Karlsson V, Sporre B, Fredén F, Ågren J. Randomized controlled trial of low vs high oxygen during neonatal anesthesia: Oxygenation, feasibility, and oxidative stress.
Paediatr Anaesth 2022;
32:1062-1069. [PMID:
35791748 PMCID:
PMC9546133 DOI:
10.1111/pan.14519]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 06/07/2022] [Accepted: 06/09/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND
To reduce risk for intermittent hypoxia a high fraction of inspired oxygen is routinely used during anesthesia induction. This differs from the cautious dosing of oxygen during neonatal resuscitation and intensive care and may result in significant hyperoxia.
AIM
In a randomized controlled trial, we evaluated oxygenation during general anesthesia with a low (23%) vs a high (80% during induction and recovery, and 40% during maintenance) fraction of inspired oxygen, in newborn infants undergoing surgery.
METHOD
Thirty-five newborn infants with postconceptional age of 35-44 weeks were included (17 infants in low and 18 in high oxygen group). Oxygenation was monitored by transcutaneous partial pressure of oxygen, pulse oximetry, and cerebral oxygenation. Predefined SpO2 safety targets dictated when to increase inspired oxygen.
RESULTS
At start of anesthesia, oxygenation was similar in both groups. Throughout anesthesia, the high oxygen group displayed significant hyperoxia with higher (difference-20.3 kPa, 95% confidence interval (CI)-28.4 to 12.2, p < .001) transcutaneous partial pressure of oxygen values than the low oxygen group. While SpO2 in the low oxygen group was lower (difference - 5.8%, 95% CI -9.3 to -2.4, p < .001) during anesthesia, none of the infants spent enough time below SpO2 safety targets to mandate supplemental oxygen, and cerebral oxygenation was within the normal range and not statistically different between the groups. Analysis of the oxidative stress biomarker urinary F2 -Isoprostane revealed no differences between the low and high oxygen group.
CONCLUSION
We conclude that in healthy newborn infants, use of low oxygen during general anesthesia was feasible, while the prevailing practice of using high levels of inspired oxygen resulted in significant hyperoxia. The trade-off between careful dosing of oxygen and risks of hypo- and hyperoxia in neonatal anesthesia should be further examined.
Collapse