1
|
Guo C, Tian F, Ren D, Gao Y, Wang T. Compound electrolyte intraocular irrigating solution produces better effects on vision recovery of cataract patients after surgery than Ringer lactate solution. Int Ophthalmol 2024; 44:233. [PMID: 38886282 DOI: 10.1007/s10792-024-03131-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 04/11/2024] [Indexed: 06/20/2024]
Abstract
PURPOSE Intraocular irrigating solution is extensively applied in cataract surgery. This paper explored the difference and relationship between optical coherence tomography (OCT) and optical quality analysis system (OQAS) parameters induced by compound electrolyte intraocular irrigating solution (CEIIS) or Ringer lactate (RL) solution during uncomplicated cataract surgery. METHODS Totally 200 senior cataract patients were randomly divided into the CEIIS and RL groups (N = 100 patients/group). The anterior chamber was irrigated by CEIIS or RL during phacoemulsification. Patients were subdivided into diabetes mellitus (DM)+ and DM- groups. The central macular thickness (CMT), hyper reflective foci (HF), modulation transfer function cutoff frequency (MTF cutoff), Strehl ratio (SR), objective scatter index (OSI), and OQAS values (OVs) at 100%, 20%, and 9% contrast levels were measured preoperatively and 1 day and 1 week after operation using spectral-domain optical coherence tomography and OQAS II, respectively. Best-corrected visual acuity (BCVA) was assessed using the Snellen scale, followed by statistical analysis of its logarithm of the minimal angle of resolution. RESULTS There were no significant differences in clinical characteristics between the CEIIS and RL groups. Both groups exhibited notably increased postoperative CMT, MTF cutoff, SR, OV at 100%, 20%, and 9% contrast levels, and reduced OSI, indicating CEIIS and RL improved postoperative visual quality. CEIIS surpassed RL solution in improving postoperative visual quality, decelerating the increase of macular HF numbers and CMT in DM+ patients and postoperative BCVA. There was no difference between CEIIS and RL in long-term vision improvement. CONCLUSION CEIIS surpasses RL in postoperative visual recovery and retards increases of macular HF numbers and CMT in senior DM+ cataract patients.
Collapse
Affiliation(s)
- Chen Guo
- Department of Cataract, Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, 251 Fukang Road, Nankai District, Tianjin, 300000, China
| | - Fang Tian
- Department of Cataract, Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, 251 Fukang Road, Nankai District, Tianjin, 300000, China
| | - Dazhuang Ren
- Department of Cataract, Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, 251 Fukang Road, Nankai District, Tianjin, 300000, China
| | - Yichen Gao
- Department of Cataract, Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, 251 Fukang Road, Nankai District, Tianjin, 300000, China
| | - Tiecheng Wang
- Department of Cataract, Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, 251 Fukang Road, Nankai District, Tianjin, 300000, China.
| |
Collapse
|
2
|
Nicula CA, Nicula D, Bolboacă SD, Bulboacă AE. One year outcomes after small incision lenticule extraction ReLEX in the correction of myopia and myopic astigmatism. BMC Ophthalmol 2021; 21:423. [PMID: 34879853 PMCID: PMC8656009 DOI: 10.1186/s12886-021-02195-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 11/29/2021] [Indexed: 12/02/2022] Open
Abstract
Purpose To report the visual and refractive outcomes of small incision lenticule extraction ReLEX (SMILE) technique using VisuMax femtosecond laser in myopia and myopic astigmatism patients. Material and methods A non-randomized clinical study has been conducted on patients with myopia and myopic astigmatism who underwent ReLEX SMILE technique, using the Zeiss VisuMax Laser system (Carl Zeiss Meditec AG, Jena, Germany) at Oculens Clinic, Cluj-Napoca, Romania. Patients older than 18 years, with ocular astigmatism up to -5 diopters (D), spherical equivalent up to -10.00 D, corrected distance visual acuity (CDVA) of 0.3 or better before the surgery, stable refraction for one year, and with a minimum calculated post operator residual stromal bed of 250μ were included in the study. Results The study involved a total of 25 myopic eyes (median of sphere diopters equal with -4D) and 67 myopic astigmatic eyes (median of cylinder diopters equal with -1.5 D). The mean refractive spherical equivalent (MRSE) on patients with myopic eyes reduced from -4.25D (median) to -0.5D at one month follow-up, -0.25 D at 6 and 12 months. The mean refractive spherical equivalent (MRSE) on patients with astigmatic myopic eyes reduced from-6.25 D to -0.67 D at one month, -0.62 D at six and twelve months. The value of sphere decreased postoperatively on myopic eyes with a median of -0.25D at one, six and twelve months. The value of cylinder decreased postoperatively on myopic astigmatic eyes with a median of -0.50 D at one month, -0.25 D at six months and -0.50 D at 12 months. At 6 and 12 months, 20 (80.0%) of myopic eyes were maintained within ±0.5 D and 22 (88.0%) with ±1D. On both groups (myopic eyes and myopic astigmatic eyes), statistically significant differences were observed when the keratometric baseline values were compared to each follow-up (P-values < 0.0001), without any significant differences between follow-ups (P-values>0.15). At 1-month follow-up, uncorrected distance visual acuity (UDVA) was better than or equal to 0.5 in 88.0% of myopic eyes and 82.1% of myopic astigmatic eyes. UDVA remained stable in all cases of myopic eyes at six months and the percentage increased at 92.0% in myopic eyes. UDVA slightly increased at 6-months (85.1%) and remained at the same value at 12-months in myopic astigmatism eyes. Conclusions SMILE proved an effective and safe refractive corneal procedure and provided a predictable and stable correction of myopia and myopic astigmatism. SMILE technique demonstrated very good outcomes in terms of keratometric, cylinder, spherical measurements.
Collapse
Affiliation(s)
- Cristina Ariadna Nicula
- Department of Ophthalmology, "Iuliu Hațieganu" University of Medicine and Pharmacy, Victor Babeș Str., no. 8, 400012, Cluj-Napoca, Romania.,Oculens Clinic, Calea Turzii, No. 134-136, 400501, Cluj-Napoca, Romania
| | - Dorin Nicula
- Oculens Clinic, Calea Turzii, No. 134-136, 400501, Cluj-Napoca, Romania
| | - Sorana D Bolboacă
- Department of Medical Informatics and Biostatistics, "Iuliu Hațieganu" University of Medicine and Pharmacy, Louis Pasteur Str., no. 6, 400349, Cluj-Napoca, Romania.
| | - Adriana Elena Bulboacă
- Department of Pathophysiology, "Iuliu Hațieganu" University of Medicine and Pharmacy, Victor Babeș Str., no. 8, 400012, Cluj-Napoca, Romania
| |
Collapse
|
3
|
Chin JY, Lin MTY, Lee IXY, Mehta JS, Liu YC. Tear Neuromediator and Corneal Denervation Following SMILE. J Refract Surg 2021; 37:516-523. [PMID: 34388069 DOI: 10.3928/1081597x-20210423-01] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
PURPOSE To investigate the changes in tear neuromediators and corneal subbasal nerve plexus following small incision lenticule extraction (SMILE) and to study its association with different refractive power of corrections. METHODS Thirty patients were included for tear neuromediator analysis (40 eyes) and corneal nerve analysis using in vivo confocal microscopy scans (20 eyes). Tear samples were collected preoperatively and 1 week and 1, 3, 6, and 12 months postoperatively and analyzed for the substance P, calcitonin gene-related peptide (CGRP), and nerve growth factor (NGF) concentrations using the enzyme-linked immunosor-bent assay (ELISA). RESULTS Corneal nerve fiber density (CNFD), corneal nerve fiber length (CNFL), and corneal nerve branch density (CNBD) decreased significantly postoperatively, then gradually increased from 3 months onward, but did not recover to the baseline levels at 12 months. Tear substance P and CGRP levels remained stable over 12 months. Tear NGF levels demonstrated a small peak at 1 week before decreasing significantly compared to preoperative levels at 6 months (P = .03) and 12 months (P = .007). The 1-month reduction in CNFL, tear substance P, and CGRP concentrations were significantly correlated with the corrected spherical equivalent (SE) (r = 0.71 for CNFL; r = -0.33 to -0.52 at different time points for substance P and CGRP, respectively, all P < .05). Compared to the low to moderate myopia group, the high myopia group (corrected SE greater than -6.00 diopters) had a significantly greater decrease in CNFD, significantly higher tear substance P concentrations at 1 week, 1 month, and 6 months, and significantly higher tear CGRP concentrations at 1 and 6 months. CONCLUSIONS These results provide new insight into the neurobiological responses and their potential implications in corneal nerve damage and recovery after SMILE. High myopia treatment was associated with greater corneal denervation and neuroinflammation. [J Refract Surg. 2021;37(8):516-523.].
Collapse
|
4
|
Tay E, Bajpai R. Visual recovery after small incision lenticule extraction (SMILE) in relation to pre-operative spherical equivalent. Graefes Arch Clin Exp Ophthalmol 2020; 259:1053-1060. [PMID: 33047249 DOI: 10.1007/s00417-020-04954-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/16/2020] [Accepted: 09/25/2020] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To assess visual recovery after small incision lenticule extraction (SMILE) in relation to pre-operative spherical equivalent. METHODS Two hundred fourteen eyes of 107 patients were enrolled. Following surgery, patients were examined pre-operatively, 1 day, 2 weeks, 1 month and 3 months later. High myopia was defined as pre-operative spherical equivalent ≤ - 5 D. A linear mixed-effects model was used. RESULTS Mean ± standard deviation pre-operative spherical equivalent was - 5.30 ± 1.36 D that reduced significantly to 0.04 ± 0.70 D (p < 0.001) at 1 month and - 0.02 ± 0.66 D (p < 0.001) at 3 months. Mean pre-operative LogMAR uncorrected distance visual acuity ± SD was 0.97 ± 0.09 that improved significantly to 0.04 ± 0.06 at 2 weeks (p < 0.001), 0.01 ± 0.04 at 1 month (p < 0.001) and 0.01 ± 0.04 at 3 months (p < 0.001). Eighty-eight eyes (41.2%) had uncorrected distance visual acuities of 0.0 at 1 day, 154 eyes (72.0%) at 2 weeks,194 eyes (90.7%) at 1 month and 199 eyes (93.0%) at 3 months. Significantly more eyes with low myopia (> - 5 D) achieved acuities of 0.0 at 1 day and 2 weeks (p = 0.041 and p < 0.001). Post-operative acuities were not associated with refractive targets, laser cut energy settings or other variables. Two hundred nine eyes (97.7%) were within ± 0.5 D of target and 213 eyes (99.5%) were within ± 1 D. CONCLUSIONS SMILE for low myopia had faster visual recovery in the early post-operative period with no significant differences between groups detected by 1 and 3 months.
Collapse
Affiliation(s)
- Eugene Tay
- Singapore Eye Research Institute, The Academia, 20 College Road, Singapore, 169856, Singapore.
| | - Ram Bajpai
- School of Primary, Community and Social Care, Keele University, Keele, Staffordshire, ST5 5BG, UK
| |
Collapse
|
5
|
Effect of corneal stromal pocket irrigation in small-incision lenticule extraction. Eye (Lond) 2020; 34:2328-2335. [PMID: 32157182 PMCID: PMC7784961 DOI: 10.1038/s41433-020-0840-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 02/26/2020] [Accepted: 02/28/2020] [Indexed: 11/24/2022] Open
Abstract
Objectives To investigate the effect of corneal stromal pocket irrigation after small-incision lenticule extraction (SMILE) on visual acuity, intraocular pressure (IOP), corneal parameters and complications after surgery. Methods A total of 242 eyes of 121 patients undergoing SMILE were enrolled in this prospective controlled study, and it was designed for one eye to randomly undergo SMILE with balanced salt solution irrigation of the corneal stromal pocket, while the other eye was not. The uncorrected distance visual acuity (UDVA) and slit lamp examination were recorded at 1 hour, 1 day, 1 week, and 1 month. Postoperative corneal density, corneal biomechanical, corneal endothelial cell number, and anterior OCT images were compared at 1 day, 1 week, and 1 month. Results Compared with the nonirrigation group, the irrigation group showed significantly higher UDVA at 1 day postoperatively (P < 0.05), but there was no significant difference during the rest of the postoperative period (1 hour, 1 week, and 1 month). In addition, no significant differences were found in IOP, corneal density, corneal biomechanics, corneal endothelial cells, and corneal morphology. No visual decline or severe postoperative complications were found in the patients in this study. Conclusions Interlamellar irrigation did not affect IOP, corneal parameters, morphology, complications, or UDVA at 1 hour, 1 week, and 1 month after the operation, but it may promote UDVA 1 day after the operation.
Collapse
|
6
|
Fluctuation in straylight measurements during the visual recovery phase after small incision lenticule extraction. Eye (Lond) 2019; 34:366-373. [PMID: 31399702 DOI: 10.1038/s41433-019-0552-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Revised: 05/11/2019] [Accepted: 06/14/2019] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To investigate the postoperative straylight changes during the visual recovery phase after small incision lenticule extraction (SMILE) and their association. METHODS Seventy consecutive eyes from 37 patients with a mean age of 30.92 ± 7.26 years and a mean preoperative spherical equivalent of -5.24 ± 1.90 dioptres undergoing myopic or myopic astigmatism SMILE correction were included in this prospective study. Patients were followed up at days 1, 3, 7, 14, 21 and 28 after standard SMILE. Straylight was measured using the C-Quant straylight meter (Oculus GmbH, Germany) preoperatively and at each postoperative visit. RESULTS Preoperatively, the mean straylight measurement was 1.16 ± 0.16. After SMILE, the mean straylight values were 1.12 ± 0.14 and 1.13 ± 0.13 at days 7 and 14, which were significantly reduced compared to preoperative values (p ≤ 0.028). Straylight returned to baseline by week 3 (p = 0.160) and remained stable onwards (p = 0.651). A lower ablation ratio was associated with less straylight level at days 1, 3, 14 and 21 (p ≤ 0.0497) in the multivariable regression model. Likewise, better visual acuity was associated with lower straylight at days 7, 14 and 28 postoperatively (p ≤ 0.038). A small proportion of eyes (range: 0-12.86%) had ≥0.30 log(s) increase in postoperative straylight within the first month after SMILE. CONCLUSIONS SMILE induced a temporary decrease in straylight. It gradually returned to the preoperative level, which could be related to a number of dynamic processes during corneal healing. In the small proportion of patients with an increase in straylight postoperatively, this can affect their visual recovery during the early postoperative period.
Collapse
|
7
|
Liu YC, Teo EPW, Ang HP, Seah XY, Lwin NC, Yam GHF, Mehta JS. Biological corneal inlay for presbyopia derived from small incision lenticule extraction (SMILE). Sci Rep 2018; 8:1831. [PMID: 29382905 PMCID: PMC5789881 DOI: 10.1038/s41598-018-20267-7] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Accepted: 01/15/2018] [Indexed: 01/06/2023] Open
Abstract
Corneal inlays are a relatively new treatment option for presbyopia. Using biological inlays, derived from lenticules extracted from small incision lenticule extraction, may offer advantages over commercialized synthetic inlays in the aspect of biocompatibility. We conducted a non-human primate study to evaluate the safety, predictability, efficacy and tissue response after autogeneic, decellularized xenogeneic and xenogeneic lenticule implantation. The lenticule implantation effectively resulted in central corneal steepening (simulated keratometric values increased by 1.8–2.3 diopters), central hyper-prolate changes (asphericity Q values changed by −0.26 to −0.36), corneal anterior surface elevation (7.7–9.3 μm) and reasonable effective zone (1.5–1.8 times of the lenticule physical diameter), with no differences among the three groups. Slit lamp microscopy, transmission electron microscopy, confocal microscopy, histology and immunohistochemistry analyses confirmed the biocompatibility of the autogeneic and decellularized lenticules, whereas one eye in the xenogeneic group developed corneal stromal rejection during the study period. Our results showed that lenticule implantation has the potential for the management of presbyopia, and provide the basis for future clinical studies. The decellularization process may increase the potential utilization of lenticules without changing the efficacy.
Collapse
Affiliation(s)
- Yu-Chi Liu
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore.,Singapore National Eye Centre, Singapore, Singapore.,Duke-NUS Graduate Medical School, Singapore, Singapore
| | - Ericia Pei Wen Teo
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Heng Pei Ang
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Xin Yi Seah
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Nyein Chan Lwin
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Gary Hin Fai Yam
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Jodhbir S Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore, Singapore. .,Singapore National Eye Centre, Singapore, Singapore. .,Duke-NUS Graduate Medical School, Singapore, Singapore. .,School of Material Science & Engineering and School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore.
| |
Collapse
|
8
|
Abstract
To evaluate intraoperative decentration from pupil center and kappa intercept during small incision lenticule extraction (SMILE) and its impact on visual outcomes.This was a retrospective noncomparative case series. A total of 164 eyes that underwent SMILE at the Singapore National Eye Center were included. Screen captures of intraoperative videos were analyzed. Preoperative and 3 month postoperative vision and refractive data were analyzed against decentration.The mean preoperative spherical equivalent (SE) was -5.84 ± 1.77. The mean decentration from the pupil center and from kappa intercept were 0.13 ± 0.06 mm and 0.47mm ± 0.25 mm, respectively. For efficacy and predictability, 69.6% and 95.0% of eyes achieved a visual acuity (VA) of 20/20 and 20/30, respectively, while 83.8% and 97.2% of eyes were within ±0.5D and ±1.0D of the targeted SE. When analyzed across 3 groups of decentration from the pupil center (<0.1 mm, 0.1-0.2 mm, and >0.2 mm), there was no statistically significant association between decentration, safety, efficacy, and predictability. When analyzed across 4 groups of decentration from kappa intercept (<0.2 mm, 0.2-<0.4 mm, 0.4-<0.6 mm, and ≥0.6 mm), there was a trend toward higher efficacy for eyes with decentration of kappa intercept between 0.4 and <0.6 mm (P = .097). A total of 85.4% of eyes in the 0.4 to <0.6 mm group had unaided distance VA of 20/20 or better, as compared to only 57.8% of eyes in ≥0.6 mm group.Decentration of 0.13 mm from the pupil center does not result in compromised visual outcomes. Decentration of greater than 0.6 mm from the kappa intercept may result in compromised visual outcomes. There was a trend toward better efficacy in eyes which had decentered treatment from 0.4 to <0.6 mm from the kappa intercept. Patients with a large kappa intercept (>0.6 mm) should have their lenticule created 0.4 to 0.6 mm from the kappa intercept and not close to the pupil.
Collapse
Affiliation(s)
- John X. Wong
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | - Elizabeth P. Wong
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | | | - Jodhbir S. Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute
- Singapore National Eye Centre, Singapore
- Department of Clinical Sciences, Duke-NUS Graduate Medical School
- School of Material Science and Engineering and School of Mechanical and Aerospace Engineering, Nanyang Technological University
| |
Collapse
|
9
|
Konstantopoulos A, Liu YC, Teo EPW, Lwin NC, Yam GHF, Mehta JS. Early wound healing and refractive response of different pocket configurations following presbyopic inlay implantation. PLoS One 2017; 12:e0172014. [PMID: 28235010 PMCID: PMC5325226 DOI: 10.1371/journal.pone.0172014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 01/29/2017] [Indexed: 11/25/2022] Open
Abstract
Background Presbyopic inlays have mostly been implanted under a corneal flap. Implantation in a pocket has advantages including less postoperative dry eye and neurotrophic effect, and better biomechanical corneal stability. This study investigated the effect of different pocket and flocket dimensions on corneal stability and refractive power after Raindrop™ implantation, and the associated wound healing response. Methodology Ten New Zealand White rabbits had bilateral pocket Raindrop™ implantation. Eyes were allocated to 4 groups: pockets with 4mm, 6mm, and 8mm diameters, and 8mm flocket. They were examined pre-operatively, at day 1, weeks 1, 2, 3 and 4 post-surgery with anterior segment optical coherence tomography, corneal topography and in-vivo confocal microscopy. After euthanasia (week 4), CD11b, heat shock protein (HSP) 47 and fibronectin corneal immunohistochemistry was performed. Results Corneal thickness (mean±SD) increased from 360.0±16.2μm pre-operatively to 383.9±32.5, 409.4±79.3, 393.6±35.2, 396.4±50.7 and 405±20.3μm on day 1, weeks 1,2,3 and 4 respectively (p<0.008, all time-points). Corneal refractive power increased by 11.1±5.5, 7.5±2.5, 7.5±3.1, 7.0±3.6 and 6.3±2.9D (p<0.001). Corneal astigmatism increased from 1.1±0.3D to 2.3±1.6, 1.7±0.7, 1.8±1.0, 1.6±0.9 and 1.6±0.9D respectively (p = 0.033). CT, refractive power change and astigmatism were not different between groups. The 8mm pocket and 8mm flocket groups had the least stromal keratocyte reflectivity. CD11b, fibronectin or HSP47 weren’t detected. Conclusions Anatomical and refractive stability was achieved by 1 week; the outcomes were not affected by pocket or flocket configuration. No scarring or inflammation was identified. The 8mm pocket and flocket showed the least keratocyte activation, suggesting they might be the preferred configuration.
Collapse
Affiliation(s)
- Aris Konstantopoulos
- Singapore Eye Research Institute, Singapore, Singapore
- Singapore National Eye Centre, Singapore, Singapore
- University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom
| | - Yu-Chi Liu
- Singapore Eye Research Institute, Singapore, Singapore
- Singapore National Eye Centre, Singapore, Singapore
| | | | | | | | - Jodhbir S. Mehta
- Singapore Eye Research Institute, Singapore, Singapore
- Singapore National Eye Centre, Singapore, Singapore
- Department of Clinical Sciences, Duke-NUS Graduate Medical School, Singapore, Singapore
- Nanyang Technological University, Singapore, Singapore
- * E-mail:
| |
Collapse
|
10
|
Liu YC, Ang HP, Teo EPW, Lwin NC, Yam GHF, Mehta JS. Wound healing profiles of hyperopic-small incision lenticule extraction (SMILE). Sci Rep 2016; 6:29802. [PMID: 27418330 PMCID: PMC4945911 DOI: 10.1038/srep29802] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Accepted: 06/20/2016] [Indexed: 12/14/2022] Open
Abstract
Refractive surgical treatment of hyperopia still remains a challenge for refractive surgeons. A new nomogram of small incision lenticule extraction (SMILE) procedure has recently been developed for the treatment of hyperopia. In the present study, we aimed to evaluate the wound healing and inflammatory responses of this new nomogram (hyperopic-SMILE), and compared them to those of hyperopic-laser-assisted in situ keratomileusis (LASIK), using a rabbit model. A total of 26 rabbits were used, and slit lamp biomicroscopy, autorefractor/keratometer, intraocular pressure measurement, anterior segment optical coherence tomography, corneal topography, and in vivo confocal microscopy examinations were performed during the study period of 4 weeks. The corneas were then harvested and subject to immunofluorescence of markers for inflammation (CD11b), wound healing (fibronectin) and keratocyte response (HSP47). The lenticule ultrastructual changes were also analyzed by transmission electron microscopy. Out results showed that hyperopic-SMILE effectively steepened the cornea. Compared to hyperopic-LASIK, hyperopic-SMILE had less postoperative wound healing response and stromal interface reaction, especially in higher refractive correction. However, compared to myopic-SMILE, hyperopic-SMILE resulted in more central deranged collagen fibrils. These results provide more perspective into this new treatment option for hyperopia, and evidence for future laser nomogram modification.
Collapse
Affiliation(s)
- Yu-Chi Liu
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore.,Singapore National Eye Centre, 11 Third Hospital Ave, Singapore
| | - Heng Pei Ang
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Ericia Pei Wen Teo
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Nyein Chan Lwin
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Gary Hin Fai Yam
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Jodhbir S Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore.,Singapore National Eye Centre, 11 Third Hospital Ave, Singapore.,Department of Clinical Sciences, Duke-NUS Graduate Medical School, Singapore.,School of Material Science &Engineering and School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave, n3, 639798, Singapore
| |
Collapse
|