1
|
Noten AME, Romanov A, De Schouwer K, Beloborodov V, Bhagwandien R, Hoogendijk MG, Mikheenko I, Wijchers S, Yap SC, Schwagten B, Szili-Torok T. Robotic magnetic navigation-guided catheter ablation establishes highly effective pulmonary vein isolation in patients with paroxysmal atrial fibrillation when compared to conventional ablation techniques. J Cardiovasc Electrophysiol 2023; 34:2472-2483. [PMID: 37767745 DOI: 10.1111/jce.16081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/10/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023]
Abstract
INTRODUCTION Pulmonary vein isolation (PVI) is a pivotal part of ablative therapy for atrial fibrillation (AF). Currently, there are multiple techniques available to realize PVI, including: manual-guided cryoballoon (MAN-CB), manual-guided radiofrequency (MAN-RF), and robotic magnetic navigation-guided radiofrequency ablation (RMN-RF). There is a lack of large prospective trials comparing contemporary RMN-RF with the more conventional ablation techniques. This study prospectively compared three catheter ablation techniques as treatment of paroxysmal AF. METHODS This multicenter, prospective study included patients with paroxysmal AF who underwent their first ablation procedure. Procedural parameters (including procedural efficiency), complication rates, and freedom of AF during 12-month follow-up, were compared between three study groups which were defined by the utilized ablation technique. RESULTS A total of 221 patients were included in this study. Total procedure time was significantly shorter in MAN-CB (78 ± 21 min) compared to MAN-RF (115 ± 41 min; p < .001) and compared to RMN-RF (129 ± 32 min; p < .001), whereas it was comparable between the two radiofrequency (RF) groups (p = .062). A 3% complication rate was observed, which was comparable between all groups. At 12-month follow-up, AF recurrence was observed in 40 patients (19%) and was significantly lower in the robotic group (MAN-CB 19 [24%], MAN-RF 16 [23%], RMN-RF 5 [8%] AF recurrences, p = .045) (multivariate hazard ratio of RMN-RF on AF recurrence 0.32, 95% confidence interval: 0.12-0.87, p = .026). CONCLUSION RMN-guided PVI results in high freedom of AF in patients with paroxysmal AF, when compared to cryoablation and manual RF ablation. Cryoablation remains the most time-efficient ablation technique, whereas RMN nowadays has comparable efficiency with manual RF ablation.
Collapse
Affiliation(s)
- Anna M E Noten
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Alexander Romanov
- E. Meshalkin National Medical Research Center of the Ministry of Health of the Russian Federation, Novosibirsk, Russia
| | - Koen De Schouwer
- Department of Cardiology, Ziekenhuis Netwerk Antwerpen, Antwerp, Belgium
| | - Vladimir Beloborodov
- E. Meshalkin National Medical Research Center of the Ministry of Health of the Russian Federation, Novosibirsk, Russia
| | - Rohit Bhagwandien
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Mark G Hoogendijk
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Igor Mikheenko
- E. Meshalkin National Medical Research Center of the Ministry of Health of the Russian Federation, Novosibirsk, Russia
| | - Sip Wijchers
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Sing-Chien Yap
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Bruno Schwagten
- Department of Cardiology, Ziekenhuis Netwerk Antwerpen, Antwerp, Belgium
| | - Tamas Szili-Torok
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
2
|
Cai C, Wang J, Niu HX, Chu JM, Hua W, Zhang S, Yao Y. Clinical outcome of lesion size index-guided high-power radiofrequency catheter ablation for pulmonary vein isolation in patients with atrial fibrillation: 2-year follow-up. J Cardiovasc Electrophysiol 2023; 34:546-555. [PMID: 36640429 DOI: 10.1111/jce.15809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 12/03/2022] [Accepted: 01/04/2023] [Indexed: 01/16/2023]
Abstract
INTRODUCTION The long-term efficacy of high-power (50 W) ablation guided by lesion size index (LSI-guided HP) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) remains undetermined. Our study sought to assess the clinical efficacy of LSI-guided HP ablation for PVI in patients with AF and explore the potential predictors associated with clinical outcomes. METHODS We consecutively included 186 patients with AF who underwent LSI-guided HP (50 W) ablation at Fuwai Hospital from June 2019 to October 2021. The target LSI values of 4.5-5.5 and 4.0-4.5 at the anterior and posterior walls, respectively, were used in our study. The baseline clinical characteristics, procedural and ablation data, and clinical outcomes were evaluated. The independent potential predictors associated with AF recurrence were further evaluated. RESULTS The incidence rate of first-pass PVI was 83.9% (156/186). A total of 11 883 lesions were analyzed, and compared with posterior walls of pulmonary veins, anterior walls had significantly lower mean contact force (8.2 ± 3.0 vs. 8.3 ± 2.3 g, p = .015), longer mean radiofrequency duration (16.9 ± 7.2 vs. 12.9 ± 4.5 s, p < .001) and higher mean LSI (4.8 ± 0.2 vs. 4.4 ± 0.2, p < .001). The overall incidence of periprocedural complications was 3.7%, and steam pops without pericardial effusion occurred in three patients (1.6%). During a mean follow-up of 24.0 ± 8.4 months, the overall AF recurrence-free survival was 87.1% after a single procedure. Patients with paroxysmal AF had a higher incidence of freedom from AF recurrence than those with persistent AF (91.2% vs. 80.8%, log-rank p = .034). Higher LSI (HR 0.50, p < .001) and paroxysmal AF (HR 0.39, p = .029) were significantly associated with decreased AF recurrence. By receiver operating characteristic analysis, the LSI of 4.7 and 4.3 for the anterior and posterior walls of the PVs had the highest predictive value for AF recurrence, respectively. CONCLUSION LSI-guided HP (50 W) ablation for PVI was an efficient and safe strategy and led to favorable single-procedure 2-year AF recurrence-free survival in patients with AF. Higher LSI and paroxysmal AF were independent predictors of decreased 2-year AF recurrence. The LSI of 4.7 for the anterior wall and 4.3 for the posterior wall of the PVs were the best cutoff values for predicting AF recurrence after LSI-guided HP ablation.
Collapse
Affiliation(s)
- Chi Cai
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jing Wang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hong-Xia Niu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jian-Min Chu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wei Hua
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Shu Zhang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yan Yao
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
3
|
Effect of Left Atrial Pulmonary Vein Angiography on Safety and Efficacy for High-Power, Short-Duration Pulmonary Vein Isolation in Patients with Atrial Fibrillation. J Clin Med 2023; 12:jcm12031094. [PMID: 36769742 PMCID: PMC9917939 DOI: 10.3390/jcm12031094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 01/25/2023] [Accepted: 01/28/2023] [Indexed: 02/02/2023] Open
Abstract
Imaging of pulmonary vein (PV) anatomy by angiography before pulmonary vein isolation (PVI) for atrial fibrillation (AF) has long been standard practice in many centers. Nowadays, very accurate anatomical maps can be generated by the use of high-resolution mapping catheters, and very effective ablation lesions can be generated by the use of the high-power, short-duration (HPSD) technique. In our center, PV angiography was routinely performed before PVI. However, since there is no clear evidence for this, we refrained from performing PV angiography. This study aimed to investigate whether PV angiography is still necessary when using high-resolution mapping catheters after ablation in the high-power, short-duration (HPSD) technique. A total of 139 consecutive patients with atrial fibrillation (66.25 ± 11.68 years old, 62.39% male) undergoing radiofrequency PVI were included in the study. Ablation was performed with the HPSD technique using a fixed protocol for energy delivery of 50 watts (contact force 3-20 g). We observed no significant effect on the efficacy, efficiency and complications of the ablation procedure if pulmonary vein angiography was omitted before HPSD PVI. Thus, using our protocol, it may be useful that PV angiography is avoided, especially in young patients and those with chronic renal disease.
Collapse
|
4
|
Weyand S, Beuter M, Heinzmann D, Seizer P. High-resolution mapping as an alternative for exit block testing in the presence of entrance block after high-power short-duration pulmonary vein isolation. Herzschrittmacherther Elektrophysiol 2022; 33:440-445. [PMID: 36083317 DOI: 10.1007/s00399-022-00895-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Accepted: 08/23/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND After pulmonary vein isolation (PVI) for atrial fibrillation (AF), it is common as an endpoint to demonstrate an exit block from the pulmonary veins (PVs) in addition to an entrance block into them. By using high-resolution mapping catheters, even very small signals can be detected. OBJECTIVES We investigated whether additional exit block testing is still necessary when using high-resolution mapping catheters after ablation in high-power short-duration (HPSD) techniques. MATERIALS AND METHODS Overall, 114 patients with AF (average age, 65.14 ± 11.3 years; 65.8% male) undergoing radiofrequency PVI were included in the study. Ablation was performed with the HPSD technique using a fixed protocol for energy delivery of 50 W (contact force 3-20 g). Entrance and exit block were tested with a high-resolution mapping catheter. Isolation of the PVs was achieved in all patients. RESULTS Capture of local PV tissue was demonstrated in all patients after PVI and exit block was present in all patients after entrance block was detected using a high-resolution mapping catheter. CONCLUSION Exit block testing in addition to the demonstration of an entrance block as an endpoint of PVI seems to have no additional benefit and might no longer be necessary when a high-resolution mapping catheter is used in HPSD ablation for PVI of AF.
Collapse
Affiliation(s)
- Sebastian Weyand
- Medizinische Klinik II - Kardiologie und Angiologie, Ostalb-Klinikum Aalen, Im Kälblesrain 1, 73430, Aalen, Germany.
| | - Matthias Beuter
- Medizinische Klinik II - Kardiologie und Angiologie, Ostalb-Klinikum Aalen, Im Kälblesrain 1, 73430, Aalen, Germany
| | - David Heinzmann
- Innere Medizin III - Kardiologie und Angiologie, Universitätsklinikum Tübingen, Tübingen, Germany
| | - Peter Seizer
- Medizinische Klinik II - Kardiologie und Angiologie, Ostalb-Klinikum Aalen, Im Kälblesrain 1, 73430, Aalen, Germany
| |
Collapse
|
5
|
Salló Z, Perge P, Balogi B, Orbán G, Piros K, Herczeg S, Nagy KV, Osztheimer I, Ábrahám P, Merkely B, Gellér L, Szegedi N. Impact of High-Power and Very High-Power Short-Duration Radiofrequency Ablation on Procedure Characteristics and First-Pass Isolation During Pulmonary Vein Isolation. Front Cardiovasc Med 2022; 9:935705. [PMID: 35872909 PMCID: PMC9300971 DOI: 10.3389/fcvm.2022.935705] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 06/20/2022] [Indexed: 11/13/2022] Open
Abstract
IntroductionHigh-power short-duration (HPSD) radiofrequency ablation has been proposed to produce rapid and effective lesions for pulmonary vein isolation (PVI). We aimed to evaluate the procedural characteristics and the first-pass isolation (FPI) rate of HPSD and very high-power short-duration (vHPSD) ablation compared to the low-power long-duration (LPLD) ablation technique.MethodsOne hundred fifty-six patients with atrial fibrillation (AF) were enrolled and assigned to LPLD, HPSD, or vHPSD PVI. The energy setting was 30, 50, and 90 W in the LPLD, HPSD, and vHPSD groups, respectively. In the vHPSD group, 90 W/4 s energy delivery was used in the QMODE+ setting. In the other groups, ablation index-guided applications were delivered with 30 W (LPLD) or 50 W (HPSD).ResultsBilateral PVI was achieved in all cases. Compared to the LPLD group, the HPSD and vHPSD groups had shorter procedure time [85 (75–101) min, 79 (65–91) min, and 70 (53–83) min], left atrial dwelling time [61 (55–70) min, 53 (41–56) min, and 45 (34–52) min], total RF time [1,567 (1,366–1,761) s, 1,398 (1,021–1,711) s, and 336 (247–386) s], but higher bilateral FPI rate (57, 78, and 80%) (all p-values < 0.01). The use of HPSD (OR = 2.72, 95% CI 1.15–6.44, p = 0.023) and vHPSD (OR = 2.90, 95% CI 1.24–6.44, p = 0.014) ablation techniques were associated with a higher probability of bilateral FPI. The 9-month AF-recurrence rate was lower in case of HPSD and vHPSD compared to LPLD ablation (10, 8, and 36%, p = 0.0001). Moreover, the presence of FPI was associated with a lower AF-recurrence rate at 9-month (OR = 0.09, 95% CI 0.04–0.24, p = 0.0001).ConclusionOur prospective, observational cohort study showed that both HPSD and vHPSD RF ablation shortens procedure and RF time and results in a higher rate of FPI compared to LPLD ablation. Moreover, the use of HPSD and vHPSD ablation increased the acute and mid-term success rate. No safety concerns were raised for HPSD or vHPSD ablation in our study.
Collapse
|