1
|
Inci K, Gürsel G. Accuracy of Pocket-sized Ultrasound Devices to Evaluate Inferior Vena Cava Diameter and Variability in Critically Ill Patients. Indian J Crit Care Med 2024; 28:369-374. [PMID: 38585318 PMCID: PMC10998516 DOI: 10.5005/jp-journals-10071-24674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 02/14/2024] [Indexed: 04/09/2024] Open
Abstract
Purpose By using inferior vena cava (IVC) measurements, clinicians can detect fluid status and responsiveness and find out the etiology of hypotension, acute heart failure, and sepsis easier. Pocket-sized ultrasound devices (PSUD) may take this advantage a few steps further by their lower costs, user-friendly interface, and easily applicable structure.In this study, we aimed to determine the diagnostic value of a PSUD compared with a standard ultrasound device (SD) for the measurement of IVC diameter (IVCD) and its respiratory variability. Materials and methods We measured the inspiratory, expiratory diameters of IVC, and calculated the inferior vena cava collapsibility index (IVCCI). We investigated 42 intensive care unit (ICU) patients. Results There was no difference in inspiratory (PSUD: 1.34 ± 0.67 cm; SD: 1.35 ± 0.68 cm) and expiratory (PSUD: 1.98 ± 0.53 cm; SD: 2.01 ± 0.49 cm) IVCD among measurements with PSUD and SD (p > 0.05). There was also no difference between IVCCI's measured with PSUD (39 ± 20%) and SD (39 ± 20%) (p > 0.05). The Bland-Altman analysis revealed that the width of 95% limits of agreement were similar for both devices. There was a good inter-device agreement among PSUD and SD for measurements of IVCD, and there was no difference between IVCCI's measured using both ultrasound devices. Conclusion We support that the idea of a PSUD is as reliable as a SD for IVC measurements. How to cite this article Inci K, Gürsel G. Accuracy of Pocket-sized Ultrasound Devices to Evaluate Inferior Vena Cava Diameter and Variability in Critically Ill Patients. Indian J Crit Care Med 2024;28(4):369-374.
Collapse
Affiliation(s)
- Kamil Inci
- Faculty of Medicine, Department of Internal Medicine, Division of Critical Care, Gazi University, Ankara, Turkey
| | - Gül Gürsel
- Faculty of Medicine, Department of Pulmonary Critical Care Medicine, Gazi University, Ankara, Turkey
| |
Collapse
|
2
|
Pałac M, Linek P. Intra-Rater Reliability of Shear Wave Elastography for the Quantification of Respiratory Muscles in Adolescent Athletes. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22176622. [PMID: 36081075 PMCID: PMC9460867 DOI: 10.3390/s22176622] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 08/25/2022] [Accepted: 08/29/2022] [Indexed: 05/09/2023]
Abstract
The aim of this study was to assess the intra-rater reliability and agreement of diaphragm and intercostal muscle elasticity and thickness during tidal breathing. The diaphragm and intercostal muscle parameters were measured using shear wave elastography in adolescent athletes. To calculate intra-rater reliability, intraclass correlation coefficient (ICC) and Bland-Altman statistics were used. The reliability/agreement for one-day both muscle measurements (regardless of probe orientation) were at least moderate. During the seven-day interval between measurements, the reliability of a single measurement depended on the measured parameter, transducer orientation, respiratory phase, and muscle. Excellent reliability was found for diaphragm shear modulus at the peak of tidal expiration in transverse probe position (ICC3.1 = 0.91-0.96; ICC3.2 = 0.95), and from poor to excellent reliability for the intercostal muscle thickness at the peak of tidal inspiration with the longitudinal probe position (ICC3.1 = 0.26-0.95; ICC3.2 = 0.15). The overall reliability/agreement of the analysed data was higher for the diaphragm measurements (than the intercostal muscles) regardless of the respiratory phase and probe position. It is difficult to identify a more appropriate probe position to examine these muscles. The shear modulus/thickness of the diaphragm and intercostal muscles demonstrated good reliability/agreement so this appears to be a promising technique for their examination in athletes.
Collapse
Affiliation(s)
- Małgorzata Pałac
- Musculoskeletal Elastography and Ultrasonography Laboratory, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
- Musculoskeletal Diagnostic and Physiotherapy—Research Team, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
| | - Paweł Linek
- Musculoskeletal Elastography and Ultrasonography Laboratory, Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
- Musculoskeletal Diagnostic and Physiotherapy—Research Team, The Jerzy Kukuczka Academy of Physical Education, 40-065 Katowice, Poland
- Correspondence: ; Tel.: +48-661-768-601
| |
Collapse
|
3
|
Chu SE, Lu JX, Chang SC, Hsu KH, Goh ZNL, Seak CK, Seak JCY, Ng CJ, Seak CJ. Point-of-care application of diaphragmatic ultrasonography in the emergency department for the prediction of development of respiratory failure in community-acquired pneumonia: A pilot study. Front Med (Lausanne) 2022; 9:960847. [PMID: 36059832 PMCID: PMC9428711 DOI: 10.3389/fmed.2022.960847] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 07/18/2022] [Indexed: 12/04/2022] Open
Abstract
Background Early recognition of patients with community-acquired pneumonia (CAP) at risk of poor outcomes is crucial. However, there is no effective assessment tool for predicting the development of respiratory failure in patients with CAP. Diaphragmatic ultrasonography (DUS) is a novel technique developed for evaluating diaphragmatic function via measurements of the diaphragm thickening fraction (DTF) and diaphragm excursion (DE). This study evaluated the accuracy of DUS in predicting the development of respiratory failure in patients with CAP, as well as the feasibility of its use in the emergency department (ED) setting. Materials and methods This was a single-center prospective cohort study. We invited all patients with ED aged ≥ 20 years who were diagnosed with CAP of pneumonia severity index (PSI) SIe diagnosed with CAP of pneumonia severe with respiratory failure or septic shock were excluded. Two emergency physicians performed DUS to obtain DTF and DE measurements. Data were collected to calculate PSI, CURB-65 score, and Infectious Diseases Society of America/American Thoracic Society severity criteria. Study endpoints were taken at the development of respiratory failure or 30 days post-ED presentation. Continuous variables were analyzed using T-tests, while categorical variables were analyzed using chi-square tests. Further logistic regression and receiver operating characteristic curve analyses were performed to examine the ability to predict the development of respiratory failure. Intra- and inter-rater reliability was examined with intraclass correlation coefficients (ICCs). Results In this study, 13 of 50 patients with CAP enrolled developed respiratory failure. DTF was found to be an independent predictor (OR: 0.939, p = 0.0416). At the optimal cut-off point of 23.95%, DTF had 69.23% of sensitivity, 83.78% of specificity, 88.57% of negative predictive value, and 80% of accuracy. Intra- and inter-rater analysis demonstrated good consistency (intra-rater ICC 0.817, 0.789; inter-rater ICC 0.774, 0.781). Conclusion DUS assessment of DTF may reliably predict the development of respiratory failure in patients with CAP presenting to the ED. Patients with DTF > 23.95% may be considered for outpatient management.
Collapse
Affiliation(s)
- Sheng-En Chu
- Department of Emergency Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
- School of Medicine, Institute of Emergency and Critical Care Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Jian-Xun Lu
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Department of Emergency Medicine, Lin-Kou Medical Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan
| | - Shi-Chuan Chang
- School of Medicine, Institute of Emergency and Critical Care Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Department of Chest Medicine, National Yang Ming Chiao Tung University Hospital, Yilan, Taiwan
| | - Kuang-Hung Hsu
- Department of Emergency Medicine, Lin-Kou Medical Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan
- Healthy Aging Research Center, Chang Gung University, Taoyuan, Taiwan
- Laboratory for Epidemiology, Department of Health Care Management, Chang Gung University, Taoyuan, Taiwan
- Research Center for Food and Cosmetic Safety, College of Human Ecology, Chang Gung University of Science and Technology, Taoyuan, Taiwan
- Department of Safety, Health and Environmental Engineering, Ming Chi University of Technology, Taipei, Taiwan
| | | | - Chen-Ken Seak
- Sarawak General Hospital, Kuching, Sarawak, Malaysia
| | | | - Chip-Jin Ng
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Department of Emergency Medicine, Lin-Kou Medical Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan
| | - Chen-June Seak
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
- Department of Emergency Medicine, Lin-Kou Medical Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan
- Department of Emergency Medicine, New Taipei Municipal Tucheng Hospital, New Taipei City, Taiwan
- *Correspondence: Chen-June Seak,
| |
Collapse
|
4
|
ALTINKAYA ÇAVUŞ M, GÖKBULUT BEKTAŞ Ş, SİPAHİOĞLU H, ERTÜRK ZARARSIZ G, TURAN S. Diyafram ultrasonografisinin weaning başarısını tahmin etmedeki gücü. CUKUROVA MEDICAL JOURNAL 2022. [DOI: 10.17826/cumj.1037159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Amaç: Bu çalışmada amaç; diyafram kalınlığının weaning üzerine etkilerini ultrasonografi (USG) ile değerlendirmektir.
Gereç ve Yöntem: Prospektif olarak yapılan bu çalışmada; hastaların demografik özellikleri, yoğun bakıma yatış ve mekanik ventilasyon endikasyonları, ek hastalıkları, diyafram kalınlığı, Sıralı Organ Yetmezliği Değerlendirmesi (SOFA) skoru ve Basitleştirilmiş Akut Fizyoloji Skoru (SAPS) II, mortalite oranı, periferik oksijen satürasyonu (SpO2), IMV süresi, dakika hacmi, solunum sayısı (RR), ekspiratuar hacimleri, RSBI değerleri kaydedildi.Hastalar invaziv mekanik ventilatör (IMV) basınç desteği (PS) modunda 30 dakika boyunca spontan olarak ventile edildi . Diyafram kalınlığı (DT), B moduna ayarlanmış 7-10 MHz lineer ultrason probu kullanılarak ölçüldü. Sağ hemidiyafram, 8. ve 10. interkostal boşluklar arasındaki midaksiller çizgide diyafram ve göğüs kafesinin birleştiği bölgede görüntülendi. Ölçümler sonrasında hastalar stabil hale geldikten sonra 1 saat boyunca T-tüpe alındı. T-tüpte spontan solunum denemeleri (SBT)'ni başarıyla tamamlayan hastalar ekstübe edildi. Hastalar başarılı ve başarısız weaning olmak üzere 2 gruba ayrıldı.
Bulgular: Toplam 72 hasta çalışmaya dahil edilme kriterlerini sağlayarak değerlendirilmeye alındı. Hastaların 4 tanesi 24 saatten daha kısa süre IMV desteği aldığı için çalışma dışı bırakıldı. Diyafram kalınlık indeksi (DTI) ve diyafram kalınlaşma fraksiyonu (DTF) oranlarında gruplar arasında bir farklılık gözlenmedi. İnspirasyon sonunu diyafram kalınlığı (DTV) ve ekspirasyon sonunu diyafram kalınlığı (DFRV) olarak tanımlanan diyaframın kalınlık ölçümleri başarılı weaning grubunda daha yüksekti. Weaning başarısını tahmin etmek için DTV'nin en iyi eşik değeri 0.72, DFRV değeri 0.669 olarak bulundu.
Sonuç: Weaning başarısı diyafram fonksiyonları, diyafram kalınlık parametreleri ve akciğer kapasiteleri ile yakından ilişkilidir. USG, diyaframı değerlendirmek için kullanılabilecek pratik, hasta başı uygulanabilen, noninvaziv bir yöntemdir. DTV ve DFRV weaning sürecinde başarıyı tahmin edebilecek parametreler arasındadır. DTF ve DTI weaning başarısını öngörmede yetersiz bulundu.
Collapse
Affiliation(s)
- Mine ALTINKAYA ÇAVUŞ
- Department of Intensive Care, University of Health Sciences, Kayseri City Hospital, Kayseri, Turkey
| | | | - Hilal SİPAHİOĞLU
- SAĞLIK BİLİMLERİ ÜNİVERSİTESİ, KAYSERİ SAĞLIK UYGULAMA VE ARAŞTIRMA MERKEZİ
| | | | - Sema TURAN
- SAĞLIK BİLİMLERİ ÜNİVERSİTESİ, ANKARA SAĞLIK UYGULAMA VE ARAŞTIRMA MERKEZİ
| |
Collapse
|
5
|
Mohamed RSE, Mohamed ASE, Fathalah WF, Mohamed MF, Ahmed AA. The role of diaphragmatic ultrasound as a predictor of successful extubation from mechanical ventilation in respiratory intensive care unit. THE EGYPTIAN JOURNAL OF BRONCHOLOGY 2021. [PMCID: PMC8593640 DOI: 10.1186/s43168-021-00095-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Background The diaphragm muscle whose dysfunction may be very common in patients undergoing mechanical ventilation (Ferrari G, De Filippi G, Elia F, Panero F, Volpicelli G, Aprà F. Crit Ultrasound J 6:8, 2014). Aim: To evaluate real-time ultrasound in the evaluation of diaphragmatic thickening, thickening fraction, and/or excursion to predict extubation outcomes. We aimed to compare these parameters with other traditional weaning measures is a fundamental. Results Out of 80 included patients, 20 (25%) have failed extubation. Diaphragmatic thickening (DT), thickening fraction (DTF), and/or excursion (DE) were significantly higher in the successful group compared to those who failed extubation (p < 0.05). Cutoff values of diaphragmatic measures associated with successful extubation (during tidal breathing) were ≥ 17 mm for DE; ≥ 2.1 cm for DT inspiration; ≥ 15.5 mm for DT expiration, functional residual capacity (FRC); and ≥ 32.82% for DTF %, giving 68%, 95%, 62%, and 90% sensitivity, respectively, and 65%, 100%, 100%, and 75% specificity, respectively. Cutoff values of diaphragmatic parameters associated with successful extubation (during deep breathing) were > 28.5 mm DT Insp, total lung capacity (TLC); >22.5mm DT Exp (RV); >37 DTF %; and > 31 mm DE, giving 100%, 73%, 97%, and 75% sensitivity and 65%, 75%, 100%, and 55% specificity, respectively. Rapid shallow breathing index (RSBI) had 47% sensitivity but 90% specificity. Conclusion Ultrasound evaluation of diaphragmatic parameters could be a good predictor of weaning in patients who passed the T-tube.
Collapse
|
6
|
Are pocket sized ultrasound devices sufficient in the evaluation of lung ultrasound patterns and aeration scoring in pulmonary ICU patients? J Clin Monit Comput 2020; 35:1491-1499. [PMID: 33170405 PMCID: PMC7653453 DOI: 10.1007/s10877-020-00617-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Accepted: 11/02/2020] [Indexed: 12/16/2022]
Abstract
Lung ultrasound (LUS) is a practical diagnostic tool for several lung pathologies. Pocket sized USG devices (PSUDs) are more affordable, accessible, practical, and learning to use them is easier than standard ultrasound devices (SUDs). Their capability in image quality have been found as comparable with standard USG machines. Studies have been showing that these devices can be useful as much as SUDs in the evaluation of heart, abdomen, vascular structures, diaphragm and optic nerve. The aim of this study is to compare PSUD with a standard ultrasound devices (SUD) in the evaluation of LUS patterns such as alveolar, interstitial syndromes and lung aeration score (LAS). Study performed in an University Hospital Pulmonary ICU. All patients older than 18 years old were included in this study. The sector probe of SUD (Vivid-Q) and PSUD (Vscan) were used for investigation of A lines, interstitial (B lines), alveolar syndromes (consolidation, hepatisation, air bronchograms) and pleural effusion. 33 patients were included in the study. When PSUD was compared with SUD in terms of total B2 count, and LAS in the right, left and both lung, there was an agreement without proportional bias according to Bland Altman test. There was also good inter class correlation coefficient value as greater than 0.8 and 0.7 between two physicians in terms of counting of total B1, B2, total B lines and calculating of total LAS for SUD and PSUD respectively. PSUDs is a reliable and valid method for evaluation of LUS patterns like SUDs.
Collapse
|
7
|
Kalın BS, Gürsel G. Does it make difference to measure diaphragm function with M mode (MM) or B mode (BM)? J Clin Monit Comput 2019; 34:1247-1257. [PMID: 31782086 DOI: 10.1007/s10877-019-00432-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 11/25/2019] [Indexed: 01/12/2023]
Abstract
Diaphragm dysfunction occurs in mechanically ventilated subjects. Recent literature suggests that diaphragm thickening fraction (DTF) measured by ultrasound can be useful to predict weaning outcome. However, there is no standardized approach in the measurement of diaphragm thickness (DT) and limited data exists comparing different measurement techniques of diaphragm thickness (M mode-MM or B mode-BM). The goal of this study was to compare MM with BM in the measurements of DT and excursion in the ICU subjects. DT measurements were obtained from the right diaphragm during tidal and maximal inspiratory breathing. Three measurements of the DT were taken both in MM and BM and their mean values were calculated. DT was measured during inspiration and expiration and DTF was calculated. Excursion of diaphragm was also measured with MM and BM during tidal and maximal inspiratory breathing. Bias and agreement between the two measurement methods were evaluated with Bland and Altman test. Sixty-two subjects were enrolled in the study. While 25 (40%) subjects were receiving invasive mechanical ventilation, 14 (23%) subjects ventilated noninvasively. There were no significant difference between the measurement results of MM and BM. BM and MM tidal diaphragm measurements during the inspiratory (0.3 ± 0.08 and 0.31 ± 0.08 cm; P = 0.022), expiratory (0.24 ± 0.07 and 0.24 ± 0.07 cm; P = 0.315) phases and tidal DTF were (27 ± 16 and 31 ± 14%, P = 0.089) respectively. Results of our study suggests that except tidal inspiratory diaphragm thickness, all thickness and excursion measurements with MM and BM are very compatible with each other. Further studies are necessarry to confirm our results and to standardize the measurements of diaphragm.
Collapse
Affiliation(s)
- Burhan Sami Kalın
- Division of Critical Care, Department of Internal Medicine, Gazi University School of Medicine, Ankara, Turkey. .,Department of Pulmonary Critical Care Medicine, Gazi University School of Medicine, 06560, Ankara, Turkey.
| | - Gül Gürsel
- Department of Pulmonary Critical Care Medicine, Gazi University School of Medicine, 06560, Ankara, Turkey
| |
Collapse
|
8
|
Turton P, Hay R, Welters I. Assessment of peripheral muscle thickness and architecture in healthy volunteers using hand-held ultrasound devices; a comparison study with standard ultrasound. BMC Med Imaging 2019; 19:69. [PMID: 31426754 PMCID: PMC6699072 DOI: 10.1186/s12880-019-0373-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 08/12/2019] [Indexed: 01/14/2023] Open
Abstract
Background Pocket-sized ultrasound devices are increasingly used in a variety of clinical situations, and perform well against standard ultrasound machines. We sought to investigate if a pocket-sized ultrasound device can assess muscle thickness and architecture in healthy volunteers. Methods Healthy male volunteers (n = 21) across a range of ages were recruited to the study. Laying supine, ultrasound images were taken from the right anterior and lateral thigh. Thickness of the rectus femoris (RFMT), vastus intermedius (VIMT), and the two combined (anterior thigh, AMT) were measured, along with thickness of vastus lateralis (VLMT), pennation angle (VLPA) and derived fascicle length (VLFL). These scans were performed initially using a pocket-sized ultrasound (VScan) and then using a standard device (Telemed Echoblaster 128). Results In all six variables, there was no significant difference between the two sets of measurements. Intra-class correlation co-efficients (ICC) for VLMT, VLPA, and AMT were all excellent (0.93, 0.89, 0.90 respectively) with the derived value of VLFL having an ICC of 0.84. All ICC values were statistically significant. Regression analysis demonstrated no evidence of proportional bias in any of the measured or derived variables. Conclusion A pocket-sized ultrasound device gives similar measurements of lower limb muscle thickness and architecture as a standard device in healthy volunteers.
Collapse
Affiliation(s)
- Peter Turton
- Institute of Aging and Chronic Disease, University of Liverpool, Liverpool, UK.
| | - Richard Hay
- Royal Liverpool University Hospital, Liverpool, UK
| | - Ingeborg Welters
- Institute of Aging and Chronic Disease, University of Liverpool, Liverpool, UK
| |
Collapse
|
9
|
Özdemir U, Çimen M, Güney T, Gürsel G. Validity and reliability of pocket-sized ultrasound devices in measurement of optic nerve sheath diameter in ICU patients. J Clin Monit Comput 2019; 34:597-605. [PMID: 31278545 PMCID: PMC7223003 DOI: 10.1007/s10877-019-00351-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 07/01/2019] [Indexed: 12/19/2022]
Abstract
The measurement of the optic nerve sheath diameter (ONSD) by ultrasonography (USG) is particularly important for intracranial pressure (ICP) monitoring when invasive measurements are not possible or are contraindicated. Standard USG (SUDs) devices can be bulky and may break down the workflow. The validity and reliability of pocket-sized USG devices (PSUDs) compared to SUDs for ONSD measurement has not been investigated, yet. We compared the reliability and validity of PSUDs with SUDs for ONSD measurement. 35 patients were included in the study. ONSD measurements with PSUDs and SUDs were performed by two clinicians as three different measurements in both sagittal and transverse axis of the eye. There was agreement between mean transverse ONSD (mtONSD), mean sagittal ONSD (msONSD), and mean ONSD(mONSD) values measured with each device according to Bland-Altman test (p = 0.166, p = 0.135, p = 0.066, respectively) with no proportional bias (p = 0.544, p = 0.868, p = 0.929, respectively). Intraclass correlation coefficients (ICC) were found to be greater than 0.7 for mtONSD, msONSD, and mONSD values measured by SUD (ICC = 0.790, ICC = 0.817, and ICC = 0.844, respectively). Similarly, for mtONSD, msONSD, and mONSD values measured by PSUD, ICC were found greater than 0.7 (ICC = 0.763, ICC = 0.814, and ICC = 0.843, respectively). There was no statistically significant difference between mtONSD and msONSD (p = 0.441 for SUD and p = 0.893 for PSUD). There was a good correlation between mtONSD and msONSD (r = 0.767 for SUD and r = 0.816 for PSUD). The total variance between three different measurements in the transverse and sagittal axis was ± 0.6 mm. PSUDs can be used with similar validity and reliability as SUDs for ONSD measurement.
Collapse
Affiliation(s)
- Uğur Özdemir
- Division of Critical Care Medicine, Department of Internal Medicine, Gazi University School of Medicine, Ankara, Turkey.
| | - Meltem Çimen
- Division of Critical Care Medicine, Department of Anesthesiology, Gazi University School of Medicine, Ankara, Turkey
| | - Tuba Güney
- Division of Critical Care Medicine, Department of Neurology, Gazi University School of Medicine, Ankara, Turkey
| | - Gül Gürsel
- Department of Pulmonary Critical Care Medicine, Gazi University School of Medicine, Ankara, Turkey
| |
Collapse
|
10
|
Rykkje A, Carlsen JF, Nielsen MB. Hand-Held Ultrasound Devices Compared with High-End Ultrasound Systems: A Systematic Review. Diagnostics (Basel) 2019; 9:diagnostics9020061. [PMID: 31208078 PMCID: PMC6628329 DOI: 10.3390/diagnostics9020061] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 06/10/2019] [Accepted: 06/13/2019] [Indexed: 12/14/2022] Open
Abstract
The aim of this study was to review the scientific literature available on the comparison of hand-held ultrasound devices with high-end systems for abdominal and pleural applications. PubMed, Embase, Web of Science and Cochrane were searched following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Original research describing hand-held ultrasound devices compared with high-end systems was included and assessed using Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2. The search was limited to articles published since 1 January 2012. A total of 2486 articles were found and screened by title and abstract. A total of 16 articles were chosen for final review. All of the included articles showed good overall agreement between hand-held and high-end ultrasound systems. Strong correlations were found when evaluating ascites, hydronephrosis, pleural cavities, in detection of abdominal aortic aneurysms and for use with obstetric and gynaecological patients. Other articles found good agreement for cholelithiasis and for determining the best site for paracentesis. QUADAS-2 analysis suggested few risks of bias and almost no concerns regarding applicability. For distinct clinical questions, hand-held devices may be a valuable supplement to physical examination. However, evidence is inadequate, and more research is needed on the abdominal and pleural use of hand-held ultrasound with more standardised comparisons, using only blinded reviewers.
Collapse
Affiliation(s)
- Alexander Rykkje
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
| | | | - Michael Bachmann Nielsen
- Department of Radiology, Copenhagen University Hospital, Rigshospitalet, 2100 Copenhagen, Denmark.
| |
Collapse
|
11
|
Turton P, ALAidarous S, Welters I. A narrative review of diaphragm ultrasound to predict weaning from mechanical ventilation: where are we and where are we heading? Ultrasound J 2019; 11:2. [PMID: 31359260 PMCID: PMC6638615 DOI: 10.1186/s13089-019-0117-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 02/08/2019] [Indexed: 12/19/2022] Open
Abstract
Background The use of ultrasound to visualize the diaphragm is well established. Over the last 15 years, certain indices of diaphragm function, namely diaphragm thickness, thickening fraction and excursion have been established for mechanically ventilated patients to track changes in diaphragm size and function over time, to assess and diagnose diaphragmatic dysfunction, and to evaluate if these indices can predict successful liberation from mechanical ventilation. In the last 2 years, three meta-analyses and a systematic review have assessed the usability of diaphragmatic ultrasound to predict successful weaning. Since then, further data have been published on the topic. Conclusions The aim of this narrative review is to briefly describe the common methods of diaphragmatic function assessment using ultrasound techniques, before summarizing the major points raised by the recent reviews. A narrative summary of the most recent data will be presented, before concluding with a brief discussion of future research directions in this field.
Collapse
Affiliation(s)
- Peter Turton
- Critical Care Unit, Royal Liverpool University Hospital, Liverpool, UK. .,Institute of Aging and Chronic Disease, University of Liverpool, Liverpool, UK.
| | - Sondus ALAidarous
- Critical Care Unit, Royal Liverpool University Hospital, Liverpool, UK.,Institute of Infection and Global Health, University of Liverpool, Liverpool, UK
| | - Ingeborg Welters
- Critical Care Unit, Royal Liverpool University Hospital, Liverpool, UK.,Institute of Aging and Chronic Disease, University of Liverpool, Liverpool, UK
| |
Collapse
|