1
|
Owens TC, Anton N, Attia MF. CT and X-ray contrast agents: Current clinical challenges and the future of contrast. Acta Biomater 2023; 171:19-36. [PMID: 37739244 DOI: 10.1016/j.actbio.2023.09.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 09/05/2023] [Accepted: 09/17/2023] [Indexed: 09/24/2023]
Abstract
Computed tomography (CT) is a powerful and widely used imaging technique in modern medicine. However, it often requires the use of contrast agents to visualize structures with similar radiographic density. Unfortunately, current clinical contrast agents (CAs) for CT have remained largely unchanged for decades and come with several significant drawbacks, including serious nephrotoxicity and short circulation half-lives. The next generation of CT radiocontrast agents should strive to be long-circulating, non-toxic, and non-immunogenic. Nanoparticle contrast agents have shown promise in recent years and are likely to comprise the majority of next-generation CT contrast agents. This review highlights the fundamental mechanism and background of X-ray and contrast agents. It also focuses on the challenges associated with current clinical contrast agents and provides a brief overview of potential future agents that are based on various materials such as lipids, polymers, dendrimers, metallic, and non-metallic inorganic nanoparticles (NPs). STATEMENT OF SIGNIFICANCE: We realized a need for clarification on a number of concerns related to the use of iodinated contrast material as debates regarding the safety of these agents with patients with kidney disease, shellfish allergies, and thyroid dysfunction remain ongoing in medical practice. This review was partially inspired by debates witnessed in medical practice regarding outdated misconceptions of contrast material that warrant clarification in translational and clinical arenas. Given that conversation around currently available agents is at somewhat of a high water mark, and nanoparticle research has now reached an unprecedented number of readers, we find that this review is timely and unique in the context of recent discussions in the field.
Collapse
Affiliation(s)
- Tyler C Owens
- Center for Nanotechnology in Drug Delivery and Division of Pharmacoengineering and Molecular Pharmaceutics, Eshelman School of Pharmacy, University of North Carolina at Chapel Hill, NC 27599, USA.
| | - Nicolas Anton
- Université de Strasbourg, INSERM, Regenerative Nanomedicine UMR 1260, Centre de Recherche en Biomédecine de Strasbourg (CRBS), F-67000 Strasbourg, France
| | - Mohamed F Attia
- Center for Nanotechnology in Drug Delivery and Division of Pharmacoengineering and Molecular Pharmaceutics, Eshelman School of Pharmacy, University of North Carolina at Chapel Hill, NC 27599, USA.
| |
Collapse
|
2
|
Mahieu R, Donders DNV, Dankbaar JW, de Bree R, de Keizer B. CT Lymphography Using Lipiodol® for Sentinel Lymph Node Biopsy in Early-Stage Oral Cancer. J Clin Med 2022; 11:jcm11175129. [PMID: 36079061 PMCID: PMC9456579 DOI: 10.3390/jcm11175129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 08/27/2022] [Accepted: 08/28/2022] [Indexed: 11/18/2022] Open
Abstract
This study evaluated sentinel lymph node (SLN) identification with CT lymphography (CTL) following peritumoral administration of Lipiodol® relative to conventional 99mTc-nanocolloid lymphoscintigraphy (including SPECT/CT) in 10 early-stage oral cancer patients undergoing SLN biopsy. Patients first underwent early dynamic and static scintigraphy after peritumoral administration of 99mTc-nanocolloid. Subsequently, Lipiodol® was administered at the same injection sites, followed by fluoroscopy and CT acquisition. Finally, late scintigraphy and SPECT/CT were conducted, enabling the fusion of late CTL and SPECT imaging. The next day, designated SLNs were harvested, radiographically examined for Lipiodol® uptake and histopathologically assessed. Corresponding images of CT, 99mTc-nanocolloid lymphoscintigraphy and SPECT/late CTL fusion were evaluated. 99mTc-nanocolloid lymphoscintigraphy identified 21 SLNs, of which 7 were identified with CTL (33%). CTL identified no additional SLNs and failed to identify any SLNs in four patients (40%). Out of six histopathologically positive SLNs, two were identified by CTL (33%). Radiographic examination confirmed Lipiodol® uptake in seven harvested SLNs (24%), of which five were depicted by CTL. CTL using Lipiodol® reached a sensitivity of 50% and a negative predictive value (NPV) of 75% (median follow-up: 12.3 months). These results suggest that CTL using Lipiodol® is not a reliable technique for SLN mapping in early-stage oral cancer.
Collapse
Affiliation(s)
- Rutger Mahieu
- Department of Head and Neck Surgical Oncology, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
| | - Dominique N. V. Donders
- Department of Head and Neck Surgical Oncology, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
| | - Jan Willem Dankbaar
- Department of Radiology, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
| | - Remco de Bree
- Department of Head and Neck Surgical Oncology, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
- Correspondence: ; Tel.: +31-887550819
| | - Bart de Keizer
- Department of Radiology, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
- Department of Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
| |
Collapse
|
3
|
Miyasato DL, Mohamed AW, Zavaleta C. A path toward the clinical translation of nano-based imaging contrast agents. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 13:e1721. [PMID: 33938151 DOI: 10.1002/wnan.1721] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 04/02/2021] [Accepted: 04/07/2021] [Indexed: 12/15/2022]
Abstract
Recently, nanoparticles have evolved ubiquitously in therapeutic applications to treat a range of diseases. Despite their regular use as therapeutic agents in the clinic, we have yet to see much progress in their clinical translation as diagnostic imaging agents. Several clinical and preclinical studies support their use as imaging contrast agents, but their use in the clinical setting has been limited to off-label imaging procedures (i.e., Feraheme). Since diagnostic imaging has been historically used as an exploratory tool to rule out disease or to screen patients for various cancers, nanoparticle toxicity remains a concern, especially when introducing exogenous contrast agents into a potentially healthy patient population, perhaps rationalizing why several nano-based therapeutic agents have been clinically translated before nano-based imaging agents. Another potential hindrance toward their clinical translation could be their market potential, as most therapeutic drugs have higher earning potential than small-molecule imaging contrast agents. With these considerations in mind, perhaps a clinical path forward for nano-based imaging contrast agents is to help guide/manage therapy. Several studies have demonstrated the ability of nanoparticles to produce more accurate imaging preoperatively, intraoperatively, and postoperatively. These applications illustrate a more reliable method of cancer detection and treatment that can prevent incomplete tumor resection and incorrect assessment of tumor progression following treatment. The aim of this review is to highlight the research that supports the use of nanoparticles in biomedical imaging applications and offer a new perspective to illustrate how nano-based imaging agents have the potential to better inform therapeutic decisions. This article is categorized under: Diagnostic Tools > In Vivo Nanodiagnostics and Imaging.
Collapse
Affiliation(s)
- Dominie L Miyasato
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.,Michelson Center for Convergent Bioscience, University of Southern California, Los Angeles, California, USA
| | - Ahmed W Mohamed
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.,Michelson Center for Convergent Bioscience, University of Southern California, Los Angeles, California, USA
| | - Cristina Zavaleta
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.,Michelson Center for Convergent Bioscience, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
4
|
Mahieu R, de Maar JS, Nieuwenhuis ER, Deckers R, Moonen C, Alic L, ten Haken B, de Keizer B, de Bree R. New Developments in Imaging for Sentinel Lymph Node Biopsy in Early-Stage Oral Cavity Squamous Cell Carcinoma. Cancers (Basel) 2020; 12:cancers12103055. [PMID: 33092093 PMCID: PMC7589685 DOI: 10.3390/cancers12103055] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/03/2020] [Accepted: 10/15/2020] [Indexed: 12/18/2022] Open
Abstract
Sentinel lymph node biopsy (SLNB) is a diagnostic staging procedure that aims to identify the first draining lymph node(s) from the primary tumor, the sentinel lymph nodes (SLN), as their histopathological status reflects the histopathological status of the rest of the nodal basin. The routine SLNB procedure consists of peritumoral injections with a technetium-99m [99mTc]-labelled radiotracer followed by lymphoscintigraphy and SPECT-CT imaging. Based on these imaging results, the identified SLNs are marked for surgical extirpation and are subjected to histopathological assessment. The routine SLNB procedure has proven to reliably stage the clinically negative neck in early-stage oral squamous cell carcinoma (OSCC). However, an infamous limitation arises in situations where SLNs are located in close vicinity of the tracer injection site. In these cases, the hotspot of the injection site can hide adjacent SLNs and hamper the discrimination between tracer injection site and SLNs (shine-through phenomenon). Therefore, technical developments are needed to bring the diagnostic accuracy of SLNB for early-stage OSCC to a higher level. This review evaluates novel SLNB imaging techniques for early-stage OSCC: MR lymphography, CT lymphography, PET lymphoscintigraphy and contrast-enhanced lymphosonography. Furthermore, their reported diagnostic accuracy is described and their relative merits, disadvantages and potential applications are outlined.
Collapse
Affiliation(s)
- Rutger Mahieu
- Department of Head and Neck Surgical Oncology, University Medical Center Utrecht, University of Utrecht, 3584 CX Utrecht, The Netherlands;
| | - Josanne S. de Maar
- Division of Imaging and Oncology, University Medical Center Utrecht, University of Utrecht, 3584 CX Utrecht, The Netherlands; (J.S.d.M.); (R.D.); (C.M.)
| | - Eliane R. Nieuwenhuis
- Department of Magnetic Detection & Imaging, University of Twente, 7522 NB Enschede, The Netherlands; (E.R.N.); (L.A.); (B.t.H.)
| | - Roel Deckers
- Division of Imaging and Oncology, University Medical Center Utrecht, University of Utrecht, 3584 CX Utrecht, The Netherlands; (J.S.d.M.); (R.D.); (C.M.)
| | - Chrit Moonen
- Division of Imaging and Oncology, University Medical Center Utrecht, University of Utrecht, 3584 CX Utrecht, The Netherlands; (J.S.d.M.); (R.D.); (C.M.)
| | - Lejla Alic
- Department of Magnetic Detection & Imaging, University of Twente, 7522 NB Enschede, The Netherlands; (E.R.N.); (L.A.); (B.t.H.)
| | - Bennie ten Haken
- Department of Magnetic Detection & Imaging, University of Twente, 7522 NB Enschede, The Netherlands; (E.R.N.); (L.A.); (B.t.H.)
| | - Bart de Keizer
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands;
| | - Remco de Bree
- Department of Head and Neck Surgical Oncology, University Medical Center Utrecht, University of Utrecht, 3584 CX Utrecht, The Netherlands;
- Correspondence: ; Tel.: +31-88-7550819
| |
Collapse
|