1
|
da Costa Moraes AA, Duarte MB, Ferreira EV, da Silva Almeida GC, da Rocha Santos EG, Pinto GHL, de Oliveira PR, Amorim CF, Cabral ADS, de Athayde Costa e Silva A, Souza GS, Callegari B. Validity and Reliability of Smartphone App for Evaluating Postural Adjustments during Step Initiation. SENSORS (BASEL, SWITZERLAND) 2022; 22:2935. [PMID: 35458920 PMCID: PMC9030467 DOI: 10.3390/s22082935] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 02/17/2022] [Accepted: 03/03/2022] [Indexed: 06/14/2023]
Abstract
The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland−Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.
Collapse
Affiliation(s)
- Anderson Antunes da Costa Moraes
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Manuela Brito Duarte
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Eduardo Veloso Ferreira
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Gizele Cristina da Silva Almeida
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| | - Enzo Gabriel da Rocha Santos
- Institute of Exact and Natural Sciences, Federal University of Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| | - Gustavo Henrique Lima Pinto
- Institute of Exact and Natural Sciences, Federal University of Pará, R. Augusto Corrêa, 01, Belém 66093-020, PA, Brazil; (E.G.d.R.S.); (G.H.L.P.)
| | - Paulo Rui de Oliveira
- Doctoral and Master’s Program in Physical Therapy, UNICID, 448/475 Cesário Galeno St., São Paulo 03071-000, SP, Brazil; (P.R.d.O.); (C.F.A.)
| | - César Ferreira Amorim
- Doctoral and Master’s Program in Physical Therapy, UNICID, 448/475 Cesário Galeno St., São Paulo 03071-000, SP, Brazil; (P.R.d.O.); (C.F.A.)
- Département des Sciences de la Santé, Programme de Physiothérapie de L’université McGill Offert en Extension à l’UQAC, Saguenay, QC G7H 2B1,Canada
- Physical Therapy and Neuroscience Departments, Wertheims’ Colleges of Nursing and Health Sciences and Medicine, Florida International University (FIU), Miami, FL 33199, USA
| | - André dos Santos Cabral
- Center for Biological and Health Sciences, Pará State University, Tv. Perebebuí, 2623—Marco, Belém 66087-662, PA, Brazil;
| | - Anselmo de Athayde Costa e Silva
- Postgraduate Program in Movement Science, Federal University of Pará, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil;
| | - Givago Silva Souza
- Institute of Biological Sciences, Federal University of Pará, R. Augusto Corrêa 01, Belém 66075-110, PA, Brazil;
- Tropical Medicine Nucleus, Federal University of Pará, Avenida Generalíssimo Deodoro 92, Belém 66055-240, PA, Brazil
| | - Bianca Callegari
- Human Motricity Studies Laboratory, Av. Generalíssimo Deodoro 01, Belém 66073-000, PA, Brazil; (A.A.d.C.M.); (M.B.D.); (E.V.F.); (G.C.d.S.A.)
| |
Collapse
|
2
|
Lee DH, Han S. Reliability of Measuring Leg Segments and Joint Angles Using Smartphones during Aquatic Exercise. Healthc Inform Res 2022; 28:95-101. [PMID: 35172095 PMCID: PMC8850177 DOI: 10.4258/hir.2022.28.1.95] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Accepted: 09/24/2021] [Indexed: 11/23/2022] Open
Abstract
Objectives: Aquatic therapy is a significant intervention method for both patients and healthy individuals. However, in clinical practice, quantitative measurements are rarely applied in aquatic therapy due to the disadvantages of submerging expensive instruments in water. In this study, we used readily available smartphones and armbands to measure leg segments and joint angles during aquatic gait and evaluated the reliability of these measurements.Methods: Waterproof smartphones were strapped to the trunk, thighs, and shanks of 19 healthy young adults using armbands. The angles of the trunk, thigh, and shank segments were measured during aquatic gait. The measurements were repeated 1 day later. The data were analyzed to obtain the angles of the hip and knee joints.Results: Measurement repeatability, calculated using the intraclass correlation coefficient (ICC), was the highest for the shank segment range of motion (ROM) (first 46.79° ± 5.50°, second 50.12° ± 9.98°, ICC = 0.78). There was high agreement in trunk segment ROM (first 6.36° ± 1.42°, second 4.29° ± 1.83°, ICC = 0.73), thigh segment ROM (first 33.49° ± 5.18°, second 37.31° ± 8.70°, ICC = 0.62), and knee joint ROM (first 52.43° ± 11.26°, second 62.19° ± 16.65°, ICC = 0.68) and fair agreement in hip joint ROM (first 34.60°±4.71°, second 37.80° ± 7.84°, ICC = 0.59).Conclusions: Smartphones can be used to reliably measure leg segments and joint angles during aquatic gait, providing a simpler method for obtaining these measurements and enabling the wider use of aquatic motion analysis in clinical practice and research.
Collapse
Affiliation(s)
- Dae Hee Lee
- Department of Physical Therapy, U1 University, Yeongdong-gun, Chungbuk, Korea
| | - Seulki Han
- Department of Physical Therapy, Daejeon Health Institute of Technology, Daejeon, Korea
| |
Collapse
|
3
|
Wodarski P, Jurkojć J, Gzik M. Wavelet Decomposition in Analysis of Impact of Virtual Reality Head Mounted Display Systems on Postural Stability. SENSORS 2020; 20:s20247138. [PMID: 33322821 PMCID: PMC7764736 DOI: 10.3390/s20247138] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/10/2020] [Accepted: 12/10/2020] [Indexed: 11/16/2022]
Abstract
This study investigated how spatial projection systems influences body balance including postural stability. Analyzing precisely defined frequency bands of movements of the center of pressure makes it possible to determine the effectiveness of the balance system’s response to disruptions and disorders and may be used as an indicator in the diagnosis of motor dysfunction. The study involved 28 participants for whom the center of pressure was assessed in a test with open eyes, closed eyes and with virtual reality projection. Percent distributions of energy during wavelet decomposition were calculated. Changes in body stability were determined for the virtual reality tests and these changes were classified as an intermediate value between the open-eyes test and the closed-eyes test. The results indicate the importance of using safety support systems in therapies involving Virtual Reality. The results also show the necessity of measurements times in stabilographic evaluations in order to conduct a more thorough analysis of very low frequencies of the center of pressure signal.
Collapse
|
4
|
Validity of Measurement for Trailing Limb Angle and Propulsion Force during Gait Using a Magnetic Inertial Measurement Unit. BIOMED RESEARCH INTERNATIONAL 2020; 2019:8123467. [PMID: 31930138 PMCID: PMC6942796 DOI: 10.1155/2019/8123467] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 07/18/2019] [Accepted: 08/23/2019] [Indexed: 11/18/2022]
Abstract
Propulsion force and trailing limb angle (TLA) are meaningful indicators for evaluating quality of gait. This study examined the validity of measurement for TLA and propulsion force during various gait conditions using magnetic inertial measurement units (IMU), based on measurements using a three-dimensional motion analysis system and a force platform. Eighteen healthy males (mean age 25.2 ± 3.2 years, body height 1.70 ± 0.06 m) walked with and without trunk fluctuation at preferred, slow, and fast velocities. IMU were fixed on the thorax, lumbar spine, and right thigh and shank. IMU calculated the acceleration and tilt angles in a global coordinate system. TLA, consisting of a line connecting the hip joint with the ankle joint, and the laboratory's vertical axis at late stance in the sagittal plane, was calculated from thigh and shank segment angles obtained by IMU, and coordinate data from the motion analysis system. Propulsion force was estimated by the increment of velocity calculated from anterior acceleration measured by IMU fixed on the thorax and lumbar spine, and normalized impulse of the anterior component of ground reaction force (AGRF) during late stance. Similarity of TLA measured by IMU and the motion analysis system was tested by the coefficient of multiple correlation (CMC), intraclass correlation coefficient (ICC), and root mean square (RMS) of measurement error. Relationships between normalized impulse of AGRF and increments of velocity, as measured by IMU, were tested using correlation analysis. CMC of TLA was 0.956–0.959. ICC between peak TLAs was 0.831–0.876 (p < 0.001), and RMS of error was 1.42°–1.92°. Velocity increment calculated from acceleration on the lumbar region showed strong correlations with normalized impulse of AGRF (r = 0.755–0.892, p < 0.001). These results indicated a high validity of estimation of TLA and propulsion force by IMU during various gait conditions; these methods would be useful for best clinical practice.
Collapse
|