1
|
Thanoon H, Price RB, Watts DC. Thermography and conversion of fast-cure composite photocured with quad-wave and laser curing lights compared to a conventional curing light. Dent Mater 2024; 40:546-556. [PMID: 38326211 DOI: 10.1016/j.dental.2024.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 01/24/2024] [Accepted: 01/25/2024] [Indexed: 02/09/2024]
Abstract
OBJECTIVES This study investigated effects of the different emittance-mode protocols from three light curing units (LCUs): (i) a Laser (Monet); (ii) a quad-wave (PinkWave); (iii) a conventional LED (Elipar S10) on the temperature rise (ΔT) and degree of conversion (DC) when photo-curing fast or conventional bulk-fill resin-based composites (RBC). The aim was to correlate ΔT and DC, and the radiant exposure delivered to RBC specimens. METHODS A 3D-printed resin mold of 4 mm depth was filled with two bulk-fill RBCs: Tetric PowerFill® (fast photo-polymerised composite) (TPF) or Tetric EvoCeram® Bulk-Fill (EVO). Three LCUs were used: (i) Monet laser for 1 s and 3 s (MONET-1 s, MONET-3 s); (ii) PinkWave quad-wave used for 3 s in Boost mode (PW-3 s) and for 20 s in standard mode (PW-20 s); (iii) Elipar S10 for 5 s (S10-5 s) and for 20 s in standard mode (S10-20 s). 2-dimensional temperature maps were obtained before, during and for 60 s after the LCU had turned off using a thermal imaging camera. Thermal changes were analysed at five depths: (0, 1, 2, 3, and 4 mm from the top surface of the RBC). The maximum temperature rise (Tmax) and the mean temperature rise (ΔT) were determined. Cylindrical-shaped specimens were prepared from each material using a stainless-steel split mold (4 × 4 mm) and light-cured with the same protocols. The DC was measured for 120 s and at 1 h after LCU had turned off using Fourier Transform Infrared Spectroscopy (FTIR). Data were analysed using Three-way ANOVA, One-way ANOVA, independent t-tests, and Tukey post-hoc tests (p < 0.05). RESULTS Radiant exposures delivered by the various irradiation protocols were between 4.5-30.3 J/cm2. Short exposure times from MONET-1 s and PW-3 s delivered the lowest radiant exposures (4.5 and 5.2 J/cm2, respectively) and produced the lowest ΔT and DC. The longer exposure times in the standard modes of PW-20 s, S10-20 s, and MONET-3 s produced the highest Tmax, ΔT, and DC for both composites. The ΔT range among composites at different depths varied significantly (31.7-49.9 °C). DC of TPF ranged between 30-65% and in EVO between 15.3-56%. TPF had higher Tmax, ΔT for all depths and DC compared to EVO, across the LCU protocols (p < 0.05), except for PW-20 s and MONET-3 s. The coronal part of the restorations (1-2 mm) had the highest ΔT. There was a positive correlation between ΔT and DC at 4-mm depth after 120 s SIGNIFICANCE: Longer, or standard, exposure times of the LCUs delivered greater radiant exposures and had higher DC and ΔT compared to shorter or high-irradiance protocols. The fast photo-polymerised RBC had comparatively superior thermal and conversion outcomes when it received a high irradiance for a short time (1-5 s) compared to the conventional Bulk-Fill RBC.
Collapse
Affiliation(s)
- Halah Thanoon
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dentistry, College of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
| | - Richard B Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - David C Watts
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Photon Science Institute, University of Manchester, Manchester, UK.
| |
Collapse
|
2
|
Alsunbul H, Khan AA, Alqahtani YM, Hassan SAB, Asiri W, Saadaldin S, Alharthi R, Aldegheishem A. Using Functionalized Micron-Sized Glass Fibres for the Synergistic Effect of Glass Ionomer on Luting Material. J Funct Biomater 2023; 14:550. [PMID: 37998119 PMCID: PMC10672604 DOI: 10.3390/jfb14110550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 11/09/2023] [Accepted: 11/14/2023] [Indexed: 11/25/2023] Open
Abstract
This laboratory experiment was conducted with the objective of augmenting the mechanical properties of glass ionomer cement (GIC) via altering the composition of GIC luting powder through the introduction of micron-sized silanized glass fibres (GFs). Experimental GICs were prepared through the addition of two concentrations of GFs (0.5% and 1.0% by weight) to the powder of commercially available GIC luting materials. The effect of GF in set GIC was internally evaluated using micro-CT while the mechanical attributes such as nano hardness (nH), elastic modulus (EM), compressive strength (CS), and diametral tensile strength (DTS) were gauged. Additionally, the physical properties such as water solubility and sorption, contact angle (CA), and film thickness were evaluated. Reinforced Ketac Cem Radiopaque (KCR) GIC with 0.5 wt.% GF achieved improved nH, EM, CS, and DTS without affecting the film thickness, CA or internal porosity of the set GIC cement. In contrast, both GF-GIC formulations of Medicem (MC) GIC showed the detrimental effect of the GF incorporation. Reinforcing KCR GIC with 0.5 wt.% silanized GFs could improve the physical and mechanical attributes of luting material. Silanized GF, with optimal concentration within the GIC powder, can be used as a functional additive in KCR GIC with promising results.
Collapse
Affiliation(s)
- Hanan Alsunbul
- Restorative Dentistry Department, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia;
| | - Aftab Ahmed Khan
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia
| | - Yasser M. Alqahtani
- Restorative Dentistry Department, Ministry of Health, Abha 61321, Saudi Arabia;
| | - Saeed Awod bin Hassan
- Restorative Dental Sciences Department, College of Dentistry, King Khalid University, Abha 61321, Saudi Arabia;
| | - Waleed Asiri
- Restorative Dentistry Department, College of Dentistry, Najran University, Najran 66454, Saudi Arabia;
| | - Selma Saadaldin
- Prosthodontics Division, Schulich School of Medicine and Dentistry, Western University, London, ON N6A 5B9, Canada;
| | - Rasha Alharthi
- Clinical Dental Science Department, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (R.A.); (A.A.)
| | - Alhanoof Aldegheishem
- Clinical Dental Science Department, College of Dentistry, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia; (R.A.); (A.A.)
| |
Collapse
|
3
|
Cavalcanti KGBA, Pulido C, Moreira PHA, Monteles CF, Salvatierra BLC, Siqueira FSF, Soares CJ, Reis A, Loguercio AD, Cardenas AFM. Effect of irradiance and exposure time on the adhesive properties of universal adhesives after 2 years of storage. Clin Oral Investig 2023; 27:5223-5232. [PMID: 37458867 DOI: 10.1007/s00784-023-05142-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/04/2023] [Indexed: 09/10/2023]
Abstract
OBJECTIVE This study aims to evaluate the effects of exposure time and irradiance on the dentin bonding properties (microtensile bond strength (μTBS) and nanoleakage (NL)) of the Clearfil Universal Bond Quick (CUQ) adhesive and Scotchbond Universal Adhesive (SBU) immediately and after 2 years of water storage. MATERIAL AND METHODS Hence, 128 human molars were randomly assigned to 16 groups based on adhesive strategy, irradiance/exposure times, and storage time for each universal adhesive tested. The adhesives were applied using the etch-and-rinse and self-etch strategies and were light-cured using four different irradiance/exposure times: 1400 mW/cm2 for 5 s (1400 × 5), 1400 mW/cm2 for 10 s (1400 × 10), 3200 mW/cm2 for 5 s (3200 × 5), and 3200 mW/cm2 for 10 s (3200 × 10). Then, each sample was restored and sectioned into a resin-dentin bonded stick to be tested for μTBS and NL (immediately and after 2 years of water storage). The mean μTBS and NL of all resin-dentin bonded sticks from the same hemi-tooth (factor time) were statistically analyzed using a three-way ANOVA and Tukey's test (a = 0.05). RESULTS Despite a significant decrease in the μTBS values for all groups after 2 years of water storage, the 3200 × 5 group showed higher μTBS values, whereas the 3200 × 10 group showed lower μTBS values for both universal adhesives tested. Although a significant increase in the NL values was observed for all groups after 2 years of water storage, the 3200 × 10 group showed higher NL values than the other groups (p < 0.001). CONCLUSION Results indicate that light-curing the adhesive layer with 14-16 J/cm2 led to an improvement in the stability of the resin-dentin adhesive interface. A longer exposure time (10 s) coupled with a higher irradiance (3200 mW/cm2) resulted in a greater degree of degradation of the adhesive interface. CLINICAL SIGNIFICANCE To guarantee better stability of the adhesive interface, clinicians could be preferred a light-cured universal adhesive layer with 14-16 J/cm2. Higher irradiances should be avoided.
Collapse
Affiliation(s)
| | - Camilo Pulido
- Department of Restorative Dentistry and Biomaterials, San Francisco de Quito University, Quito, Ecuador
| | - Pedro H A Moreira
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Camila F Monteles
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Byron L C Salvatierra
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil
| | | | - Carlos J Soares
- Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
- Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, Ponta Grossa State University, Rua Carlos Cavalcanti, 4748, Bloco M, Sala 64A-Uvaranas, Ponta Grossa, Paraná, 84030-900, Brazil.
| | | |
Collapse
|
4
|
Lau XE, Liu X, Chua H, Wang WJ, Dias M, Choi JJE. Heat generated during dental treatments affecting intrapulpal temperature: a review. Clin Oral Investig 2023; 27:2277-2297. [PMID: 37022531 PMCID: PMC10159962 DOI: 10.1007/s00784-023-04951-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 03/14/2023] [Indexed: 04/07/2023]
Abstract
INTRODUCTION Heat is generated and transferred to the dentine-pulp complex during various dental procedures, such as from friction during cavity preparations, exothermic reactions during the polymerisation of restorative materials and when polishing restorations. For in vitro studies, detrimental effects are possible when intra-pulpal temperature increases by more than 5.5°C (that is, the intra-pulpal temperature exceeds 42.4°C). This excessive heat transfer results in inflammation and necrosis of the pulp. Despite numerous studies stating the importance of heat transfer and control during dental procedures, there are limited studies that have quantified the significance. Past studies incorporated an experimental setup where a thermocouple is placed inside the pulp of an extracted human tooth and connected to an electronic digital thermometer. METHODS This review identified the opportunity for future research and develop both the understanding of various influencing factors on heat generation and the different sensor systems to measure the intrapulpal temperature. CONCLUSION Various steps of dental restorative procedures have the potential to generate considerable amounts of heat which can permanently damage the pulp, leading to pulp necrosis, discoloration of the tooth and eventually tooth loss. Thus, measures should be undertaken to limit pulp irritation and injury during procedures. This review highlighted the gap for future research and a need for an experimental setup which can simulate pulp blood flow, temperature, intraoral temperature and intraoral humidity to accurately simulate the intraoral conditions and record temperature changes during various dental procedures.
Collapse
Affiliation(s)
- Xin Er Lau
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - Xiaoyun Liu
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - Helene Chua
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - Wendy Jingwen Wang
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - Maykon Dias
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - Joanne Jung Eun Choi
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand.
| |
Collapse
|
5
|
Maucoski C, Price RB, Arrais CAG. Temperature changes and hardness of resin-based composites light-cured with laser diode or light-emitting diode curing lights. Odontology 2023; 111:387-400. [PMID: 36184680 DOI: 10.1007/s10266-022-00745-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 09/13/2022] [Indexed: 11/25/2022]
Abstract
The temperature and Vickers Hardness (VH) at the top and bottom surfaces of three resin-based composites (RBCs) were measured when light-cured using five light-curing units (LCUs). The spectrum, power, and energy delivered to the top of the RBCs and transmitted through the RBCs were measured. Starting at 32℃, the temperature rise produced by the Monet Laser (ML-1 s and 3 s), Valo Grand (VG-3 s and 10 s), DeepCure (DC-10 s), PowerCure, (PC-3 s and 10 s) and PinkWave (PW-10 s) were measured at the bottom of specimens 2 mm deep × 6 mm wide made of Filtek Universal A2, Tetric Evoceram A2 and an experimental RBC codenamed Transcend UB. The VH values measured at the top and bottom of these RBCs were analyzed using ANOVA and Scheffe's post hoc test (p < 0.05) to determine the effects of the LCUs on the RBCs. The transmitted power from the ML was reduced by 77.4% through 2 mm of Filtek Universal, whereas light from PW decreased by only 36.8% through Transcend. The highest temperature increases from the LCU combined with the exothermic reaction occurred for Transcend, and overall, no significant differences were detected between Filtek Universal and Tetric Evoceram (p = 0.9756). Transcend achieved the highest VH values at the top and bottom surfaces. The PinkWave used for 10 s produced the largest temperature increase (20.2℃) in Transcend. The Monet used for 1 s produced the smallest increase (7.8℃) and the lowest bottom:top VH ratios.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, B3H 4R2, Canada.
- Department of Restorative Dentistry, The State University of Ponta Grossa, 4748 General Carlos Cavalcanti Av., Ponta Grossa, Parana, 84051-130, Brazil.
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, B3H 4R2, Canada
| | - Cesar Augusto Galvão Arrais
- Department of Restorative Dentistry, The State University of Ponta Grossa, 4748 General Carlos Cavalcanti Av., Ponta Grossa, Parana, 84051-130, Brazil
| |
Collapse
|
6
|
Maucoski C, Price RB, Sullivan B, Guarneri JAG, Gusso B, Arrais CAG. In-vitro pulpal temperature increases when photo-curing bulk-fill resin-based composites using laser or light-emitting diode light curing units. J ESTHET RESTOR DENT 2023; 35:705-716. [PMID: 36738181 DOI: 10.1111/jerd.13022] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/03/2023] [Accepted: 01/14/2023] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To evaluate the in vitro pulpal temperature rise (ΔT) within the pulp chamber when low- and high-viscosity bulk-fill resin composites are photo-cured using laser or contemporary light curing units (LCUs). MATERIALS AND METHODS The light output from five LCUs was measured. Non-retentive Class I and V cavities were prepared in one upper molar. Two T-type thermocouples were inserted into the pulp chamber. After the PT values reached 32°C under simulated pulp flow (0.026 mL/min), both cavities were restored with: Filtek One Bulk Fill (3 M), Filtek Bulk Fill Flow (3 M), Tetric PowerFill (Ivoclar Vivadent), or Tetric PowerFlow (Ivoclar Vivadent). The tooth was exposed as follows: Monet Laser (1 and 3 s), PowerCure (3 and 20 s), PinkWave (3 and 20 s), Valo X (5 and 20 s) and SmartLite Pro (20 s). The ΔT data were subjected to one-way ANOVA followed by Scheffe's post hoc test. RESULTS Monet 1 s (1.9 J) and PinkWave 20 s (30.1 J) delivered the least and the highest amount of energy, respectively. Valo X and PinkWave used for 20 s produced the highest ΔT values (3.4-4.1°C). Monet 1 s, PinkWave 3 s, PowerCure 3 s (except FB-Flow) and Monet 3 s for FB-One and TP-Fill produced the lowest ΔT values (0.9-1.7°C). No significant differences were found among composites. CONCLUSIONS Short 1- to 3-s exposures produced acceptable temperature rises, regardless of the composite. CLINICAL SIGNIFICANCE The energy delivered to the tooth by the LCUs affects the temperature rise inside the pulp. The short 1-3 s exposure times used in this study delivered the least amount of energy and produced a lower temperature rise. However, the RBC may not have received sufficient energy to be adequately photo-cured.
Collapse
Affiliation(s)
- Cristiane Maucoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil.,Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Braden Sullivan
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Nova Scotia, Canada
| | | | - Bruno Gusso
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Parana, Brazil
| | | |
Collapse
|
7
|
Maucoski C, Price RB, Arrais CAG, Sullivan B. In vitro temperature changes in the pulp chamber caused by laser and Quadwave LED-light curing units. Odontology 2022:10.1007/s10266-022-00780-y. [DOI: 10.1007/s10266-022-00780-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 12/06/2022] [Indexed: 12/24/2022]
|
8
|
Cardenas A, Siqueira F, Nuñez A, Nonato RF, Cavalcanti K, Soares CJ, Reis A, Loguercio AD. Influence of Irradiance and Exposure Times on the Mechanical and Adhesive Properties of Universal Adhesives with Dentin. Oper Dent 2022; 47:412-424. [PMID: 35917253 DOI: 10.2341/21-042-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/10/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated the influence of irradiance/exposure time on the Knoop hardness (KHN) and polymer cross-linking density (PCLD), as well as microtensile bond strength (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of universal adhesives. METHODS AND MATERIALS Two universal adhesive systems, Clearfil Universal Bond Quick (CUQ) and Scotchbond Universal Adhesive (SBU), were light-cured using various irradiance/exposure times: 1400 mW/cm2 for 5 s (1400*5); 1400 mW/cm2 for 10 s (1400*10); 3200 mW/cm2 for 5 s (3200*5); and 3200 mW/cm2 for 10 s (3200*10). Adhesive disks from each group were used to measure PCLD by KHN. One hundred and twenty-eight human molars were randomly assigned to 16 groups according to the following variables: adhesive system vs adhesive strategies vs radiance/exposure times. After restoration, specimens were sectioned into resin-dentin sticks and tested for μTBS, NL, and DC. The data from PCLD (%), KHN, μTBS (MPa), NL (%), and DC (%) data were subjected to ANOVA and Tukey's test (α=0.05). RESULTS Significant reductions in KHN, μTBS, and DC (p=0.00001) values and an increase in NL and PCLD (p=0.00001) values were observed for 3200*10 when compared with other groups. Higher KHN, μTBS, and DC (p=0.000001) values were observed for 3200*5 in comparison with the other groups. The 1400*5 (7 J/cm2) and 1400*10 (14 J/cm2) groups showed intermediate values (p=0.000001). CONCLUSION Although similar results in terms of hardness, polymer cross-linking density and nanoleakage were observed when 5 seconds at 3200 mW/cm2 and 10 seconds at 1400 mW/cm2 groups were compared, the use of higher irradiance (3200 mW/cm2) for only 5 seconds showed better results in terms of bond strength and degree of conversion for both universal adhesives to dentin. The prolonged exposure time (10 seconds) at the higher irradiance (3200 mW/cm2) showed the worst results.
Collapse
Affiliation(s)
- Afm Cardenas
- Andres Felipe Millan Cardenas, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Fsf Siqueira
- Fabiana Suelen Figuerêdo de Siqueira, DDS, Ms, PhD, professor, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - A Nuñez
- Alejandra Nuñez, DDS, Ms, PhD student, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, Paraná, Brazil, and Professor, Department of Restorative Dentistry and Biomaterials, San Francisco de Quito University, Quito, Ecuador
| | - R F Nonato
- Rammon de Faria Nonato, DDS, Ms student, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - Kgba Cavalcanti
- Karoline Guará Brusaca Almeida Cavalcanti, DDS, Ms, PhD student, Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil
| | - C J Soares
- Carlos José Soares, DDS, Ms, PhD, professor, Departament of Postgraduate Program in Dentistry, CEUMA University, São Luis, MA, Brazil, and Dental School, Department of Operative Dentistry and Dental Materials, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - A Reis
- *Alessandra Reis, DDS, PhD, professor, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - A D Loguercio
- Alessandro D. Loguercio, DDS, Ms, PhD, professor, Department of Restorative Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| |
Collapse
|
9
|
Aquino Valverde AJ, Aguilar Vargas GDP, Díaz Fernández JM, Leiva Ramírez PA, Quintanilla Labajos DA, Atoche Socola KJ, Vidalón Pinto M. [Light-curing effectiveness using led lamps: a review]. REVISTA CIENTÍFICA ODONTOLÓGICA 2022; 10:e120. [PMID: 38389554 PMCID: PMC10880699 DOI: 10.21142/2523-2754-1003-2022-120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 09/02/2022] [Indexed: 02/24/2024] Open
Abstract
Introduction LED lamps have a new light-curing technology which can be monowave or polywave, which allows it to reach more initiators such as camphorquinone, Lucirin TPO and Propanodione, which have a wide variety of advantages and disadvantages. These lamps have evolved over time, as have different ergonomics, longevity, systems and quality standards. Objective The objective of this literature review is to improve the clinician on the proper use of different LED lamps and how they influence the efficiency of resin photopolymerization. Material and methods Extensive research has been carried out in the existing literature on this topic. From the beginning of this information until April 18, 2022, the bibliographic search carried out includes 86 articles published in the Medline database through PubMed, LILACS, Science Direct and SciELO, and there is no language restriction. Results The photopolymerization effects of Polywave and Monowave LED lamps present significant differences between the compressive strength of the light-cured resin, with single-wave and polyvalent LED lamps where the types of light and lamp directly influence the compressive strength of the resin. composite resins. Conclusion The type of light and lamp directly affects the efficiency of the photopolymerization of the composite resin, so it is concluded that LED lamps with single wave technology (Monowave) produce a greater depth of photopolymerization than those with multiple wave technology (Polywave).
Collapse
Affiliation(s)
- Alexandra Jacqueline Aquino Valverde
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Gina Del Pilar Aguilar Vargas
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - José Miguel Díaz Fernández
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Piero Aryed Leiva Ramírez
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Daleska Adriana Quintanilla Labajos
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Katherine Joselyn Atoche Socola
- Division de Rehabilitacion Oral, Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. Universidad Científica del Perú Division de Rehabilitacion Oral Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Marcia Vidalón Pinto
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| |
Collapse
|
10
|
Wang WJ, Grymak A, Waddell JN, Choi JJE. The effect of light curing intensity on bulk-fill composite resins: heat generation and chemomechanical properties. Biomater Investig Dent 2021; 8:137-151. [PMID: 34622209 PMCID: PMC8491722 DOI: 10.1080/26415275.2021.1979981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
Objectives The aim of this study was to assess the effect of light curing intensity and wavelength spectrum on heat generation and chemomechanical properties of bulk-fill composites. Methods Four bulk-fill restorative materials (Filtek bulk-fill, Tetric PowerFill bulk-fill, Beautifil Bulk restorative and Admira Fusion X-tra were used in this study. A total of 100 cylindrical specimens of each composite (n = 25/group) were prepared, then cured using monowave light curing unit (LCU) with a single light intensity of 1470 mW/cm2, and polywave LCU with three different light intensities (1200,2100, 3050mW/cm2). The temperature change during polymerisation was measured by five K-type thermocouples placed in each 1 mm layer from top to bottom. Hardness and degree of conversion of composites at each level were evaluated. Results were statistically analysed. Results The use of polywave LCU resulted in statistically higher peak temperatures ranging between 31.4-63.5 °C compared to the temperature generated by monowave LCU ranging between 29.5-60 °C (p < .05). Curing using polywave LCU with the highest light intensity of 3050 mW/cm2 caused the highest peak temperature irrespective of the composite types. There was no significant difference in hardness with different light curing intensities and curing times, regardless of the bulk-fill resin materials (p > .05). A positive correlation was also found between the hardness and the DoC of the four bulk-fill composites. Conclusion The change in temperature during polymerisation of bulk-fill composites were found to be proportional to the increase in light curing intensity. Mechanical properties of the bulk-fill composites were dependent on the composition and the type of photoinitiators.
Collapse
Affiliation(s)
- Wendy Jingwen Wang
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Anastasiia Grymak
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - John Neil Waddell
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Joanne Jung Eun Choi
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| |
Collapse
|
11
|
Physical and chemical mechanisms involved in adhesion of orthodontic bonding composites: in vitro evaluations. BMC Oral Health 2021; 21:350. [PMID: 34271907 PMCID: PMC8285804 DOI: 10.1186/s12903-021-01715-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 07/07/2021] [Indexed: 11/10/2022] Open
Abstract
Background Bond strength of orthodontic composite is strongly influenced by molecular and structural mechanisms. Aim of this in vitro study was to compare bond strength of light-cure orthodontic composites by measuring debonding forces and evaluating locations of bond failure. Investigations on chemical compositions clarified adhesive behaviors and abilities, exploring effects of ageing processes in this junction materials. Methods Twelve enamel discs, from human premolars, were randomly coupled to one orthodontic adhesive system (Transbond XT™ 3 M UNITEK, USA, Light-Cure Orthodontic Paste, LEONE, Italy and Bisco Ortho Bracket Paste LC, BISCO, Illinois) and underwent to Shear Bond Strength test. Metallic brackets were bonded to twenty-seven human premolar, with one of the adhesive systems, to quantify, at FE-SEM magnifications, after debonding, the residual material on enamel and bracket base surfaces. Raman Spectroscopy analysis was performed on eight discs of each composites to investigate on chemical compositions, before and after accelerated aging procedures in human saliva and sugary drink. Results Orthodontic adhesive systems showed similar strength of adhesion to enamel. The breakage of adhesive-adherent bond occurs in TXT at enamel-adhesive interface while in Bisco and Leone at adhesive-bracket interface. Accelerated in vitro aging demonstrated good physical–chemical stability for all composites, Bisco only, was weakly contaminated with respect to the other materials. Conclusion A similar, clinically adequate and acceptable bond strength to enamel for debonding maneuvers was recorded in all orthodontic adhesive systems under examination. No significant chemical alterations are recorded, even in highly critical situations, not altering the initial mechanical properties of materials.
Collapse
|
12
|
Almeida R, Manarte-Monteiro P, Domingues J, Falcão C, Herrero-Climent M, Ríos-Carrasco B, Lemos BF. High-Power LED Units Currently Available for Dental Resin-Based Materials-A Review. Polymers (Basel) 2021; 13:2165. [PMID: 34208978 PMCID: PMC8271666 DOI: 10.3390/polym13132165] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/24/2021] [Accepted: 06/26/2021] [Indexed: 11/23/2022] Open
Abstract
The pursuit of less time-consuming procedures led to the development of high-power light-curing-units (LCU) to light-cure dental-resin-based-materials. This review aims to describe high-power light-emitting-diode (LED)-LCUs, by a bibliometric systematization of in vitro and in vivo studies. The research-question, by PICO model, aimed to assess the current knowledge on dentistry-based high-power LED-LCUs by analyzing to what extent their use can promote adverse events on materials and patients' oral condition when compared to low-power LED-LCUs, on daily dental practice. PubMed and B-on database search focused on high-power (≥2000 mW/cm2) LED-LCUs outputs. Studies assessing performance of high-power LED-LCUs for light-curing dental-resin-based-materials were included. From 1822 screened articles, 21 fulfilled the inclusion criteria. Thirty-two marketed units with high levels of radiant emittance (≥2000 mW/cm2 up to 6000 mW/cm2) were identified. Most output values vary on 2000-3000 mW/cm2. The highest output found was 6000 mW/cm2, in FlashMax™P3. Reports suggest that light-curing protocols with lower emittance irradiance and longer exposure outperforms all other combination, however in some clinical procedures high-power LED-LCUs are advocated when compared to low-power LED-LCUs. Moreover, long time exposures and over-curing can be dangerous to the biological vital pulp, and other oral tissues. Evidence showing that high-power LCUs are the best clinical option is still very scarce.
Collapse
Affiliation(s)
- Rita Almeida
- Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal;
| | - Patricia Manarte-Monteiro
- Department of Dentistry and Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal; (P.M.-M.); (J.D.); (C.F.); (B.F.L.)
| | - Joana Domingues
- Department of Dentistry and Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal; (P.M.-M.); (J.D.); (C.F.); (B.F.L.)
| | - Carlos Falcão
- Department of Dentistry and Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal; (P.M.-M.); (J.D.); (C.F.); (B.F.L.)
- Porto Dental Institute, 4150-518 Porto, Portugal;
| | | | | | - Bernardo Ferreira Lemos
- Department of Dentistry and Medical Sciences, Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal; (P.M.-M.); (J.D.); (C.F.); (B.F.L.)
| |
Collapse
|
13
|
Memari Trava G, Almeida Santos J, Paula Ramos L, Rosário Estevam dos Santos PB, Abu Hasna A, Yui KC, Bressane A, Dias de Oliveira L, Spalding M. The effect of halogen bulb and light-emitting diode light curing units on temperature increase and fibroblast viability. F1000Res 2020; 9:1369. [DOI: 10.12688/f1000research.25456.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
Abstract
Background: This study aimed to compare the temperature increase produced by halogen bulb (HAL) and light-emitting diode (LED) light curing units (LCUs) by irradiating dentin discs (0.5 mm and 1 mm thickness), and to evaluate their cytotoxic effects on fibroblast culture in the presence of dentin discs due to the increasing demand on resin composite restorations and teeth bleaching for esthetic purposes. Methods: A total of 20 bovine incisors were used to obtain dentin discs and divided into four experimental groups (n=10): HAL0.5: irradiation with halogen-tungsten bulb Curing Light XL 3000 at an intensity of 470 mW/cm2 over a dentin disc of 0.5 mm; LED0.5: irradiation with LED Optilight Max (GNATUS- Ribeirão Preto, SP, Brazil) at an intensity of 1200 mW/cm2 over a dentin disc of 0.5 mm; HAL1: irradiation as in HAL0.5 but over a dentin disc of 1 mm; LED1: irradiation as in LED0.5 but over a dentin disc of 1 mm. The temperature increase was measured using a digital thermometer and the cytotoxicity was evaluated using an MTT assay with a mouse fibroblast cell line (L929). Parametric Data were analyzed by ANOVA and Tukey and non-parametric data were analyzed by Kruskal Wallis with Conover-Iman for non-parametric data (all with α=0.05). Results: A significant statistical difference was found between the groups HAL0.5 and HAL1 and both were different of LED0.5 and LED1 which presented higher temperature. All the experimental groups were different of the control group (without irradiation), and promoted reduction of cellular viability. Conclusions: HAL LCU promoted a lower temperature change in the dentin compared to LED, regardless of the dentin thickness (0.5-1 mm). Both HAL and LED LCUs decreased fibroblast viability; however, LED promoted more significant cytotoxic effects.
Collapse
|
14
|
Temperatures in the pulpal cavity during orthodontic bonding using an LED light curing unit : An in vitro pilot study. J Orofac Orthop 2020; 81:396-406. [PMID: 32875349 DOI: 10.1007/s00056-020-00246-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 04/25/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE During bracket bonding, patients often report about thermosensitivity. The reason could be that modern light emitting diode (LED) light curing units run with intensities up to 3200 mW/cm2. In this in vitro pilot study with nonpulpal circulation approaches, the temperatures in the pulpal cavity were measured. METHODS The study included 60 extracted teeth divided into four equal groups: lower and upper incisors, premolars and molars. Starting at 37 °C (body temperature) as the reference, the temperature increase was measured for the first series on each tooth without a bracket, without and with a recommended hygienic barrier case for the LED light curing unit, and exposition to light once versus twice. The distance between the tooth and light curing unit was 3 mm. In the second test series, a metal bracket was also bonded to each tooth. In the third series, the light exposition distance was increased to 4 mm. RESULTS In all three test series, significant intrapulpal temperature increase was found: The highest temperatures were recorded after exposure to light once without the hygienic barrier case. In the first test series, this approach showed temperatures even higher than 42.5 °C in the lower incisors (average 42.99 ± 2.23 °C) and premolars (average 42.94 ± 2.15 °C). CONCLUSIONS Significant increases in the temperature of the pulpal cavity (up to 42.5 °C) may occur during bonding brackets according to the manufacturer's recommendation with an LED light curing unit with in vitro nonpulpal circulation approaches. Therefore it could be reasonable to critically question the recommendation of the manufacturer.
Collapse
|
15
|
Oliveira TA, Anágua-Bravo E, Aoki IV, Scaramucci T, Sobral MAP. Chemical and mechanical resistance of novel experimental hybrid coatings on dentin permeability. Microsc Res Tech 2020; 84:163-170. [PMID: 32869428 DOI: 10.1002/jemt.23574] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 07/22/2020] [Accepted: 07/31/2020] [Indexed: 11/06/2022]
Abstract
This study aimed to evaluate the capacity of novel experimental hybrid coatings (HC) to reduce dentin permeability and to verify their resistance to erosive and abrasive challenges. Dentin disc specimens (1 mm thick) were treated with 0.5 M EDTA solution and randomly allocated into three experimental groups (n = 10): Control (Saliva); Concentrated Hybrid Coating (TEOS/GPTMS/Y-APS); and Diluted Hybrid Coating (1:3 ratio with distilled water). Dentin permeability was assessed by hydraulic conductance in the following experimental time periods: post-EDTA, post treatment, post erosion (5 min in 0.05 M citric acid solution, pH = 3.8), and post abrasion (toothbrushing for 3,900 cycles). Dentin permeability percent was calculated with respect the values of post-EDTA for each experimental time. The morphology of the surface of extra dentin specimens was examined by scanning electron microscopy (SEM) in the same time periods (n = 3). Permeability data were analyzed by two-way repeated measures ANOVA and Tukey tests (p < .05). Both HC presented significantly lower dentin permeability than control post treatment and post erosion (p < .05), without difference between them (p > .05). Post abrasion, there were no significant difference among groups (p > .05). Post treatment and post erosion, the HC seemed to flow into the tubules, occluding them, while the tubules in control remained opened. Post abrasion, the tubules appear to be occluded in all groups. In conclusion, the experimental hybrid coatings were capable of reducing dentin permeability after treatment. They were also able to resist to erosive and abrasive challenges, with the advantage of forming thinner and colorless films that can be potentially used to treat dentin hypersensitivity.
Collapse
Affiliation(s)
- Tatiane Alexandre Oliveira
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil
| | - Ernesto Anágua-Bravo
- Department of Chemical Engineering, Polytechnic School, University of São Paulo, São Paulo, SP, Brazil
| | - Idalina Vieira Aoki
- Department of Chemical Engineering, Polytechnic School, University of São Paulo, São Paulo, SP, Brazil
| | - Taís Scaramucci
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil
| | - Maria Angela Pita Sobral
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil
| |
Collapse
|
16
|
Erhardt MCG, Goulart M, Jacques RC, Rodrigues JA, Pfeifer CS. Effect of different composite modulation protocols on the conversion and polymerization stress profile of bulk-filled resin restorations. Dent Mater 2020; 36:829-837. [PMID: 32446504 PMCID: PMC7305981 DOI: 10.1016/j.dental.2020.03.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 03/15/2020] [Accepted: 03/16/2020] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The aim of this in vitro study was to test the effect of different composite modulation protocols (pre-heating, light-curing time and oligomer addition) for bulk filling techniques on resin polymerization stress, intra-pulpal temperature change and degree of conversion. METHODS Class I cavities (4mm depth×5mm diameter) were prepared in 48 extracted third molars and divided in 6 groups. Restorations were completed with a single increment, according to the following groups: (1) Filtek Z250XT (room temperature - activated for 20s); (2) Filtek Z250XT (at room temperature - activated for 40s); (3) Filtek Z250XT (pre-heated at 68°C - activated for 20s); (4) Filtek Z250XT (pre-heated at 68°C - activated for 40s); (5) Filtek BulkFill (at room temperature - activated for 20s); (6) Filtek Z250XT (modified by the addition of a thio-urethane oligomer at room temperature - activated for 40s). Acoustic emission test was used as a real-time polymerization stress (PS) assessment. The intra-pulpal temperature change was recorded with a thermocouple and bottom/top degree of conversion (DC) measured by Raman spectroscopy. Data were analyzed with one-way ANOVA/Tukey's test (α=5%). RESULTS Pre-heating the resin composite did not influence the intra-pulpal temperature (p=0.077). The thio-urethane-containing composite exhibited significantly less PS, due to a lower number of acoustic events. Groups with pre-heated composites did not result in significantly different PS. Filtek BulkFill and the thio-urethane experimental composite presented significantly higher DC. SIGNIFICANCE Resin composite pre-heating was not able to reduce polymerization stress in direct restorations. However, thio-urethane addition to a resin composite could reduce the polymerization stress while improving the DC.
Collapse
Affiliation(s)
- M C G Erhardt
- Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | - M Goulart
- Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - R C Jacques
- Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - J A Rodrigues
- Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - C S Pfeifer
- Oregon Health and Science University, Portland, OR, USA
| |
Collapse
|
17
|
Palagummi SV, Hong T, Wang Z, Moon CK, Chiang MYM. Resin viscosity determines the condition for a valid exposure reciprocity law in dental composites. Dent Mater 2019; 36:310-319. [PMID: 31866065 DOI: 10.1016/j.dental.2019.12.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 12/04/2019] [Accepted: 12/04/2019] [Indexed: 10/25/2022]
Abstract
OBJECTIVE To provide conditions for the validity of the exposure reciprocity law as it pertains to the photopolymerization of dimethacrylate-based dental composites. METHODS Composites made from different mass ratios of resin blends (Bis-GMA/TEGDMA and UDMA/TEGDMA) and silanized micro-sized glass fillers were used. All the composites used camphorquinone and ethyl 4-dimethylaminobenzoate as the photo initiator system. A cantilever beam-based instrument (NIST SRI 6005) coupled with NIR spectroscopy and a microprobe thermocouple was used to simultaneously measure the degree of conversion (DC), the polymerization stress (PS) due to the shrinkage, and the temperature change (TC) in real time during the photocuring process. The instrument has an integrated LED light curing unit providing irradiances ranging from 0.01W/cm2 to 4W/cm2 at a peak wavelength of 460nm (blue light). Vickers hardness of the composites was also measured. RESULTS For every dental composite there exists a minimum radiant exposure required for an adequate polymerization (i.e., insignificant increase in polymerization with any further increase in the radiant exposure). This minimum predominantly depends on the resin viscosity of composite and can be predicted using an empirical equation established based on the test results. If the radiant exposure is above this minimum, the exposure reciprocity law is valid with respect to DC for high-fill composites (filler contents >50% by mass) while invalid for low-fill composites (that are clinically irrelevant). SIGNIFICANCE The study promotes better understanding on the applicability of the exposure reciprocity law for dental composites. It also provides a guidance for altering the radiant exposure, with the clinically available curing light unit, needed to adequately cure the dental composite in question.
Collapse
Affiliation(s)
- Sri Vikram Palagummi
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, United States
| | - Taeseung Hong
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, United States; Department of Materials Science and Engineering, Pukyong National University, Busan, Republic of Korea
| | - Zhengzhi Wang
- Department of Engineering Mechanics, School of Civil Engineering, Wuhan University, Wuhan, Hubei, China
| | - Chang Kwon Moon
- Department of Materials Science and Engineering, Pukyong National University, Busan, Republic of Korea
| | - Martin Y M Chiang
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, MD, United States.
| |
Collapse
|
18
|
Paolucci T, Pezzi L, Centra MA, Porreca A, Barbato C, Bellomo RG, Saggini R. Effects of capacitive and resistive electric transfer therapy in patients with painful shoulder impingement syndrome: a comparative study. J Int Med Res 2019; 48:300060519883090. [PMID: 31680597 PMCID: PMC7783264 DOI: 10.1177/0300060519883090] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Objective Capacitive and resistive electric transfer therapy (CARE) reduces pain and
improves quality of life for many orthopaedic degenerative and inflammatory
disorders. The research aim was to determine the effects of CARE on painful
shoulder. The outcomes were pain reduction and recovery of shoulder
function. Methods A retrospective, observational case-control study was conducted. Participants
were 46 patients (22 in the CARE group and 24 in the SHAM group). Clinical
data, pain (visual analogic scale, VAS) and functional scale scores
(Disabilities of the Arm, Shoulder and Hand scale, and Constant–Murley
Scale) were measured at baseline T0 (before treatment), T1 (after treatment)
and follow-up T2 (2 months after the end of the treatment). Results VAS scores in the CARE group improved from 7.23 ± 1.11 at baseline to
2.68 ± 0.99 at follow-up. The SHAM group did not experience any improvement.
Similarly, functional scale scores improved in the CARE group compared with
the SHAM group. Conclusion Considering the small number of sessions needed, low cost and long-term
benefits, CARE could be a useful therapeutic option for the conservative
management of shoulder pain to restore pain-free and powerful movement to
the shoulder joint.
Collapse
Affiliation(s)
- T Paolucci
- University G. d'Annunzio Chieti, Department of Medical and Oral Sciences and Biotechnologies, Chieti-Pescara, Italy
| | - L Pezzi
- University G. d'Annunzio Chieti, Department of Medical and Oral Sciences and Biotechnologies, Chieti-Pescara, Italy
| | - M A Centra
- University G. d'Annunzio Chieti, Department of Medical and Oral Sciences and Biotechnologies, Chieti-Pescara, Italy
| | - A Porreca
- Department of Economics, 'Gabriele d'Annunzio' University, Chieti-Pescara, Italy
| | - C Barbato
- University of Study of Urbino Carlo Bo, Department of Biomolecular Sciences, Urbino, Italy
| | - R G Bellomo
- University of Study of Urbino Carlo Bo, Department of Biomolecular Sciences, Urbino, Italy
| | - R Saggini
- University G. d'Annunzio Chieti, Department of Medical and Oral Sciences and Biotechnologies, Chieti-Pescara, Italy
| |
Collapse
|
19
|
André CB, Nima G, Sebold M, Giannini M, Price RB. Stability of the Light Output, Oral Cavity Tip Accessibility in Posterior Region and Emission Spectrum of Light-Curing Units. Oper Dent 2018; 43:398-407. [DOI: 10.2341/17-033-l] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARYObjectives: This study evaluated the light output from six light-emitting diode dental curing lights after 25 consecutive light exposures without recharging the battery, tip accessibility in the posterior region, and light beam spread from light-curing units.Methods: Irradiance, spectral peak, and radiant exposure were measured with the battery fully charged (Bluephase Style, ESPE Cordless, Elipar S10, Demi Ultra, Valo Cordless, and Radii-Cal) and monitored for 25 light exposures (each lasting 10 seconds). The tip diameter was measured to identify the beam size and the ability of the six light-curing units to irradiate all areas of the lower second molar in the standard output setting.Results: Four curing lights delivered a single peak wavelength from 454 to 462 nm, and two (Bluephase Style and Valo Cordless) delivered multiple emission peaks (at 410 and 458 nm and 400, 450, and 460 nm, respectively). The irradiance and radiant exposure always decreased after 25 exposures by 2% to 8%, depending on the light unit; however, only ESPE Cordless, Valo Cordless, and Radii-Cal presented a statistical difference between the first and the last exposure. The tip diameter ranged from 6.77 mm to 9.40 mm. The Radii-Cal delivered the lowest radiant exposure and irradiance. This light was also unable to access all the teeth with the tip parallel to the occlusal surface of the tooth.Conclusion: Not all of the blue-emitting lights deliver the same emission spectra, and some curing lights delivered a lower irradiance (as much as 8% lower) after the 25th exposure.
Collapse
Affiliation(s)
- CB André
- Carolina Bosso André, DDS, MS, PhD, State University of Campinas, Piracicaba Dental School, Restorative Dentistry, Piracicaba, Brazil
| | - G Nima
- Gabriel Nima, DDS, MS, PhD student, State University of Campinas, Piracicaba Dental School, Dental Materials, Piracicaba, Brazil
| | - M Sebold
- Maicon Sebold, DDS, MS, PhD student, State University of Campinas, Piracicaba Dental School, Restorative Dentistry, Piracicaba, Brazil
| | - M Giannini
- Marcelo Giannini, DDS, MS, PhD, associate professor, Piracicaba Dental School, University of Campinas, Department of Restorative Dentistry, Piracicaba, Brazil
| | - RB Price
- Richard B. Price, BDS, DDS, MS, PhD, FDS RCS (Edin), FRCD(C), Dalhousie University, Dental Clinical Sciences, Halifax, Nova Scotia, Canada
| |
Collapse
|
20
|
Abstract
The ability to light cure resins 'on demand' in the mouth has revolutionized dentistry. However, there is a widespread lack of understanding of what is required for successful light curing in the mouth. Most instructions simply tell the user to 'light cure for xx seconds' without describing any of the nuances of how to successfully light cure a resin. This article provides a brief description of light curing. At the end, some recommendations are made to help when purchasing a curing light and how to improve the use of the curing light.
Collapse
Affiliation(s)
- Richard B T Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia B3H 4R2, Canada.
| |
Collapse
|
21
|
Garduño-Ramón MA, Vega-Mancilla SG, Morales-Henández LA, Osornio-Rios RA. Supportive Noninvasive Tool for the Diagnosis of Breast Cancer Using a Thermographic Camera as Sensor. SENSORS (BASEL, SWITZERLAND) 2017; 17:E497. [PMID: 28273793 PMCID: PMC5375783 DOI: 10.3390/s17030497] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/15/2017] [Accepted: 02/22/2017] [Indexed: 11/17/2022]
Abstract
Breast cancer is the leading disease in incidence and mortality among women in developing countries. The opportune diagnosis of this disease strengthens the survival index. Mammography application is limited by age and periodicity. Temperature is a physical magnitude that can be measured by using multiple sensing techniques. IR (infrared) thermography using commercial cameras is gaining relevance in industrial and medical applications because it is a non-invasive and non-intrusive technology. Asymmetrical temperature in certain human body zones is associated with cancer. In this paper, an IR thermographic sensor is applied for breast cancer detection. This work includes an automatic breast segmentation methodology, to spot the hottest regions in thermograms using the morphological watershed operator to help the experts locate the tumor. A protocol for thermogram acquisition considering the required time to achieve a thermal stabilization is also proposed. Breast thermograms are evaluated as thermal matrices, instead of gray scale or false color images, increasing the certainty of the provided diagnosis. The proposed tool was validated using the Database for Mastology Research and tested in a voluntary group of 454 women of different ages and cancer stages with good results, leading to the possibility of being used as a supportive tool to detect breast cancer and angiogenesis cases.
Collapse
Affiliation(s)
- Marco Antonio Garduño-Ramón
- Facultad de Ingeniería, CA Mecatrónica, Universidad Autónoma de Querétaro, Campus San Juan del Río, Av. Río Moctezuma 249, Col. San Cayetano, C.P. 76807, San Juan del Río, Querétaro, Mexico.
| | - Sofia Giovanna Vega-Mancilla
- Facultad de Ingeniería, CA Mecatrónica, Universidad Autónoma de Querétaro, Campus San Juan del Río, Av. Río Moctezuma 249, Col. San Cayetano, C.P. 76807, San Juan del Río, Querétaro, Mexico.
| | - Luis Alberto Morales-Henández
- Facultad de Ingeniería, CA Mecatrónica, Universidad Autónoma de Querétaro, Campus San Juan del Río, Av. Río Moctezuma 249, Col. San Cayetano, C.P. 76807, San Juan del Río, Querétaro, Mexico.
| | - Roque Alfredo Osornio-Rios
- Facultad de Ingeniería, CA Mecatrónica, Universidad Autónoma de Querétaro, Campus San Juan del Río, Av. Río Moctezuma 249, Col. San Cayetano, C.P. 76807, San Juan del Río, Querétaro, Mexico.
| |
Collapse
|
22
|
Assessment of Heat Hazard during the Polymerization of Selected Light-Sensitive Dental Materials. BIOMED RESEARCH INTERNATIONAL 2016; 2016:4158376. [PMID: 27840825 PMCID: PMC5093250 DOI: 10.1155/2016/4158376] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Revised: 09/21/2016] [Accepted: 09/21/2016] [Indexed: 11/17/2022]
Abstract
Introduction. Polymerization of light-cured dental materials used for restoration of hard tooth tissue may lead to an increase in temperature that may have negative consequence for pulp vitality. Aim. The aim of this study was to determine maximum temperatures reached during the polymerization of selected dental materials, as well as the time that is needed for samples of sizes similar to those used in clinical practice to reach these temperatures. Materials and Methods. The study involved four composite restorative materials, one lining material and a dentine bonding agent. The polymerization was conducted with the use of a diode light-curing unit. The measurements of the external surface temperature of the samples were carried out using the Thermovision®550 thermal camera. Results. The examined materials significantly differed in terms of the maximum temperatures values they reached, as well as the time required for reaching the temperatures. A statistically significant positive correlation of the maximum temperature and the sample weight was observed. Conclusions. In clinical practice, it is crucial to bear in mind the risk of thermal damage involved in the application of light-cured materials. It can be reduced by using thin increments of composite materials.
Collapse
|