Feng Y, Nitter T, Bertelsen G, Stojanovic A. Repeatability and agreement of total corneal astigmatism measured in keratoconic eyes using four current devices. Clin Exp Ophthalmol 2024. [PMID: 39034272 DOI: 10.1111/ceo.14423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 07/08/2024] [Accepted: 07/09/2024] [Indexed: 07/23/2024]
Abstract
BACKGROUND To evaluate repeatability and agreement in measurements of total corneal astigmatism (TCA) in keratoconic eyes, using four optical coherence tomography (OCT)-based devices: Anterion, Casia SS-1000, IOLMaster 700, and MS-39. METHODS Three consecutive measurements were taken with each device in 136 eyes. TCA values were converted into components J0 and J45. The Anterion and the IOLMaster 700 also provided axial length (AL) measurements. The repeatability was calculated using pooled within-subject standard deviation (Sw). The agreement among the four devices was assessed by pairwise comparisons and Bland-Altman plots. RESULTS For all devices, the repeatability of TCA measurements showed Sw ≤0.23 D for TCA magnitude, ≤0.14 D for J0, and ≤0.12 D for J45. There were statistically significant differences in TCA magnitude for each pair, except for IOLMaster 700 with MS-39, and Anterion with MS-39. The repeatability (Sw) of axis measurements had a statistically significant negative correlation with the TCA magnitude (p < 0.001 for all devices). Both Anterion and IOLMaster 700 had high repeatability in AL measurements (Sw: 0.007 mm for Anterion and 0.009 mm for IOLMaster 700). The difference in AL between the two was 0.015 ± 0.033 mm (p < 0.001). CONCLUSIONS All four devices showed good repeatability in TCA measurements in keratoconic eyes, the agreement for TCA measurements between the tested devices was generally low. Anterion and IOLMaster 700 showed good repeatability and agreement in AL measurements.
Collapse
Affiliation(s)
- Yue Feng
- Institute of Community Medicine, Faculty of Health Sciences, University in Tromsø, Tromsø, Norway
| | | | - Geir Bertelsen
- Institute of Community Medicine, Faculty of Health Sciences, University in Tromsø, Tromsø, Norway
- Department of Ophthalmology, University Hospital North Norway, Tromsø, Norway
| | - Aleksandar Stojanovic
- Department of Ophthalmology, University Hospital North Norway, Tromsø, Norway
- Institute of Clinical Medicine, Faculty of Health Sciences, University in Tromsø, Tromsø, Norway
| |
Collapse
|
2
|
Almusawi LA, Hamied FM. Risk Factors for Development of Keratoconus: A Matched Pair Case-Control Study. Clin Ophthalmol 2021; 15:3473-3479. [PMID: 34429579 PMCID: PMC8378899 DOI: 10.2147/opth.s248724] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 08/04/2021] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Keratoconus, a progressive ectatic corneal disorder, is believed to be multifactorial in etiology with interaction between genetic and environmental factors. To date, risk factors for the development of the disease are extensively debated and need to be identified since they play a critical role in disease prevention and management. This study aimed to analyze associations between several hereditary and environmental predictors and the development of keratoconus. PATIENTS AND METHODS This was a retrospective matched pair case-control study. The study was conducted in Ibn-Alhaitham eye teaching hospital between March 2016 and April 2017. Patients with keratoconus (cases) and their age- and gender-matched controls were asked about childhood and early teenage eye rubbing, ocular trauma, obesity, contact lens wear, smoking and sunlight exposure, family history of keratoconus, parental consanguinity and information related to socio-economic status. Univariable and multivariable conditional logistic regression analyses were used to test the significance of associations. RESULTS A total of 166 individuals (83 cases and 83 controls; 60.2% female) were included. On univariable analysis, eye rubbing, family history of keratoconus and parental consanguinity were significant risk factors for keratoconus, whereas all other factors were non-significant. On multivariable analysis, eye rubbing (odds ratio: 4.93; P < 0.01), family history of keratoconus (odds ratio: 25.52; P < 0.01) and parental consanguinity (odds ratio: 2.89; P = 0.02), again, emerged as significant risk factors for disease development. CONCLUSION Family history of keratoconus, eye rubbing, and parental consanguinity were significant risk factors for keratoconus development. These results support the evidence for multifactorial etiology, the most important factor being hereditary predisposition.
Collapse
Affiliation(s)
| | - Furkaan Majied Hamied
- Department of Surgery, College of Medicine, University of Al-Qadisiyah, Al Diwaniyah, Iraq
| |
Collapse
|
3
|
Kanclerz P, Khoramnia R, Wang X. Current Developments in Corneal Topography and Tomography. Diagnostics (Basel) 2021; 11:diagnostics11081466. [PMID: 34441401 PMCID: PMC8392046 DOI: 10.3390/diagnostics11081466] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/07/2021] [Accepted: 08/11/2021] [Indexed: 02/07/2023] Open
Abstract
Introduction: Accurate assessment of the corneal shape is important in cataract and refractive surgery, both in screening of candidates as well as for analyzing postoperative outcomes. Although corneal topography and tomography are widely used, it is common that these technologies are confused. The aim of this study was to present the current developments of these technologies and particularly distinguish between corneal topography and tomography. Methods: The PubMed, Web of Science and Embase databases were the main resources used to investigate the medical literature. The following keywords were used in various combinations: cornea, corneal, topography, tomography, Scheimpflug, Pentacam, optical coherence tomography. Results: Topography is the study of the shape of the corneal surface, while tomography allows a three-dimensional section of the cornea to be presented. Corneal topographers can be divided into large- and small-cone Placido-based devices, as well as devices with color-LEDs. For corneal tomography, scanning slit or Scheimpflug imaging and optical coherence tomography may be employed. In several devices, corneal topography and tomography have been successfully combined with tear-film analysis, aberrometry, optical biometry and anterior/posterior segment optical coherence tomography. Conclusion: There is a wide variety of imaging techniques to obtain corneal power maps. As different technologies are used, it is imperative that doctors involved in corneal surgery understand the science and clinical application of devices for corneal evaluation in depth.
Collapse
Affiliation(s)
- Piotr Kanclerz
- Hygeia Clinic, Department of Ophthalmologyul, Jaśkowa Dolina 57, 80-286 Gdańsk, Poland
- Helsinki Retina Research Group, University of Helsinki, 00100 Helsinki, Finland
- Correspondence:
| | - Ramin Khoramnia
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany;
| | - Xiaogang Wang
- Department of Cataract, Shanxi Eye Hospital, Taiyuan 030002, China;
| |
Collapse
|
4
|
Masiwa LE, Moodley V. A review of corneal imaging methods for the early diagnosis of pre-clinical Keratoconus. JOURNAL OF OPTOMETRY 2020; 13:269-275. [PMID: 31917136 PMCID: PMC7520528 DOI: 10.1016/j.optom.2019.11.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 10/22/2019] [Accepted: 11/09/2019] [Indexed: 05/15/2023]
Abstract
BACKGROUND Keratoconus (KC) is a corneal ectasia characterised by steepening corneal curvature, changes in refractive error and corneal thickness that result in visual impairment. Early signs of KC include displacement of the thinnest part of the cornea from the central position, changes in the corneal epithelial layer cell distribution, variations in the anterior corneal astigmatism/posterior corneal astigmatism relationship and a variation in corneal thickness. It is important that we review the corneal imaging methods for the diagnosis of preclinical KC. METHOD An online literature search was carried out on PubMed. Only publications detailing corneal assessment procedures were considered for this review and any publication on instruments that did not generate KC predictability indices were also excluded from the review. The 308 publications were reviewed. DISCUSSION Corneal assessment techniques, with the ability to characterise both the anterior and posterior corneal surfaces, are invaluable in the diagnosis of pre-clinical KC. Reflection based and elevation based corneal imaging systems should be used in conjunction with other assessments such as higher order aberration measuring systems to improve sensitivity and reliability in the diagnosis of pre-clinical KC. Ultra high resolution ultrasound can detect pre-clinical KC. The ability to asses both the epithelium and endothelium makes anterior surface optical coherence tomography a superior technique for pre-clinical KC diagnosis. There is a positive correlation between central corneal thickness and corneal hysteresis. Corneal biomechanics should be considered in conjunction with other corneal assessments in the diagnosis of pre-clinical KC.
Collapse
Affiliation(s)
- Lynett Erita Masiwa
- Department of Ophthalmology, University of Zimbabwe, College of Health Sciences, P. O. Box A178, Avondale, Harare, Zimbabwe.
| | - Vanessa Moodley
- School of Health Sciences, Department of Optometry, University of Kwazulu Natal, Durban, South Africa
| |
Collapse
|
5
|
Kanellopoulos AJ. Scheimpflug vs Scanning-Slit Corneal Tomography: Comparison of Corneal and Anterior Chamber Tomography Indices for Repeatability and Agreement in Healthy Eyes. Clin Ophthalmol 2020; 14:2583-2592. [PMID: 32943840 PMCID: PMC7481306 DOI: 10.2147/opth.s251998] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 08/14/2020] [Indexed: 12/11/2022] Open
Abstract
Purpose To evaluate and compare the repeatability and agreement of Scheimpflug vs scanning-slit tomography of the cornea and the anterior chamber in terms of keratometric and tomographic indices in healthy eyes. Methods The 20 eyes of 10 healthy participants underwent 3 consecutive measurements using both Scheimpflug-tomography and scanning-slit tomography, diagnostic devices. Multiple corneal and anterior chamber tomographic parameters were recorded and evaluated to include corneal keratometry and its axis; corneal best-fit sphere (BFS), pachymetry mapping, angle kappa, anterior chamber depth (ACD), pupil diameter, and location. Repeatability for each device was assessed using the within each subject standard deviation of sequential exams, the coefficient variation (CV) and the intraclass correlation coefficient (ICC). Agreement between the two devices was assessed using Bland-Altman plots with 95% limits of agreement (LoA) and correlation coefficient (r). Results Both devices were found to have high repeatability (ICC>0.9) both in keratometric and other tomographic measurements. Scheimpflug tomography's repeatability though appeared superior in the average keratometry values, anterior and posterior BFS, thinnest corneal pachymetry value and location (p<0.05). Agreement: Statistically significant inter-device differences were noted in the mean values of K1, K2, BFS, ACD and thinnest corneal pachymetry (p<0.05). Despite the agreement differences noted, the two devices were well correlated (r>0.8) in respective measurements with Scheimpflug delivering consistently lower values than the scanning-slit tomography device. Conclusion Scheimpflug-tomography repeatability was found to be superior to that of scanning-slit tomography in this specific study, in most parameters evaluated. Inter-device agreement evaluation suggests that reading from the two devices may not be used interchangeably in absolute values, yet they are well correlated with Scheimpflug delivering consistently lower values in most.
Collapse
Affiliation(s)
- Anastasios John Kanellopoulos
- Department of Ophthalmology, The LaserVision Clinical and Research Eye Institute, Athens, Attiki, Greece.,Department of Ophthalmology, New York University Medical School, New York City, NY, USA
| |
Collapse
|
6
|
Lu W, Miao Y, Li Y, Hu X, Hu Q, Huang J. Comparison of Multicolored Spot Reflection Topographer and Scheimpflug-Placido System in Corneal Power and Astigmatism Measurements With Normal and Post-refractive Patients. J Refract Surg 2019; 35:370-376. [PMID: 31185102 DOI: 10.3928/1081597x-20190510-01] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 05/09/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the repeatability of corneal power and astigmatism derived by a novel multicolored spot reflection topographer system (Cassini; i-Optics, Hague, Netherlands) and compare its agreement with a Placido-Scheimpflug system (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy) in normal and post-refractive patients. METHODS This prospective study comprised patients who underwent myopic excimer laser refractive surgery (96 eyes) and normal patients (102 eyes). Each patient was measured three times with the Cassini and Sirius. The simulated keratometry (SimK), total corneal power (TCP), and astigmatism were recorded. The repeatability was assessed by one-way analysis of variance. The paired t test was used to compare the differences, whereas the agreement was evaluated by Bland-Altman analysis. RESULTS All parameters obtained by the Cassini demonstrated high repeatability, except for total corneal astigmatism (TCA) in the post-refractive group. The intraclass correlation coefficients of all parameters were greater than 0.85, the correlation of variation values was less than 0.55%, and the test-retest repeatability was less than 0.85 diopters (D). The paired t test showed significant differences in steep keratometry, astigmatism, TCP, and TCA in the normal group and in J0, TCP, and TCA in the post-refractive group. The 95% limits of agreement (LoA) in the normal group demonstrated good agreement, except for TCP. Only J0 and J45 of astigmatism and TCA remained narrow for 95% LoA in the post-refractive group. CONCLUSIONS These results suggested that the Cassini provided high repeatable measurements in corneal power and astigmatism, except the TCA of post-refractive patients. The parameters could be used interchangeably in normal patients, except for TCP, whereas only J0 of astigmatism and J0, J45 of TCA showed good agreement in post-refractive patients. [J Refract Surg. 2019;35(6):370-376.].
Collapse
|
7
|
Piñero DP, Molina-Martín A, Camps VJ, de Fez D, Caballero MT. Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes. Graefes Arch Clin Exp Ophthalmol 2019; 257:2437-2447. [PMID: 31482276 DOI: 10.1007/s00417-019-04453-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 07/12/2019] [Accepted: 08/27/2019] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To evaluate the intrasession repeatability of anterior corneal topographic and aberrometric measurements provided by a color-LED topographer as well as their interchangeability with those provided by a Scheimpflug-based system in healthy eyes. METHODS Thirty-five healthy eyes of 35 patients (age, 16-66 years) were enrolled. A complete eye examination was performed in all cases including a complete corneal analysis with the Scheimpflug-based system Pentacam (Oculus Optikgeräte) (one measurement) and the Cassini system (i-Optics) (three consecutive measurements). Intrasession repeatability of the Cassini measurements was assessed with the within-subject standard deviation (Sw) and the intraclass correlation coefficient (ICC). The Bland-Altman analysis was used to evaluate the agreement between both devices. RESULTS Mean Sw for keratometric readings was 0.02 mm (ICC ≥ 0.992), ranging between 0.16 and 0.05 D (ICC 0.930-0.978) for anterior and total astigmatic measurements. Mean Sw for asphericity and corneal diameter were 0.06 (ICC 0.926) and 0.03 mm (IC 0.997), respectively. Aberrometric parameters showed ICCs ≥ 0.816, except for Z42 (ICC 0.741) and Z44 (ICC 0.544). When comparing devices, statistically significant differences were found for most of topographic and aberrometric data (p ≤ 0.044). Likewise, ranges of agreement between devices were clinically relevant (keratometry > 0.06 mm; total astigmatic components > 0.69 D; asphericity 0.35; second-, third-, and fourth-order Zernike terms, more than 0.20, 0.13, and 0.01 μm, respectively). CONCLUSIONS Consistent anterior corneal topographic, total corneal astigmatic, and aberrometric measurements are obtained with color-LED topography in healthy eyes, which are not interchangeable with those provided by the Scheimpflug-based topography.
Collapse
Affiliation(s)
- David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig s/n, 03690, San Vicente del Raspeig, Alicante, Spain.
- Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain.
| | - Ainhoa Molina-Martín
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig s/n, 03690, San Vicente del Raspeig, Alicante, Spain
| | - Vicent J Camps
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig s/n, 03690, San Vicente del Raspeig, Alicante, Spain
| | - Dolores de Fez
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig s/n, 03690, San Vicente del Raspeig, Alicante, Spain
| | - María Teresa Caballero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig s/n, 03690, San Vicente del Raspeig, Alicante, Spain
| |
Collapse
|
8
|
Piñero DP, Camps VJ, de Fez D, García C, Caballero MT. Validation of posterior corneal curvature measurements with color light-emitting diode topography. Eur J Ophthalmol 2019; 30:1261-1267. [PMID: 31432704 DOI: 10.1177/1120672119870738] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the intrasession repeatability and validity of posterior corneal curvature and astigmatism measurements provided by a color light-emitting diode reflection topography system in healthy eyes. METHODS A total of 40 healthy eyes of 40 patients (age, 16-66 years) were enrolled. A complete eye examination was performed in all cases including posterior topographic analysis with two systems: the Scheimpflug-based system (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) and the Cassini system (i-Optics; Ophthec, The Hague, The Netherlands). With this last system, three consecutive measurements were taken to assess the level of intrasession repeatability (within-subject standard deviation, Sw; intraclass correlation coefficient). The Bland & Altman analysis was used to evaluate the interchangeability of both devices. RESULTS The Sw was ⩽0.06 mm for all posterior corneal radius measurements, with intraclass correlation coefficient of ⩾0.960. The Sw for the magnitude of astigmatism, J0, and J45 were 0.15, 0.04, and 0.04 D, respectively, with intraclass correlation coefficient values of 0.876, 0.897, and 0.840, respectively. Statistically significant differences between devices were found in all parameters evaluated (p ⩽ 0.025). The interchangeability analysis revealed the presence of clinically relevant limits of agreement for the flattest (0.03 to 0.50 mm) and steepest posterior corneal radii (-0.01 to 0.39 mm). In contrast, limits of agreements were not clinically relevant for the magnitude of posterior astigmatism (-0.17 to 0.27 D) and their power vector components (-0.11 to 0.15 D). CONCLUSION The Cassini system provides consistent measures of posterior corneal curvature and astigmatism in healthy eyes, but only measures of posterior astigmatism can be considered as interchangeable with those provided by the Pentacam.
Collapse
Affiliation(s)
- David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.,Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain
| | - Vicent J Camps
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - Dolores de Fez
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - Celia García
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | | |
Collapse
|
9
|
Distinguishing between contact lens warpage and ectasia: Usefulness of optical coherence tomography epithelial thickness mapping. J Cataract Refract Surg 2019; 43:60-66. [PMID: 28317679 DOI: 10.1016/j.jcrs.2016.10.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 09/22/2016] [Accepted: 10/16/2016] [Indexed: 11/22/2022]
Abstract
PURPOSE To distinguish between corneal ectasia and contact lens-related warpage by characteristic patterns on corneal topography and optical coherence tomography (OCT) epithelial thickness maps. SETTING Casey Eye Institute, Portland, Oregon, USA. DESIGN Prospective and retrospective case series. METHODS Axial and mean power maps were obtained on corneal topography systems. Epithelial thickness maps were generated using RTVue OCT. A sector divider was applied to all maps. The locations of the minimum epithelial thickness, maximum epithelial thickness, maximum axial power, and maximum mean power were determined based on sector averages. Agreement was defined as the extremums occurring in the same or adjacent sectors. RESULTS Twenty-one eyes with keratoconus, 6 eyes with forme fruste keratoconus (better eye of asymmetric keratoconus), and 15 eyes with contact lens-related warpage were identified. The keratoconus and forme fruste keratoconus eyes had coincident topographic steepening with epithelial thinning. The locations of minimum epithelial thickness and maximum axial power agreed in 90% of the keratoconic eyes, while the minimum epithelial thickness and maximum mean power agreed in 95% of them. Conversely, the warpage eyes had coincident topographic steepening with epithelial thickening and normal pachymetry maps. The locations of maximum epithelial thickness and maximum axial power agreed in 93% of the warpage eyes, while the maximum epithelial thickness and maximum mean power agreed in all warpage eyes. CONCLUSION Results show that epithelial thickness maps and corneal topographic maps are powerful synergistic tools in evaluating eyes with abnormal topography and can help differentiate between keratoconus and nonectatic conditions.
Collapse
|
10
|
Cui XH, Yoo YS, An Y, Joo CK. Comparison of keratometric measurements between color light-emitting diode topography and Scheimpflug camera. BMC Ophthalmol 2019; 19:98. [PMID: 31027491 PMCID: PMC6486681 DOI: 10.1186/s12886-019-1106-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Accepted: 04/12/2019] [Indexed: 11/21/2022] Open
Abstract
Background To determine the agreement of measurements between color light-emitting diode corneal topography (Cassini) and Scheimpflug camera keratometry (Pentacam HR). Methods The current retrospective study investigated 117 right eyes of 117 healthy patients before cataract surgery from June 2017 to July 2017. Steep K, flat K, mean K, astigmatism, and axis for both anterior and posterior corneal surface were measured using the two devices. The measured values were converted into J vectors such as J0 and J45. The mean difference for those measurement values were compared between the two instruments, and the agreement was evaluated using the Bland-Altman plot I. Results There were statistically significant differences in mean K (44.21D [43.34 to 45.34] and 44.30D [43.30 to 45.10] by Cassini and Pentacam [P = 0.004]) and astigmatism (0.90D [0.58 to 1.30] and 0.70D [0.40 to 1.30] by Cassini and Pentacam [P = 0.002]) on the anterior corneal surface and flat K (− 6.21D [− 6.39 to − 6.07] and − 6.30D [− 6.5 to − 6.10] by Cassini and Pentacam [P < 0.001]), mean K (− 6.39D [− 6.54 to − 6.25] and − 6.40D [− 6.60 to − 6.30] by Cassini and Pentacam [P = 0.019]), and astigmatism (0.33D [0.22 to 0.47] and 0.30D [0.15 to 0.40] by Cassini and Pentacam [P = 0.002]) on the posterior corneal surface. The mean difference (= Cassini – Pentacam) with 95% limit of agreement for mean K and astigmatism of the anterior corneal surface were 0.082D (− 0.60 to 0.76) and 0.11D (− 0.73 to 0.95) for measurements obtained by the two instruments, respectively. Regarding keratometric values from the posterior corneal surface, the mean differences for flat K, mean K, and astigmatism were − 0.081D (− 0.42 to 0.26), − 0.030D (− 0.32 to 0.26), and 0.067D (− 0.33 to 0.46), respectively. Intraclass correlation coefficients for steep K, flat K, mean K, and vector J0 were higher than 0.9 in the anterior cornea. Positive correlation in steep K, flat K, mean K, astigmatism, and J0 was found between two devices in both anterior and posterior cornea (P < 0.001). Conclusions Corneal refractive power and astigmatism tend to be higher when measured using Cassini than Pentacam HR in both anterior and posterior cornea. The two different devices might not be used interchangeably. Trial registration Retrospectively registered. Registration number: KC17RESI0439.
Collapse
Affiliation(s)
- Xian-Hua Cui
- Department of Ophthalmology and Visual Science, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, South Korea.,Department of Ophthalmology, Yanbian University Hospital, #1327 Juzi St, Yanji, 133000, Jilin Province, People's Republic of China
| | - Young-Sik Yoo
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, South Korea
| | - Youngju An
- Department of Optometry, Baekseok Culture University, 58, Munam-ro, Dongnam-gu, Cheonan-si, Chungcheongnam-do, South Korea
| | - Choun-Ki Joo
- Department of Ophthalmology and Visual Science, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, South Korea.
| |
Collapse
|
11
|
Ferreira TB, Ribeiro FJ. Comparability and repeatability of different methods of corneal astigmatism assessment. Clin Ophthalmol 2017; 12:29-34. [PMID: 29339918 PMCID: PMC5745151 DOI: 10.2147/opth.s146730] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To assess the comparability and repeatability of keratometric and astigmatism values measured by four techniques: Orbscan IIz® (Bausch and Lomb), Lenstar LS 900® (Haag-Streit), Cassini® (i-Optics), and Total Cassini (anterior + posterior surface), in healthy volunteers. Patients and methods Fifteen healthy volunteers (30 eyes) were assessed by the four techniques. In each eye, three consecutive measures were performed by the same operator. Keratometric and astigmatism values were recorded. The intraclass correlation coefficient (ICC) was used to assess comparability and repeatability. Agreement between measurement techniques was evaluated with Bland-Altman plots. Results Comparability was high between all measurement techniques for minimum keratometry (K1), maximum keratometry (K2), astigmatism magnitude, and astigmatism axis, with ICC >0.900, except for astigmatism magnitude measured by Cassini compared to Lenstar (ICC =0.798) and Orbscan compared to Lenstar (ICC =0.810). However, there were some differences in the median values of K1 and K2 between measurement techniques, and the Bland-Altman plots showed a wide data spread for all variables, except for astigmatism magnitude measured by Cassini and Total Cassini. For J0 and J45, comparability was only high for J0 between Cassini and Orbscan. Repeatability was also high for all measurement techniques except for K2 (ICC =0.814) and J45 (ICC =0.621) measured by Cassini. Conclusion All measurement techniques showed high comparability regarding K1, K2, and astigmatism axis. Although posterior corneal surface is known to influence these measurements, comparability was high between Cassini and Total Cassini regarding astigmatism magnitude and axis. However, the wide data spread suggests that none of these devices should be used interchangeably.
Collapse
|
12
|
Ferreira TB, Ribeiro FJ. A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes. Clin Ophthalmol 2016; 10:1521-9. [PMID: 27574391 PMCID: PMC4990375 DOI: 10.2147/opth.s113027] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To assess the accuracy of corneal astigmatism evaluation measured by four techniques, Orbscan IIz(®), Lenstar LS900(®), Cassini(®), and Total Cassini (anterior + posterior surface), in pseudophakic eyes. PATIENTS AND METHODS A total of 30 patients (46 eyes) who had undergone cataract surgery with the implantation of a monofocal intraocular lens (AcrySof IQ) were assessed after surgery. For each eye, subjective assessment of astigmatism and its axis was performed. Minimum, maximum, and mean keratometry and astigmatism and its axis were evaluated using the four measurement techniques. All measurements were compared with the subjective measurements. Agreement between each measurement technique and subjective assessment was evaluated using Bland-Altman plots. Linear regressions were performed and compared. RESULTS Linear regression analysis of astigmatism axis showed very high R (2) for all models, with Total Cassini showing the least difference to the unit slope (0.052) and the least difference to a null constant (3.790), although not statistically different from the other models. Regarding astigmatism value, the Cassini and Total Cassini models were similar and statistically better than the Lenstar model. Cassini and Total Cassini showed better J0 compared with Orbscan. CONCLUSION On linear regression models, Cassini and Total Cassini showed the best performance regarding astigmatism value. Cassini and Total Cassini also showed the least J0 deviation from the Cartesian origin compared with Orbscan, which had the lowest performance. Total corneal measurement with the color LED topographer seems to be a better technique for astigmatism assessment.
Collapse
|
13
|
Cavas-Martínez F, De la Cruz Sánchez E, Nieto Martínez J, Fernández Cañavate FJ, Fernández-Pacheco DG. Corneal topography in keratoconus: state of the art. EYE AND VISION 2016; 3:5. [PMID: 26904709 PMCID: PMC4762162 DOI: 10.1186/s40662-016-0036-8] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Accepted: 02/14/2016] [Indexed: 11/12/2022]
Abstract
The morphological characterization of the cornea using corneal topographers is a widespread clinical practice that is essential for the diagnosis of keratoconus. The current state of this non-invasive exploratory technique has evolved with the possibility of achieving a great number of measuring points of both anterior and posterior corneal surfaces, which is possible due to the development of new and advanced measurement devices. All these data are later used to extract a series of topographic valuation indices that permit to offer the most exact and reliable clinical diagnosis. This paper describes the technologies in which current corneal topographers are based on, being possible to define the main morphological characteristics that the keratoconus pathology produces on corneal surface. Finally, the main valuation indices, which are provided by the corneal topographers and used for the diagnosis of keratoconus, are also defined.
Collapse
Affiliation(s)
- F Cavas-Martínez
- Department of Graphical Expression, Technical University of Cartagena, C/Doctor Fleming s/n, Cartagena, 30202, Murcia Spain
| | - E De la Cruz Sánchez
- Faculty of Sports Science, C/ Santa Alicia s/n, Santiago de la Ribera, 30720 Murcia, Spain
| | - J Nieto Martínez
- Department of Graphical Expression, Technical University of Cartagena, C/Doctor Fleming s/n, Cartagena, 30202, Murcia Spain
| | - F J Fernández Cañavate
- Department of Graphical Expression, Technical University of Cartagena, C/Doctor Fleming s/n, Cartagena, 30202, Murcia Spain
| | - D G Fernández-Pacheco
- Department of Graphical Expression, Technical University of Cartagena, C/Doctor Fleming s/n, Cartagena, 30202, Murcia Spain
| |
Collapse
|
14
|
Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography. Cornea 2016; 34:937-44. [PMID: 26057324 PMCID: PMC4500657 DOI: 10.1097/ico.0000000000000476] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Purpose: To evaluate and investigate the distribution and repeatability of anterior corneal surface astigmatism measurements (axis and magnitude) using a novel corneal topographer. Methods: Anterior corneal surface astigmatism was investigated in a total of 195 eyes using a novel multicolored spot reflection topographer (Cassini; i-Optics). Two patient groups were studied, a younger-age group A and an older-age group B. Three consecutive acquisitions were obtained from each eye. The repeatability of measurement was assessed using Bland–Altman plot analysis and is reported as the coefficient of repeatability. Results: Group A (average age 34.3 years) had on average with-the-rule astigmatism, whereas the older-age group B (average age 72.3 years) had on average against-the-rule astigmatism. Average astigmatism magnitude measurement repeatability in group A was 0.4 diopters (D) and in group B 0.4 D. Average astigmatism axis measurement repeatability in group A was 5.4 degrees and in group B 5.5 degrees. The axis measurement repeatability improved with increasing magnitude of astigmatism: in the subgroups with astigmatism between 3.0 and 6.0 D, the axis repeatability was 1.4 degrees (group A) and 1.2 degrees (group B), whereas in the subgroups with astigmatism larger than 6.0 D, the repeatability was 1.1 and 0.6 degrees, respectively. Conclusions: This novel corneal topography device seems to offer high precision in reporting corneal astigmatism. This study reaffirms the established trend of a corneal astigmatism shift from an average “with-the-rule” to “against-the-rule” with aging.
Collapse
|
15
|
Klijn S, Reus NJ, Sicam VADP. Evaluation of keratometry with a novel Color-LED corneal topographer. J Refract Surg 2015; 31:249-56. [PMID: 25884580 DOI: 10.3928/1081597x-20150212-01] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Accepted: 02/05/2015] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess the performance of a novel keratometer based on reflections of colored light-emitting diodes (LEDs) and compare it with devices based on Placido rings, monochromatic LEDs, and Scheimpflug images. METHODS Sixty-three eyes of 63 patients with virgin corneas underwent keratometry with color-LED corneal topography (Cassini; i-Optics, The Hague, The Netherlands) and with devices based on Placido ring reflections (Keratron; Optikon, Rome, Italy), monochromatic LED reflections (Lenstar; Haag-Streit, Koeniz, Switzerland), and Scheimpflug imaging (Pentacam; Oculus Optikgeräte, Wetzlar, Germany). Three repeated measurements were performed with each device. Comparability and repeatability of corneal power and cylinder measurements were assessed. The Bonferroni-corrected α-threshold for statistical significance was 0.016. RESULTS Corneal power measurements with the Cassini topographer were not statistically significantly different from those with the Pentacam (P = .64). They were statistically significantly lower than those with the Keratron and Lenstar (P < .01), but the differences were of negligible clinical relevance. Cylinder measurements with the Cassini topographer were not statistically significantly different from those with any other device (P = .46). Repeatability of Cassini corneal power measurements was not statistically significantly different from that of the Keratron (P = .02), but was statistically significantly lower than that of the Lenstar and Pentacam (P < .001). Repeatability of Cassini cylinder measurements was statistically significantly higher than that of the Pentacam and Keratron (P < .001), but was not statistically significantly different from that of the Lenstar (P > .05). CONCLUSIONS Corneal power and cylinder measurements with color-LED corneal topography yielded values that were comparable to those of other commonly used devices. Repeatability of corneal power measurements was lower compared to some devices, but repeatability of cylinder measurements was relatively high. This may be of particular interest when using toric intraocular lenses.
Collapse
|
16
|
Hidalgo IR, Rozema JJ, Dhubhghaill SN, Zakaria N, Koppen C, Tassignon MJ. Repeatability and inter-device agreement for three different methods of keratometry: Placido, Scheimpflug, and color LED corneal topography. J Refract Surg 2015; 31:176-81. [PMID: 25751834 DOI: 10.3928/1081597x-20150224-01] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2014] [Accepted: 01/12/2015] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the repeatability of a color LED corneal topographer (Cassini; iOptics, The Hague, The Netherlands) and compare it with Placido and Scheimpflug based devices (EyeSys 2000; EyeSys Laboratories, Houston, TX, and Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany). METHODS This prospective study involved 20 healthy volunteers (20 eyes) recruited from the staff of the Antwerp University Hospital. For each eye, three measurements were taken using each device, from which eight parameters describing keratometry and astigmatism were derived. Repeatability was assessed using intrasession, within-subject analysis of variance. Agreement was evaluated between pairs of devices with Bland- Altman plots and 95% confidence intervals. RESULTS The repeatability values were good for all three devices, although slightly worse for the Cassini than for the other two devices for steep, flat, and mean keratometry. The EyeSys showed worse repeatability for the astigmatism axis. EyeSys and Pentacam agreed well with each other in terms of mean keratometry, whereas the Cassini gave consistently higher values by 0.52 diopters (D) when compared with the EyeSys (P < .05, paired t test) and by 0.38 D when compared with the Pentacam (P < .05, paired t test). The Cassini provided similar repeatability values (2.31°) for the astigmatism axis to the Pentacam (2.22°), in contrast to the EyeSys, which produced much more variable axes (9.0°) (P < .05, paired t test). CONCLUSIONS Overall, the three devices display comparable repeatability. The one exception is the astigmatism axis measurement of the EyeSys. The Cassini provides higher keratometry values than the other two devices, but the astigmatism axis agrees well with that provided by the Pentacam.
Collapse
|
17
|
Kanellopoulos AJ, Asimellis G. Color light-emitting diode reflection topography: validation of keratometric repeatability in a large sample of wide cylindrical-range corneas. Clin Ophthalmol 2015; 9:245-52. [PMID: 25709385 PMCID: PMC4332260 DOI: 10.2147/opth.s68371] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To investigate repeatability of steep and flat keratometry measurements, as well as astigmatism axis in cohorts with normal range and regular astigmatic such as: eyes following laser-assisted in situ keratomileusis (LASIK) and normal population, as well as cohorts of high and irregular astigmatism such as keratoconic eyes, and keratoconic eyes following corneal collagen cross-linking, employing a novel corneal reflection topography device. Methods Steep and flat keratometry and astigmatism axis measurement repeatability was investigated employing a novel multicolored-spot reflection topographer (Cassini) in four study groups, namely a post myopic LASIK-treated Group A, a keratoconus Group B, a post-CXL keratoconus Group C, and a control Group D of routine healthy patients. Three separate, maps were obtained employing the Cassini, enabling investigation of the intra-individual repeatability by standard deviation. Additionally we investigated in all groups,the Klyce surface irregularity indices for keratoconus, the SAI (surface asymmetry index) and the SRI (surface regularity index). Results Flat keratometry repeatability was 0.74±0.89 (0.03 to 5.26) diopters (D) in the LASIK Group A, 0.88±1.45 (range minimum to maximum, 0.00 to 7.84) D in the keratoconic Group B, and 0.71±0.94 (0.02 to 6.23) D in the cross-linked Group C. The control Group D had flat keratometry repeatability 0.36±0.46 (0.00 to 2.71) D. Steep keratometry repeatability was 0.64±0.82 (0.01 to 4.81) D in the LASIK Group A, 0.89±1.22 (0.02 to 7.85) D in the keratoconic Group B, and 0.93±1.12 (0.04 to 5.93) D in the cross-linked Group C. The control Group D had steep keratometry repeatability 0.41±0.50 (0.00 to 3.51) D. Axis repeatability was 3.45±1.62° (0.38 to 7.78°) for the LASIK Group A, 4.12±3.17° (0.02 to 12.13°) for the keratoconic Group B, and 3.20±1.99° (0.17 to 8.61°) for the cross-linked Group C. The control Group D had axis repeatability 2.16±1.39° (0.05 to 5.86°). The SAI index measurement repeatability was 0.33±0.40 (0.01 to 2.31) in the post-LASIK Group A, 0.39±0.75 (0.00 to 7.15) in the keratoconic Group B, and 0.43±0.56 (0.05 to 3.50) in the keratoconus post-CXL Group C. The control group had SAI measurement repeatability of 0.26±0.30 (0.00 to 2.39). The SRI index repeatability was 0.22±0.17 (0.01 to 0.96) for post-LASIK Group A, 0.20±0.18 (0.00 to 1.07) in keratoconic Group B, and 0.13±0.09 (0.00 to 0.45) in the keratoconus post-CXL Group C. The control Group D had SRI measurement repeatability of 0.23±0.16 (0.00 to 0.75). Conclusion This novel corneal topography device appears to offer very high specificity in estimating corneal keratometry and specific corneal irregularity indices, even in topographically challenging corneas such as LASIK treated, keratoconic, and cross-linked.
Collapse
Affiliation(s)
- Anastasios John Kanellopoulos
- LaserVision.gr Clinical and Research Eye Institute, Athens, Greece ; New York University Medical School, New York, NY, USA
| | - George Asimellis
- LaserVision.gr Clinical and Research Eye Institute, Athens, Greece
| |
Collapse
|
18
|
OCT-Derived Comparison of Corneal Thickness Distribution and Asymmetry Differences Between Normal and Keratoconic Eyes. Cornea 2014; 33:1274-81. [DOI: 10.1097/ico.0000000000000275] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
19
|
Kanellopoulos AJ, Asimellis G. Clinical Correlation between Placido, Scheimpflug and LED Color Reflection Topographies in Imaging of a Scarred Cornea. Case Rep Ophthalmol 2014; 5:311-7. [PMID: 25408671 PMCID: PMC4224253 DOI: 10.1159/000365962] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
This case report aims to evaluate safety, efficacy and feasibility of anterior surface imaging by a novel point-source reflection topographer, in comparison to four other corneal imaging modalities. A 17-year-old female patient, clinically diagnosed with chronic herpetic keratitis in her left eye was imaged by a novel multicolored-spot reflection topography system. We comparatively investigated elevation and curvature maps between the novel topographer and established Placido disk topography and Scheimpflug tomography systems. Pachymetry maps were compared between the Scheimpflug system and anterior-segment optical coherence tomography system. The Placido system failed to properly register the abnormal anterior surface due to incomplete mire registration, while the Scheimpflug topometry device imaged the anterior surface properly, but not the posterior (due to media opacity), and thus pachymetry was highly irregular and erroneous in this case. Imaging of corneas infected with herpes simplex virus keratitis has been rare; we have not identified any such documentation in the peer review literature in the last 10 years. This novel multicolored-spot reflection topography imaging may offer successful corneal imaging in cases where established clinical topography systems may fail to produce accurate reconstruction of the corneal shape. This is an important case demonstrating exceptional clinical feasibility in such rare cases offered by a newly introduced technology in ophthalmic imaging.
Collapse
|