1
|
Alkhudhairy F. Canal disinfection using Nd: YAG Laser, synchronized microbubble-photodynamic activation, and carbon quantum dots on microhardness, smear layer removal, and extrusion bond strength of zirconia post to canal dentin. An invitro scanning electron microscopic analysis. Microsc Res Tech 2024; 87:2043-2052. [PMID: 38646819 DOI: 10.1002/jemt.24584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/16/2024] [Accepted: 04/11/2024] [Indexed: 04/23/2024]
Abstract
Evaluation of the impact of the latest root canal disinfectant, that is carbon quantum dots (CQDs), synchronized microbubble-photodynamic activation (SYMPA), and Nd: YAG laser along with ethylenediaminetetraacetic acid (EDTA) as a final irrigant on the Marten hardness (MH), smear layer (SL) removal, and extrusion bond strength (EBS) of zirconia post to the canal dentin. Eighty intact single-rooted premolars were obtained and disinfected using 0.5% chloramine-T solution. Root canal preparation was performed using ProTaper files followed by obturation. The post space was prepared for prefabricated zirconia post and all the teeth were randomly divided into four groups based on the disinfection used (n = 20 each) Group 1: 5.25% NaOCl + 17% EDTA (Control), Group 2: Nd: YAG laser + 17% EDTA, Group 3: SYMPA + 17% EDTA, and Group 4: CQDs + 17% EDTA. MH, SL removal, and EBS of zirconia post-bonded to root dentin were performed using a microhardness tester, scanning electron microscope (SEM), and universal testing machine, respectively. Both intragroup and intergroup comparisons were performed using one-way analysis of variance (ANOVA) and posthoc-Tukey test for significant difference (p < .05). Group 2 samples (Nd: YAG laser + 17% EDTA) (0.24 ± 0.06 GPa) exhibited highest values of MH. Samples in group 3 (SYMPA + 17% EDTA) treated teeth unveiled the lowest MH scores (0.13 ± 0.02 GPa). Moreover, the coronal third of Group 3 specimens (SYMPA and 17% EDTA) (1.54 ± 0.31) eliminated SL from the canal with the greatest efficacy as well as presented the highest EBS (10.13 ± 0.69 MPa). However, the apical third of Group 1 samples (5.25% NaOCl + 17% EDTA) (2.95 ± 0.33) exhibited the least efficient elimination of SL from the radicular dentin as well as the lowest bond strength (5.11 ± 0.19 MPa) of zirconia post to the dentin. The SYMPA technique with 17% EDTA proved highly effective in removing the SL from canal dentin and enhancing the EBS of zirconia posts. The least preferable method for SL removal and MH improvement was found to be 5.25% NaOCl + 17% EDTA. CQDs and Nd: YAG laser demonstrated satisfactory smear layer removal properties from the canal, along with achieving appropriate bond strength of zirconia posts. RESEARCH HIGHLIGHTS: Nd: YAG laser and 17% EDTA as canal disinfectant exhibited the highest values of MH. Specimens irrigated with SYMPA and 17% EDTA eliminated SL from the canal with the greatest efficacy. The coronal third of Group 3 (SYMPA + 17% EDTA) samples unveiled the highest zirconia post-bond integrity score to the canal dentin. Cohesive failure was a dominant failure type among different experimental groups.
Collapse
Affiliation(s)
- Fahad Alkhudhairy
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
2
|
Abdul Hadi Ahmed R, Mohammed Ali Hussein B. Effect of Laser Treatment of Root Dentine on Retention of Dental Fiber Post in Endodontically Treated Teeth: An In Vitro Study. J Lasers Med Sci 2024; 15:e28. [PMID: 39188935 PMCID: PMC11345800 DOI: 10.34172/jlms.2024.28] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 05/19/2024] [Indexed: 08/28/2024]
Abstract
Introduction: The most common causes of fiber post-failure are inadequate restorations and dislodgement. This study aimed to evaluate fiber post-bond strength to dentin following Er,Cr:YSGG laser irradiation. Methods: A total of 65 human mandibular premolars with single roots were included. The 14 mm root length was instrumented with the rotary system using the crown-down technique. Gutta-percha was used for obturation, followed by conventional post space preparation. The samples were divided into two major groups: control (A) and Er,Cr:YSGG (2780 nm) laser group (B). The laser group was subdivided into (B1) 1.25 W, (B2) 1.5 W, and (B3) 1.75 W. All laser groups were set at 20 Hz, 10% and 30% water/air ratio. Fiber posts were cemented with selfadhesive cement. Each sample was divided horizontally into two slices, coronal and apical. The universal testing equipment was used to conduct a push-out test. All groups were examined by SEM and temperature changes. The statistical analysis was performed by using one-way ANOVA and Tukey HSD tests. Results: SEM images of all laser groups revealed the elimination of the smear layer and opened dentinal tubules, which was particularly noticeable in the apical region with no thermal risk to the periodontal tissue. In the push-out test, all laser groups had highly significant (P<0.001) increases in the bond strength of fiber post to dentin. The failure mode of the control group was a predominantly adhesive failure, whereas the laser groups were a predominantly mixed type. Conclusion: The three laser protocols can be used safely in the surface treatment of the fiber post space of endodontically treated teeth. Laser help to increase the bond strength of fiber post to dentin, especially in the apical area.
Collapse
|
3
|
AlAali KA, AlHelal A, Almahri JR, Albakri AA, Albani RM, Alhaizan YA, Alhamdan MM, Alaql NA, Binhasan M, Alhamdan EM, Albaqawi AH, Vohra F, Abduljabbar T. Influence of Conventional Polymer, Hybrid Polymer and Zinc Phosphate Luting Agents on the Bond Strength of Customized Zirconia Post in Premolars-An In-Vitro Evaluation. Polymers (Basel) 2022; 14:polym14040758. [PMID: 35215671 PMCID: PMC8879678 DOI: 10.3390/polym14040758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 02/02/2022] [Accepted: 02/04/2022] [Indexed: 02/01/2023] Open
Abstract
The aim was to identify the influence of conventional polymeric resin based cement (RC), hybrid polymer modified glass ionomer (RMGIC) and Zinc phosphate cement (ZPC) on the pull out strength of the customized zirconia post in premolars. Access cavity and root canals were performed in sixty premolar teeth with the standardized crown down technique (ProTaper Universal, Dentsply). Post space impressions were scanned, and the pre-sintered Zenostar Zr Translucent blanks (Weiland Dental, Pforzheim) were milled with the Opera-system to form the post. All prepared specimens were divided equally in three groups based on the cement type employed for luting as follows: group A: ZPC; group B (GC Fuji PLUS Capsule): RMGIC; group C (and RC (3M RelyX ARC). Ten specimens in each group were thermocycled (TC) at 5 and 55 °C in distilled water baths (40,000 cycles). Pull out bond strength was assessed using a universal testing machine at 0.5 mm/min. The means and standard deviations were compared using ANOVA and Tukey Kramer multiple comparisons tests. A significant difference among the cement groups as well as between TC and non-thermocycled (NTC) groups (p < 0.05) was observed. The highest tensile stress was demonstrated among group C (Resin, 69.89 ± 4.81 (NTC), 64.06 ± 4.36 (TC)) with the least in group A, (zinc phosphate, 43.66 ± 5.02 (NTC), 37.70 ± 5.10 (TC)) for both groups. Group A presented with 100% adhesive bond failures, followed by 80% in group C and 70% in group B, respectively. A similar outcome was observed in the TC group for the cement; however, unlike the NTC group, the TC group showed more cohesive failures compared to the NTC mixed failure. Dual cure polymer based cement demonstrated higher bond strength and efficient adhesive bonding of the customized Zr post with root dentine compared to zinc phosphate (non-polymeric) and RMGIC (hybrid polymer). Thermocycling compromised Zr post adhesive bonding to root dentin.
Collapse
Affiliation(s)
- Khulud A. AlAali
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh 11671, Saudi Arabia
- Correspondence: (K.A.A.); (T.A.)
| | - Abdulaziz AlHelal
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.A.); (M.M.A.); (E.M.A.); (F.V.)
| | - Jawaher R. Almahri
- Prosthodontics Postgraduate Resident, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh 11671, Saudi Arabia;
| | - Aroob A. Albakri
- General Dentist, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh 11671, Saudi Arabia;
| | - Ragad M. Albani
- Prosthodontics Postgraduate Resident, College of Dentistry, King Saud University, Riyadh 11671, Saudi Arabia;
| | - Yasmeen A. Alhaizan
- Restorative Postgraduate Resident, King Faisal Specialist Hospital, Riyadh 11211, Saudi Arabia;
| | - Mai M. Alhamdan
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.A.); (M.M.A.); (E.M.A.); (F.V.)
| | - Naif A. Alaql
- Prosthodontic Department, Riyadh Specialized Dental Center, Ministry of Health, Riyadh 13226, Saudi Arabia;
| | - Mashael Binhasan
- Department of Restorative Dentistry, Division of Operative Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
| | - Eman M. Alhamdan
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.A.); (M.M.A.); (E.M.A.); (F.V.)
| | - Ahmed H. Albaqawi
- Department of Restorative Dental Science, College of Dentistry, University of Ha’il, Ha’il 55476, Saudi Arabia;
| | - Fahim Vohra
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.A.); (M.M.A.); (E.M.A.); (F.V.)
| | - Tariq Abduljabbar
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.A.); (M.M.A.); (E.M.A.); (F.V.)
- Correspondence: (K.A.A.); (T.A.)
| |
Collapse
|
4
|
Influence of Different Conditioning Treatments on the Bond Integrity of Root Dentin to rGO Infiltrated Dentin Adhesive. SEM, EDX, FTIR and MicroRaman Study. Polymers (Basel) 2021; 13:polym13101555. [PMID: 34066202 PMCID: PMC8150839 DOI: 10.3390/polym13101555] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 05/06/2021] [Accepted: 05/06/2021] [Indexed: 12/22/2022] Open
Abstract
The present study aimed to synthesize and equate the mechanical properties and dentin interaction of two adhesives; experimental adhesive (EA) and 5 wt.% reduced graphene oxide rGO) containing adhesive. Scanning electron microscopy (SEM)-Energy-dispersive X-ray spectroscopy (EDX), Micro-Raman spectroscopy, push-out bond strength test, and Fourier Transform Infrared (FTIR) spectroscopy were employed to study nano-bond strength, degree of conversion (DC), and adhesive-dentin interaction. The EA was prepared, and rGO particles were added to produce two adhesive groups, EA-rGO-0% (control) and rGO-5%. The canals of sixty roots were shaped and prepared, and fiber posts were cemented. The specimens were further alienated into groups based on the root canal disinfection technique, including 2.5% sodium hypochlorite (NaOCl), Photodynamic therapy (PDT), and ER-CR-YSGG laser (ECYL). The rGO nanoparticles were flake-shaped, and EDX confirmed the presence of carbon (C). Micro-Raman spectroscopy revealed distinct peaks for graphene. Push-out bond strength test demonstrated highest values for the EA-rGO-0% group after NaOCl and PDT conditioning whereas, rGO-5% showed higher values after ECYL conditioning. EA-rGO-0% presented greater DC than rGO-5% adhesive. The rGO-5% adhesive demonstrated comparable push-out bond strength and rheological properties to the controls. The rGO-5% demonstrated acceptable DC (although lower than control group), appropriate dentin interaction, and resin tag establishment.
Collapse
|
5
|
Effect of Nd:YAG, Er,Cr:YSGG Laser Irradiation, and Adjunctive Photodynamic Therapy on Push-Out Bond Strength of Zirconia Posts to Radicular Dentin. BIOMED RESEARCH INTERNATIONAL 2021; 2021:5523242. [PMID: 34036099 PMCID: PMC8118734 DOI: 10.1155/2021/5523242] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 04/20/2021] [Accepted: 04/30/2021] [Indexed: 11/17/2022]
Abstract
This study is aimed at assessing the influence of Nd:YAG, Er,Cr:YSGG laser irradiation, and adjunctive photodynamic therapy (aPDT) on the bond strength of zirconia posts to radicular dentin. Eighty extracted anterior teeth were randomly categorized into 4 groups (n = 20) based on varying laser irradiation treatments, i.e., conventional cleaning and shaping (CCS), Nd:YAG, Er,Cr:YSGG, and aPDT group, respectively. Using a cutting machine, the samples were prepared for push-out bond strength analysis; 4 sections (2 on each apical and cervical) of around 1 mm thickness were sectioned for all roots at a right angle to the long axis of the post. After making the space for the post, they were incorporated into the root system and were subjected to different laser treatments. The universal testing machine was utilized to assess the push-out bond strength, which had a defined 1 mm/minute crosshead speed until the failure was encountered. Specimens in the aPDT group (8.20 ± 2.14 MPa) demonstrated the highest mean push-out bond strength, whereas the lowest was shown by samples in the CCS group (7.08 ± 1.11 MPa). According to the independent t-test, the mean push-out bond strength scores of the cervical segments were higher as compared to the apical segments in research groups (p < 0.05). Overall, the adhesive type was the most frequently encountered failure mode in all of the experimental groups, with the least number of failures observed in aPDT treated teeth samples. In conclusion, the push-out bond strength to radicular dentin was not much influenced by Nd:YAG, Er,Cr:YSGG laser, and aPDT in comparison with CCS. Although statistically not significant, however, the application of aPDT provided better outcomes as compared to other research groups.
Collapse
|
6
|
Vohra F, Shuwaish MB, Deeb MA, Alhamdan R, Alotaibi N, Abduljabbar T. Comparison of failure loads and compressive stress in Press on metal and Press on Y-TZP copings. Pak J Med Sci 2020; 36:1645-1650. [PMID: 33235590 PMCID: PMC7674887 DOI: 10.12669/pjms.36.7.2472] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Objective: The aim of the study was to assess the failure loads and compressive stresses among bilayered press on Y-TZP (POZ) and press on metal (POM) crowns with different core-veneer thickness. Methods: Thirty metal and Y-TZP copings were fabricated using CAD-CAM technology with specified thickness. All copings were veneered with ceramic materials using hot pressing technique, with 2mm and 2.5mm thickness. The different coping veneer thickness of crowns resulted in six study groups, including, POM: Coping/ veneer thickness of 0.7/2mm (Gp1), 0.7/2.5mm (Gp 2) and 1mm/2mm (Gp 3)-POZ: 0.7/2mm (Gp A), 0.7/2.5mm (Gp B) and 1mm/2mm (Gp C). Crowns were cemented to a standard implant analog and failure loads (FL) and compressive stress (CS) was ascertained by controlled load application in a universal testing machine. Data was analysed using ANOVA and multiple comparisons test. Results: The maximum FL were observed in the POM specimens with a C/V ratio of 1/2 (Group 3-1880.67± 256.78 N), however the lowest FL were exhibited by POZ crowns with 1/2 C/V ratio (Group C-611.89± 72.79 N). Mean FL and CS were significantly higher in POM compared to POZ crowns in respective groups. Increasing the coping-veneer thickness increased FL and CS among POM crowns. Increasing veneer and decreasing coping thickness improved FL and CS among POZ crowns. Conclusions: Press on metal specimen showed higher resistance to fracture than Press on Y-TZP specimens. Improved failure loads were observed in thin coping and thick veneers among Press on Y-TZP crowns.
Collapse
Affiliation(s)
- Fahim Vohra
- Fahim Vohra, Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Mohammed Bin Shuwaish
- Mohammed Bin Shuwaish, Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Modhi Al Deeb
- Modhi Al Deeb, Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Rana Alhamdan
- Rana Al Hamdan, Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Naif Alotaibi
- Naif Alotaibi, Department of General Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Tariq Abduljabbar
- Tariq Abduljabbar, Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| |
Collapse
|