1
|
Wu YF, Shen CL, Huang WH, Chu SC, Li CC, Liu CZ, Wang TF. Improving platelet function following prophylactic platelet transfusion in patients with hematological malignancies. Int J Lab Hematol 2024; 46:722-730. [PMID: 38682289 DOI: 10.1111/ijlh.14283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 04/01/2024] [Indexed: 05/01/2024]
Abstract
INTRODUCTION Platelet transfusion is a standard treatment to prevent bleeding in patients with hematological malignancies. Although transfusions can improve platelet count, their impact on platelet function remains controversial. METHODS We conducted flow cytometry to assess platelet function before and after transfusion and performed subgroup analyses to examine differences based on blood type, corrected count increment (CCI), and platelet microparticles. RESULTS Overall, 50 patients who received prophylactic platelet transfusion were enrolled. CD42b expression increased, whereas CD41 expression decreased after transfusion. Apheresis platelets exhibited the lowest expression of PAC-1 and P-selectin when exposed to agonist stimulations. PAC-1 expression increased under high adenosine diphosphate (ADP) stimulation, while P-selectin expression increased under both high ADP and thrombin receptor-activating peptide stimulation. In the subgroup analysis, patients with a CCI >4500 and those with the same blood types exhibited a more significant increase in PAC-1 and P-selectin expression under agonist stimulation. When comparing apheresis platelets collected on different days, only the percentage of platelet-derived microparticles showed a significant increase. CONCLUSION Prophylactic transfusion improved platelet function. Platelet function significantly improved in patients with a CCI >4500, those with the same blood types as that of apheresis platelets, or those with platelet-derived microparticle levels <4.7%. No significant improvement in platelet function was noted after the transfusion of different blood types with acceptable compatibility or the transfusion of incompatible blood types. Our results suggest that transfusing platelets with the same blood type remains the optimal choice.
Collapse
Affiliation(s)
- Yi-Feng Wu
- Department of Hematology and Oncology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- College of Medicine, Tzu-Chi University, Hualien, Taiwan
- Ph.D. Program in Pharmacology and Toxicology, Tzu Chi University, Hualien, Taiwan
| | - Chih-Lung Shen
- Department of Hematology and Oncology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
| | - Wei-Han Huang
- Department of Hematology and Oncology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- Department of Clinical Pathology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
| | - Sung-Chao Chu
- Department of Hematology and Oncology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- College of Medicine, Tzu-Chi University, Hualien, Taiwan
| | - Chi-Cheng Li
- Department of Hematology and Oncology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- Center of Stem Cell & Precision Medicine, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
| | - Chao-Zong Liu
- Department of Pharmacology, School of Medicine, Tzu Chi University, Hualien, Taiwan
| | - Tso-Fu Wang
- Department of Hematology and Oncology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
- College of Medicine, Tzu-Chi University, Hualien, Taiwan
| |
Collapse
|
2
|
Nash J, Davies A, Saunders CV, George CE, Williams JO, James PE. Quantitative increases of extracellular vesicles in prolonged cold storage of platelets increases the potential to enhance fibrin clot formation. Transfus Med 2023; 33:467-477. [PMID: 37553476 DOI: 10.1111/tme.12989] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 07/04/2023] [Accepted: 07/26/2023] [Indexed: 08/10/2023]
Abstract
BACKGROUND Platelet derived extracellular vesicles (EVs) display a pro-coagulant phenotype and are generated throughout platelet concentrate (PC) storage. Cold storage (CS) of PCs is thought to provide a superior haemostatic advantage over room temperature (RT) storage and could prolong the storage time. However, the effect of storage conditions on EV generation and PC function is unknown. We investigated EV production under CS and RT conditions and assessed whether these EVs exhibited a more pro-coagulant phenotype in model experiments. MATERIALS AND METHODS Buffy-coat-derived PCs in a platelet additive solution (PAS) to plasma ratio of approximately 65:35 were stored at RT (22 ± 2°C) or CS (4 ± 2°C) for a prolonged storage duration of 20 days. Impedance aggregometry assessed platelet function. EVs were isolated throughout storage and quantified using nanoparticle tracking analysis. EVs were applied to a coagulation assay to assess the impact on fibrin clot formation and lysis. RESULTS CS produced significantly larger EVs from day 4 onwards. EV concentration was significantly increased in CS compared to RT from day 15. EVs, regardless of storage, significantly reduced time to clot formation and maximum optical density measured compared to the no EV control. Clot formation was proportionate to the number of EV applied but was not statistically different across storage conditions when corrected for EV number. CONCLUSION EVs in CS and RT units showed similar clot formation capacity. However, the higher number of larger EVs generated in CS compared to RT suggests PC units derived from CS conditions may overall exhibit a haemostatically superior capacity compared to RT storage.
Collapse
Affiliation(s)
- J Nash
- Cardiff School of Sport and Health Sciences, Cardiff Metropolitan University, Cardiff, UK
- Component Development and Research Laboratory, Welsh Blood Service, Pontyclun, UK
| | - A Davies
- Cardiff School of Sport and Health Sciences, Cardiff Metropolitan University, Cardiff, UK
| | - C V Saunders
- Component Development and Research Laboratory, Welsh Blood Service, Pontyclun, UK
| | - C E George
- Component Development and Research Laboratory, Welsh Blood Service, Pontyclun, UK
| | - J O Williams
- Cardiff School of Sport and Health Sciences, Cardiff Metropolitan University, Cardiff, UK
| | - P E James
- Cardiff School of Sport and Health Sciences, Cardiff Metropolitan University, Cardiff, UK
| |
Collapse
|
3
|
Elvira L, Fernández A, León L, Ibáñez A, Parrilla M, Martínez Ó, Jiménez J. Evaluation of the Cell Concentration in Suspensions of Human Leukocytes by Ultrasound Imaging: The Influence of Size Dispersion and Cell Type. SENSORS (BASEL, SWITZERLAND) 2023; 23:977. [PMID: 36679773 PMCID: PMC9866977 DOI: 10.3390/s23020977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 06/17/2023]
Abstract
This work focuses on the use of ultrasound imaging to evaluate the cell concentration of dilute leukocyte suspensions in the range of 10-3000 cells/µL. First, numerical simulations were used to study the influence of the size dispersion and the leukocyte type on the performance of the concentration estimation algorithms, which were developed in previous works assuming single-sized scatterers. From this analysis, corrections to the mentioned algorithms were proposed and then the performance of these corrections was evaluated from experiments. For this, ultrasound images were captured from suspensions of lymphocytes, granulocytes, and their mixtures. These images were obtained using a 20 MHz single-channel scanning system. Results confirmed that concentration estimates provided by conventional algorithms were affected by the size dispersion of cells, leading to a remarkable underestimation of results. The proposed correction to compensate for cell size dispersion obtained from simulations improved the concentration estimation of these algorithms, for the cell suspensions tested, approaching the results to the reference optical characterization. Moreover, it was shown that these models provided a total leukocyte concentration from the ultrasound images which was independent of the relative populations of different white blood cell types.
Collapse
Affiliation(s)
- Luis Elvira
- Instituto de Tecnologías Físicas y de la Información (CSIC), Serrano 144, 28006 Madrid, Spain
| | - Alba Fernández
- Instituto de Tecnologías Físicas y de la Información (CSIC), Serrano 144, 28006 Madrid, Spain
| | - Lucía León
- Instituto de Tecnologías Físicas y de la Información (CSIC), Serrano 144, 28006 Madrid, Spain
| | - Alberto Ibáñez
- Instituto de Tecnologías Físicas y de la Información (CSIC), Serrano 144, 28006 Madrid, Spain
| | - Montserrat Parrilla
- Instituto de Tecnologías Físicas y de la Información (CSIC), Serrano 144, 28006 Madrid, Spain
| | - Óscar Martínez
- Instituto de Tecnologías Físicas y de la Información (CSIC), Serrano 144, 28006 Madrid, Spain
| | - Javier Jiménez
- Newborn Solutions, Baldiri Reixac, 4-12 i 15, 08028 Barcelona, Spain
| |
Collapse
|
4
|
Abstract
AbstractThe characterization of platelet concentrates (PCs) in transfusion medicine has been performed with different analytical methods and platelet lesions (from biochemistry to cell biology) have been documented. In routine quality assessment and validation of manufacturing processes of PCs for transfusion purposes, only basic parameters are monitored and the platelet functions are not included. However, PCs undergo several manipulations during the processing and the basic parameters do not provide sensitive analyses to properly picture out the impact of the blood component preparation and storage on platelets. To improve the transfusion supply chain and the platelet functionalities, additional parameters should be used. The present short review will focus on the different techniques to monitor ex vivo platelet lesions from phenotype characterization to advanced omic analyses. Then, the opportunities to use these methods in quality control, process validation, development, and research will be discussed. Functional markers should be considered because they would be an advantage for the future developments in transfusion medicine.
Collapse
|
5
|
Millar D, Hayes C, Jones J, Klapper E, Kniep JN, Luu HS, Noland DK, Petitti L, Poisson JL, Spaepen E, Ye Z, Maurer-Spurej E. Comparison of the platelet activation status of single-donor platelets obtained with two different cell separator technologies. Transfusion 2020; 60:2067-2078. [PMID: 32729161 DOI: 10.1111/trf.15934] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 05/06/2020] [Accepted: 05/24/2020] [Indexed: 12/16/2022]
Abstract
BACKGROUND The microparticle content (MP%) of apheresis platelets-a marker of platelet activation-is influenced by donor factors and by external stressors during collection and storage. This study assessed the impact of apheresis technology and other factors on the activation status (MP%) of single-donor apheresis platelets. STUDY DESIGN AND METHODS Data from six US hospitals that screened platelets by measuring MP% through dynamic light scattering (ThromboLUX) were retrospectively analyzed. Relative risks (RRs) were derived from univariate and multivariable regression models, with activation rate (MP% ≥15% for plasma-stored platelets; ≥10% for platelet additive solution [PAS]-stored platelets) and MP% as outcomes. Apheresis platform (Trima Accel vs Amicus), storage medium (plasma vs PAS), pathogen reduction, storage time, and testing location were used as predictors. RESULTS Data were obtained from 7511 platelet units collected using Trima (from 16 suppliers, all stored in plasma, 20.0% were pathogen-reduced) and 2456 collected using Amicus (from four different collection facilities of one supplier, 65.0% plasma-stored, 35.0% PAS-stored, none pathogen-reduced). Overall, 30.0% of Trima platelets were activated compared to 45.6% of Amicus platelets (P < .0001). Multivariable analysis identified apheresis platform as significantly associated with platelet activation, with a lower activation rate for Trima than Amicus (RR: 0.641, 95% confidence interval [CI]: 0.578; 0.711, P < .0001) and a 6.901% (95% CI: 5.926; 7.876, P < .0001) absolute reduction in MP%, when adjusting for the other variables. CONCLUSION Trima-collected platelets were significantly less likely to be activated than Amicus-collected platelets, irrespective of the storage medium, the use of pathogen reduction, storage time, and testing site.
Collapse
Affiliation(s)
- Daniel Millar
- Department of Integrated Engineering, University of British Columbia and MistyWest Research and Engineering Lab, Vancouver, British Columbia, Canada
| | - Chelsea Hayes
- Department of Pathology, Division of Transfusion Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Jessica Jones
- Department of Pathology & Laboratory Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Ellen Klapper
- Department of Pathology, Division of Transfusion Medicine, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Joel N Kniep
- Department of Pathology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Hung S Luu
- Department of Pathology, University of Texas Southwestern Medical Center and Children's Health, Dallas, Texas, USA
| | - Daniel K Noland
- Department of Pathology, University of Texas Southwestern Medical Center and Children's Health, Dallas, Texas, USA
| | | | | | | | - Zhan Ye
- Department of Pathology & Laboratory Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Elisabeth Maurer-Spurej
- Department of Pathology and Laboratory Medicine and Centre for Blood Research and Canadian Blood Services, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
6
|
Gandham S, Su X, Wood J, Nocera AL, Alli SC, Milane L, Zimmerman A, Amiji M, Ivanov AR. Technologies and Standardization in Research on Extracellular Vesicles. Trends Biotechnol 2020; 38:1066-1098. [PMID: 32564882 PMCID: PMC7302792 DOI: 10.1016/j.tibtech.2020.05.012] [Citation(s) in RCA: 241] [Impact Index Per Article: 60.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 05/20/2020] [Accepted: 05/26/2020] [Indexed: 12/14/2022]
Abstract
Extracellular vesicles (EVs) are phospholipid bilayer membrane-enclosed structures containing RNAs, proteins, lipids, metabolites, and other molecules, secreted by various cells into physiological fluids. EV-mediated transfer of biomolecules is a critical component of a variety of physiological and pathological processes. Potential applications of EVs in novel diagnostic and therapeutic strategies have brought increasing attention. However, EV research remains highly challenging due to the inherently complex biogenesis of EVs and their vast heterogeneity in size, composition, and origin. There is a need for the establishment of standardized methods that address EV heterogeneity and sources of pre-analytical and analytical variability in EV studies. Here, we review technologies developed for EV isolation and characterization and discuss paths toward standardization in EV research.
Collapse
Affiliation(s)
- Srujan Gandham
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA
| | - Xianyi Su
- Department of Chemistry and Chemical Biology, Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA 02115, USA
| | - Jacqueline Wood
- Department of Chemistry and Chemical Biology, Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA 02115, USA
| | - Angela L Nocera
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA
| | - Sarath Chandra Alli
- Department of Chemistry and Chemical Biology, Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA 02115, USA; Department of Bioengineering, Northeastern University, Boston, MA 02115, USA
| | - Lara Milane
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA
| | - Alan Zimmerman
- Department of Chemistry and Chemical Biology, Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA 02115, USA
| | - Mansoor Amiji
- Department of Pharmaceutical Sciences, School of Pharmacy, Northeastern University, Boston, MA 02115, USA
| | - Alexander R Ivanov
- Department of Chemistry and Chemical Biology, Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA 02115, USA.
| |
Collapse
|
7
|
Noulsri E. Quantitation of Cell-Derived Microparticles in Blood Products and Its Potential Applications in Transfusion Laboratories. Lab Med 2020; 51:452-459. [DOI: 10.1093/labmed/lmz100] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Abstract
Cell-derived microparticles (MPs) are small fragments released from various cells when they are activated or undergo apoptosis. In the field of transfusion medicine, a number of studies have documented increased levels of MPs in blood products, which have been associated with multiple factors, including donor variability, blood component processing, and storage. In addition, transfusions that contain high levels of MPs are linked to posttransfusion complications. Considering the clinical importance of MP levels, transfusion laboratories should routinely screen blood products for them. However, this practice is not yet applied routinely, perhaps in part because of a lack of understanding of how to apply MP data to transfusion medicine. We describe the methods used to quantitate MPs in blood components and discuss the application of these quantitative data in routine transfusion laboratories in order to manage quality, improve the outcomes of transfusions, and minimize their complications.
Collapse
Affiliation(s)
- Egarit Noulsri
- Research Division, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
8
|
Acker JP, Almizraq RJ, Millar D, Maurer-Spurej E. Screening of red blood cells for extracellular vesicle content as a product quality indicator. Transfusion 2018; 58:2217-2226. [PMID: 30168148 DOI: 10.1111/trf.14782] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 04/23/2018] [Accepted: 04/23/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND The controversy around the quality and clinical impact of stored and differentially manufactured red cell concentrates (RCCs) from different donor groups is ongoing. Current studies are limited by the lack of quality measures suitable for routine screening of RCCs. As extracellular vesicles (EVs) are markers of cellular activation or degradation, this study investigated the utility of EV screening to characterize the effects of RBCs production methods and storage. STUDY DESIGN AND METHODS RCCs were prepared by whole blood filtration or red blood cell (RBC) filtration methods, centrifuged to prepare a supernatant, and tested for EV content (dynamic light scattering or tunable resistive pulse-sensing techniques), hemolysis, ATP, and RBC deformability on Days 7, 21, and 42 of storage. To simulate nondestructive quality control (QC) testing, 1 RBC unit was tested in parallel with six 10-mL aliquots that were stored in small-volume containers. RESULTS EV content showed a linear increase with storage time (p < 0.001) and correlated with supernatant hemoglobin and inversely with ATP or RBC deformability. The method of component manufacturing influenced the characteristics of the EVs during storage. A strong correlation between both EV testing methods' measure of total EV was observed. EV content in the six aliquots were consistent at each time point but statistically higher than in the original RCCs on and after 21 days of storage. CONCLUSIONS EV content correlates with measures of hemolysis and other RBC quality indicators and could be implemented as a routine screening tool for nondestructive QC testing of RCCs.
Collapse
Affiliation(s)
- Jason P Acker
- Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta.,Centre for Innovation, Canadian Blood Services, Edmonton, Alberta
| | | | - Daniel Millar
- LightIntegra Technology, Inc., Vancouver, British Columbia, Canada
| | - Elisabeth Maurer-Spurej
- LightIntegra Technology, Inc., Vancouver, British Columbia, Canada.,Department of Pathology and Laboratory Medicine, Vancouver, British Columbia, Canada.,Centre for Blood Research, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
9
|
Millar D, Murphy L, Labrie A, Maurer-Spurej E. Routine Screening Method for Microparticles in Platelet Transfusions. J Vis Exp 2018. [PMID: 29443045 PMCID: PMC5912315 DOI: 10.3791/56893] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Platelet inventory management based on screening microparticle content in platelet concentrates is a new quality improvement initiative for hospital blood banks. Cells fragment off microparticles (MP) when they are stressed. Blood and blood components may contain cellular fragments from a variety of cells, most notably from activated platelets. When performing their roles as innate immune cells and major players in coagulation and hemostasis, platelets change shape and generate microparticles. With dynamic light scattering (DLS)-based microparticle detection, it is possible to differentiate activated (high microparticle) from non-activated (low microparticle) platelets in transfusions, and optimize the use of this scarce blood product. Previous research suggests that providing non-activated platelets for prophylactic use in hematology-oncology patients could reduce their risk of becoming refractory and improve patient care. The goal of this screening method is to routinely differentiate activated from non-activated platelets. The method described here outlines the steps to be performed for routine platelet inventory management in a hospital blood bank: obtaining a sample from a platelet transfusion, loading the sample into the capillary for DLS measurement, performing the DLS test to identify microparticles, and using the reported microparticle content to identify activated platelets.
Collapse
Affiliation(s)
| | - Larry Murphy
- Quality Engineering & Regulatory, LightIntegra Technology Inc
| | | | - Elisabeth Maurer-Spurej
- Research & Development, LightIntegra Technology Inc.; Department of Pathology and Laboratory Medicine; Center for Blood Research, University of British Columbia; Canadian Blood Services;
| |
Collapse
|
10
|
Black A, Orsó E, Kelsch R, Pereira M, Kamhieh-Milz J, Salama A, Fischer MB, Meyer E, Frey BM, Schmitz G. Analysis of platelet-derived extracellular vesicles in plateletpheresis concentrates: a multicenter study. Transfusion 2017; 57:1459-1469. [DOI: 10.1111/trf.14109] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Revised: 02/06/2017] [Accepted: 02/06/2017] [Indexed: 12/19/2022]
Affiliation(s)
- Anne Black
- Institute for Clinical Chemistry and Laboratory Medicine; University Hospital of Regensburg; Regensburg Germany
| | - Evelyn Orsó
- Institute for Clinical Chemistry and Laboratory Medicine; University Hospital of Regensburg; Regensburg Germany
| | - Reinhard Kelsch
- Institute of Transfusion Medicine and Transplantation Immunology, University Hospital Muenster; Muenster Germany
| | - Melanie Pereira
- Institute of Transfusion Medicine, Charité University Medical Centre; Berlin Germany
| | - Julian Kamhieh-Milz
- Institute of Transfusion Medicine, Charité University Medical Centre; Berlin Germany
| | - Abdulgabar Salama
- Institute of Transfusion Medicine, Charité University Medical Centre; Berlin Germany
| | - Michael B. Fischer
- Department for Health Sciences and Biomedicine; Danube University Krems; Krems Austria
| | - Eduardo Meyer
- Regional Blood Transfusion Service Zurich SRK; Zurich Switzerland
| | - Beat M. Frey
- Regional Blood Transfusion Service Zurich SRK; Zurich Switzerland
| | - Gerd Schmitz
- Institute for Clinical Chemistry and Laboratory Medicine; University Hospital of Regensburg; Regensburg Germany
| |
Collapse
|
11
|
Kanzler P, Mahoney A, Leitner G, Witt V, Maurer-Spurej E. Microparticle detection to guide platelet management for the reduction of platelet refractoriness in children – A study proposal. Transfus Apher Sci 2017; 56:39-44. [DOI: 10.1016/j.transci.2016.12.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
12
|
Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? JOURNAL OF BLOOD TRANSFUSION 2016; 2016:6140239. [PMID: 28053805 PMCID: PMC5178367 DOI: 10.1155/2016/6140239] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 10/27/2016] [Accepted: 11/06/2016] [Indexed: 12/22/2022]
Abstract
High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency and stability of the manufacturing process. Assuming that fresh product is always superior to aged product, maintaining in vitro characteristics should preserve high quality. However, despite the highest in vitro quality standards, platelets often fail in vivo. This suggests we may need different quality measures to predict platelet performance after transfusion. Adding to this complexity, platelets are used clinically for very different purposes: platelets need to circulate when given as prophylaxis to cancer patients and to stop bleeding when given to surgery or trauma patients. In addition, the emerging application of platelet-rich plasma injections exploits the immunological functions of platelets. Requirements for quality of platelets intended to prevent bleeding, stop bleeding, or promote wound healing are potentially very different. Can a single measurable characteristic describe platelet quality for all uses? Here we present microparticle measurement in platelet samples, and its potential to become the universal quality characteristic for platelet production, storage, viability, function, and compatibility.
Collapse
|
13
|
Arbaeen AF, Serrano K, Levin E, Devine DV. Platelet concentrate functionality assessed by thromboelastography or rotational thromboelastometry. Transfusion 2016; 56:2790-2798. [DOI: 10.1111/trf.13760] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 06/25/2016] [Accepted: 07/03/2016] [Indexed: 12/22/2022]
Affiliation(s)
- Ahmad F. Arbaeen
- Department of Pathology and Laboratory Medicine and Centre for Blood Research; University of British Columbia; Vancouver, British Columbia Canada
- Faculty of Applied Medical Sciences; Department Laboratory Medicine, Umm al-Qura University, Makkah Al Mukarramah; Saudi Arabia
| | - Katherine Serrano
- Department of Pathology and Laboratory Medicine and Centre for Blood Research; University of British Columbia; Vancouver, British Columbia Canada
- Canadian Blood Services Centre for Innovation; Vancouver British Columbia Canada
| | - Elena Levin
- Department of Pathology and Laboratory Medicine and Centre for Blood Research; University of British Columbia; Vancouver, British Columbia Canada
- Canadian Blood Services Centre for Innovation; Vancouver British Columbia Canada
| | - Dana V. Devine
- Department of Pathology and Laboratory Medicine and Centre for Blood Research; University of British Columbia; Vancouver, British Columbia Canada
- Canadian Blood Services Centre for Innovation; Vancouver British Columbia Canada
| |
Collapse
|
14
|
Maurer-Spurej E, Larsen R, Labrie A, Heaton A, Chipperfield K. Microparticle content of platelet concentrates is predicted by donor microparticles and is altered by production methods and stress. Transfus Apher Sci 2016; 55:35-43. [DOI: 10.1016/j.transci.2016.07.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
15
|
Taha M, Kalab M, Yi QL, Maurer E, Jenkins C, Schubert P, Ramirez-Arcos S. Bacterial survival and distribution during buffy coat platelet production. Vox Sang 2016; 111:333-340. [PMID: 27432557 DOI: 10.1111/vox.12427] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 05/09/2016] [Accepted: 06/03/2016] [Indexed: 01/11/2023]
Abstract
BACKGROUND AND OBJECTIVES At Canadian Blood Services, buffy coat (BC) platelet concentrates (BC-PCs) show a generally lower bacterial contamination rate than apheresis PCs. This study investigated whether the PC production method contributes to this observation. MATERIALS AND METHODS Whole blood (WB) inoculated with eight bacterial strains was processed using the BC method. Bacteria were enumerated throughout BC-PC production and subsequent PC storage. Endotoxin production and bacterial adhesion to PC bags were evaluated during PC storage. PC quality was monitored by CD62P expression (flow cytometry) and changes in dynamic light scattering (ThromboLUX® ). RESULTS During overnight WB hold, Staphylococcus epidermidis titres remained unchanged, commercial Escherichia coli and Klebsiella pneumoniae were eliminated and the remaining organisms proliferated to high concentrations. Through BC-PC production, bacteria segregated preferentially towards the cellular fractions compared to plasma (P < 0·05). During PC storage, most bacteria adhered to the PC bags and Gram negatives produced clinically significant endotoxin levels. Changes in CD62P expression or ThromboLUX scoring did not consistently reflect bacterial contamination in BC-PCs. CONCLUSION WB hold during BC-PC production does not have a broad-spectrum bactericidal effect, and therefore, other factors contribute to low rates of contamination in BC-PCs.
Collapse
Affiliation(s)
- M Taha
- Canadian Blood Services, Ottawa, ON, Canada
| | - M Kalab
- Agriculture and Agri-Food Canada, Ottawa, ON, Canada
| | - Q-L Yi
- Canadian Blood Services, Ottawa, ON, Canada
| | - E Maurer
- LightIntegra, Vancouver, BC, Canada
| | - C Jenkins
- Canadian Blood Services, Ottawa, ON, Canada
| | - P Schubert
- Canadian Blood Services, Ottawa, ON, Canada
| | | |
Collapse
|
16
|
Amartely H, David A, Shamir M, Lebendiker M, Izraeli S, Friedler A. Differential effects of zinc binding on structured and disordered regions in the multidomain STIL protein. Chem Sci 2016; 7:4140-4147. [PMID: 30155058 PMCID: PMC6014068 DOI: 10.1039/c6sc00115g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2016] [Accepted: 03/01/2016] [Indexed: 11/24/2022] Open
Abstract
Here we show that simultaneous binding of Zn2+ ions has different effects on structured and disordered domains in the same multidomain protein.
Binding of metal ions is an important regulatory mechanism in proteins. Specifically, Zn2+ binding to disordered regions commonly induces a disorder to order transition and gain of structure or oligomerization. Here we show that simultaneous binding of Zn2+ ions has different effects on structured and disordered domains in the same multidomain protein. The centrosomal STIL protein bound Zn2+ ions via both its structured N-terminal domain (NTD) and disordered central region (IDR). Zn2+ binding induced structural rearrangement of the structured NTD but promoted oligomerization of the IDR. We suggest that by binding Zn2+ STIL acquires a different conformation, which allows its oligomerization and induces its activity. Sequence alignment of the oligomerization region revealed a new suggested motif, SxKxS/SxHxS/SxLxS, which may participate in STIL oligomerization. Binding of the same metal ion through a disordered and a structured domain in the same protein is a property that may have implications in regulating the protein activity. By doing so, the protein achieves two parallel outcomes: structural changes and oligomerization that can take place together. Our results describe a new important role of the delicate interplay between structure and intrinsic disorder in proteins.
Collapse
Affiliation(s)
- Hadar Amartely
- Institute of Chemistry , Hebrew University of Jerusalem , Safra Campus, Givat Ram , Jerusalem 91904 , Israel
| | - Ahuvit David
- Sheba Cancer Research Center and the Edmond and Lily Safra Children Hospital , Sheba Medical Center , Tel-Hashomer 52621 , Israel.,Department of Molecular Genetics and Biochemistry , Faculty of Medicine , Tel Aviv University , Tel Aviv , Israel
| | - Mai Shamir
- Institute of Chemistry , Hebrew University of Jerusalem , Safra Campus, Givat Ram , Jerusalem 91904 , Israel
| | - Mario Lebendiker
- The Wolfson Centre for Applied Structural Biology , Hebrew University of Jerusalem , Safra Campus, Givat Ram , Jerusalem 91904 , Israel
| | - Shai Izraeli
- Sheba Cancer Research Center and the Edmond and Lily Safra Children Hospital , Sheba Medical Center , Tel-Hashomer 52621 , Israel.,Department of Molecular Genetics and Biochemistry , Faculty of Medicine , Tel Aviv University , Tel Aviv , Israel
| | - Assaf Friedler
- Institute of Chemistry , Hebrew University of Jerusalem , Safra Campus, Givat Ram , Jerusalem 91904 , Israel
| |
Collapse
|
17
|
Johnson L, Tan S, Wood B, Davis A, Marks DC. Refrigeration and cryopreservation of platelets differentially affect platelet metabolism and function: a comparison with conventional platelet storage conditions. Transfusion 2016; 56:1807-18. [DOI: 10.1111/trf.13630] [Citation(s) in RCA: 87] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Revised: 03/14/2016] [Accepted: 03/20/2016] [Indexed: 01/02/2023]
Affiliation(s)
- Lacey Johnson
- Research and Development; Australian Red Cross Blood Service; Sydney NSW Australia
| | - Shereen Tan
- Research and Development; Australian Red Cross Blood Service; Sydney NSW Australia
| | - Ben Wood
- Research and Development; Australian Red Cross Blood Service; Sydney NSW Australia
- Proteomics Core Facility; University of Technology Sydney; Sydney NSW Australia
| | - April Davis
- Research and Development; Australian Red Cross Blood Service; Sydney NSW Australia
| | - Denese C. Marks
- Research and Development; Australian Red Cross Blood Service; Sydney NSW Australia
| |
Collapse
|
18
|
Depolarization of Light Scattered in Water Dispersions of Nanoparticles of Different Shapes. BIOMEDICAL ENGINEERING 2016. [DOI: 10.1007/s10527-016-9574-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Platelet microparticles in cryopreserved platelets: Potential mediators of haemostasis. Transfus Apher Sci 2015; 53:146-52. [DOI: 10.1016/j.transci.2015.10.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
20
|
Raynel S, Padula MP, Marks DC, Johnson L. Cryopreservation alters the membrane and cytoskeletal protein profile of platelet microparticles. Transfusion 2015; 55:2422-32. [PMID: 26046916 DOI: 10.1111/trf.13165] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Revised: 04/01/2015] [Accepted: 04/02/2015] [Indexed: 12/11/2022]
Abstract
BACKGROUND Cryopreservation of platelets (PLTs) in dimethyl sulfoxide (DMSO) and storage at -80 °C extends the PLT shelf life to at least 2 years, allowing greater accessibility in military and rural environments. While cryopreserved PLTs have been extensively characterized, the microparticles formed as a result of cryopreservation are yet to be fully described. STUDY DESIGN AND METHODS Apheresis PLTs were cryopreserved at -80 °C with 5% DMSO and sampled before freezing and after thawing. Microparticle number, size, surface receptor phenotype, and function were assessed by microscopy, flow cytometry, dynamic light scattering, and thrombin-generating capacity. Proteomic changes were examined using two-dimensional gel electrophoresis and Western blotting. RESULTS PLT cryopreservation resulted in a 15-fold increase in the number of microparticles compared to fresh PLTs. The surface receptor phenotype of these microparticles differed to microparticles from fresh PLTs, with more microparticles expressing glycoprotein (GP)IV, GPIIb, and the GPIb-V-IX complex. Cryopreservation drastically altered the abundance of many cytoskeletal proteins in the PLT microparticles, including actin, filamin, gelsolin, and tropomyosin. Despite these changes, PLT microparticles were functional and contributed to phosphatidylserine- and tissue factor- induced thrombin generation. CONCLUSION This study demonstrates that PLT microparticles formed by cryopreservation are phenotypically distinct from those present before freezing. These differences may be associated with the procoagulant properties of cryopreserved PLTs.
Collapse
Affiliation(s)
- Sarah Raynel
- Research & Development, Australian Red Cross Blood Service, Alexandria, NSW, Australia.,Proteomics Core Facility, University of Technology Sydney, Sydney, NSW, Australia
| | - Matthew P Padula
- Proteomics Core Facility, University of Technology Sydney, Sydney, NSW, Australia
| | - Denese C Marks
- Research & Development, Australian Red Cross Blood Service, Alexandria, NSW, Australia
| | - Lacey Johnson
- Research & Development, Australian Red Cross Blood Service, Alexandria, NSW, Australia
| |
Collapse
|
21
|
Black A, Pienimaeki-Roemer A, Kenyon O, Orsó E, Schmitz G. Platelet-derived extracellular vesicles in plateletpheresis concentrates as a quality control approach. Transfusion 2015; 55:2184-96. [DOI: 10.1111/trf.13128] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Revised: 02/07/2015] [Accepted: 02/25/2015] [Indexed: 12/18/2022]
Affiliation(s)
- Anne Black
- Institute for Laboratory Medicine and Transfusion Medicine; University of Regensburg; Regensburg Germany
| | - Annika Pienimaeki-Roemer
- Institute for Laboratory Medicine and Transfusion Medicine; University of Regensburg; Regensburg Germany
| | | | - Evelyn Orsó
- Institute for Laboratory Medicine and Transfusion Medicine; University of Regensburg; Regensburg Germany
| | - Gerd Schmitz
- Institute for Laboratory Medicine and Transfusion Medicine; University of Regensburg; Regensburg Germany
| |
Collapse
|
22
|
Kraemer L, Raczat T, Weiss DR, Strobel J, Eckstein R, Ringwald J. Correlation of the hypotonic shock response and extent of shape change with the new ThromboLUX ™. Vox Sang 2015; 109:194-6. [PMID: 25899969 DOI: 10.1111/vox.12268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 02/02/2015] [Accepted: 02/09/2015] [Indexed: 11/30/2022]
Abstract
ThromboLUX (TLX)-Score was compared with hypotonic shock response (HSR) and extent of shape change (ESC) in 99 samples from 42 platelet concentrates. Tests were performed in parallel and duplicate. Mean values for TLX Score, HSR and ESC were 30.3 ± 3.8%, 69.0 ± 12.2% and 23.2 ± 4.9%, respectively. We found no significant correlation between TLX Score and HSR or ESC (r = -0.158, P = 0.118 and r = -115, P = 0.255, respectively), whereas HSR and ESC correlated significantly (r = 0.351, P < 0.001). As TLX Score did not show significant correlation with HSR and ESC, the value of TLX for platelet quality testing remains unclear. Studies comparing these parameters with transfusion outcome are needed.
Collapse
Affiliation(s)
- L Kraemer
- Department of Transfusion Medicine and Haemostaseology, University Hospital of Erlangen, Erlangen, Germany
| | - T Raczat
- Department of Transfusion Medicine and Haemostaseology, University Hospital of Erlangen, Erlangen, Germany
| | - D R Weiss
- Department of Transfusion Medicine and Haemostaseology, University Hospital of Erlangen, Erlangen, Germany
| | - J Strobel
- Department of Transfusion Medicine and Haemostaseology, University Hospital of Erlangen, Erlangen, Germany
| | - R Eckstein
- Department of Transfusion Medicine and Haemostaseology, University Hospital of Erlangen, Erlangen, Germany
| | - J Ringwald
- Department of Transfusion Medicine and Haemostaseology, University Hospital of Erlangen, Erlangen, Germany
| |
Collapse
|
23
|
Raczat T, Kraemer L, Gall C, Weiss DR, Eckstein R, Ringwald J. The influence of four different anticoagulants on dynamic light scattering of platelets. Vox Sang 2014; 107:196-9. [PMID: 24712311 DOI: 10.1111/vox.12150] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Revised: 03/13/2014] [Accepted: 03/13/2014] [Indexed: 11/25/2022]
Abstract
For testing of dynamic light scattering of platelets with ThromboLUX (TLX) in platelet-rich plasma (PRP) derived from venous whole blood (vWB), anticoagulation is needed. We compared TLX score in PRPs containing citrate, ethylene-diamine-tetraacetic-acid (EDTA), citrate-phosphate-dextrose-adenine (CPDA) or citrate-theophylline-adenosine-dipyridamole. Initial and late TLX scores were measured after 30-120 min or four to six hours, respectively. Compared with citrate, mean differences in initial TLX score were only significant for CPDA. Also, mean differences between initial and late TLX scores were only significant for CPDA. TLX failed to detect EDTA-induced platelet alterations. The clinical relevance of TLX needs further studies.
Collapse
Affiliation(s)
- T Raczat
- Department of transfusion medicine and hemostaseology, University Hospital of Erlangen, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
| | | | | | | | | | | |
Collapse
|
24
|
Bugert P. The gears keep turning: current progress in platelet function testing. Transfus Med Hemother 2013; 40:71. [PMID: 23653568 PMCID: PMC3638922 DOI: 10.1159/000350692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2024] Open
Affiliation(s)
- Peter Bugert
- Institute of Transfusion Medicine and Immunology, Medical Faculty Mannheim, Heidelberg University; German Red Cross Blood Service Baden-Württemberg – Hessen; Mannheim, Germany
| |
Collapse
|