1
|
Giakoumi M, Stephanou PS, Kokkinidou D, Papastefanou C, Anayiotos A, Kapnisis K. A Predictive Toxicokinetic Model for Nickel Leaching from Vascular Stents. ACS Biomater Sci Eng 2024; 10:2534-2551. [PMID: 38525821 PMCID: PMC11005016 DOI: 10.1021/acsbiomaterials.3c01436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 03/06/2024] [Accepted: 03/06/2024] [Indexed: 03/26/2024]
Abstract
In vitro testing methods offer valuable insights into the corrosion vulnerability of metal implants and enable prompt comparison between devices. However, they fall short in predicting the extent of leaching and the biodistribution of implant byproducts under in vivo conditions. Physiologically based toxicokinetic (PBTK) models are capable of quantitatively establishing such correlations and therefore provide a powerful tool in advancing nonclinical methods to test medical implants and assess patient exposure to implant debris. In this study, we present a multicompartment PBTK model and a simulation engine for toxicological risk assessment of vascular stents. The mathematical model consists of a detailed set of constitutive equations that describe the transfer of nickel ions from the device to peri-implant tissue and circulation and the nickel mass exchange between blood and the various tissues/organs and excreta. Model parameterization was performed using (1) in-house-produced data from immersion testing to compute the device-specific diffusion parameters and (2) full-scale animal in situ implantation studies to extract the mammalian-specific biokinetic functions that characterize the time-dependent biodistribution of the released ions. The PBTK model was put to the test using a simulation engine to estimate the concentration-time profiles, along with confidence intervals through probabilistic Monte Carlo, of nickel ions leaching from the implanted devices and determine if permissible exposure limits are exceeded. The model-derived output demonstrated prognostic conformity with reported experimental data, indicating that it may provide the basis for the broader use of modeling and simulation tools to guide the optimal design of implantable devices in compliance with exposure limits and other regulatory requirements.
Collapse
Affiliation(s)
- Matheos Giakoumi
- Department
of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
| | - Pavlos S. Stephanou
- Department
of Chemical Engineering, Cyprus University
of Technology, Limassol 3036, Cyprus
| | - Despoina Kokkinidou
- Department
of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
| | | | - Andreas Anayiotos
- Department
of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
| | - Konstantinos Kapnisis
- Department
of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3036, Cyprus
| |
Collapse
|
2
|
Moisa SM, Burlacu A, Butnariu LI, Vasile CM, Brinza C, Spoiala EL, Maștaleru A, Leon MM, Rosu ST, Vatasescu R, Cinteză EE. Nanotechnology Innovations in Pediatric Cardiology and Cardiovascular Medicine: A Comprehensive Review. Biomedicines 2024; 12:185. [PMID: 38255290 PMCID: PMC10813221 DOI: 10.3390/biomedicines12010185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 01/09/2024] [Accepted: 01/13/2024] [Indexed: 01/24/2024] Open
Abstract
(1) Background: Nanomedicine, incorporating various nanoparticles and nanomaterials, offers significant potential in medical practice. Its clinical adoption, however, faces challenges like safety concerns, regulatory hurdles, and biocompatibility issues. Despite these, recent advancements have led to the approval of many nanotechnology-based products, including those for pediatric use. (2) Methods: Our approach included reviewing clinical, preclinical, and animal studies, as well as literature reviews from the past two decades and ongoing trials. (3) Results: Nanotechnology has introduced innovative solutions in cardiovascular care, particularly in managing myocardial ischemia. Key developments include drug-eluting stents, nitric oxide-releasing coatings, and the use of magnetic nanoparticles in cardiomyocyte transplantation. These advancements are pivotal for early detection and treatment. In cardiovascular imaging, nanotechnology enables noninvasive assessments. In pediatric cardiology, it holds promise in assisting the development of biological conduits, synthetic valves, and bioartificial grafts for congenital heart defects, and offers new treatments for conditions like dilated cardiomyopathy and pulmonary hypertension. (4) Conclusions: Nanomedicine presents groundbreaking solutions for cardiovascular diseases in both adults and children. It has the potential to transform cardiac care, from enhancing myocardial ischemia treatment and imaging techniques to addressing congenital heart issues. Further research and guideline development are crucial for optimizing its clinical application and revolutionizing patient care.
Collapse
Affiliation(s)
- Stefana Maria Moisa
- Department of Pediatrics, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania (E.L.S.)
- “Sfanta Maria” Clinical Emergency Hospital for Children, 700309 Iasi, Romania (S.T.R.)
| | - Alexandru Burlacu
- Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
- Institute of Cardiovascular Diseases “Prof. Dr. George I.M. Georgescu”, 700503 Iasi, Romania
| | - Lacramioara Ionela Butnariu
- “Sfanta Maria” Clinical Emergency Hospital for Children, 700309 Iasi, Romania (S.T.R.)
- Department of Medical Genetics, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Corina Maria Vasile
- Pediatric and Adult Congenital Cardiology Department, Centre Hospitalier Universitaire de Bordeaux, 33000 Bordeaux, France;
| | - Crischentian Brinza
- Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
- Institute of Cardiovascular Diseases “Prof. Dr. George I.M. Georgescu”, 700503 Iasi, Romania
| | - Elena Lia Spoiala
- Department of Pediatrics, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania (E.L.S.)
| | - Alexandra Maștaleru
- Department of Medical Specialties I, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.M.)
- Clinical Rehabilitation Hospital, 700661 Iasi, Romania
| | - Maria Magdalena Leon
- Department of Medical Specialties I, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (A.M.)
- Clinical Rehabilitation Hospital, 700661 Iasi, Romania
| | - Solange Tamara Rosu
- “Sfanta Maria” Clinical Emergency Hospital for Children, 700309 Iasi, Romania (S.T.R.)
- Department of Nursing, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Radu Vatasescu
- Cardio-Thoracic Department, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania
- Clinical Emergency Hospital, 050098 Bucharest, Romania
| | - Eliza Elena Cinteză
- Department of Pediatrics, “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania;
- Department of Pediatric Cardiology, “Marie Curie” Emergency Children’s Hospital, 041451 Bucharest, Romania
| |
Collapse
|
3
|
Tjen VH, Yang PZ. Nickel-related hypersensitivity reactions following endovascular interventions: A review of current evidence. Sci Prog 2023; 106:368504231200626. [PMID: 37872684 PMCID: PMC10594965 DOI: 10.1177/00368504231200626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
INTRODUCTION Nickel is a principal alloying agent in the production of vascular endoprostheses, despite persisting as the most habitually identified allergen. Variable nickel-related hypersensitivity manifestations following endovascular intervention were reported, challenging established paradigms in treatment and accuracy of prognostic assessments. The objective of this review is to critically evaluate current metrics to maximise patient-related outcomes. METHODS A literature review was conducted in compliance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2009 statement. Patients indicative of nickel hypersensitivity reaction following endovascular intervention were discerned. A positive reaction was defined by patch testing, histological analysis, or anamnesis indicative of nickel hypersensitivity. Morphology of implicating prostheses, adverse events and postoperative complications, clinical course, diagnostic and therapeutic strategies alongside patient prognosis were recorded. RESULTS Nickel-related hypersensitivity reactions following endovascular repair were identified in 36 patients with a median age of 44.5 years. 20 patients received nitinol-containing intervention. 28 (77.8%) patients are female. Multi-organ adverse reactions occurred in 21 (58.3%) patients with variable latency. 14 (38.9%) patients were presented with neurological adverse reactions manifesting mainly as unilateral hemiparesis. Dermatological reactions implicated 16 (44.4%) patients. Miscellaneous manifestations include suicidal ideation. 13 (36.1%) patients displayed previous metal intolerance and 32 (88.9%) patients had positive patch testing for nickel. Histological analysis of lesions and prostheses indicated lymphocytic infiltration. 5 (13.9%) patients experienced device-specific reactions as in-stent restenosis or auxiliary distal vessel stenosis. 11 (30.1%) patients received solely medical therapy and 5 (13.9%) patients received solely surgical therapy. 19 (52.7%) patients underwent both medical (oral corticosteroid) and surgical therapy (device retrieval). 26 (77.1%) patients achieved symptomatic cessation, 6 (16.7%) patients exhibited symptomatic persistence and 0 patients died. CONCLUSION Prophylactic pre-assessment for a history of metal allergy and consideration of prostheses alternatives is recommended to minimise reaction risk and severity. Despite nickel's predominant usage, information paucity urges additional studies to emphasise its implications and maximise patient outcomes.
Collapse
Affiliation(s)
| | - Paul Zichu Yang
- School of Medicine, University of Glasgow, Glasgow, UK
- Department of Vascular Surgery, Queen Elizabeth University Hospital, Glasgow, UK
| |
Collapse
|
4
|
Roodenburg SA, Pouwels SD, Klooster K, Touw DJ, Slebos DJ. Endobronchial Valve Treatment Does Not Cause Significant Nickel Deposition in Lung Tissue. Respiration 2023; 102:454-457. [PMID: 37231891 DOI: 10.1159/000529889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 02/21/2023] [Indexed: 05/27/2023] Open
Abstract
Bronchoscopic lung volume reduction using endobronchial valves (EBVs) is a treatment option for patients with severe emphysema. These EBVs are made out of a nitinol mesh covered by a silicone layer. Nitinol is an alloy of nickel and titanium and is commonly used in implantable medical devices because of its biocompatibility and memory-shape properties. However, there are some concerns that nickel ions can be released from nitinol-containing devices which might cause adverse health effects, especially in patients with a known nickel hypersensitivity. In vitro, it was found that EBV release significant amounts of nickel in the first hours. Our aim was to assess the nickel concentration in lung tissue from a patient who previously underwent EBV treatment but, due to treatment failure, underwent lung volume reduction surgery and to compare this to a reference sample. We found no significant difference in the median nickel concentration between the EBV-treated patient and the non-EBV-treated patient (0.270 vs. 0.328 μg/g, respectively, p = 0.693) and these concentrations were also comparable to previously published nickel concentrations in human lung tissue samples not having any medically implanted devices in the lung. Our results suggest that there is no significant long-term nickel deposition in lung tissue after EBV treatment.
Collapse
Affiliation(s)
- Sharyn A Roodenburg
- Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
- Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Simon D Pouwels
- Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
- Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
- Department of Pathology and Medical Biology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Karin Klooster
- Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
- Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Daan J Touw
- Department of Clinical Pharmacy and Pharmacology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Dirk-Jan Slebos
- Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
- Groningen Research Institute for Asthma and COPD, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
5
|
Lin C, Huang Z, Wang Q, Zou Z, Wang W, Liu L, Liu Y, Leng J. 4D Printing of Overall Radiopaque Customized Bionic Occlusion Devices. Adv Healthc Mater 2023; 12:e2201999. [PMID: 36337009 DOI: 10.1002/adhm.202201999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/28/2022] [Indexed: 11/09/2022]
Abstract
Percutaneous closure of ventricular septal defect (VSD) can effectively occlude abnormal blood flow between ventricles. However, commonly used Nitinol occlusion devices have non-negligible limitations, such as nondegradability leading to life-threatening embolization; limited device size predisposing to displacement and wear; only a few radiopaque markers resulting in inaccurate positioning. Nevertheless, the exploration of customized, biodegradable, and overall radiopaque occluders is still vacant. Here, overall radiopaque, biodegradable, and dynamic reconfigurable 4D printed VSD occluders are developed. Based on wavy bionic structures, various VSD occluders are designed and manufactured to adapt to the position diversity of VSD. The customized configuration, biocompatibility, and biodegradability of the developed 4D printed bionic occluders can eliminate the series of complications caused by traditional occluders. The overall radiopacity of 4D printed VSD occluders is validated ex vivo and in vivo, whereby accurate positioning can be assured. Notably, the preparation strategies for 4D printed occluders are scalable, eliminating the barriers to mass production, and marking a meaningful step in bridging the gap between modeling and clinical application of 4D printed occlusion devices. This work opens attractive perspectives for the rapid manufacturing of customized intelligent medical devices for which overall radiopacity, dynamic reconfigurability, biocompatibility, and biodegradability are sought.
Collapse
Affiliation(s)
- Cheng Lin
- Centre for Composite Materials and Structures, Harbin Institute of Technology, No. 2 Yikuang Street, Harbin, 150001, P. R. China
| | - Zhipeng Huang
- Tangdu Hospital of the Air Force Military Medical University, No. 1, Xinsi Road, Xi'an, 710038, P. R. China
| | - Qinglong Wang
- Tangdu Hospital of the Air Force Military Medical University, No. 1, Xinsi Road, Xi'an, 710038, P. R. China
| | - Zhichen Zou
- The First Affiliated Hospital of Harbin Medical University, No. 23 Youzheng Street, Nangang District, Harbin, 150001, P. R. China
| | - Wenbo Wang
- The First Affiliated Hospital of Harbin Medical University, No. 23 Youzheng Street, Nangang District, Harbin, 150001, P. R. China
| | - Liwu Liu
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology, No. 92 West Dazhi Street, Harbin, 150001, P. R. China
| | - Yanju Liu
- Department of Astronautical Science and Mechanics, Harbin Institute of Technology, No. 92 West Dazhi Street, Harbin, 150001, P. R. China
| | - Jinsong Leng
- Centre for Composite Materials and Structures, Harbin Institute of Technology, No. 2 Yikuang Street, Harbin, 150001, P. R. China
| |
Collapse
|
6
|
Efficacy and safety of a parylene-coated occluder for atrial septal defect: a prospective, multi-center, randomized controlled clinical trial. Chin Med J (Engl) 2021; 134:2685-2691. [PMID: 34759229 PMCID: PMC8631379 DOI: 10.1097/cm9.0000000000001865] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Background: Nitinol-containing devices are widely used in clinical practice. However, there are concerns about nickel release after nitinol-containing device implantation. This study aimed to compare the efficacy and safety of a parylene-coated occluder vs. a traditional nitinol-containing device for atrial septal defect (ASD). Methods: One-hundred-and-eight patients with ASD were prospectively enrolled and randomly assigned to either the trial group to receive a parylene-coated occluder (n = 54) or the control group to receive a traditional occluder (n = 54). The plugging success rate at 6 months after device implantation and the pre- and post-implantation serum nickel levels were compared between the two groups. A non-inferiority design was used to prove that the therapeutic effect of the parylene-coated device was non-inferior to that of the traditional device. The Cochran–Mantel–Haenszel chi-squared test with adjustment for central effects was used for the comparison between groups. Results: At 6 months after implantation, successful ASD closure was achieved in 52 of 53 patients (98.11%) in both the trial and control groups (95% confidence interval (CI): [−4.90, 5.16]) based on per-protocol set analysis. The absolute value of the lower limit of the 95% CI was 4.90%, which was less than the specified non-inferiority margin of 8%. No deaths or severe complications occurred during 6 months of follow-up. The serum nickel levels were significantly increased at 2 weeks and reached the maximum value at 1 month after implantation in the control group (P < 0.05 vs. baseline). In the trial group, there was no significant difference in the serum nickel level before vs. after device implantation (P > 0.05). Conclusions: The efficacy of a parylene-coated ASD occluder is non-inferior to that of a traditional uncoated ASD occluder. The parylene-coated occluder prevents nickel release after device implantation and may be an alternative for ASD, especially in patients with a nickel allergy.
Collapse
|
7
|
Nickel Hypersensitivity to Atrial Septal Occluders: Smoke Without Fire? Clin Rev Allergy Immunol 2021; 62:476-483. [PMID: 34129170 DOI: 10.1007/s12016-021-08867-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/31/2021] [Indexed: 02/08/2023]
Abstract
Nickel is one of the most common contact allergens worldwide; it is used as the main component of the devices used for atrial septal defects (ASDs) and patent foramen ovale (PFO) closure. Developing nickel hypersensitivity after PFO/ASD occlusion is significantly rarer described in medical literature than typical nickel contact sensitization. The exact pathophysiological mechanism of this "device syndrome" remains unknown, and many question the real incidence or even the existence of this clinical entity. Nevertheless, it has been associated with a wide spectrum of symptoms, including chest pain, migraines, palpitation, and dyspnea. Skin patch tests are the first-line approach to diagnose nickel hypersensitivity. However, diagnostic criteria for the device syndrome have not been developed, and diagnosis in reported cases is established by a process of elimination. Management-drug therapy (corticosteroids, clopidogrel, etc.) or even surgical explantation in severe cases-of patients developing such clinical manifestations after percutaneous PFO/ASD occlusion is empirical. Undoubtedly, endocardiac device-related nickel hypersensitivity requires more focused research to discover the underlying mechanism as well as to develop reliable prognostic tests for detecting high-risk patients and preventing severe nickel hypersensitivity reactions.
Collapse
|
8
|
Thanopoulos BVD, Soendergaard L, Ngugen HL, Marasini M, Giannopoulos A, Bompotis GC, Thonghong T, Krishnamoorthy KM, Placid S, Deleanou D, Toutouzas KP. International experience with the use of Cocoon septal occluder for closure of atrial septal defects. Hellenic J Cardiol 2021; 62:206-211. [PMID: 33484876 DOI: 10.1016/j.hjc.2020.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 12/14/2020] [Accepted: 12/17/2020] [Indexed: 10/22/2022] Open
Abstract
BACKGROUND The Cocoon septal occluder (CSO) is a new generation double disk occluder device for catheter closure of the secundum atrial septal defect (ASD). Initial clinical evaluations with the use of this device have shown quite satisfactory results but large follow-up studies are missing. In this international multicenter study, we present procedural and follow-up data from 4008 patients with secundum ASD who underwent catheter closure with the use of CSO. METHODS The study cohort consisted of 1853 pediatric and 2155 adult patients with secundum ASD treated with the CSO. Patients were enrolled retrospectively from 11 international centers and were followed for a mean period of 43 months (range 12-84 months), postprocedural. Clinical, electrocardiographic, echocardiographic, procedural, and follow-up data were collected from each collaborating hospital. RESULTS The CSO was permanently implanted in 3983 patients (99.4%). Echocardiographic evaluation at one month follow-up revealed complete closure in 99.6% of those patients who had a device implanted. Thrombus formation in one adult patient was the only major device related to procedural complication. During the follow-up period, no patient developed cardiac erosions, allergic reactions to nickel, or other major complications. CONCLUSIONS Implantation of CSO provided satisfactory procedural and follow-up results with high success and no device-related cardiac erosions and nickel allergy.
Collapse
Affiliation(s)
| | - Lars Soendergaard
- Department of Cardiology Copenhagen University Hospital, Rigshospitalet, Denmark
| | | | | | - Andreas Giannopoulos
- Department of Pediatric Cardiology AHEPA University General Hospital of Thessaloniki, Greece
| | - Georgios C Bompotis
- Department of Cardiology Papageorgiou General Hospital of Thessaloniki, Greece
| | - Tasalac Thonghong
- Department of Cardiology Chiang Mai University Hospital, Chiang Mai, Thailand
| | | | - Sebastian Placid
- Department of Cardiology Sakaharna Hrudayalaya Hospital, Kerala, India
| | - Dan Deleanou
- Institute for Cardiovascular Diseases C.C. Iliescu, Bucharest, Romania
| | - Konstantinos P Toutouzas
- First Department of Cardiology Hippokration General Hospital, National and Kapodistrian University of Athens, Greece
| |
Collapse
|