Quaresima S, Balla A, Palmieri L, Seitaj A, Fingerhut A, Ursi P, Paganini AM. Routine near infra-red indocyanine green fluorescent cholangiography versus intraoperative cholangiography during laparoscopic cholecystectomy: a case-matched comparison.
Surg Endosc 2019;
34:1959-1967. [PMID:
31309307 DOI:
10.1007/s00464-019-06970-0]
[Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 07/01/2019] [Indexed: 12/18/2022]
Abstract
BACKGROUND
The aim is to evaluate safety and efficacy of near infra-red (NIR) indocyanine green (ICG) fluorescence structural imaging during laparoscopic cholecystectomy (LC) (Group A) and to compare perioperative data, including operative time, with a series of patients who underwent LC with routine traditional intraoperative cholangiography (IOC) (Group B).
METHODS
Forty-four patients with acute or chronic cholecystitis underwent NIR-ICG fluorescent cholangiography during LC. ICG was administered intravenously at different time intervals or by direct gallbladder injection during surgery. Fluorescence intensity and anatomy identification were scored according to a visual analogue scale between 1 (least accurate) and 5 (most accurate). Group B patients (n = 44) were chosen from a prospectively maintained database of patients who underwent LC with routine IOC, matched for age, sex, body mass index, and diagnosis with group A patients.
RESULTS
No adverse reactions were recorded. In group A, mean time between intravenous administration of ICG and surgery was 10.7 ± 8.2 (range 2-52) h. Administered doses ranged from 3.5 to 13.5 mg. Fluorescence was present in all cases, scoring ≥ 3 in 41 patients. Mean operative time was 86.9 ± 36.9 (30-180) min in group A and 117.9 ± 43.4 (40-220) min in group B (p = 0.0006). No conversion to open surgery nor bile duct injuries were observed in either group.
CONCLUSIONS
LC with NIR-ICG fluorescent cholangiography is safe and effective for early recognition of anatomical landmarks, reducing operative time as compared to LC with IOC, even when residents were the main operator. NIR-ICG fluorescent cholangiography was effective in patients with acute cholecystitis and in the obese. Data collection into large registries on the results of NIR-ICG fluorescent cholangiography during LC should be encouraged to establish whether this technique might set a new safety standard for LC.
Collapse