• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4611481)   Today's Articles (2623)   Subscriber (49382)
For: Montalvão D, Alçada FS, Braz Fernandes FM, de Vilaverde-Correia S. Structural characterisation and mechanical FE analysis of conventional and M-Wire Ni-Ti alloys used in endodontic rotary instruments. ScientificWorldJournal 2014;2014:976459. [PMID: 24574937 PMCID: PMC3918393 DOI: 10.1155/2014/976459] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2013] [Accepted: 10/27/2013] [Indexed: 11/21/2022]  Open
Number Cited by Other Article(s)
1
Chien PYH, Walsh LJ, Peters OA. Finite element analysis of rotary nickel-titanium endodontic instruments: A critical review of the methodology. Eur J Oral Sci 2021;129:e12802. [PMID: 34105190 DOI: 10.1111/eos.12802] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 05/03/2021] [Accepted: 05/04/2021] [Indexed: 11/30/2022]
2
Fu HY, Wang FF, Hou XM. [Construction and mechanical analysis of finite element model for bending property of controlled memory wire nickel-titanium rotary file]. JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2019;51:131-135. [PMID: 30773557 DOI: 10.19723/j.issn.1671-167x.2019.01.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
3
Comparison between Single-file Rotary Systems: Part 1—Efficiency, Effectiveness, and Adverse Effects in Endodontic Retreatment. J Endod 2018;44:1720-1724. [DOI: 10.1016/j.joen.2018.07.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 07/13/2018] [Accepted: 07/26/2018] [Indexed: 11/19/2022]
4
Both operator and heat treatment determine the centring ability of Reciproc® files in vitro. Clin Oral Investig 2018;23:697-706. [DOI: 10.1007/s00784-018-2486-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 05/07/2018] [Indexed: 10/16/2022]
5
Dosanjh A, Paurazas S, Askar M. The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments. J Endod 2017;43:823-826. [DOI: 10.1016/j.joen.2016.12.026] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 12/23/2016] [Accepted: 12/30/2016] [Indexed: 11/26/2022]
6
Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals. ScientificWorldJournal 2016;2016:1606013. [PMID: 28054031 PMCID: PMC5178357 DOI: 10.1155/2016/1606013] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 11/13/2016] [Indexed: 11/17/2022]  Open
7
Maia Filho EM, Dos Reis Santos RM, Lima DM, da Silva Pereira SM, Soares JA, de Jesus Tavarez RR, Ferreira MC, Carvalho CN, Bandeca MC, Tonetto MR, Borges AH, de Castro Rizzi C. Shaping Ability of ProTaper Next, WaveOne, and Reciproc in Simulated Root Canals. J Contemp Dent Pract 2016;17:902-906. [PMID: 27965498 DOI: 10.5005/jp-journals-10024-1951] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
8
El-Anwar MI, Yousief SA, Kataia EM, El-Wahab TMA. Finite Element Study on Continuous Rotating versus Reciprocating Nickel-Titanium Instruments. Braz Dent J 2016;27:436-41. [DOI: 10.1590/0103-6440201600480] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Accepted: 05/17/2016] [Indexed: 09/02/2023]  Open
9
Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis. ScientificWorldJournal 2016;2016:7617493. [PMID: 27314059 PMCID: PMC4893430 DOI: 10.1155/2016/7617493] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Revised: 04/25/2016] [Accepted: 05/03/2016] [Indexed: 11/17/2022]  Open
10
A study on the influence of Ni–Ti M-Wire in the flexural fatigue life of endodontic rotary files by using Finite Element Analysis. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014;40:172-9. [DOI: 10.1016/j.msec.2014.03.061] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 02/03/2014] [Accepted: 03/07/2014] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA