1
|
Dong Y, Zhang Q, Chen H, Jin Y, Ji Z, Han H, Wang W. Radiomics of Multi-modality Ultrasound in Rabbit VX2 Liver Tumors: Differentiating Residual Tumors from Hyperemic Rim After Ablation. J Med Biol Eng 2022. [DOI: 10.1007/s40846-022-00763-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
2
|
Zhang W, Yi H, Cai B, He Y, Huang S, Zhang Y. Feasibility of contrast-enhanced ultrasonography (CEUS) in evaluating renal microvascular perfusion in pediatric patients. BMC Med Imaging 2022; 22:194. [PMID: 36357841 PMCID: PMC9650893 DOI: 10.1186/s12880-022-00925-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 11/01/2022] [Indexed: 11/12/2022] Open
Abstract
Background Changes in renal microvascular perfusion are involved in several kidney diseases. Contrast-enhanced ultrasonography (CEUS) quantitative analysis can enable the estimation of renal microvascular perfusion non-invasively. However, to date, few pediatric patients with renal disease have been subjected to CEUS quantitative analysis. This study aimed to explore the feasibility of CEUS in evaluating renal microvascular perfusion in pediatric patients and paving its way to clinical practice. Methods Seventeen pediatric patients with chronic kidney disease (CKD) and five children without kidney disease were consecutively examined using CEUS. Quantitative analysis of CEUS images based on time-intensity curve (TIC) fittings was performed using specialized software. Quantitative parameters of wash-in microvascular blood flow, including A, k, B, and TtoPk, were generated from three regions of interest (ROIs) each in the cortex and medulla of each kidney. Results CEUS was performed in all children successfully and safely without the use of sedatives. All parameters (A, B, k, and TtoPk) demonstrated no statistical differences among the three sampling ROIs in the renal cortex and medulla. All parameters (A, B, k, and TtoPk) showed no statistical differences between the left and right sides of kidneys both in cortices and medullas. Comparing with patients with CKD stage 3–5, both control group and patients with CKD stage 1–2 had significantly higher values of parameter A in the renal cortex (p = 0.025 and p = 0.031, respectively). In control group and patients stage 1–2, the values of parameters k in the renal cortices were significantly higher than that in the renal medullas, while in patients with CKD stage 3–5, parameter k showed no statistically significant differences between the renal cortex and medulla (p = 0.173). Conclusion CEUS is safe and practicable in pediatric patients with chronic kidney disease. Renal microvascular perfusion estimated by CEUS could be a robust approach in the evaluation of pediatric renal diseases. Parameters A and k derived from CEUS quantitative analysis can provide great potential in non-invasive assessment of renal microvascular perfusion impairment in pediatric CKD.
Collapse
|
3
|
Quantitative Analysis of Contrast-Enhanced Ultrasound That Can Be Used to Evaluate Angiogenesis during Patellar Tendon Healing in Rats. CONTRAST MEDIA & MOLECULAR IMAGING 2022; 2022:6867743. [PMID: 36313964 PMCID: PMC9584743 DOI: 10.1155/2022/6867743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Accepted: 09/15/2022] [Indexed: 01/26/2023]
Abstract
Objective To investigate the efficacy of contrast-enhanced ultrasound (CEUS) in quantitatively evaluating angiogenesis during patellar tendon healing in rats. Methods A total of 40 Sprague-Dawley rats were used in this study. The patellar tendons of 30 rats (60 limbs) that underwent incision and suture were treated as the operation group and monitored after 7, 14, and 28 days. The normal patellar tendons of 10 rats (20 limbs) were treated as the control group and monitored on day 0. The ultrasound examination was used to evaluate the structure and blood perfusion of the patellar tendon. Immunohistochemistry was used to assess angiogenesis, and the biomechanical test was used to verify functional recovery of the patellar tendon. Results The tendons in the operation group were significantly thickened compared with those in the control group (p < 0.01). The peak intensity (PI) in CEUS of the tendons showed a clear difference at each time point after the surgery (p < 0.01). PI increased in the operation group with a maximum on day 7, and then gradually decreased until day 28 when PI was close to the basic intensity (BI) in the control group (p > 0.05). It was consistent with the change of the CD31-positive staining areas representing angiogenesis of the injured patellar tendons. The PI was positively correlated with the CD31-positive staining area fraction (R = 0.849, p < 0.001). The failure load and tensile strength of the repaired patellar tendons in the operation group increased over time. The PI showed negative correlations with the failure load (R = -0.787, p < 0.001) and tensile strength (R = -0.714, p < 0.001). Conclusion The PI in CEUS could quantitatively reflect the time-dependent change in the blood supply of the healing site, and the PI correlated with histologic and biomechanical properties of the healing tendon. Quantitative analysis of contrast-enhanced ultrasound could be a useful method to evaluate angiogenesis in healing tendons.
Collapse
|
4
|
Yi HM, Lowerison MR, Song PF, Zhang W. A Review of Clinical Applications for Super-resolution Ultrasound Localization Microscopy. Curr Med Sci 2022; 42:1-16. [PMID: 35167000 DOI: 10.1007/s11596-021-2459-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 03/11/2021] [Indexed: 12/21/2022]
Abstract
Microvascular structure and hemodynamics are important indicators for the diagnosis and assessment of many diseases and pathologies. The structural and functional imaging of tissue microvasculature in vivo is a clinically significant objective for the development of many imaging modalities. Contrast-enhanced ultrasound (CEUS) is a popular clinical tool for characterizing tissue microvasculature, due to the moderate cost, wide accessibility, and absence of ionizing radiation of ultrasound. However, in practice, it remains challenging to demonstrate microvasculature using CEUS, due to the resolution limit of conventional ultrasound imaging. In addition, the quantification of tissue perfusion by CEUS remains hindered by high operator-dependency and poor reproducibility. Inspired by super-resolution optical microscopy, super-resolution ultrasound localization microscopy (ULM) was recently developed. ULM uses the same ultrasound contrast agent (i.e. microbubbles) in CEUS. However, different from CEUS, ULM uses the location of the microbubbles to construct images, instead of using the backscattering intensity of microbubbles. Hence, ULM overcomes the classic compromise between imaging resolution and penetration, allowing for the visualization of capillary-scale microvasculature deep within tissues. To date, many in vivo ULM results have been reported, including both animal (kidney, brain, spinal cord, xenografted tumor, and ear) and human studies (prostate, tibialis anterior muscle, and breast cancer tumors). Furthermore, a variety of useful biomarkers have been derived from using ULM for different preclinical and clinical applications. Due to the high spatial resolution and accurate blood flow speed estimation (approximately 1 mm/s to several cm/s), ULM presents as an enticing alternative to CEUS for characterizing tissue microvasculature in vivo. This review summarizes the principles and present applications of CEUS and ULM, and discusses areas where ULM can potentially provide a better alternative to CEUS in clinical practice and areas where ULM may not be a better alternative. The objective of the study is to provide clinicians with an up-to-date review of ULM technology, and a practical guide for implementing ULM in clinical research and practice.
Collapse
Affiliation(s)
- Hui-Ming Yi
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA
| | - Matthew R Lowerison
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA
| | - Peng-Fei Song
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA
| | - Wei Zhang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. .,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA. .,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.
| |
Collapse
|