1
|
Fu G, Jiang R, Qian C, Liu Z, Kong J, Gong M, Wang T, He X. The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease. Ann Vasc Surg 2024; 100:1-7. [PMID: 37918661 DOI: 10.1016/j.avsg.2023.09.071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 09/03/2023] [Accepted: 09/06/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND Comparing the accuracy and reliability of ankle-brachial index (ABI) measured by an oscillometric device with the Doppler method in peripheral arterial disease (PAD). METHODS 122 patients admitted to the department of interventional radiology with PAD were studied. ABI was measured with the 2 methods in random order. After excluding the inconclusive results, Doppler ABIs were compared with the oscillometric ABIs in each limb, the reliability was evaluated by intraclass correlation coefficient (ICC), and the accuracy and consistency were assessed by receiver operating characteristic curves and Bland-Altman method. RESULTS In 122 patients (244 legs), 27 legs got inconclusive oscillometric results, 4 legs got inconclusive oscillometric and inconclusive dorsalis pedis artery Doppler results, 2 legs had oscillometric cuff pressure intolerance. Using Doppler ABI <0.9 as a diagnostic threshold, compared with the high Doppler ABI, oscillometric method had a sensitivity of 57.81%, a specificity of 95.18%, the ICC was 0.626 (95% confidence interval [CI]: 0.536-0.701), Bland-Altman method showed 11/211 (5.21%) difference points outside the 95% limits of agreement. Compared with the low Doppler ABI, oscillometric method had a sensitivity of 50.66%, a specificity of 98.31%, the ICC was 0.541(95% CI: 0.483-0.630), Bland-Altman method showed 11/211 (5.21%) difference points outside the 95% limits of agreement. Using 1.00 as the diagnostic threshold and considering error oscillometric results as abnormal ABIs, the sensitivity improved to 88.05% with high Doppler ABI and 81.42% with the low. CONCLUSIONS The accuracy and reliability of oscillometric ABI in patients with PAD is unsatisfied, which makes it not suitable as an alternative method in clinic disease assessment. Using 1.0 as the ABI oscillometric threshold for PAD diagnosis can improve the diagnostic value.
Collapse
Affiliation(s)
- Guanqi Fu
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Rui Jiang
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Cheng Qian
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Zhengli Liu
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Jie Kong
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Maofeng Gong
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Tao Wang
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Xu He
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China.
| |
Collapse
|
2
|
Poradzka AA, Czupryniak L. The use of the artificial neural network for three-month prognosis in diabetic foot syndrome. J Diabetes Complications 2023; 37:108392. [PMID: 36623424 DOI: 10.1016/j.jdiacomp.2022.108392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 12/22/2022] [Accepted: 12/27/2022] [Indexed: 01/03/2023]
Affiliation(s)
- Anna A Poradzka
- Department of Diabetology and Internal Medicine, Medical University of Warsaw, Banacha 1a, 02-097 Warsaw, Poland.
| | - Leszek Czupryniak
- Department of Diabetology and Internal Medicine, Medical University of Warsaw, Banacha 1a, 02-097 Warsaw, Poland
| |
Collapse
|
3
|
Burhan A, Khusein NBA, Sebayang SM. Effectiveness of negative pressure wound therapy on chronic wound healing: A systematic review and meta-analysis. BELITUNG NURSING JOURNAL 2022; 8:470-480. [PMID: 37554236 PMCID: PMC10405659 DOI: 10.33546/bnj.2220] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/26/2022] [Accepted: 11/13/2022] [Indexed: 08/10/2023] Open
Abstract
BACKGROUND Negative Pressure Wound Therapy (NPWT) is considered an effective treatment in facilitating the healing of chronic wounds. However, its effect remains inconsistent, which allows for further investigation. OBJECTIVE This study aimed to assess the effectiveness of the NPWT program in improving the management of chronic wound healing. DESIGN Systematic review and meta-analysis was used. DATA SOURCES The search strategy ranged from 2016 to 2021 in PubMed, CINAHL, ProQuest, and ScienceDirect. REVIEW METHODS Risk of bias was done based on the Risk of Bias 2.0 guideline using RevMan 5.4.1, and meta-analysis was done using Jeffreys's Amazing Statistics Program (JASP) software version 0.16.3. Critical appraisal of the included articles was done according to Joanna Briggs Institute's (JBI) appraisal checklist. RESULTS A total of 15 articles were included, with 3,599 patients with chronic wounds. There was no publication bias in this study seen from the results of the Egger's test value of 0.447 (p >0.05), symmetrical funnel plot, and fail-safe N of 137. However, heterogeneity among studies was present, with I2 value of 66.7%, Q = 41.663 (p <0.001); thus, Random Effect (RE) model was used. The RE model showed a significant positive effect of the NPWT on chronic wound healing, with z = 3.014, p = 0.003, 95% CI 0.085 to 0.400. The observed effects include decreased rate of surgical site infection, controlled inflammation, edema, and exudate, as well as increased tissue with varying forest plot size, as demonstrated by the small effect size (ES = 0.24, 95% CI -0.26 to 0.79, p <0.05). CONCLUSION The analysis results show that the standard low pressure of 80-125 mmHg could improve microcirculation and accelerate the healing process of chronic wounds. Therefore, applying the NPWT program could be an alternative to nursing interventions. However, it should be carried out by competent wound nurses who carry out procedure steps, implement general patient care, and give tips on overcoming device problems and evaluation. PROSPERO REGISTRATION NUMBER CRD42022348457.
Collapse
Affiliation(s)
- Asmat Burhan
- School of Nursing, Health Faculty, Universitas Harapan Bangsa, Indonesia
| | | | | |
Collapse
|
4
|
Danieluk A, Chlabicz S. Automated Measurements of Ankle-Brachial Index: A Narrative Review. J Clin Med 2021; 10:jcm10215161. [PMID: 34768679 PMCID: PMC8585080 DOI: 10.3390/jcm10215161] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 10/30/2021] [Accepted: 11/01/2021] [Indexed: 12/24/2022] Open
Abstract
Peripheral artery disease (PAD) is an atherosclerotic disease that causes obstruction in lower limb arteries. It increases cardiovascular risk even in asymptomatic patients. Accurate diagnostic tools for identification of affected individuals are needed. Recently, there have been attempts to establish a reliable method of automated ankle-brachial index (ABI) identification. A search of PubMed database to identify studies assessing automatic ABI measurements in agreement with standard PAD diagnosis methods was conducted in December 2020. A total of 57 studies were analyzed in the review. The majority of analyzed studies found ABI measured by automatic oscillometric devices to be potentially feasible for use. Some note that, even though the Doppler and oscillometric methods are not fully interchangeable, the oscillometric devices could be used in screening. Significantly fewer publications are available on automatic plethysmographic devices. For photoplethysmography, most studies reported either good or moderate agreement with reference standards. For air plethysmography, poorer agreement with Doppler ABI is suggested. It is noted that pulse volume recording (PVR) function may improve the diagnostic accuracy of the devices.
Collapse
|
5
|
Ichihashi S, Desormais I, Hashimoto T, Magne J, Kichikawa K, Aboyans V. Accuracy and Reliability of the Ankle Brachial Index Measurement Using a Multicuff Oscillometric Device Versus the Doppler Method. Eur J Vasc Endovasc Surg 2020; 60:462-468. [PMID: 32763120 DOI: 10.1016/j.ejvs.2020.06.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 05/10/2020] [Accepted: 06/08/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE Ankle brachial index (ABI) is widely used for the diagnosis of lower extremity artery disease (LEAD). The purpose of this prospective study was to validate the diagnostic ability and reproducibility of a four cuff automated oscillometric device vs. the Doppler method. METHODS Patients with suspected LEAD or asymptomatic individuals at risk because of the presence two or more cardiovascular risk factors were enrolled. For each patient, Doppler and oscillometric ABI measurements were repeated by two observers to address intra- and interobserver reproducibility. RESULTS In total, 118 patients were evaluated. The prevalence of Doppler ABI (Dop-ABI) ≤ 0.90 was 45.8%. Taking the Dop-ABI as the reference, the sensitivity, specificity, accuracy, positive and negative predictive values of oscillometric ABI (Osc-ABI) during the first measurement by the first observer were 89.1%, 94.4%, 94.1%, 91.8%, and 92.4%, respectively. The concordance for diagnosing ABI ≤0.90 between methods was excellent (kappa coefficients ranging from 0.80 to 0.88 with different observers). Intra-observer reproducibility assessed by intraclass correlation coefficient (ICC) between methods were 0.94 for observer 1 and 0.96 for observer 2. The intra-observer reproducibility using the same method was also excellent (ICC 0.94, 95% confidence interval [CI] 0.91-0.95) for Dop-ABI and 0.95 (95% CI 0.93-0.97) for Osc-ABI). The ICC for interobserver reproducibility using the same method was 0.95 (95% CI 0.92-0.96) for Dop-ABI and 0.96 (95% CI 0.94-0.97) for Osc-ABI. CONCLUSION This study validates the excellent diagnostic performances of a four cuff oscillometric device specifically designed for screening for LEAD. The simple measurement method could therefore be advocated in primary care where fast, easy, and reliable methods are suitable.
Collapse
Affiliation(s)
- Shigeo Ichihashi
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Ileana Desormais
- Department of Thoracic and Vascular Surgery and Vascular Medicine, Dupuytren University Hospital, Limoges, France
| | - Tomoko Hashimoto
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan; Medical Product Development Department, Omron Healthcare Co., Ltd, Kyoto, Japan
| | - Julien Magne
- Department of Cardiology, Dupuytren University Hospital, Limoges, France
| | - Kimihiko Kichikawa
- Department of Radiology, Nara Medical University, Kashihara, Nara, Japan
| | - Victor Aboyans
- Department of Cardiology, Dupuytren University Hospital, Limoges, France.
| |
Collapse
|
6
|
Casey SL, Lanting SM, Chuter VH. The ankle brachial index in people with and without diabetes: intra-tester reliability. J Foot Ankle Res 2020; 13:21. [PMID: 32398142 PMCID: PMC7216386 DOI: 10.1186/s13047-020-00389-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Accepted: 04/29/2020] [Indexed: 11/26/2022] Open
Abstract
Background The ankle-brachial index (ABI) is widely used for determining the presence and severity of peripheral arterial disease (PAD), and current guidelines suggest it should be used to monitor possible progression in affected individuals. It is therefore important that the technique demonstrates adequate reliability for repeated measurements. Existing studies suggest that the ABI is reliable in the general population however, there is a lack of evidence for the reliability of the ABI in people with diabetes. The aim of this study was to investigate the intra-tester reliability of the ABI in people with and without diabetes. Methods Eighty-five participants (40 with and 45 without diabetes) underwent ankle and brachial systolic blood pressure measurements by a single clinician during two testing sessions. Intraclass correlation coefficients (ICC), their 95% limits of agreement, standard error of measurement and minimal detectable change were determined. Results Intra-tester reliability of the ABI was found to be good (ICC: 0.80), however sub-group analysis of participants with and without diabetes found that ABI was slightly less reliable in people with diabetes (ICC: 0.78) than in those without (ICC: 0.82). The relatively large limits of agreement (− 0.16 to 0.16), standard error of measurement (0.03 overall, 0.04 for the diabetes group), and minimal detectable change (0.08 overall, 0.11 for the diabetes group) suggest that a large change in ABI is required for it to demonstrate a true change rather than the result of measurement variability. The minimal detectable change for the ABI was 0.08 overall, and 0.11 for the diabetes group. Conclusions The ABI demonstrated good reliability in all groups analysed. However, the wide limits of agreement and considerable standard error of measurement obtained support the use of multiple methods of vascular assessment for ongoing monitoring of lower limb vascular status.
Collapse
Affiliation(s)
- Sarah Louise Casey
- School of Health Sciences, University of Newcastle, Ourimbah, Australia.
| | | | - Vivienne Helaine Chuter
- School of Health Sciences, University of Newcastle, Ourimbah, Australia.,Priority Research Centre for Physical Activity and Nutrition, University of Newcastle, Callaghan, Australia
| |
Collapse
|
7
|
Instruments of Choice for Assessment and Monitoring Diabetic Foot: A Systematic Review. J Clin Med 2020; 9:jcm9020602. [PMID: 32102313 PMCID: PMC7074122 DOI: 10.3390/jcm9020602] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 02/20/2020] [Accepted: 02/21/2020] [Indexed: 02/06/2023] Open
Abstract
Diabetic foot is the most frequent disorder among the chronic complications of diabetes, happening in 25% of patients. Objective clinical outcome measures are tests or clinical instruments that provide objective values for result measurement. The aim of this study was to carry out a systematic review of specific objective clinical outcome measures focused on the assessment and monitoring of diabetic foot disorders. The databases used were PubMed, CINAHL, Scopus, PEDro, Cochrane, SciELO and EMBASE. Search terms used were foot, ankle, diabet*, diabetic foot, assessment, tools, instruments, objective outcome measures, valid*, reliab*. Because of the current published evidence, diabetic neuropathy assessment via sudomotor analysis, cardiovascular autonomic neuropathy and peripheral vascular disease detection by non-invasive electronic devices, wound 3D dimensional measurement, hyperspectral imaging for ulcer prediction and the probe-to-bone test for osteomyelitis diagnosis were highlighted in this study.
Collapse
|
8
|
Khan SZ, Awn-Bin-Zafar, Waris N, Miyan Z, Ulhaque MS, Fawwad A. Comparison of ankle-brachial index (ABI) measured by an automated oscillometric apparatus with that by standard hand-held doppler in patients with Type-2 diabetes. Pak J Med Sci 2019; 35:1167-1172. [PMID: 31372162 PMCID: PMC6659060 DOI: 10.12669/pjms.35.4.30] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Objective: To compare the difference between an automated oscillometric ABI measurement as compared to standard hand-held doppler ABI in patients with Type-2 diabetes. Methods: This prospective study was conducted at foot clinic of Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), a tertiary care unit, Karachi-Pakistan. The duration of study was February 2018 to March 2018. Patients with Type-2 diabetes attending the outpatient department (OPD) of foot clinic, irrespective of their symptoms were included. Baseline demographic, anthropometric measurements and biochemical parameters were recorded. The ABI was calculated with both devices by an automated oscillometric machine and standard hand-held doppler with the same investigator. Results: Total of 93 patients with Type-2 diabetes, 18 (19.4%) females and 75(80.6%) males were recruited. Mean age was 54.67±9.59 years and mean systolic/diastolic blood pressure was 131.38±20.2/ 80.36±10.23mmHg. Most of the patients had poor glycemic control at presentation with a mean HbA1c of 9.56±2.44%. Mean standard handheld doppler ABI and automated oscillometric ABI was 1.28±1.08 and 1.07±0.23 for right foot (mean difference = 0.21; P= 0.075), and 1.14±0.45 and 1.1±0.25 for left foot (mean difference =0.04; P=0.434), respectively. Similarly, sensitivity and specificity between two modalities was observed 60% and 93.90% for right foot, meanwhile, 60% and 97.40% for left foot, respectively. Conclusion: An automated oscillometric method is comparable with standard handheld-doppler method. It is cost effective, convenient and less time consuming, can be widely used to measure ABI without special training.
Collapse
Affiliation(s)
- Shair Zaman Khan
- Dr. Shair Zaman Khan, FCPS, Endocrine Fellow (BIDE). Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), Karachi, Pakistan
| | - Awn-Bin-Zafar
- Dr. Awn Bin Zafar, MCPS, M.D. Assistant Professor, Department of Medicine (BMU), Consultant Physician (BIDE) Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), Karachi, Pakistan
| | - Nazish Waris
- Mrs. Nazish Waris, M.Phil., Ph.D. scholar, Research Officer, Research Department (BIDE) Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), Karachi, Pakistan
| | - Zahid Miyan
- Dr. Zahid Miyan, M.D. Assistant Professor, Department of Medicine (BMU), Consultant Physician (BIDE) Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), Karachi, Pakistan
| | - Muhammad Saif Ulhaque
- Dr. Muhammad Saif Ulhaque, MS (Dia., Endo), Registrar, Department of Medicine (BIDE) Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), Karachi, Pakistan
| | - Asher Fawwad
- Prof. Asher Fawwad, Ph.D. Chairman and Head of Department of Biochemistry (BMU), Research Director (BIDE). Baqai Institute of Diabetology and Endocrinology (BIDE), Baqai Medical University (BMU), Karachi, Pakistan
| |
Collapse
|
9
|
A national study of the prevalence and risk factors associated with peripheral arterial disease from China: The China Hypertension Survey, 2012–2015. Int J Cardiol 2019; 275:165-170. [DOI: 10.1016/j.ijcard.2018.10.047] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 08/07/2018] [Accepted: 10/12/2018] [Indexed: 11/21/2022]
|