Meier J, Hembus J, Bader R, Vogel D. Computer-based analysis of the taper connection strength of different revision head and adapter sleeve designs. BIOMED ENG-BIOMED TE 2024; 69:199-209. [PMID: 37698840 DOI: 10.1515/bmt-2023-0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 08/28/2023] [Indexed: 09/13/2023]
Abstract
OBJECTIVES Ceramic revision heads, equipped with titanium adapter sleeves, are used in femoral head revision in total hip arthroplasty to avoid ceramic fracture due to the damaged taper. METHODS A finite element analysis of the taper connection strength of revision heads with varying head diameters combined with adapter sleeves of different lengths was conducted. The influence of various assembly forces, head diameter, and length of the adapter sleeves was evaluated. For two combinations, the pattern of contact pressure was evaluated when applying a simplified joint load (3 kN, 45° load angle). Experimental validation was conducted with 36 mm heads and adapter sleeves in size S, as well as 28 mm heads and adapter sleeves in size XL. RESULTS The pull-off force increased with higher assembly forces. Using larger head diameters and adapter sleeves led to decreased pull-off forces, a reduced contact surface, and less contact pressure. The contact pressure showed significant peaks and a diagonal pattern under 45° angle loading when assembly forces were less than 4 kN, and larger adapter sleeves were utilized. CONCLUSION A sufficient assembly force should be ensured intraoperatively, especially with an increasing head diameter and adapter sleeve size, as lower assembly forces might lead to reduced taper connection strength.
Collapse
Affiliation(s)
- Johanna Meier
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Jessica Hembus
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Danny Vogel
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
2
|
Kyomoto M, Moro T, Yamane S, Watanabe K, Hashimoto M, Tanaka S, Ishihara K. Efficacy of hydrated phospholipid polymer interfaces between all-polymer bearings for total hip arthroplasty. J Biomed Mater Res B Appl Biomater 2021; 110:89-102. [PMID: 34128321 DOI: 10.1002/jbm.b.34892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 04/28/2021] [Accepted: 06/07/2021] [Indexed: 11/10/2022]
Abstract
Measurements of wear resistance and metal ion release are important for designing bearing couples or interfaces in total hip arthroplasty (THA). In this study, we investigated wear resistance and metal ion release of surface-modified metal-free all-polymer hip bearings, such as poly(ether-ether-ketone), (PEEK) on cross-linked polyethylene (PEEK-on-CLPE), with a hydrated gel-like surface layer, to propose an improved alternative to the conventional materials used to design THA bearings. The PEEK surface resulted in less metal ion release than the cobalt-chromium-molybdenum (Co-Cr-Mo) alloy surface owing to the lack of metal. The PEEK-on-CLPE bearing (6.33 mg/106 cycles) had lower wear (rate) than the bearing with Co-Cr-Mo alloy-on-CLPE (10.47 mg/106 cycles) under controlled laboratory conditions; the wear performance of the all-polymer hip bearings was further improved with hemi- or both-surface modified with a hydrated poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) layer (3.74 and 3.06 mg/106 cycles, respectively). The PMPC-grafted interface of PEEK-on-CLPE will be especially suitable for THA candidates. This study is of key importance for the design of lifelong THA and a better understanding of the limitations resulting from using PEEK. Further studies are necessary to evaluate the possibility of using this material in artificial hips.
Collapse
Affiliation(s)
- Masayuki Kyomoto
- Department of Materials Engineering, School of Engineering, The University of Tokyo, Tokyo, Japan.,Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.,Medical R&D Center, Corporate R&D Group, KYOCERA Corporation, Yasu, Japan
| | - Toru Moro
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.,Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Shihori Yamane
- Department of Materials Engineering, School of Engineering, The University of Tokyo, Tokyo, Japan.,Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.,Medical R&D Center, Corporate R&D Group, KYOCERA Corporation, Yasu, Japan
| | - Kenichi Watanabe
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.,Medical R&D Center, Corporate R&D Group, KYOCERA Corporation, Yasu, Japan
| | - Masami Hashimoto
- Materials Research and Development Laboratory, Japan Fine Ceramics Center, Nagoya, Japan
| | - Sakae Tanaka
- Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Kazuhiko Ishihara
- Department of Materials Engineering, School of Engineering, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
3
|
"Off-label" Usage of an Oxidized Zirconium Femoral Head in Revision of a Total Hip Arthroplasty with Mechanically Assisted Crevice Corrosion and a Legacy Taper. Arthroplast Today 2021; 8:69-73. [PMID: 33681438 PMCID: PMC7930501 DOI: 10.1016/j.artd.2021.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 01/23/2021] [Indexed: 11/22/2022] Open
Abstract
We present a case of a 72-year-old male with a history of a late 1980s metal-on-polyethylene total hip arthroplasty who presented with unilateral leg vascular compromise, joint pain, and stiffness and subsequently underwent revision for adverse local tissue reaction secondary to mechanically assisted crevice corrosion. His stable and extensively porous coated femoral implant had a legacy taper with no currently manufactured option for a non–Co-alloy femoral head. After shared decision-making with the patient, we opted to use an oxidized zirconium femoral head from another manufacturer with a similar taper during his revision surgery and documented that his vascular compromise resolved and his serum Co was undetectable 3 years after the revision.
Collapse
|