Ni Z, Zhou Y, Tang N, Yu H, Liang Z. Comparison of actual performance in humidification among different high-flow nasal cannula devices: a bench study. Front Med (Lausanne) 2023; 10:1209977. [PMID: 37359006 PMCID: PMC10288384 DOI: 10.3389/fmed.2023.1209977] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 05/19/2023] [Indexed: 06/28/2023] Open
Abstract
Background The physiological effects of HFNC devices are closely related to temperature and humidity. HFNC devices from different manufacturers may have varied performances. It is unclear whether there are differences in the humidification performance of different HFNC devices and the degree of differences. Methods Four integrated HFNC devices (AIRVO 2, Fisher & Paykel Healthcare, Auckland, New Zealand; TNI softFlow 50, TNI Medical AG, Würzburg, Germany; HUMID-BH, RESPIRACARE, Shenyang, China; OH-70C, Micomme, Hunan, China) and a ventilator with an HFNC module (bellavista 1000, Imtmedical, Buchs, Switzerland) were evaluated using their matching circuits. The dew point temperature was set at 31, 34, and 37°C (set-DP). In MR850, it was set to non-invasive mode (34°C/-3°C) and invasive mode (40°C/-3°C), respectively. At each level of set-DP, the flow was set from 20 L/min up to its maximum set limit at a gradient of 5 L/min or 10 L/min. After stabilization, the dew point temperature, temperature, relative humidity, and flow rate of the delivered gas from the cannulas were recorded. Results There were significant differences in actual-DP among these devices at any set-DP (p < 0.001). The actual-DP of OH-70C and TNI softFlow 50 was lower than set-DP, and the difference between the actual-DP and the set-DP of these two devices increased with the increase of set-DP. AIRVO 2, bellavista 1000 (MR850), and HUMID-BH can provide the nominal humidity at 37°C. The actual-DP increased with the increase of set-flow under each set-DP in AIRVO 2, TNI softFlow 50 and bellavista 1000 (MR850), but decreased when the set-flow was greater than 60 L/min. The actual-T of the delivered gas was higher than actual-DP in all devices and was higher than set-DP in AIRVO 2 and HUMID-BH. Conclusion Set-flow, set-DP, and types of devices will affect the actual temperature and humidity of the delivered gas. AIRVO 2, bellavista 1000 (MR850), and HUMID-BH can provide the nominal humidity at 37°C and may be more suitable for tracheotomy patients. The flow rate over 60 L/min should be set with caution.
Collapse
|
2
|
Pérez-Nieto OR, Gómez-Oropeza I, Quintero-Leyra A, Kammar-García A, Zamarrón-López ÉI, Soto-Estrada M, Morgado-Villaseñor LA, Meza-Comparán HD. Hemodynamic and respiratory support in pulmonary embolism: a narrative review. Front Med (Lausanne) 2023; 10:1123793. [PMID: 37332759 PMCID: PMC10272848 DOI: 10.3389/fmed.2023.1123793] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 05/19/2023] [Indexed: 06/20/2023] Open
Abstract
Pulmonary embolism is a common and potentially fatal disease, with a significant burden on health and survival. Right ventricular dysfunction and hemodynamic instability are considered two key determinants of mortality in pulmonary embolism, which can reach up to 65% in severe cases. Therefore, timely diagnosis and management are of paramount importance to ensure the best quality of care. However, hemodynamic and respiratory support, both major constituents of management in pulmonary embolism, associated with cardiogenic shock or cardiac arrest, have been given little attention in recent years, in favor of other novel advances such as systemic thrombolysis or direct oral anticoagulants. Moreover, it has been implied that current recommendations regarding this supportive care lack enough robustness, further complicating the problem. In this review, we critically discuss and summarize the current literature concerning the hemodynamic and respiratory support in pulmonary embolism, including fluid therapy, diuretics, pharmacological support with vasopressors, inotropes and vasodilators, oxygen therapy and ventilation, and mechanical circulatory support with veno-arterial extracorporeal membrane oxygenation and right ventricular assist devices, while also providing some insights into contemporary research gaps.
Collapse
Affiliation(s)
| | - Irene Gómez-Oropeza
- Department of Health Science, Universidad de las Américas Puebla, San Andrés Cholula, Puebla, Mexico
| | | | - Ashuin Kammar-García
- Dirección de Investigación, Instituto Nacional de Geriatría, Mexico City, Mexico
| | | | - Maximiliano Soto-Estrada
- Departamento de Emergencias, Hospital General de Zona 11 IMSS Delicias, Delicias, Chihuahua, Mexico
| | | | | |
Collapse
|
3
|
Liu W, Zhu M, Xia L, Yang X, Huang P, Sun Y, Shen Y, Ma J. Transnasal High-Flow Oxygen Therapy versus Noninvasive Positive Pressure Ventilation in the Treatment of COPD with Type II Respiratory Failure: A Meta-Analysis. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:3835545. [PMID: 35928976 PMCID: PMC9345699 DOI: 10.1155/2022/3835545] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 06/11/2022] [Accepted: 06/22/2022] [Indexed: 11/19/2022]
Abstract
Objective To compare the safety and efficacy of transnasal high-flow oxygen therapy (HFNT) and noninvasive positive pressure ventilation (NIV) in the treatment of chronic obstructive pulmonary disease (COPD) with type II respiratory failure. Methods PubMed, the Cochrane Library, Embase, CBM, CNKI, and other databases were searched for randomized controlled trials (RCTS) on the efficacy of HFNT and NIV in the treatment of COPD. Meta-analysis was conducted using RevMan 5.3 software after two researchers screened literatures, extracted data, and evaluated the methodological quality of the included studies according to inclusion and exclusion criteria. Results A total of 948 patients were included in 12 RCTS. Comprehensive analysis results showed that the HFNC group had higher levels of 12 h-PAO2, 48 h-PACO2 and, 48 h-pH than the NIV group, and the differences were statistically significant (P < 0.05). There were no significant differences in 24 h-PAO2 and 72 h-PAO2, 12 h-PACO2, 24 h-PACO2 and 72 h-PACO2, 24 h-pH, 48 h-pH, and 72 h-pH between the two groups after treatment (P > 0.05). Conclusions Compared with NIV, HFNC does not increase the treatment failure rate in COPD patients with type II respiratory failure, and HFNC has better comfort and tolerance, which is a new potential respiratory support treatment for COPD patients with type II respiratory failure.
Collapse
Affiliation(s)
- Wei Liu
- Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Mingli Zhu
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Liuqin Xia
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Xiangying Yang
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Pei Huang
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Yanming Sun
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Ye Shen
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| | - Jianping Ma
- Department of Critical Care Medicine, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China
| |
Collapse
|
4
|
Wen R, Hu X, Wei T, Wang K, Duan Z, Zhao Z, Xie L, Xie F. High-flow nasal cannula: Evaluation of the perceptions of various performance aspects among Chinese clinical staff and establishment of a multidimensional clinical evaluation system. Front Med (Lausanne) 2022; 9:900958. [PMID: 35911388 PMCID: PMC9335197 DOI: 10.3389/fmed.2022.900958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 06/27/2022] [Indexed: 11/19/2022] Open
Abstract
Objective In order to facilitate education for clinical users, performance aspects of the high-flow nasal cannula (HFNC) devices were evaluated in the present study. A multidimensional HFNC clinical evaluation system was established accordingly. Materials and Methods Clinical staff from Chinese hospitals were invited to participate in an online questionnaire survey. The questionnaire was mainly about the accuracy of temperature, flow rate, and oxygen concentration of HFNC, as well as its humidification capacity. We also investigated how the clinical staff of different professions made decisions on HFNC evaluation indicators. Based on the results of the questionnaire survey of clinicians with rich experience in using HFNC, the relative weights of temperature accuracy, flow velocity accuracy, oxygen concentration accuracy, and humidification ability of HFNC equipment were calculated by the AHP to establish a clinical evaluation system. Four kinds of common HFNC devices were tested and evaluated, and the clinical performance of the four kinds of HFNC devices was evaluated by the new scoring system. Results A total of 356 clinicians participated in and completed the questionnaire survey. To ensure the reliability of the HFNC evaluation system, we only adopted the questionnaire results of clinicians with rich experience in using HFNCs. Data from 247 questionnaires (80 doctors, 105 nurses, and 62 respiratory therapists [RTs]) were analyzed. A total of 174 participants used HFNC more than once a week; 88.71% of RTs used HFNC ≥ 1 score daily, 62.86% of nurses used HFNC ≥ 1 score daily, and 66.25% of doctors used HFNC ≥ 1 daily. There was no significant difference in the frequency of use between doctors and nurses. Finally, the relative weights of temperature accuracy (0.088), humidification capacity (0.206), flow velocity accuracy (0.311), and oxygen concentration accuracy (0.395) in the HFNC clinical evaluation system were obtained. The relative weights of clinicians with different occupations and the frequency of HFNC use were obtained. After testing four kinds of HFNC devices through the evaluation system, it was found that the four kinds of HFNC devices have different advantages in different clinical performances, and AiRVO2 has excellent performance with regard to temperature accuracy and humidification ability. HF-75A and NeoHiF-i7 are good at ensuring the stability of oxygen concentration and the accuracy of the flow velocity of the transported gas, while OH-80S is relatively stable in all aspects. Conclusion The clinical evaluation system of HFNC is based on the weight of the experience of clinical personnel with different medical backgrounds. Although the existing practitioners have different educational backgrounds (academic qualifications, majors), our evaluation system can enhance clinical staff’s awareness of HFNC and further optimize the clinical use of HFNC.
Collapse
Affiliation(s)
- Ruoxuan Wen
- College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, China
| | - Xingshuo Hu
- College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, China
| | - Tengchen Wei
- Department of Respiratory Medicine, 907 Hospital of the Joint Logistics Team, Nanping, China
| | - Kaifei Wang
- College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, China
| | - Zhimei Duan
- College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, China
| | - Zhanqi Zhao
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
- Zhanqi Zhao,
| | - Lixin Xie
- College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, China
- Lixin Xie,
| | - Fei Xie
- College of Pulmonary and Critical Care Medicine, Chinese PLA General Hospital, Beijing, China
- *Correspondence: Fei Xie,
| |
Collapse
|
5
|
Weinreich UM, Burchardt C, Huremovic J. The effect of domiciliary high flow nasal cannula treatment on dyspnea and walking distance in patients with interstitial lung disease - A pilot study. Chron Respir Dis 2022; 19:14799731221137085. [PMID: 36366859 PMCID: PMC9661555 DOI: 10.1177/14799731221137085] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024] Open
Abstract
INTRODUCTION Interstitial Lung Diseases (ILD) affect the lung parenchyma and are often complicated by respiratory failure (RF) and impaired physical activity. High Flow Nasal Cannula (HFNC) has proved effective in other disease entities with RF. The aim of this study is to investigate the effect of domiciliary HFNC in ILD on dyspnea and walking distance. METHODS A 6 weeks cross-over study with domiciliary HFNC-treatment/6 weeks' observation in ILD-patients requiring ambulatory oxygen therapy or with newly prescribed (within 12 months) long term oxygen therapy. Patients were advised to use HFNC 8 h/day, recommended night-time use. Body phletysmography; 6-min walk test (6MWT) including BORG-score, oxygen saturation (SO2) at start, minimum SO2 and time to recovery after 6MWT; arterial blood gasses; modified Medical Research Council (mMRC)-score; quality of life, by the St George Respiratory Questionnaire (SGRQ) and QoS, by the Richards-Campbell Sleep Questionnaire (RCSQ) were investigated at baseline; six weeks and 12 weeks. RESULTS 10 patients were included; one later withdrew consent. Patients used HFNC between 8-<1 h/day. There were no differences in lung function; blood gasses; SGRQ or RCSQ over the observational period). Walking distance improved significantly (393-441 m p = 0.049) as did time to recovery (3.4-2-2 min, p = 0.001). When correcting for HFNC use (hours/day) significant improvement was also seen in mMRC-score (p = 0.035) and minimum saturation during 6MWT (p = 0.01). CONCLUSION Despite a very heterogenous group and no effect on quality of life and -sleep, the study indicates an improvement in dyspnea and physical ability of HFNC in ILD patients.
Collapse
Affiliation(s)
- Ulla Møller Weinreich
- Department of Respiratory Diseases, Aalborg University Hospital, Aalborg, Denmark
- The Clinical Department, Aalborg University, Aalborg, Denmark
| | - Charlotte Burchardt
- Department of Respiratory Diseases, Aalborg University Hospital, Aalborg, Denmark
| | - Jasmina Huremovic
- Department of Respiratory Diseases, Aalborg University Hospital, Aalborg, Denmark
| |
Collapse
|