Li D, Wang S, Lin H, Wang K, Guo Y, Yu L, Fang X. Effect of synovial fluid temperature on wear resistance of different polymer acetabular materials. J Biomater Appl 2023; 37:1736-1757. [PMID: 36927235 DOI: 10.1177/08853282231163678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
In order to investigate the effect of frictional heat on the wear resistance characteristics of polymeric acetabular materials, the tribological tests and wear numerical analysis of three common polymer acetabular materials were carried out under different synovial fluid temperatures. The study results show that XLPE and VE-XLPE exhibit superior wear resistance compared to UHMWPE in high-temperature, heavy load environments. The coefficient of friction of three materials gradually decreases as the temperature of the synovial fluid increases. The wear depth and wear volume of the three materials increased with the increase of the temperature of the synovial fluid, and the forms of wear at 46°C and 55°C were mainly adhesive wear and plastic deformation. The higher temperature of the synovial fluid accelerates the oxidative degradation of the material surface and generates oxidation functional groups, which leads to the breakage of C-C bonds in the surface molecular chains under the sliding shear effect, thus reducing the mechanical properties of the material. Specifically, the surface of the polymer material will soften at a higher ambient temperature, mainly due to the decrease of hardness, and then deteriorate in the friction property, and finally increase the wear rate. Ansys results showed that the volume wear of the three materials increased with the increase of synovial fluid temperature, and the trend could be approximately linear. Numerical calculations predict that VE-XLPE has the highest wear of 0.693 mm3 among the three materials at 37°C, followed by XLPE at 0.568 mm3 and UHMWPE with the lowest wear of 0.478 mm3. At higher synovial fluid temperatures (46°C, 55°C), VE-XLPE still has the largest wear volume among the three materials, while XLPE and UHMWPE have similar wear. The wear cloud pictures showed that the maximum wear volume occurred near the edge of the acetabulum.
Collapse
Affiliation(s)
- Dahan Li
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| | - Songquan Wang
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| | - Hao Lin
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| | - Kaijun Wang
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| | - Yongbo Guo
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| | - Lu Yu
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| | - Xingxing Fang
- Center for Tribology, School of Mechatronic Engineering, 12675Jiangsu Normal University, Xuzhou, Jiangsu Province, China
| |
Collapse
|
2
|
Baghdadi J, Alkhateeb S, Roth A, Jäger M, Alkhateeb S, Landgraeber S, Serong S, Haversath M, vonWasen A, Windhagen H, Flörkemeier T, Budde S, Kubilay J, Noll Y, Delank KS, Baghdadi J, Willburger R, Dücker M, Wilke A, Hütter F, Jäger M. Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up. Arch Orthop Trauma Surg 2023; 143:1679-1688. [PMID: 35397656 PMCID: PMC9957849 DOI: 10.1007/s00402-022-04424-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 03/10/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Aseptic loosening remains a challenging problem after total hip arthroplasty. Accurate cup placement and supplementation of antioxidants in acetabular liners might reduce material failure rates. The aim of this study is to assess the effect of the cup position on the wear behaviour of UHMWPE-XE and UHMWPE-X liners in vivo using virtual radiographs. METHODS We conducted a prospective, randomized, controlled, multicenter trial. Clinical data of 372 probands were analyzed. Anteroposterior pelvic X-rays of 324 patients immediately postoperatively and after 1 and 5 years were evaluated by the RayMatch® analysis software regarding cup position and wear behaviour. RESULTS Mean cup anteversion was 20.3° (± 7.4) and inclination was 41.9° (± 7.0) postoperatively. 62.3% of all patients had an anteversion and inclination within the Lewinnek safe zone. Anterior and anterolateral approaches led to significantly higher cup anteversion compared to lateral approaches (27.3° ± 5.5; 20.9° ± 7.2; 17.5° ± 6.6; p < 0.001 and p = 0.001, respectively). Mean anteversion increased to 24.6° (± 8.0) after 1 year (p < 0.001). Only one revision occurred because of implant dislocation. Wear rates from UHMWPE-X and UHMWPE-XE did not differ significantly. Anteversion angles ≥ 25° correlated to increased polyethylene wear (23.7 µm/year ± 12.8 vs. 31.1 µm/year ± 22.8, p = 0.012) and this was amplified when inclination angles were ≥ 50° (23.6 µm/year ± 12.8 vs. 38.0 µm/year ± 22.7, p = 0.062). CONCLUSION Anterior approaches lead to the highest inaccuracy of cup placement, but cup positioning outside the Lewinnek safe zone does not necessarily cause higher dislocation rates. Moreover, mean anteversion increased by approximately four degrees within the first year after operation, which is expected to be functional due to a regularization of pelvic tilt after intervention. Mid-term wear rates of UHMWPE-X and UHMWPE-XE liners are comparable, but steep cup positions lead to significantly increased polyethylene wear. In summary, a re-evaluation of target zones for intraoperative cup positioning might be considered. In the long-term reduced oxidative embrittlement could lead to superior wear behaviour of vitamin E-blended liners.
Collapse
Affiliation(s)
- Josef Baghdadi
- Department of Orthopedics, Trauma, and Reconstructive Surgery, University Hospital Halle (Saale), Halle (Saale), Germany.
| | - Shareef Alkhateeb
- Department of Orthopedics, Trauma and Reconstructive Surgery, Marienhospital Mülheim an Der Ruhr, Chair of Orthopedics and Trauma Surgery, University of Duisburg–Essen, Essen, Germany
| | | | | | - Marcus Jäger
- Department of Orthopedics, Trauma and Reconstructive Surgery, Marienhospital Mülheim an Der Ruhr, Chair of Orthopedics and Trauma Surgery, University of Duisburg–Essen, Essen, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Dammer RH, Zietz C, Bader R. A Comparison of Wear Patterns on Retrieved and Simulator-Tested Total Knee Replacements. J Funct Biomater 2022; 13:256. [PMID: 36412896 PMCID: PMC9680524 DOI: 10.3390/jfb13040256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/10/2022] [Accepted: 11/16/2022] [Indexed: 11/22/2022] Open
Abstract
Aseptic implant loosening is the most common reason for revision surgery after total knee replacement. This is associated with adverse biological reactions to wear debris from the articulating implant components. To predict the amount of wear debris generated in situ, standard wear testing of total knee replacement (TKR) is carried out before its clinical use. However, wear data reported on retrievals of total knee replacement (TKR) revealed significant discrepancies compared with standard wear simulator studies. Therefore, the aim of the present study was to compare the wear patterns on identical posterior-cruciate-retaining TKR designs by analyzing retrieved and experimentally tested implants. The identification and classification of wear patterns were performed using 21 retrieved ultra-high-molecular-weight-polyethylene (UHMW-PE) inserts and four sets of inserts of identical design and material tested in a knee wear simulator. These four sets had undergone different worst-case conditions and a standard test in a wear simulator according to ISO 14243-1. Macroscopic and microscopic examinations of the polyethylene inserts were performed, including the determination of seven modes of wear that correspond to specific wear patterns, the calculation of wear areas, and the classification of the damage over the whole articulating area. Retrieved and standard wear simulator-tested UHMW-PE inserts showed significant differences in wear area and patterns. The total wear areas and the damage score were significantly larger on the retrievals (52.3% versus 23.9%, 32.7 versus 22.7). Furthermore, the range of wear patterns found on the retrievals was not reproducible in the simulator-tested inserts. However, good correspondence was found with the simulator-tested polyethylene inserts under worst-case conditions (third body wear), i.e., deep wear areas could be replicated according to the in vivo situation compared with other wear test scenarios. Based on the findings presented here, standard simulator testing can be used to directly compare different TKR designs but is limited in the prediction of their in situ wear. Preclinical wear testing may be adjusted by worst-case conditions to improve the prediction of in situ performance of total knee implants in the future.
Collapse
Affiliation(s)
- Rebecca H. Dammer
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057 Rostock, Germany
| | | | | |
Collapse
|
4
|
Characterization of In Vivo Damage on Retrieved Total Shoulder Glenoid Liners. LUBRICANTS 2022. [DOI: 10.3390/lubricants10080166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
An attempt was made to retrieve glenoid liners from revision surgery to undertake a retrospective study to measure the resulting in vivo damage. Since the glenoid liners are circumferential, the curvature changes at every point in the component, an “assisting arm” was designed to hold the liner firmly, thus allowing accurate microscopic measurements. We characterized the damage in terms of pitting, embedded debris, complete fracture, abrasion, deformation, delamination, burnishing, grooving, and scratching that took place mutually exclusively. This study of 26 liners showed embedded debris was the most underrated damage mode found on the liners, followed by pitting and abrasion, representing 65.2% and 52.2% of the liners, respectively. The prevalence of pitting in over half the samples examined is indicative of free-radical oxidation, resulting in a decrease in physical strength from morphological changes in the microstructure. These may initiate from different pathways, however, they may interact with other processes in which other damage initiates and grows, resulting in higher damage causing premature failure due to wear. A probabilistic approach was developed to generate survival time for these liners and may provide a statistical removal time of the glenoid liners in the future.
Collapse
|
5
|
Nicholson AD, Mathew JI, Koch CN, Kontaxis A, Wright T, Taylor SA, Blaine TA, Dines JS, Dines DM, Fu MC, Warren RF, Gulotta LV. Backside polyethylene wear in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2022; 31:545-552. [PMID: 34619352 DOI: 10.1016/j.jse.2021.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/01/2021] [Accepted: 09/06/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Aseptic loosening from implant-associated osteolysis in reverse shoulder arthroplasty (RSA) may contribute to premature implant failure. Although articular side polyethylene (PE) damage has been well documented in the literature, no studies to date have investigated backside wear in RSA. The aims of this investigation were to (1) document and compare the damage between the backside and articular surface in explanted RSA components, (2) assess whether certain quadrants have a greater propensity for damage, and (3) report the most common mode(s) of backside PE damage. METHODS Twenty-one RSA humeral liners retrieved during revision procedures between 2005 and 2014 were included for analysis. The mean time between implantation and extraction was 16 months (10 days-88 months). Diagnoses at the time of revision included dislocation (10), infection (4), mechanical failure (3), loosening (2), and unknown (2). Liners were examined under light microscopy (×10-30 magnification) and damage on the articular and backside of the liner surface was graded using the modified Hood score. The location and damage modality were compared between the articular side and backside of the implant. RESULTS Damage was noted on the articular surfaces of all 21 liners and on the backside surface of 20 liners. The total damage in all the quadrants was higher on the articular surface than on the backside of the component, with a mean difference in total quadrant damage scores of 11.74 ± 3.53 (P < .001). There was no difference in damage among the quadrants on the backside (P = .44) or the articular surface (P = .08). The articular side exhibited greater scratching, abrasion, and surface deformation than the backside (P < .001). CONCLUSIONS This short-term retrieval study demonstrated that backside PE damage occurs on the humeral component of RSA implants. There was greater damage to the articular side of the liner but wear to the backside was present in almost all liners. The clinical importance of backside wear in RSA and its overall contribution to PE particulate disease and osteolysis needs further investigation.
Collapse
|
6
|
Jaeger S, Uhler M, Schroeder S, Beckmann NA, Braun S. Comparison of Different Locking Mechanisms in Total Hip Arthroplasty: Relative Motion between Cup and Inlay. MATERIALS 2020; 13:ma13061392. [PMID: 32204382 PMCID: PMC7142960 DOI: 10.3390/ma13061392] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 03/11/2020] [Accepted: 03/16/2020] [Indexed: 01/03/2023]
Abstract
The resulting inflammatory reaction to polyethylene (PE) wear debris, which may result in osteolysis, is still considered to be a main reason for aseptic loosening. In addition to the primary wear in hip joint replacements caused by head-insert articulation, relative motions between the PE liner and the metal cup may cause additional wear. In order to limit this motion, various locking mechanisms were used. We investigated three different locking mechanisms (Aesculap, DePuy, and Zimmer Biomet) to address the resulting relative motion between the acetabular cup and PE liner and the maximum disassembly force. A standardized setting with increasing load levels was used in combination with optically based three-dimensional measurements. In addition the maximum disassembly forces were evaluated according to the ASTM F1820-13 standard. Our data showed significant differences between the groups, with a maximum relative motion at the maximum load level (3.5 kN) of 86.5 ± 32.7 µm. The maximum axial disassembly force was 473.8 ± 94.6 N. The in vitro study showed that various locking mechanisms may influence cup-inlay stability.
Collapse
Affiliation(s)
- Sebastian Jaeger
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg University, 69118 Heidelberg, Germany; (S.S.); (S.B.)
- Correspondence: (S.J.); (M.U.)
| | - Maximilian Uhler
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg University, 69118 Heidelberg, Germany; (S.S.); (S.B.)
- Correspondence: (S.J.); (M.U.)
| | - Stefan Schroeder
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg University, 69118 Heidelberg, Germany; (S.S.); (S.B.)
| | - Nicholas A. Beckmann
- Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg University, 69118 Heidelberg, Germany;
- Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, 3010 Bern, Switzerland
| | - Steffen Braun
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Heidelberg University, 69118 Heidelberg, Germany; (S.S.); (S.B.)
| |
Collapse
|
7
|
|
8
|
Puente Reyna AL, Holderied M, Jäger M, Schilling C, Grupp TM. ARTICULATION AND BACKSIDE WEAR ANALYSIS AFTER LONG-TERM IN VITRO WEAR SIMULATION OF VITAMIN E STABILIZED POLYETHYLENE ACETABULAR LINERS WITH A PRESS-FIT LOCKING MECHANISM. ACTA ACUST UNITED AC 2018. [DOI: 10.21823/2311-2905-2018-24-2-29-40] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A previous retrieval study analyzed the backside wear of short-term implanted liners against in vitro tested liners of similar life in service and showed comparable results among both groups, with no significant backside wear due to micro-motion.The purpose — to obtain a picture of the overall wear (articulation and backside surfaces) of 0.1% vitamin e blended polyethylene liners, with a locking mechanism based on a press-fit cone in combination with a rough titanium conical inner surface in the fixation area, under a 20 million cycles hip wear simulation.Materials and Methods. A semi-quantitative method was used in order to assess the damage on the backside of the liners and a 3d measuring machine to assess the creep and wear at the articulation surface.Results. The total average backside wear score was 22.00±2.59 from a maximum total score of 147 after 5 million cycles (mc), increased to 31.92±5.57 after 10 mc, but showed no further increment after 15 and 20 mc. The reference liners (subjected only to axial load) showed similar wear scores and modes as the liners under wear simulation (axial load and movement). Small scratches produced during insertion and removal were clearly seen at the rim (fixation) area and no considerable abrasion was observed. The machining marks on the convex surface were always visible. Regarding the articulation surface, a steady state wear rate of 7 µm/year was measured.Conlusion. These results determined that most of the backside wear produced on the liners occurred during their insertion and removal rather than during their life in service. Moreover, the wear at the articulation surface was similar to that seen in vivo at short- and mid-term on highly cross-linked polyethylene liners with and without vitamin e content.
Collapse
|
9
|
Moon JK, Kim Y, Hwang KT, Yang JH, Oh YH, Kim YH. Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17- to 23-Year Follow-Up Study of a Previous Report. J Arthroplasty 2018; 33:2165-2172. [PMID: 29656971 DOI: 10.1016/j.arth.2018.02.089] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Revised: 02/03/2018] [Accepted: 02/23/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography. METHODS A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated. RESULTS The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%). CONCLUSION MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.
Collapse
Affiliation(s)
- Jun-Ki Moon
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - Yeesuk Kim
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - Kyu-Tae Hwang
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - Jae-Hyuk Yang
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - Young-Ha Oh
- Department of Pathology, Hanyang University Guri Hospital, Guri, South Korea
| | - Young-Ho Kim
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| |
Collapse
|