1
|
Determination of Vitamin B12 in Milk and Dairy Products by Isotope-Dilution Liquid Chromatography Tandem Mass Spectrometry. J FOOD QUALITY 2022. [DOI: 10.1155/2022/7649228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
An isotope-dilution liquid chromatography tandem mass spectrometry method was established for the determination of vitamin B12 in milk and dairy products. The samples were spiked with stable isotope-labeled vitamin B12 and digested by pepsin and amylase. The various forms of cobalamin were transformed to cyanocobalamin by potassium cyanide after they were released from the enzymatically digested samples. Cyanocobalamin was extracted and purified by an immunoaffinity SPE cartridge and then measured in multiple reaction monitoring mode (MRM). The linear correlation coefficient (R2) of this method was greater than 0.999 in the range of 2–100 ng/mL. The detection limit and the quantification limit were 0.5 μg/kg and 1.0 μg/kg, respectively. The spiked recoveries ranged from 92.0% to 99.4% at the three spiked levels with the relative standard deviation (RSD) between 1.89% and 4.51%. The measured results of NIST SRM1849a and NIST SRM1869a by the current method are all within the reference value range. The Z value was 0.8 during participating in the FAPAS proficiency test using the developed method in 2021. The method is simple, rapid, accurate, and sensitive, and it is suitable for the determination of vitamin B12 in different types of milk and dairy products such as whey powder, whole milk powder, pure milk, fermented milk, infant formula, and prescription food for special medical purposes.
Collapse
|
2
|
Simultaneous Determination of Retinols and Tocols in Egg and Milk Products Based on RP-HPLC Linked with Fluorescent and Photodiode Array. J FOOD QUALITY 2022. [DOI: 10.1155/2022/8431662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
In this paper, we built a method of verifying the 4 retinols of vitamin A and 8 tocopherol isomers of vitamin E in the food industry based on RP-HPLC-PDA-FLR. The effect of laboratory light conditions on the target components was considered for the first time, and it was found that the loss rate of the target components was the smallest in the case of a white laboratory bench with red or LED light in the dark room. There was no finding of extraction recoveries of the target components with a significant difference under different saponification conditions. Meanwhile, it was found that using ethyl acetate/n-hexane mixed solvent as the extraction solvent could ensure the effective extraction of the target components. Finally, baseline separation of 12 components was achieved within 45 min using the C30 column. With the help of methodological verification, we found that the recovery rate ranged from 76.45% to 93.52%, and RSD was between 0.19% and 12.99%; the Limit of Detection minimum value was 0.01 mg/100 g and the Limit of Quantitation minimum value was 0.03 mg/100 g. The detection method was successfully applied to the distribution detection of 4 kinds of retinols and 8 kinds of vitamin E in egg and dairy products and provided technical support for the accurate nutritional evaluation of vitamin A and vitamin E.
Collapse
|