Uribe Rivera AK, Seeliger B, Goffin L, García-Vázquez A, Mutter D, Giménez ME. Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis. ANNALS OF SURGERY OPEN 2024; 5:e406. [PMID: 38911657 PMCID: PMC11191991 DOI: 10.1097/as9.0000000000000406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 02/19/2024] [Indexed: 06/25/2024] Open
Abstract
Objective The aim of this systematic review and meta-analysis is to identify current robotic assistance systems for percutaneous liver ablations, compare approaches, and determine how to achieve standardization of procedural concepts for optimized ablation outcomes. Background Image-guided surgical approaches are increasingly common. Assistance by navigation and robotic systems allows to optimize procedural accuracy, with the aim to consistently obtain adequate ablation volumes. Methods Several databases (PubMed/MEDLINE, ProQuest, Science Direct, Research Rabbit, and IEEE Xplore) were systematically searched for robotic preclinical and clinical percutaneous liver ablation studies, and relevant original manuscripts were included according to the Preferred Reporting items for Systematic Reviews and Meta-Analyses guidelines. The endpoints were the type of device, insertion technique (freehand or robotic), planning, execution, and confirmation of the procedure. A meta-analysis was performed, including comparative studies of freehand and robotic techniques in terms of radiation dose, accuracy, and Euclidean error. Results The inclusion criteria were met by 33/755 studies. There were 24 robotic devices reported for percutaneous liver surgery. The most used were the MAXIO robot (8/33; 24.2%), Zerobot, and AcuBot (each 2/33, 6.1%). The most common tracking system was optical (25/33, 75.8%). In the meta-analysis, the robotic approach was superior to the freehand technique in terms of individual radiation (0.5582, 95% confidence interval [CI] = 0.0167-1.0996, dose-length product range 79-2216 mGy.cm), accuracy (0.6260, 95% CI = 0.1423-1.1097), and Euclidean error (0.8189, 95% CI = -0.1020 to 1.7399). Conclusions Robotic assistance in percutaneous ablation for liver tumors achieves superior results and reduces errors compared with manual applicator insertion. Standardization of concepts and reporting is necessary and suggested to facilitate the comparison of the different parameters used to measure liver ablation results. The increasing use of image-guided surgery has encouraged robotic assistance for percutaneous liver ablations. This systematic review analyzed 33 studies and identified 24 robotic devices, with optical tracking prevailing. The meta-analysis favored robotic assessment, showing increased accuracy and reduced errors compared with freehand technique, emphasizing the need for conceptual standardization.
Collapse
Affiliation(s)
- Ana K Uribe Rivera
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
| | - Barbara Seeliger
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
- Department of Visceral and Digestive Surgery, University Hospitals of Strasbourg, Strasbourg, France
- IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France
- ICube, UMR 7357 CNRS, INSERM U1328 RODIN, University of Strasbourg, Strasbourg, France
- Inserm U1110, Institute for Viral and Liver Diseases, Strasbourg. France
- Trustworthy AI Lab, Centre National de la Recherche Scientifique (CNRS), France
| | - Laurent Goffin
- ICube, UMR 7357 CNRS, INSERM U1328 RODIN, University of Strasbourg, Strasbourg, France
- Trustworthy AI Lab, Centre National de la Recherche Scientifique (CNRS), France
- Computational Surgery SAS, Schiltigheim, France
| | | | - Didier Mutter
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
- Department of Visceral and Digestive Surgery, University Hospitals of Strasbourg, Strasbourg, France
- IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France
| | - Mariano E Giménez
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
- IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France
- DAICIM Foundation (Training, Research and Clinical Activity in Minimally Invasive Surgery), Buenos Aires, Argentina
| |
Collapse
|
2
|
Zhou J, Li M, Li N, Zhou Y, Wang J, Jiao N. System integration of magnetic medical microrobots: from design to control. Front Robot AI 2023; 10:1330960. [PMID: 38169802 PMCID: PMC10758462 DOI: 10.3389/frobt.2023.1330960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 11/28/2023] [Indexed: 01/05/2024] Open
Abstract
Magnetic microrobots are ideal for medical applications owing to their deep tissue penetration, precise control, and flexible movement. After decades of development, various magnetic microrobots have been used to achieve medical functions such as targeted delivery, cell manipulation, and minimally invasive surgery. This review introduces the research status and latest progress in the design and control systems of magnetic medical microrobots from a system integration perspective and summarizes the advantages and limitations of the research to provide a reference for developers. Finally, the future development direction of magnetic medical microrobot design and control systems are discussed.
Collapse
Affiliation(s)
- Junjian Zhou
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Mengyue Li
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Na Li
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Yuting Zhou
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Jingyi Wang
- College of Information and Electrical Engineering, Shenyang Agricultural University, Shenyang, China
| | - Niandong Jiao
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang, China
| |
Collapse
|
3
|
Takagi R, Osada K, Hanafusa A, Takagi M, Mohamaddan SB, Mitsui K, Anzai H. Development of a remote-control system for catheterization capable of high-speed force feedback. Int J Comput Assist Radiol Surg 2023; 18:763-773. [PMID: 36689147 PMCID: PMC10039843 DOI: 10.1007/s11548-022-02815-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 12/19/2022] [Indexed: 01/24/2023]
Abstract
PURPOSE There is a growing interest in minimally invasive surgery as interventional radiology (IVR), which decreases the burden on a patient. However, occupational exposure is a problem because the treatment is performed using X-ray fluoroscopic images. This problem can be solved by the development of a teleoperation system, but rapid force presentation is important to perform safe surgery. The purpose of this study is to develop a new teleoperation system that can be controlled at a high speed and can provide feedback force sensation within 20 ms delay. METHODS A master-slave-type remote-control system for catheterization was developed. A compact and high-speed force feedback system is realized using a novel electro-attractive material (EAM) device by which the resistance force is generated by the magnitude of the voltage applied. The linear and rotational movement of master is transferred to the slave device by UDP communication with the LAN cable, and the same movement is performed by two motors. The collision force of catheter or guidewire, detected by the sensor inside the slave device, is also transmitted to the master device. Two voltage-based methods for EAM: the ON/OFF and linear control methods, were implemented. RESULTS After the collision force is detected by the slave sensor, the voltage is applied to the EAM in the master device for an average of 10.33 ms and 15.64 ms by the ON/OFF and linear control methods, respectively. These delays are less than required 20 ms. The movement of the master was stopped by the resistance force of EAM, and that of the slave was also stopped accordingly. CONCLUSION A master-slave-type remote-control system for catheterization that is capable of high-speed force feedback was developed. With a low delay, the developed system achieved the requirements of 20 ms that was aimed for this study. Therefore, this system may facilitate the realization of IVR surgery that is safe for both doctors and patients.
Collapse
Affiliation(s)
- Rei Takagi
- Department of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan
| | - Keita Osada
- Department of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan
| | - Akihiko Hanafusa
- Department of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan.
| | - Motoki Takagi
- Department of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan
| | - Shahrol Bin Mohamaddan
- Department of Bio-Science and Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-Ku, Saitama, 337-8570, Japan
| | - Kazuyuki Mitsui
- Department of Advanced Machinery Engineering, Tokyo Denki University, Tokyo, Japan
| | | |
Collapse
|
4
|
Marcos-Pablos S, García-Peñalvo FJ. More than surgical tools: a systematic review of robots as didactic tools for the education of professionals in health sciences. ADVANCES IN HEALTH SCIENCES EDUCATION : THEORY AND PRACTICE 2022; 27:1139-1176. [PMID: 35771316 PMCID: PMC9244888 DOI: 10.1007/s10459-022-10118-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 04/23/2022] [Indexed: 06/15/2023]
Abstract
Within the field of robots in medical education, most of the work done during the last years has focused on surgeon training in robotic surgery, practicing surgery procedures through simulators. Apart from surgical education, robots have also been widely employed in assistive and rehabilitation procedures, where education has traditionally focused in the patient. Therefore, there has been extensive review bibliography in the field of medical robotics focused on surgical and rehabilitation and assistive robots, but there is a lack of survey papers that explore the potential of robotics in the education of healthcare students and professionals beyond their training in the use of the robotic system. The scope of the current review are works in which robots are used as didactic tools for the education of professionals in health sciences, investigating the enablers and barriers that affect the use of robots as learning facilitators. Systematic literature searches were conducted in WOS and Scopus, yielding a total of 3812 candidate papers. After removing duplicates, inclusion criteria were defined and applied, resulting in 171 papers. An in-depth quality assessment was then performed leading to 26 papers for qualitative synthesis. Results show that robots in health sciences education are still developed with a roboticist mindset, without clearly incorporating aspects of the teaching/learning process. However, they have proven potential to be used in health sciences as they allow to parameterize procedures, autonomously guide learners to achieve greater engagement, or enable collective learning including patients and instructors "in the loop". Although there exist documented added-value benefits, further research and efforts needs to be done to foster the inclusion of robots as didactic tools in the curricula of health sciences professionals. On the one hand, by analyzing how robotic technology should be developed to become more flexible and usable to support both teaching and learning processes in health sciences education, as final users are not necessarily well-versed in how to use it. On the other, there continues to be a need to develop effective and standard robotic enhanced learning evaluation tools, as well good quality studies that describe effective evaluation of robotic enhanced education for professionals in health sciences. As happens with other technologies when applied to the health sciences field, studies often fail to provide sufficient detail to support transferability or direct future robotic health care education programs.
Collapse
Affiliation(s)
- Samuel Marcos-Pablos
- GRIAL Research Group, University of Salamanca, IUCE, Paseo de Canalejas 169, 37008 Salamanca, Spain
| | | |
Collapse
|
5
|
Chen K, M Beeraka N, Zhang J, Reshetov IV, Nikolenko VN, Sinelnikov MY, Mikhaleva LM. Efficacy of da Vinci robot-assisted lymph node surgery than conventional axillary lymph node dissection in breast cancer - A comparative study. Int J Med Robot 2021; 17:e2307. [PMID: 34270843 DOI: 10.1002/rcs.2307] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 07/01/2021] [Accepted: 07/07/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND da Vinci robot-assisted axillary lymph node dissection (dVALND) can be a minimally invasive technique to minimize post-operative complications. OBJECTIVE To explore the clinical efficacy of dVALND in breast cancer (BC) patients for mitigating the postoperative complications than conventional ALND. METHODS Total 60 female patients with BC were admitted to our hospitals since September 2018, and these patients segregated into two groups of 30 patients each. Modified radical mastectomy for BC was performed to the patients in both groups. In Group 1 (control group), ALND was performed using conventional mode of axillary lymph node surgery. In Group 2 (Test group), the dVALND was performed using da Vinci robot-assisted surgery. Wound healing, aesthetic effect and patient's satisfaction were evaluated after conventional method and dVALND. RESULTS Postoperative complications viz., wound infection (1/30 (3.33%), p < 0.05), fat necrosis (3/30 (10%), p < 0.05) and lymphedema of upper limbs (2/30 (6.67%), p < 0.05) were observed in dVALND than conventional surgery. Local recurrence or metastasis was minimized and overall aesthetic effect not observed during follow-up. CONCLUSION dVALND improved the overall patient's quality of life by mitigating postoperative complications than ALND.
Collapse
Affiliation(s)
- Kuo Chen
- Department of Breast Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.,I. M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Moscow, Russia
| | - Narasimha M Beeraka
- I. M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Moscow, Russia.,Center of Excellence in Molecular Biology and Regenerative Medicine (CEMR), Department of Biochemistry, JSS Academy of Higher Education and Research (JSS AHER), JSS Medical College, Mysuru, India
| | - Jin Zhang
- Department of Breast Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Igor V Reshetov
- I. M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Moscow, Russia
| | - Vladimir N Nikolenko
- I. M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Moscow, Russia
| | - Mikhail Y Sinelnikov
- I. M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Moscow, Russia
| | | |
Collapse
|
6
|
Method of Using RealSense Camera to Estimate the Depth Map of Any Monocular Camera. JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING 2021. [DOI: 10.1155/2021/9152035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Robot detection, recognition, positioning, and other applications require not only real-time video image information but also the distance from the target to the camera, that is, depth information. This paper proposes a method to automatically generate any monocular camera depth map based on RealSense camera data. By using this method, any current single-camera detection system can be upgraded online. Without changing the original system, the depth information of the original monocular camera can be obtained simply, and the transition from 2D detection to 3D detection can be realized. In order to verify the effectiveness of the proposed method, a hardware system was constructed using the Micro-vision RS-A14K-GC8 industrial camera and the Intel RealSense D415 depth camera, and the depth map fitting algorithm proposed in this paper was used to test the system. The results show that, except for a few depth-missing areas, the results of other areas with depth are still good, which can basically describe the distance difference between the target and the camera. In addition, in order to verify the scalability of the method, a new hardware system was constructed with different cameras, and images were collected in a complex farmland environment. The generated depth map was good, which could basically describe the distance difference between the target and the camera.