1
|
Ono M, Kageyama S, O’Leary N, El-Kurdi MS, Reinöhl J, Solien E, Bianco RW, Doss M, Meuris B, Virmani R, Cox M, Onuma Y, Serruys PW. 1-Year Patency of Biorestorative Polymeric Coronary Artery Bypass Grafts in an Ovine Model. JACC. BASIC TO TRANSLATIONAL SCIENCE 2022; 8:19-34. [PMID: 36777172 PMCID: PMC9911320 DOI: 10.1016/j.jacbts.2022.06.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 06/29/2022] [Accepted: 06/29/2022] [Indexed: 11/10/2022]
Abstract
Many attempts have been made to inhibit or counteract saphenous vein graft (SVG) failure modes; however, only external support for SVGs has gained momentum in clinical utility. This study revealed the feasibility of implantation, and showed good patency out to 12 months of the novel biorestorative graft, in a challenging ovine coronary artery bypass graft model. This finding could trigger the first-in-man trial of using the novel material instead of SVG. We believe that, eventually, this novel biorestorative bypass graft can be one of the options for coronary artery bypass graft patients who have difficulty harvesting SVG.
Collapse
Key Words
- CABG, coronary artery bypass grafting
- CPB, cardiopulmonary bypass
- IH, intimal hyperplasia
- LAD, left anterior descending artery
- OCT, optical coherence tomography
- QCA, quantitative coronary angiography
- QFR, quantitative flow ratio
- RVG, restorative vascular graft
- SVG, saphenous vein graft
- coronary artery bypass graft
- coronary artery disease
- coronary revascularization
- ePTFE, expanded polytetrafluoroethylene
- polymeric bypass graft
- preclinical model
- quantitative flow ratio
- restorative vascular graft
Collapse
Affiliation(s)
- Masafumi Ono
- Amsterdam Universitair Medische Centra, University of Amsterdam, Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam, the Netherlands
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Shigetaka Kageyama
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Neil O’Leary
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | | | | | - Eric Solien
- American Preclinical Services, LLC, Minneapolis, Minnesota, USA
| | - Richard W. Bianco
- Experimental Surgical Services, University of Minnesota, Minneapolis, Minnesota, USA
| | - Mirko Doss
- Department of Cardiac Surgery, Helios Clinic, Siegburg, Germany
| | - Bart Meuris
- Department of Cardiac Surgery, University Hospital Leuven, Leuven, Belgium
| | - Renu Virmani
- CVPath Institute, Inc, Gaithersburg, Maryland, USA
| | | | - Yoshinobu Onuma
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
| | - Patrick W. Serruys
- Department of Cardiology, National University of Ireland, Galway (NUIG), Galway, Ireland
- NHLI, Imperial College London, London, United Kingdom
- Address for correspondence: Dr Patrick W. Serruys, National University of Ireland, Galway (NUIG), University Road, Galway H91 TK33, Ireland.
| |
Collapse
|
2
|
Design and Characterization of a Fluidic Device for the Evaluation of SIS-Based Vascular Grafts. Processes (Basel) 2020. [DOI: 10.3390/pr8091198] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Currently available small diameter vascular conduits present several long-term limitations, which has prevented their full clinical implementation. Commercially available vascular grafts show no regenerative capabilities and eventually require surgical replacement; therefore, it is of great interest to develop alternative regenerative vascular grafts (RVG). Decellularized Small Intestinal Submucosa (SIS) is an attractive material for RVG, however, the evaluation of the performance of these grafts is challenging due to the absence of devices that mimic the conditions found in vivo. Thereby, the objective of this study is to design, manufacture and validate in silico and in vitro, a novel fluidic system for the evaluation of human umbilical vein endothelial cells (HUVECs) proliferation on SIS-based RVG under dynamical conditions. Our perfusion and rotational fluidic system was designed in Autodesk Inventor 2018. In silico Computational Fluid Dynamics (CFD) validation of the system was carried out using Ansys Fluent software from ANSYS, Inc for dynamical conditions of a pulsatile pressure function measured experimentally over a rigid wall model. Mechanical and biological parameters such as flow regime, pressure gradient, wall shear stress (WSS), sterility and indirect cell viability (MTT assay) were also evaluated. Cell adhesion was confirmed by SEM imaging. The fluid flow regime within the system remains laminar. The system maintained sterility and showed low cytotoxicity levels. HUVECs were successfully cultured on SIS-based RVG under both perfusion and rotation conditions. In silico analysis agreed well with our experimental and theoretical results, and with recent in vitro and in vivo reports for WSS. The system presented is a tool for evaluating RVG and represents an alternative to develop new methods and protocols for a more comprehensive study of regenerative cardiovascular devices.
Collapse
|
3
|
El-Kurdi M, Soletti L, McGrath J, Linhares S, Rousselle S, Greisler H, Edelman E, Schoen FJ. Functional remodeling of an electrospun polydimethylsiloxane-based polyether urethane external vein graft support device in an ovine model. J Biomed Mater Res A 2019; 107:2135-2149. [PMID: 31094084 PMCID: PMC6689261 DOI: 10.1002/jbm.a.36724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 02/13/2019] [Accepted: 05/07/2019] [Indexed: 11/07/2022]
Abstract
Saphenous vein graft (SVG) failure rates are unacceptably high, and external mechanical support may improve patency. We studied the histologic remodeling of a conformal, electrospun, polydimethylsiloxane-based polyether urethane external support device for SVGs and evaluated graft structural evolution in adult sheep to 2 years. All sheep (N = 19) survived to their intended timepoints, and angiography showed device-treated SVG geometric stability over time (30, 90, 180, 365, or 730 days), with an aggregated graft patency rate of 92%. There was minimal inflammation associated with the device material at all timepoints. By 180 days, treated SVG remodeling was characterized by minimal/nonprogressive intimal hyperplasia; polymer fragmentation and integration; as well as the development of a neointima, and a confluent endothelium. By 1-year, the graft developed a media-like layer by remodeling the neointima, and elastic fibers formed well-defined structures that subtended the neo-medial layer of the remodeled SVG. Immunohistochemistry showed that this neo-media was populated with smooth muscle cells, and the intima was lined with endothelial cells. These data suggest that treated SVGs were structurally remodeled by 180 days, and developed arterial-like features by 1 year, which continued to mature to 2 years. Device-treated SVGs remodeled into arterial-like conduits with stable long-term performance as arterial grafts in adult sheep.
Collapse
Affiliation(s)
| | | | | | | | | | - Howard Greisler
- Loyola University, Maywood, IL and Hines VA Hospital, Hines, IL
| | - Elazer Edelman
- Massachusetts Institute of Technology, Cambridge, MA, Harvard Medical School, Boston, MA, Brigham and Women’s Hospital, Boston, MA
| | - Frederick J. Schoen
- Brigham and Women’s Hospital, Boston, MA, and Harvard Medical School, Boston, MA
| |
Collapse
|
4
|
Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, Dillon J, Yakub A, Dimon Z, Gurny R, Walpoth BH, Moeller M. Effect of implantation site on outcome of tissue-engineered vascular grafts. Eur J Pharm Biopharm 2019; 139:272-278. [DOI: 10.1016/j.ejpb.2019.04.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 04/15/2019] [Accepted: 04/16/2019] [Indexed: 01/31/2023]
|
5
|
Gregory EK, Vercammen JM, Flynn ME, Kibbe MR. Establishment of a rat and guinea pig aortic interposition graft model reveals model-specific patterns of intimal hyperplasia. J Vasc Surg 2016; 64:1835-1846.e1. [PMID: 26781075 DOI: 10.1016/j.jvs.2015.09.052] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Accepted: 09/18/2015] [Indexed: 11/29/2022]
Abstract
OBJECTIVE Although the aortic interposition bypass model has been widely used to evaluate biomaterials for bypass grafting, there is no comprehensive description of the procedure or of the distribution of intimal hyperplasia that results. The objectives of this study were to (1) review and summarize approaches of aortic interposition grafting in animal models, (2) determine the pertinent anatomy for this procedure, (3) validate this model in the rat and guinea pig, and (4) compare the distribution of intimal hyperplasia that develops in each species. METHODS A literature search was performed in PubMed from 1980 to the present to analyze the use of anesthesia, anticoagulation, antiplatelet agents, graft material, suture, and anastomotic techniques. Using 10-week-old male Sprague-Dawley rats and Hartley guinea pigs, we established pertinent aortic anatomy, developed comparable models, and assessed complications for each model. At 30 days, the graft and associated aorta were explanted, intimal formation was assessed morphometrically, and cellularity was assessed via nuclear counting. RESULTS We reviewed 30 articles and summarized the pertinent procedural findings. Upon establishing both animal models, key anatomic differences between the species that affect this model were noted. Guinea pigs have a much larger cecum, increased retroperitoneal fat, and lack the iliolumbar vessels compared with the rat. Surgical outcomes for the rat model included a 53% technical success rate and a 32% technical error rate. Surgical outcomes for the guinea pig model included a 69% technical success rate and a 31% technical error rate. These two species demonstrated unique distribution of intimal hyperplasia at 30 days. Intimal hyperplasia in the rat model was greatest at two areas, the proximal graft (5400 μm2; P < .001) and distal graft (2800 μm2; P < .04), whereas the guinea pig model developed similar intimal hyperplasia throughout the graft (4500-5100 μm2; P < .01). CONCLUSIONS In this report, we summarize the literature on the aortic interposition graft model, present a detailed description of the anatomy and aortic interposition graft procedure in the rat and guinea pig, and describe a unique distribution of intimal formation that results in both species. This information will be helpful when designing studies to evaluate novel graft materials in the future.
Collapse
Affiliation(s)
- Elaine K Gregory
- Division of Vascular Surgery, Feinberg School of Medicine, and Simpson Querrey Institute for Bionanotechnology, Northwestern University, Chicago, Ill
| | - Janet M Vercammen
- Division of Vascular Surgery, Feinberg School of Medicine, and Simpson Querrey Institute for Bionanotechnology, Northwestern University, Chicago, Ill
| | - Megan E Flynn
- Division of Vascular Surgery, Feinberg School of Medicine, and Simpson Querrey Institute for Bionanotechnology, Northwestern University, Chicago, Ill
| | - Melina R Kibbe
- Division of Vascular Surgery, Feinberg School of Medicine, and Simpson Querrey Institute for Bionanotechnology, Northwestern University, Chicago, Ill; Section of Vascular Surgery, Jesse Brown Veterans Affairs Medical Center, Chicago, Ill.
| |
Collapse
|
6
|
Koens MJW, Krasznai AG, Hanssen AEJ, Hendriks T, Praster R, Daamen WF, van der Vliet JA, van Kuppevelt TH. Vascular replacement using a layered elastin-collagen vascular graft in a porcine model: one week patency versus one month occlusion. Organogenesis 2015; 11:105-21. [PMID: 26060888 DOI: 10.1080/15476278.2015.1038448] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
A persistent clinical demand exists for a suitable arterial prosthesis. In this study, a vascular conduit mimicking the native 3-layered artery, and constructed from the extracellular matrix proteins type I collagen and elastin, was evaluated for its performance as a blood vessel equivalent. A tubular 3-layered graft (elastin-collagen-collagen) was prepared using highly purified type I collagen fibrils and elastin fibers, resembling the 3-layered native blood vessel architecture. The vascular graft was crosslinked and heparinised (37 ± 4 μg heparin/mg graft), and evaluated as a vascular graft using a porcine bilateral iliac artery model. An intra-animal comparison with clinically-used heparinised ePTFE (Propaten®) was made. Analyses included biochemical characterization, duplex scanning, (immuno)histochemistry and scanning electron microscopy. The tubular graft was easy to handle with adequate suturability. Implantation resulted in pulsating grafts without leakage. One week after implantation, both ePTFE and the natural acellular graft had 100% patencies on duplex scanning. Grafts were partially endothelialised (Von Willebrand-positive endothelium with a laminin-positive basal membrane layer). After one month, layered thrombi were found in the natural (4/4) and ePTFE graft (1/4), resulting in occlusion which in case of the natural graft is likely due to the porosity of the inner elastin layer. In vivo application of a molecularly-defined tubular graft, based on nature's matrix proteins, for vascular surgery is feasible.
Collapse
Affiliation(s)
- M J W Koens
- a Department of Biochemistry ; NCMLS; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands.,b Department of Urology ; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - A G Krasznai
- c Department of Surgery ; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - A E J Hanssen
- d Central Animal Laboratory; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - T Hendriks
- c Department of Surgery ; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - R Praster
- c Department of Surgery ; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - W F Daamen
- a Department of Biochemistry ; NCMLS; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - J A van der Vliet
- c Department of Surgery ; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| | - T H van Kuppevelt
- a Department of Biochemistry ; NCMLS; Radboud University Medical Centre ; Nijmegen , HB , The Netherlands
| |
Collapse
|
7
|
Shu C, Guo Y, Zhou X, Wan H, Yan J, Yuan L. Effect of postoperative fractionated radiotherapy on canine ePTFE graft neointima and anastomotic stoma healing: A preliminary experimental study. Asian J Surg 2011; 34:121-7. [DOI: 10.1016/j.asjsur.2011.08.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2011] [Revised: 07/03/2011] [Accepted: 07/18/2011] [Indexed: 10/16/2022] Open
|
8
|
Zhengbang W, Haolin T, Junsheng L, Mu P. Morphology change of biaxially oriented polytetrafluoroethylene membranes caused by solvent soakage. J Appl Polym Sci 2011. [DOI: 10.1002/app.33670] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|