 10.1016/j.cmpb.2022.107009] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/02/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
3
Liu F, Mao ZH, Peng W, Wen S. Biomechanical influence of thread form on stress distribution over short implants (≤6 mm) using finite element analysis. BIOMED ENG-BIOMED TE 2022;67:53-60. [DOI: 10.1515/bmt-2020-0215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 12/17/2021] [Indexed: 11/15/2022]
4
Alemayehu DB, Jeng YR. Three-Dimensional Finite Element Investigation into Effects of Implant Thread Design and Loading Rate on Stress Distribution in Dental Implants and Anisotropic Bone. MATERIALS 2021;14:ma14226974. [PMID: 34832374 PMCID: PMC8624479 DOI: 10.3390/ma14226974] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 11/06/2021] [Accepted: 11/16/2021] [Indexed: 12/18/2022]
5
Chang Y, Tambe AA, Maeda Y, Wada M, Gonda T. Finite element analysis of dental implants with validation: to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process. Int J Implant Dent 2018. [PMID: 29516219 PMCID: PMC5842167 DOI: 10.1186/s40729-018-0119-5] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]  Open
6
Wang J, Zhang J, Lin J, Li W, Dai H, Hu H. Performance Analysis of a Fiber Reinforced Plastic Oil Cooler Cover Considering the Anisotropic Behavior of the Fiber Reinforced PA66. Polymers (Basel) 2016;8:polym8090312. [PMID: 30974599 PMCID: PMC6432006 DOI: 10.3390/polym8090312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 08/06/2016] [Accepted: 08/09/2016] [Indexed: 11/23/2022]  Open
7
Influence of Trabecular Bone on Peri-Implant Stress and Strain Based on Micro-CT Finite Element Modeling of Beagle Dog. BIOMED RESEARCH INTERNATIONAL 2016;2016:3926941. [PMID: 27403424 PMCID: PMC4923539 DOI: 10.1155/2016/3926941] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Accepted: 05/22/2016] [Indexed: 11/18/2022]
8
The influence of bone density and anisotropy in finite element models of distal radius fracture osteosynthesis: Evaluations and comparison to experiments. J Biomech 2015;48:4116-4123. [PMID: 26542787 DOI: 10.1016/j.jbiomech.2015.10.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Revised: 10/07/2015] [Accepted: 10/10/2015] [Indexed: 11/23/2022]
PrevPage 1 of 1 1Next