1
|
Falcinelli C, Valente F, Vasta M, Traini T. Finite element analysis in implant dentistry: State of the art and future directions. Dent Mater 2023:S0109-5641(23)00092-1. [PMID: 37080880 DOI: 10.1016/j.dental.2023.04.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 04/22/2023]
Abstract
OBJECTIVE To discuss the state of the art of Finite Element (FE) modeling in implant dentistry, to highlight the principal features and the current limitations, and giving recommendations to pave the way for future studies. METHODS The articles' search was performed through PubMed, Web of Science, Scopus, Science Direct, and Google Scholar using specific keywords. The articles were selected based on the inclusion and exclusion criteria, after title, abstract and full-text evaluation. A total of 147 studies were included in this review. RESULTS To date, the FE analysis of the bone-dental implant system has been investigated by analyzing several types of implants; modeling only a portion of bone considered as isotropic material, despite its anisotropic behavior; assuming in most cases complete osseointegration; considering compressive or oblique forces acting on the implant; neglecting muscle forces and the bone remodeling process. Finally, there is no standardized approach for FE modeling in the dentistry field. SIGNIFICANCE FE modeling is an effective computational tool to investigate the long-term stability of implants. The ultimate aim is to transfer such technology into clinical practice to help dentists in the diagnostic and therapeutic phases. To do this, future research should deeply investigate the loading influence on the bone-implant complex at a microscale level. This is a key factor still not adequately studied. Thus, a multiscale model could be useful, allowing to account for this information through multiple length scales. It could help to obtain information about the relationship among implant design, distribution of bone stress, and bone growth. Finally, the adoption of a standardized approach will be necessary, in order to make FE modeling highly predictive of the implant's long-term stability.
Collapse
Affiliation(s)
- Cristina Falcinelli
- Department of Engineering and Geology, University "G. d'Annunzio" of Chieti-Pescara, Viale Pindaro 42, Pescara 65127, Italy.
| | - Francesco Valente
- Department of Innovative Technologies in Medicine & Dentistry, University "G. d'Annunzio" of Chieti-Pescara, Via dei Vestini 31, Chieti 66100, Italy; Electron Microscopy Laboratory, University "G. d'Annunzio" of Chieti-Pescara, Via dei Vestini 31, Chieti 66100, Italy
| | - Marcello Vasta
- Department of Engineering and Geology, University "G. d'Annunzio" of Chieti-Pescara, Viale Pindaro 42, Pescara 65127, Italy
| | - Tonino Traini
- Department of Innovative Technologies in Medicine & Dentistry, University "G. d'Annunzio" of Chieti-Pescara, Via dei Vestini 31, Chieti 66100, Italy; Electron Microscopy Laboratory, University "G. d'Annunzio" of Chieti-Pescara, Via dei Vestini 31, Chieti 66100, Italy
| |
Collapse
|
2
|
Gholamalizadeh T, Moshfeghifar F, Ferguson Z, Schneider T, Panozzo D, Darkner S, Makaremi M, Chan F, Søndergaard PL, Erleben K. Open-Full-Jaw: An open-access dataset and pipeline for finite element models of human jaw. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 224:107009. [PMID: 35872385 DOI: 10.1016/j.cmpb.2022.107009] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/02/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND State-of-the-art finite element studies on human jaws are mostly limited to the geometry of a single patient. In general, developing accurate patient-specific computational models of the human jaw acquired from cone-beam computed tomography (CBCT) scans is labor-intensive and non-trivial, which involves time-consuming human-in-the-loop procedures, such as segmentation, geometry reconstruction, and re-meshing tasks. Therefore, with the current practice, researchers need to spend considerable time and effort to produce finite element models (FEMs) to get to the point where they can use the models to answer clinically-interesting questions. Besides, any manual task involved in the process makes it difficult for the researchers to reproduce identical models generated in the literature. Hence, a quantitative comparison is not attainable due to the lack of surface/volumetric meshes and FEMs. METHODS We share an open-access repository composed of 17 patient-specific computational models of human jaws and the utilized pipeline for generating them for reproducibility of our work. The used pipeline minimizes the required time for processing and any potential biases in the model generation process caused by human intervention. It gets the segmented geometries with irregular and dense surface meshes and provides reduced, adaptive, watertight, and conformal surface/volumetric meshes, which can directly be used in finite element (FE) analysis. RESULTS We have quantified the variability of our 17 models and assessed the accuracy of the developed models from three different aspects; (1) the maximum deviations from the input meshes using the Hausdorff distance as an error measurement, (2) the quality of the developed volumetric meshes, and (3) the stability of the FE models under two different scenarios of tipping and biting. CONCLUSIONS The obtained results indicate that the developed computational models are precise, and they consist of quality meshes suitable for various FE scenarios. We believe the provided dataset of models including a high geometrical variation obtained from 17 different models will pave the way for population studies focusing on the biomechanical behavior of human jaws.
Collapse
Affiliation(s)
- Torkan Gholamalizadeh
- Department of Computer Science, University of Copenhagen, Copenhagen 2100, Denmark; 3Shape A/S, Copenhagen 1060, Denmark.
| | - Faezeh Moshfeghifar
- Department of Computer Science, University of Copenhagen, Copenhagen 2100, Denmark
| | - Zachary Ferguson
- Courant Institute of Mathematical Sciences, New York University, 60 5th Ave, New York NY 10011, USA
| | - Teseo Schneider
- Department of Computer Science, University of Victoria, Victoria BC V8P 5C2, Canada
| | - Daniele Panozzo
- Courant Institute of Mathematical Sciences, New York University, 60 5th Ave, New York NY 10011, USA
| | - Sune Darkner
- Department of Computer Science, University of Copenhagen, Copenhagen 2100, Denmark
| | - Masrour Makaremi
- Dentofacial Orthopedics Department, University of Bordeaux, Bordeaux, France; Orthodontie clinic, 2 Rue des 2 Conils, Bergerac 24100, France
| | - François Chan
- Orthodontie clinic, 2 Rue des 2 Conils, Bergerac 24100, France
| | | | - Kenny Erleben
- Department of Computer Science, University of Copenhagen, Copenhagen 2100, Denmark
| |
Collapse
|
3
|
Liu F, Mao ZH, Peng W, Wen S. Biomechanical influence of thread form on stress distribution over short implants (≤6 mm) using finite element analysis. BIOMED ENG-BIOMED TE 2022; 67:53-60. [DOI: 10.1515/bmt-2020-0215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 12/17/2021] [Indexed: 11/15/2022]
Abstract
Abstract
The macro and micro design is essential to the biomechanical performance of a short implant. In this study, the implant thread parameters of short implants used in edentulous maxillae will be discussed. The aim of the study is to analyse biomechanical distinctions in different thread parameters over short implants by applying the vertical or oblique load of 130 N on dental prosthesis. A 6*5 mm implant will be used in posterior maxillae arch, where the molar region locates. The CAD model has been assembled by three parts, a crown, an implant system and a jaw. By applying the vertical or oblique load to the crown, the Von-Mises stresses of cortical bone and trabecular bone will be evaluated in pairs along the lines v1–v2 & a1–a2. The results showed that the reverse buttress thread would induce more stresses in cancellous bone whereas the buttress did the opposite. The trapezoidal thread (V-thread) is more favourable than the reverse buttress thread in accordance to the FEA result. The rectangle threads will induce more uneven stresses in cancellous bones.
Collapse
Affiliation(s)
- Fan Liu
- Division of Intelligent Manufacturing , Wuyi University , Jiangmen , Guangdong Province , China
| | - Zhi-Hong Mao
- Division of Intelligent Manufacturing , Wuyi University , Jiangmen , Guangdong Province , China
| | - Wujie Peng
- Division of Intelligent Manufacturing , Wuyi University , Jiangmen , Guangdong Province , China
| | - Sheng Wen
- Engineering Fundamental Teaching and Training Centre , South China Agricultural University , Guangzhou , Guangdong Province , China
| |
Collapse
|
4
|
Alemayehu DB, Jeng YR. Three-Dimensional Finite Element Investigation into Effects of Implant Thread Design and Loading Rate on Stress Distribution in Dental Implants and Anisotropic Bone. MATERIALS 2021; 14:ma14226974. [PMID: 34832374 PMCID: PMC8624479 DOI: 10.3390/ma14226974] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 11/06/2021] [Accepted: 11/16/2021] [Indexed: 12/18/2022]
Abstract
Variations in the implant thread shape and occlusal load behavior may result in significant changes in the biological and mechanical properties of dental implants and surrounding bone tissue. Most previous studies consider a single implant thread design, an isotropic bone structure, and a static occlusal load. However, the effects of different thread designs, bone material properties, and loading conditions are important concerns in clinical practice. Accordingly, the present study performs Finite Element Analysis (FEA) simulations to investigate the static, quasi-static and dynamic response of the implant and implanted bone material under various thread designs and occlusal loading directions (buccal-lingual, mesiodistal and apical). The simulations focus specifically on the von Mises stress, displacement, shear stress, compressive stress, and tensile stress within the implant and the surrounding bone. The results show that the thread design and occlusal loading rate have a significant effect on the stress distribution and deformation of the implant and bone structure during clinical applications. Overall, the results provide a useful insight into the design of enhanced dental implants for an improved load transfer efficiency and success rate.
Collapse
Affiliation(s)
- Dawit-Bogale Alemayehu
- Department of Biomedical Engineering, National Cheng Kung University (NCKU), Tainan 70101, Taiwan;
| | - Yeau-Ren Jeng
- Department of Biomedical Engineering, National Cheng Kung University (NCKU), Tainan 70101, Taiwan;
- School of Smart Semiconductor and Sustainable Manufacturing, National Cheng Kung University (NCKU), Tainan 70101, Taiwan
- Medical Device Innovation Center (MDIC), National Cheng Kung University (NCKU), Tainan 70101, Taiwan
- Correspondence: ; Tel.: +886-933278212
| |
Collapse
|
5
|
Chang Y, Tambe AA, Maeda Y, Wada M, Gonda T. Finite element analysis of dental implants with validation: to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process. Int J Implant Dent 2018. [PMID: 29516219 PMCID: PMC5842167 DOI: 10.1186/s40729-018-0119-5] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
A literature review of finite element analysis (FEA) studies of dental implants with their model validation process was performed to establish the criteria for evaluating validation methods with respect to their similarity to biological behavior. An electronic literature search of PubMed was conducted up to January 2017 using the Medical Subject Headings “dental implants” and “finite element analysis.” After accessing the full texts, the context of each article was searched using the words “valid” and “validation” and articles in which these words appeared were read to determine whether they met the inclusion criteria for the review. Of 601 articles published from 1997 to 2016, 48 that met the eligibility criteria were selected. The articles were categorized according to their validation method as follows: in vivo experiments in humans (n = 1) and other animals (n = 3), model experiments (n = 32), others’ clinical data and past literature (n = 9), and other software (n = 2). Validation techniques with a high level of sufficiency and efficiency are still rare in FEA studies of dental implants. High-level validation, especially using in vivo experiments tied to an accurate finite element method, needs to become an established part of FEA studies. The recognition of a validation process should be considered when judging the practicality of an FEA study.
Collapse
Affiliation(s)
- Yuanhan Chang
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Abhijit Anil Tambe
- Mahatma Gandhi Vidyamandir's Karmaveer Bhausaheb Hiray Dental College & Hospital, Mumbai Agra Road, Panchwati, Nashik, Maharashtra, India
| | - Yoshinobu Maeda
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Masahiro Wada
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tomoya Gonda
- Department of Prosthodontics, Gerodontology and Oral Rehabilitation, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
6
|
Wang J, Zhang J, Lin J, Li W, Dai H, Hu H. Performance Analysis of a Fiber Reinforced Plastic Oil Cooler Cover Considering the Anisotropic Behavior of the Fiber Reinforced PA66. Polymers (Basel) 2016; 8:polym8090312. [PMID: 30974599 PMCID: PMC6432006 DOI: 10.3390/polym8090312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 08/06/2016] [Accepted: 08/09/2016] [Indexed: 11/23/2022] Open
Abstract
In this paper, a simulation method based on an orthogonal anisotropic material is proposed. A numerical example using a simple plate is presented to show the difference in the static performance between the orthogonal anisotropic and the isotropic models. Comparing with the tested modal data of a diesel engine oil cooler cover made by glass fiber reinforced polyamide 66 (PA66), the proposed simulation method was confirmed to be much closer to reality than the general isotropic model. After that, a comprehensive performance comparison between the plastic oil cooler covers with the orthogonal anisotropic and the isotropic fiber orientations was carried out including a static deformation and stress analysis under a pressure-temperature coupled load, a forced response analysis, and an acoustic analysis under real operating conditions. The results show that the stress, the deformation, the peak vibration velocity, and the overall sound power level of the orthogonal anisotropic model are different from that obtained with the isotropic model. More importantly, the proposed method can provide a much more detailed frequency content compared to the isotropic model.
Collapse
Affiliation(s)
- Jian Wang
- State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China.
| | - Junhong Zhang
- State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China.
- Department of Mechanical Engineering, Tianjin University Renai College, Tianjin 301636, China.
| | - Jiewei Lin
- State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China.
| | - Weidong Li
- State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China.
| | - Huwei Dai
- State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China.
| | - Huan Hu
- State Key Laboratory of Engines, Tianjin University, Tianjin 300072, China.
| |
Collapse
|
7
|
Influence of Trabecular Bone on Peri-Implant Stress and Strain Based on Micro-CT Finite Element Modeling of Beagle Dog. BIOMED RESEARCH INTERNATIONAL 2016; 2016:3926941. [PMID: 27403424 PMCID: PMC4923539 DOI: 10.1155/2016/3926941] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Accepted: 05/22/2016] [Indexed: 11/18/2022]
Abstract
The objective of this investigation is to analyze the influence of trabecular microstructure modeling on the biomechanical distribution of the implant-bone interface. Two three-dimensional finite element mandible models, one with trabecular microstructure (a refined model) and one with macrostructure (a simplified model), were built. The values of equivalent stress at the implant-bone interface in the refined model increased compared with those of the simplified model and strain on the contrary. The distributions of stress and strain were more uniform in the refined model of trabecular microstructure, in which stress and strain were mainly concentrated in trabecular bone. It was concluded that simulation of trabecular bone microstructure had a significant effect on the distribution of stress and strain at the implant-bone interface. These results suggest that trabecular structures could disperse stress and strain and serve as load buffers.
Collapse
|
8
|
The influence of bone density and anisotropy in finite element models of distal radius fracture osteosynthesis: Evaluations and comparison to experiments. J Biomech 2015; 48:4116-4123. [PMID: 26542787 DOI: 10.1016/j.jbiomech.2015.10.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Revised: 10/07/2015] [Accepted: 10/10/2015] [Indexed: 11/23/2022]
Abstract
Continuum-level finite element (FE) models can be used to analyze and improve osteosynthesis procedures for distal radius fractures (DRF) from a biomechanical point of view. However, previous models oversimplified the bone material and lacked thorough experimental validation. The goal of this study was to assess the influence of local bone density and anisotropy in FE models of DRF osteosynthesis for predictions of axial stiffness, implant plate stresses, and screw loads. Experiments and FE analysis were conducted in 25 fresh frozen cadaveric radii with DRFs treated by volar locking plate osteosynthesis. Specimen specific geometries were captured using clinical quantitative CT (QCT) scans of the prepared samples. Local bone material properties were computed based on high resolution CT (HR-pQCT) scans of the intact radii. The axial stiffness and individual screw loads were evaluated in FE models, with (1) orthotropic inhomogeneous (OrthoInhom), (2) isotropic inhomogeneous (IsoInhom), and (3) isotropic homogeneous (IsoHom) bone material and compared to the experimental axial stiffness and screw-plate interface failures. FE simulated and experimental axial stiffness correlated significantly (p<0.0001) for all three model types. The coefficient of determination was similar for OrthoInhom (R(2)=0.807) and IsoInhom (R(2)=0.816) models but considerably lower for IsoHom models (R(2)=0.500). The peak screw loads were in qualitative agreement with experimental screw-plate interface failure. Individual loads and implant plate stresses of IsoHom models differed significantly (p<0.05) from OrthoInhom and IsoInhom models. In conclusion, including local bone density in FE models of DRF osteosynthesis is essential whereas local bone anisotropy hardly effects the models׳ predictive abilities.
Collapse
|