1
|
Park J, Rittiphairoj T, Wang X, E JY, Bicket AK. Device-modified trabeculectomy for glaucoma. Cochrane Database Syst Rev 2023; 3:CD010472. [PMID: 36912740 PMCID: PMC10010250 DOI: 10.1002/14651858.cd010472.pub3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/14/2023]
Abstract
BACKGROUND Glaucoma is an optic neuropathy that leads to visual field defects and vision loss. It is the second leading cause of irreversible blindness in the world. Treatment for glaucoma aims to reduce intraocular pressure (IOP) to slow or prevent further vision loss. IOP can be lowered with medications, laser, or incisional surgery. Trabeculectomy is a surgical approach which lowers IOP by shunting aqueous humor to a subconjunctival bleb. Device-modified trabeculectomy techniques are intended to improve the durability and safety of this bleb-forming surgery. Trabeculectomy-modifying devices include the Ex-PRESS, the XEN Gel Stent, the PreserFlo MicroShunt, as well as antifibrotic materials such as Ologen, amniotic membrane, expanded polytetrafluoroethylene (ePTFE) membrane, Gelfilm and others. However, the comparative effectiveness and safety of these devices are uncertain. OBJECTIVES To evaluate the benefits and harms of different devices as adjuncts to trabeculectomy on IOP control in eyes with glaucoma compared to standard trabeculectomy. SEARCH METHODS We used standard, extensive Cochrane search methods. The latest search was August 2021. SELECTION CRITERIA We included randomized controlled trials in participants with glaucoma comparing device-modified trabeculectomy techniques with standard trabeculectomy. We included studies that used antimetabolites in either or both treatment groups. DATA COLLECTION AND ANALYSIS We used standard Cochrane methods. Our primary outcomes were 1. change in IOP and 2. mean postoperative IOP at one year. Our secondary outcomes were 3. mean change in IOP from baseline, 4. mean postoperative IOP at any time point, 5. mean best-corrected visual acuity (BCVA), 6. visual field change, 7. quality of life, 8. proportion of participants who are drop-free at one year, 9. mean number of IOP lowering medications at one year, and 10. proportion of participants with complications. MAIN RESULTS Eight studies met our inclusion criteria, of which seven were full-length journal articles and one was a conference abstract. The eight studies included 961 participants with glaucoma, and compared two types of devices implanted during trabeculectomy versus standard trabeculectomy. Seven studies (462 eyes, 434 participants) used the Ex-PRESS, and one study (527 eyes, 527 participants) used the PreserFlo MicroShunt. No studies using the XEN Gel Stent implantation met our criteria. The studies were conducted in North America, Europe, and Africa. Planned follow-up periods ranged from six months to five years. The studies were reported poorly, which limited our ability to judge risk of bias for many domains. None of the studies explicitly masked outcome assessment. We rated seven studies at high risk of detection bias. Low-certainty of evidence from five studies showed that using the Ex-PRESS plus trabeculectomy compared with standard trabeculectomy may be associated with a slightly lower IOP at one year (mean difference (MD) -1.76 mmHg, 95% confidence interval (CI) -2.81 to -0.70; 213 eyes). Moderate-certainty of evidence from one study showed that using the PreserFlo MicroShunt may be associated with a slightly higher IOP than standard trabeculectomy at one year (MD 3.20 mmHg, 95% CI 2.29 to 4.11). Participants who received standard trabeculectomy may have a higher risk of hypotony compared with those who received device-modified trabeculectomy, but the evidence is uncertain (RR 0.73, 95% CI 0.46 to 1.17; I² = 38%; P = 0.14). In the subgroup of participants who received the PreserFlo MicroShunt, there was a lower risk of developing hypotony or shallow anterior chamber compared with those receiving standard trabeculectomy (RR 0.44, 95% CI 0.25 to 0.79; 526 eyes). Device-modified trabeculectomy may lead to less subsequent cataract surgery within one year (RR 0.46, 95% CI 0.27 to 0.80; I² = 0%). AUTHORS' CONCLUSIONS Use of an Ex-PRESS plus trabeculectomy may produce greater IOP reduction at one-year follow-up than standard trabeculectomy; however, due to potential biases and imprecision in effect estimates, the certainty of evidence is low. PreserFlo MicroShunt may be inferior to standard trabeculectomy in lowering IOP. However, PreserFlo MicroShunt may prevent postoperative hypotony and bleb leakage. Overall, device-modified trabeculectomy appears associated with a lower risk of cataract surgery within five years compared with standard trabeculectomy. Due to various limitations in the design and conduct of the included studies, the applicability of this evidence synthesis to other populations or settings is uncertain. Further research is needed to determine the effectiveness and safety of other devices in subgroup populations, such as people with different types of glaucoma, of various races and ethnicity, and with different lens types (e.g. phakic, pseudophakic).
Collapse
Affiliation(s)
- Junghyun Park
- Department of Ophthalmology, Inje University Seoul Paik Hospital, Seoul, Korea, South
| | - Thanitsara Rittiphairoj
- Department of Ophthalmology, University of Colorado Denver Anschutz Medical Campus, Aurora, Colorado, USA
| | - Xue Wang
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Jian-Yu E
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Amanda K Bicket
- Ophthalmology & Visual Sciences, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
2
|
Shin J, Hur J, Lee JE, Kang YJ, Kim SJ, Kim S, Choi HY. The Efficacy of Atelocollagen to Inhibit Fibrotic Proliferation in Tenon Tissue: In vitro Study. Ophthalmic Res 2022; 66:86-98. [PMID: 35952635 DOI: 10.1159/000525762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 05/09/2022] [Indexed: 11/19/2022]
Abstract
INTRODUCTION The aim of the study was to evaluate the safety and efficacy of atelocollagen in preventing the fibrotic change of human tenon tissue induced by transforming growth factor β1 (TGFβ1). METHODS Primary cultured human Tenon's fibroblasts (HTFs) were incubated with TGFβ1 alone and with various concentrations of atelocollagen, respectively. Cell viability was measured by Cell Counting Kit-8 (CCK-8). The mRNA levels of α-smooth muscle actin (α-SMA), vimentin, fibronectin, zonular occludens scaffolding protein (ZO-1), cellular communication network factor 2 (CCN2), and interleukin 6 (IL-6) were measured by quantitative reverse transcription polymerase chain reaction, Western blot, and immunofluorescence analysis. Wound healing assay and collagen contraction assay were additionally evaluated for identifying the inhibitory effect of atelocollagen in HTFs. To elucidate the mechanism by which atelocollagen affects HTF proliferation, the phospho-extracellular-signal-regulated kinases (pERK)/total-extracellular-signal-regulated kinases (tERK), phospho-focal adhesion kinase (pFAK)/total-focal adhesion kinase (tFAK), and pSmad3/tSmad3 protein expression ratios were measured by Western blot. RESULTS The safety of atelocollagen in HTF was identified by CCK-8 analysis. The expression of α-SMA and vimentin in HTFs treated with 0.023% and 0.046% atelocollagen significantly decreased at both mRNA and protein levels, while that of ZO-1 in 0.046% atelocollagen increased compared with TGFβ1-treated cells. The protein expression of fibronectin, CCN2, and IL-6 in HTFs treated with 0.023% and 0.046% atelocollagen significantly decreased. The immunofluorescence microscopy of α-SMA and ZO-1 showed results similar to those of the Western blot. In the wound-scratch assays, cell migration was significantly attenuated in HTFs treated with 0.005% atelocollagen. Atelocollagen at 0.005, 0.011, and 0.023% significantly inhibited the gel contraction induced by TGFβ1 at both 24 h and 48 h. The increase in pERK/tERK and pSmad3/tSmad3 protein expression ratios in TGFβ1-treated HTFs significantly decreased after treatment with 0.023 and 0.046% atelocollagen. CONCLUSION Since atelocollagen gel effectively suppresses the proliferation of HTFs in TGFβ1-induced transdifferentiation, it may be a potential therapeutic agent in glaucoma surgery.
Collapse
Affiliation(s)
- Jonghoon Shin
- Department of Ophthalmology, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Jin Hur
- Department of Convergence Medicine, Pusan National University School of Medicine, Yangsan, Republic of Korea
- PNU GRAND Convergence Medical Science Education Research Center, Pusan National University School of Medicine, Yangsan, Republic of Korea
| | - Ji Eun Lee
- Department of Ophthalmology, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Yoon Jeong Kang
- Department of Convergence Medicine, Pusan National University School of Medicine, Yangsan, Republic of Korea
| | - Soo Jin Kim
- Department of Ophthalmology, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea
| | - Sangyoon Kim
- Department of Ophthalmology, Pusan National University School of Medicine, Yangsan, Republic of Korea
| | - Hee-Young Choi
- Department of Ophthalmology, Pusan National University School of Medicine, Busan, Republic of Korea
- Medical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| |
Collapse
|
3
|
Kornmann HL, Fellman RL, Smith OU, Godfrey DG, Butler MR, Grover DS. Outcomes of bleb revision with ologen following filtering glaucoma surgery. Eur J Ophthalmol 2021; 32:2241-2248. [PMID: 34747204 DOI: 10.1177/11206721211053503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE This study reports long-term outcomes of bleb revision with ologen™ Collagen Matrix (Aeon Astron Europe BV, the Netherlands) for the surgical management of various bleb-related issues including persistent bleb leaks with or without associated hypotony, bleb dysesthesia, overhanging blebs, or hypotony after filtering glaucoma surgery. MATERIALS AND METHODS A retrospective chart review was performed for patients who underwent ologen bleb revision from 2012 to 2019 at Glaucoma Associates of Texas. RESULTS The study included 23 eyes of 22 patients undergoing bleb revision with the ologen implant. Mean age was 74.0 ± 11.3 years, 16 (69.6%) were female, and 13 (56.5%) were White. Indications for bleb revision included bleb leak (78.3%), dysesthesia (13.0%), and hypotony from an overfiltering bleb (8.7%). Mean preoperative intraocular pressure was 6.8 ± 4.1 mmHg and the number of medications was 0.3 ± 0.9. Median follow-up was 24 months (range: 12-84 months); all patients had at least 12 months of follow-up. At 1 year, mean intraocular pressure was 10.9 ± 4.6 mmHg on 0.2 ± 0.5 medications, and at last follow-up, mean intraocular pressure was 10.4 ± 3.6 mmHg on 0.3 ± 0.7 medications. Bleb morphology remained low, diffuse, and posterior. One patient developed kissing choroidal effusions requiring surgical drainage with subsequent stabilization of intraocular pressure and bleb function, and three patients required additional surgery due to persistent leaks or bleb failure; there were no other vision-threatening complications. CONCLUSIONS Use of the ologen implant during surgical bleb revision is a useful surgical technique that confers long-term improvements in bleb morphology and stability of function.
Collapse
|
4
|
Krishnadas R. Commentary: Implantable collagen devices in optimizing filtering success - The holy grail? Indian J Ophthalmol 2021; 69:2739-2740. [PMID: 34571625 PMCID: PMC8597440 DOI: 10.4103/ijo.ijo_1304_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- R Krishnadas
- Glaucoma Services, Aravind Eye Care System, Madurai, Tamil Nadu, India
| |
Collapse
|
5
|
Russ H, Maestrini HA, Coelho LF, Balbino M, Seixas RCS. The use of Ologen Collagen Matrix implants to treat ocular hypotony developing after trabeculectomy: A case series. Eur J Ophthalmol 2021; 32:1513-1517. [PMID: 34120492 DOI: 10.1177/11206721211023314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE Late hypotony is an undesirable and challenging complication of glaucoma surgery. We describe our use of the Ologen Collagen Matrix to treat late hypotony developing after trabeculectomy. STUDY DESIGN A retrospective study performed at three eye surgery centers in Brazil. PARTICIPANTS Eighteen patients who underwent 19 eye surgeries. INTERVENTION Subconjunctival Ologen was implanted at the trabeculectomy sites to treat over-filtering or leaking blebs in patients experiencing late hypotony after trabeculectomy (obtained 6 months after glaucoma surgery). The primary outcome was the intraocular pressure (IOP); we gathered preoperative data records from 19 Ologen treated eyes and days 1, 7, 30, 60, and 180 postoperatively. The secondary outcomes included visual acuity and macular thickness measured via optical coherence tomography; we compared preoperative data to subsequent ones up to sixth-month-evolution. RESULTS Over the 6-month period, the IOP rose from 2.89 ± 1.59 mmHg preoperatively to 8.21 ± 3.46 mmHg (p = 0.0001). Visual acuity improved from 0.33 ± 0.29 to 0.21 ± 0.31 LogMar (p = 0.0013). Macular thickness fell from 325.62 ± 58.7 to 283.08 ± 47.35 µm (p = 0.0097). We encountered two complications: one related to suture dehiscence following an ocular trauma and one instance of transitory choroidal detachment. CONCLUSION Subconjunctival Ologen implants preserved bleb function and successfully treated post-trabeculectomy hypotony as revealed by data collected at the 6-month follow-up. Longer follow-up is necessary to confirm long-term efficacy and safety. There are no financial conflicts of interest to disclose.
Collapse
Affiliation(s)
- Heloisa Russ
- Universidade Federal do Paraná, Curitiba, Paraná, Brazil
| | | | | | - Marcos Balbino
- Centro Universitário São Camilo, São Paulo, São Paulo, Brazil
| | | |
Collapse
|
6
|
Abstract
How to cite this article: Dada T, Ramesh P, Sethi A, et al. Ethics of Glaucoma Widgets. J Curr Glaucoma Pract 2020;14(3):77–80.
Collapse
Affiliation(s)
- Tanuj Dada
- Department of Ophthalmology, Dr RP Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Priyanka Ramesh
- Department of Ophthalmology, Dr RP Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Anin Sethi
- Department of Ophthalmology, Dr RP Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Shibal Bhartiya
- Glaucoma Services, Department of Ophthalmology, Fortis Memorial Research Institute, Gurugram, Haryana, India
| |
Collapse
|
7
|
Atalay E, Yu DJ, Nongpiur ME. When to use anterior segment optical coherence tomography. EXPERT REVIEW OF OPHTHALMOLOGY 2020. [DOI: 10.1080/17469899.2020.1767596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Eray Atalay
- Department of Ophthalmology, Eskisehir Osmangazi University Faculty of Medicine, Turkey
| | - Daryle Jason Yu
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
| | - Monisha Esther Nongpiur
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore, Singapore
| |
Collapse
|
8
|
Wlaź A, Wilkos‐Kuc A, Rozegnał‐Madej A, Żarnowski T. Phacotrabeculectomy using collagen matrix implant (Ologen ® ) versus mitomycin C: a prospective randomized controlled trial. Acta Ophthalmol 2019; 97:e817-e826. [PMID: 30924600 DOI: 10.1111/aos.14102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Accepted: 03/05/2019] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare the efficacy and safety of collagen matrix implant (Ologen® ; OLO) with mitomycin C (MMC) in phacotrabeculectomy. METHODS Prospective, single-centre, nonblinded, randomized controlled trial. A total of 53 eyes of 45 patients were enrolled in the study protocol with 27 eyes randomly assigned to OLO and 26 to MMC. The follow-up was 12 months. The primary outcome measure was mean change from baseline intraocular pressure (IOP) in both groups after 12 months. The secondary outcome measures were cumulative success rates at 12 months with Kaplan-Meier analysis, change in number of medications, change in best corrected visual acuity (BCVA), and bleb morphology assessed using Moorfields Bleb Grading System and anterior segment swept-source optical coherence tomography. RESULTS The mean IOP decreased from 26.4 ± 6.1 mmHg to 13.7 ± 3.8 in the OLO group and from 23.4 ± 3.6 mmHg to 13.3 ± 2.8 in the MMC group at 1 year without significant intergroup differences. At 1 year, the overall success rates were 92.6% and 92.3% in the OLO and MMC groups, respectively. There were no significant differences in the overall success rates, BCVA, number of medications, morphology of the filtering blebs and rate of complications at the end of the follow-up. CONCLUSION Ologen (OLO) provides similar surgical outcomes in phacotrabeculectomy compared with adjunctive MMC. It may be a new, safe and effective alternative to MMC for combined phacoemulsification and trabeculectomy surgery.
Collapse
Affiliation(s)
- Aleksandra Wlaź
- Department of Diagnostics and Microsurgery of Glaucoma Medical University Lublin Poland
| | - Agnieszka Wilkos‐Kuc
- Department of Diagnostics and Microsurgery of Glaucoma Medical University Lublin Poland
| | | | - Tomasz Żarnowski
- Department of Diagnostics and Microsurgery of Glaucoma Medical University Lublin Poland
| |
Collapse
|
9
|
Abstract
AIM To evaluate the efficacy and safety of trabeculectomy (Trab) with mitomycin-C (MMC) versus Trab with implant. METHODS Studies published in different languages were retrieved by systematically searching Embase, PubMed, Cochrane library, China Biology Medicine disc, and Google Scholar from 1966 to April 2018, as well as manually examining the references of the original articles. The outcome measures of efficacy covered intraocular pressure, glaucoma medications reductions, and success rate. Safety evaluation was measured by relative ratio of complications. RESULTS A total of 11 studies involving 443 participants were covered in this meta-analysis. The weighted mean difference (WMD) in the percentage of intraocular pressure (IOP) reduction (IOPR%) comparing Ologen group with MMC group was -3.69 (95% CI: -6.70 to -0.68) at 1 month, -2.69 (-5.17 to -0.21) at 3 months, -3.67 (-6.09 to -1.25)at 6 months, -3.24 (-6.08 to -0.41) at 12 months, 1.24 (-9.43 to 11.90) at 24 months, and 1.10 (-10.11 to 12.31) at 60 months, which showed that there was statistically significant difference at 1,3, 6, and12 months after the surgery. A significantly higher incidence of postsurgery hypotony (0.64 (95% Cl: 0.42 to 0.98)) and suture lysis (0.30 (95% CI: 0.10-0.93)) was observed in MMC group. However, there was no significant difference in the reduction in glaucoma medications, success rate, and incidence of other complications.Trab with 0.2 mg/mL MMC presented higher rates of complete success compared with Trab with 0.4 mg/mL MMC (P = .01). CONCLUSION Trab with MMC was associated with a higher IOP-lowering efficacy and a higher incidence of postsurgery hypotony and suture lysis in contrast to that of Trab with Ologen.
Collapse
|
10
|
Mamikonyan VR, Fisenko NV. [Glaucoma surgery: from traditional filtration techniques to modern principles of bioengineering]. Vestn Oftalmol 2018; 134:111-117. [PMID: 30499548 DOI: 10.17116/oftalma2018134051111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The article reviews the history of glaucoma surgery and analyses the connection between the accumulation of knowledge on glaucoma progression and the emergence of effective surgical treatment methods based on glaucoma pathogenesis. It also describes modern principles of preventing filtering bleb scarring. Particular attention is devoted to biodegradable collagen matrix implants.
Collapse
Affiliation(s)
- V R Mamikonyan
- Research Institute of Eye Diseases, 11A Rossolimo St., Moscow, Russian Federation, 119021
| | - N V Fisenko
- Research Institute of Eye Diseases, 11A Rossolimo St., Moscow, Russian Federation, 119021
| |
Collapse
|
11
|
Structural Reversal of Disc Cupping After Trabeculectomy Alters Bruch Membrane Opening-Based Parameters to Assess Neuroretinal Rim. Am J Ophthalmol 2018; 194:143-152. [PMID: 30053469 DOI: 10.1016/j.ajo.2018.07.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 07/13/2018] [Accepted: 07/15/2018] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To assess the impact of trabeculectomy for glaucoma on morphometric neuroretinal parameters of the optic nerve head (ONH) using spectral-domain optical coherence tomography (SD-OCT). DESIGN Retrospective, interventional case series. METHODS Participants: Eighty-eight eyes of 88 patients who underwent trabeculectomy with mitomycin C in 2016. INTERVENTION All patients underwent trabeculectomy in 1 eye (study eye) and had evaluable SD-OCT examinations of the ONH to measure neuroretinal tissue before and at least at 1 of the 3-, 6-, and 12-month follow-up time points after surgery. MAIN OUTCOME MEASURES Longitudinal change in Bruch membrane opening minimum rim width (BMO-MRW), Bruch membrane opening minimum rim area (BMO-MRA), peripapillary retinal nerve fiber layer (RNFL) thickness, intraocular pressure (IOP), and mean deviation in perimetry. RESULTS In study eyes, BMO-MRW significantly increased postsurgically comparing baseline and follow-up examinations at 3 months (P = .012), at 6 months (P = .007), and at 1 year (P = .010) after trabeculectomy. The increase in BMO-MRW 6 months after surgery correlated with IOP reduction (r = 0.48; P = .001). BMO-MRA showed an equal increase (P ≤ .034). RNFL thickness remained stable between baseline and follow-up at 3, 6, and 12 months and showed a moderate loss after 18 months (P = .021) of follow-up. CONCLUSIONS Structural reversal of disc cupping after trabeculectomy markedly influences Bruch membrane opening-based parameters for up to more than 1 year. Improvement in morphometry seems to correlate with the reduction of IOP while visual field function appears not to be influenced. In longitudinal follow-up of glaucoma patients by SD-OCT, evaluation of BMO-based parameters necessitates to reflect bias caused by surgery.
Collapse
|
12
|
Sen M, Midha N, Sidhu T, Angmo D, Sihota R, Dada T. Prospective Randomized Trial Comparing Mitomycin C Combined with Ologen Implant versus Mitomycin C Alone as Adjuvants in Trabeculectomy. ACTA ACUST UNITED AC 2018; 1:88-98. [DOI: 10.1016/j.ogla.2018.07.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 07/19/2018] [Accepted: 07/25/2018] [Indexed: 11/16/2022]
|
13
|
Mercieca KJ, Fenerty CH, Steeples LR, Drury B, Bhargava A. Precipitants of 5-Fluorouracil in Trabeculectomy Bleb Management: A Comparative Laboratory Study. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
14
|
Aquino MC, Lim D, Chew PTK. Micropulse P3™ (MP3) Laser for Glaucoma: An Innovative Therapy. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1244] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
15
|
Albis-Donado O, Bhartiya S, Gil-Reyes M, Casale-Vargas G, Arreguin-Rebollar N, Kahook MY. Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude. J Curr Glaucoma Pract 2018; 12:40-44. [PMID: 29861581 PMCID: PMC5981092 DOI: 10.5005/jp-journals-10028-1242] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Accepted: 12/09/2017] [Indexed: 11/23/2022] Open
Abstract
Introduction To ascertain differences in intraocular pressure (IOP) measurement and their repeatability between dynamic contour tonometry (DCT) and Goldmann/Perkins applanation tonometry (GAT) at two different atmospheric pressures. Materials and methods Forty-one eyes of 41 healthy consenting subjects were enrolled for this observational, cross-sectional study. Pachymetry and IOP measurements with DCT and GAT for both eyes of each subject at Acapulco (0 m from sea level) and at Mexico City (2,234 m from sea level) were done by the same observer. The IOP was compared between tonometers at each of the altitudes, and also for repeatability of each tonometer at different altitudes. Pearson's correlation coefficient and Bland-Altman plots were used to assess reliability of measurements and their differences at the two altitudes. Results The mean age of patients was 41.7 (28-66 years); 22 were females. Mean IOP with DCT was 16.1 ± 2.2 mm Hg at sea level and 15.9 ± 2.1 mm Hg at 2,234 m above sea level, not a significant difference. Mean GAT IOP at the two altitudes was 13.1 ± 1.8 and 11.5 ± 1.7 mm Hg respectively, a statistically sig -nificant difference. In contrast, central corneal thickness (CCT) was not significantly changed (548.3 to 549.4 μm, p = 0.496). Conclusion Repeatability of single-observer measurements with GAT remains clinically acceptable, but not at different altitudes. The DCT seems to more consistently measure a similar IOP at different altitudes in the same subjects. The two tonometers may not be used interchangeably in the serial follow-up of patients at any of the altitudes.How to cite this article: Albis-Donado O, Bhartiya S, Gil-Reyes M, Casale-Vargas G, Arreguin-Rebollar N, Kahook MY. Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude. J Curr Glaucoma Pract 2018;12(1):40-44.
Collapse
Affiliation(s)
- Oscar Albis-Donado
- Associate Professor, Department of Ophthalmology, Instituto Mexicano de Oftalmologia, Queretaro, Mexico and Omesvi Diagnostic Group Mexico City, Mexico
| | - Shibal Bhartiya
- Senior Consultant, Department of Ophthalmology, Glaucoma Facility, Fortis Memorial Research Institute, Gurugram, Haryana, India
| | - Marina Gil-Reyes
- Ophthalmologist, Department of Cornea and Uveitis Section, Omesvi Diagnostic Group, Mexico City, Mexico
| | - Giovanna Casale-Vargas
- Ophthalmologist, Department of Cornea and Uveitis Section, Omesvi Diagnostic Group, Mexico City, Mexico
| | - Nancy Arreguin-Rebollar
- Ophthalmologist, Department of Cornea and Uveitis Section, Omesvi Diagnostic Group, Mexico City, Mexico
| | - Malik Y Kahook
- Professor, Department of Ophthalmology, School of Medicine, University of Colorado, Denver, Colorado, USA
| |
Collapse
|
16
|
Alaghband P, Rodrigues IA, Goyal S. Phacoemulsification with Intraocular Implantation of Lens, Endocyclophotocoagulation, and Endoscopic-Goniosynechialysis (PIECES): A Combined Technique for the Management of Extensive Synechial Primary Angle Closure Glaucoma. J Curr Glaucoma Pract 2018; 12:45-49. [PMID: 29861582 PMCID: PMC5981093 DOI: 10.5005/jp-journals-10028-1243] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2017] [Accepted: 11/13/2017] [Indexed: 11/23/2022] Open
Abstract
Primary angle closure glaucoma (PACG) is more blinding (1 in 4 cases) than primary open angle glaucoma (1 in 10 cases). Cataract surgery is an effective initial treatment for majority of cases of PACG. However, cataract surgery alone may not be enough to control intraocular pressure (IOP) in cases with extensive synechial angle closure glaucoma. It is reported that glaucoma drainage surgery is needed in 12% of PACG cases after cataract surgery. Some experts combine cataract surgery with either goniosynechialysis (GSL) or endocyclophotocoagulation (ECP) to enhance IOP control. However, neither combination ensures complete success. We report three subjects with extensive synechia! angle closure in whom we facilitated a technique that combines lens extraction with ECP and endoscopic-GSL (PIECES). We demonstrated that this combined technique was a more effective and efficient method of achieving lower IOP in the presence of extensive synechial PACG. We believe that it addresses both the inflow and outflow of the aqueous humor simultaneously. Two out of three patients had good IOP control without medication and one patient needed one drop after a minimum 12 months of follow up. Furthermore, it may reduce the need for medical therapy and future more invasive glaucoma drainage surgery. How to cite this article: Alaghband P, Rodrigues IAS, Goyal S. Phacoemulsification with Intraocular Implantation of Lens, Endocyclophotocoagulation, and Endoscopic-Goniosynechialysis (PIECES): A Combined Technique for the Management of Extensive Synechial Primary Angle Closure Glaucoma. J Curr Glaucoma Pract 2018;12(1):45-49.
Collapse
Affiliation(s)
- Pouya Alaghband
- Registrar, Department of Ophthalmology, St Thomas Hospital, London United Kingdom
| | - Ian As Rodrigues
- Consultant, Department of Ophthalmology, St Thomas Hospital, London United Kingdom
| | - Saurabh Goyal
- Consultant, Department of Ophthalmology, St Thomas Hospital, London United Kingdom
| |
Collapse
|
17
|
Sheng Lim K, Garg A, Cheng J, Muthusamy K, Beltran-Agullo L, Barton K. Comparison of Short-term Postoperative Hypotony Rates of 23-gauge vs 25-gauge Needles in Formation of the Scleral Tract for Baerveldt Tube Insertion into the Anterior Chamber. J Curr Glaucoma Pract 2018; 12:36-39. [PMID: 29861580 PMCID: PMC5981091 DOI: 10.5005/jp-journals-10028-1241] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Accepted: 12/27/2017] [Indexed: 11/23/2022] Open
Abstract
Introduction To compare the early postoperative hypotony rates and intraocular pressure (IOP) in two groups of eyes using either 23-gauge (23G) or 25-gauge (25G) needle in the creation of the anterior chamber entry tract for Baerveldt tube. The primary outcome measure was incidence of hypotony, and secondary outcome measures included comparison of mean IOP and other early complications. Materials and methods Ours was a retrospective case review of consecutive patients who underwent 350 mm2 Baerveldt implantation in two units over a 2-year period. Data including IOP and complications were collected at 1 day, 1 week, and 1 month following surgery from patients’ notes. Statistical analysis between groups was determined using the unpaired 2-tailed f-test for continuous variables and chi-squared test for categorical variables. Statistical significance was defined at the 0.05 level. Results A total of 58 eyes of 58 patients were included in this study. Preoperative mean IOP in the 25G group was significantly higher (26.4 ± 6.8 mm Hg) when compared with the 23G group (21.6 ± 4.0 mm Hg) (p = 0.002). The mean postoperative IOP remained significantly higher in the 25G group at day 1 (p=0.004), week 1 (p = 0.008), but not at month 1 (p = 0.744). Four patients in the 23G group had hypotony within 1 month postsurgery compared with no cases in the 25G group (chi-squared test p = 0.038). Conclusion There was a significantly higher risk of early hypotony and lower IOP in the larger 23G group at days 1 and 7, although the IOP was similar in both groups by 1 month. Clinical significance After all glaucoma drainage device (GDD) tube implantation, regardless of which needle is used to create the tract, the entry site should always be checked with 2% fluorescein drop and 10.0 nylon suture is used with or without autologous Tenon’s tissue to close any leakage. How to cite this article: Lim KS, Garg A, Cheng J, Muthusamy K, Beltran-Agullo L, Barton K. Comparison of Short-term Postoperative Hypotony Rates of 23-gauge vs 25-gauge Needles in Formation of the Scleral Tract for Baerveldt Tube Insertion into the Anterior Chamber. J Curr Glaucoma Pract 2018;12(1):36-39.
Collapse
Affiliation(s)
- Kin Sheng Lim
- Consultant, Department of Ophthalmology, Guys & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Anurag Garg
- Specialist Registrar, Department of Ophthalmology, Glaucoma Service, St Thomas' Hospital, London, United Kingdom
| | - Jason Cheng
- Fellow, Department of Ophthalmology, Glaucoma Service, St Thomas' Hospital, London, United Kingdom
| | - Kirithika Muthusamy
- Specialist Registrar, Department of Ophthalmology, Moorfields Eye Hospital London, United Kingdom
| | - Laura Beltran-Agullo
- Fellow, Department of Ophthalmology, Glaucoma Service, St Thomas' Hospital, London, United Kingdom
| | - Keith Barton
- Consultant, Department of Ophthalmology, Moorfields Eye Hospital London, United Kingdom
| |
Collapse
|
18
|
Trevino R, Sponsel WE, Majcher CE, Allen J, Rabin J. Association of Diopsys® Short-duration Transient Visual Evoked Potential Latency with Visual Field Progression in Chronic Glaucoma. J Curr Glaucoma Pract 2018; 12:29-35. [PMID: 29861579 PMCID: PMC5981090 DOI: 10.5005/jp-journals-10028-1240] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2017] [Accepted: 12/16/2017] [Indexed: 11/23/2022] Open
Abstract
Aim To determine the association of Diopsys® NOVA-LX amplitude and latency abnormality scores with perimetric staging of chronic glaucoma, and to explore potential single-visit short-duration transient visual evoked potential (SD-tVEP) trend detection ability utilizing Humphrey 30-2 field progression data. Materials and methods Setting: Glaucoma subspecialty clinic. Participants: Treated adult chronic glaucoma patients undergoing SD-tVEP evaluation. Main outcome measures: (1) Proportion of eyes designated as suspect or abnormal by the NOVA-LX multifactorial algorithm were determined as a function of glaucoma severity using the most recent Humphrey visual field analyzer (HVFA) 30-2 field. (2) Association between long-term HVFA-guided progression analysis (GPA) annual slopes and SD-tVEP abnormality was assessed to determine whether a single VEP test might help to identify eyes more prone to progressive visual field (VF) loss. Results One hundred and thirty-three eyes of 84 patients (mean age 68 years) were analyzed. The SD-tVEP abnormality increased proportionately with severity of VF loss under high-contrast (Hc) test conditions for both latency (p = 0.001) and amplitude (p < 0.01). The HVFA progression analysis printouts existed for 91 eyes (mean 12.3 fields per eye/range 5-18). Nearly three-quarters (72.5%) of eyes with mean annual HVFA progression >0.7 dB/year (n = 29) had single-visit VEP latency abnormalities. Fewer than half (46.7%) of the remainder (n = 62) showed latency abnormality. Mean progression for eyes with abnormal vs normal VEP latency was -0.87 ± 0.3 dB/year vs -0.32 ± 0.4 dB/year. Conclusion Diopsys NOVA-LX Hc latency abnormality shows strong association with VF loss among a diverse population of clinical patients undergoing active treatment for chronic glaucoma, and appears likely to afford clinically useful trend-detecting test. Clinical significance The SD-tVEP has the potential to serve as a single-visit clinical indicator to identify glaucoma patients at high risk for VF progression. How to cite this article: Trevino R, Sponsel WE, Majcher CE, Allen J, Rabin J. Association of Diopsys® Short-duration Transient Visual Evoked Potential Latency with Visual Field Progression in Chronic Glaucoma. J Curr Glaucoma Pract 2018;12(1):29-35.
Collapse
Affiliation(s)
- Richard Trevino
- Optometrist, Rosenberg School of Optometry, University of the Incarnate Word, San Antonio, Texas, USA
| | - William E Sponsel
- Director, Professor and Consultant, Department of Ophthalmology, CLI Eyes of Africa Clinic and Surgery Center, Malawi, Africa; WESMDPA Baptist Medical Center Glaucoma Service, San Antonio, Texas; Department of Biomedical Engineering, University of Texas San Antonio, San Antonio, Texas; Rosenberg School of Optometry, University of the Incarnate Word, San Antonio, Texas, USA
| | - Carolyn E Majcher
- Optometrist, Rosenberg School of Optometry, University of the Incarnate Word, San Antonio, Texas, USA
| | - Joey Allen
- Optometrist, Rosenberg School of Optometry, University of the Incarnate Word, San Antonio, Texas, USA
| | - Jeffery Rabin
- Optometrist, Rosenberg School of Optometry, University of the Incarnate Word, San Antonio, Texas, USA
| |
Collapse
|
19
|
Tanito M, Sano I, Ikeda Y, Fujihara E. Patch Grafting Using an Ologen Collagen Matrix to Manage Tubal Exposure in Glaucoma Tube Shunt Surgery. Case Rep Ophthalmol 2018; 9:9-16. [PMID: 29643776 PMCID: PMC5892321 DOI: 10.1159/000485549] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Accepted: 11/22/2017] [Indexed: 11/19/2022] Open
Abstract
Purpose To report the results using an ologen Collagen Matrix as a patch graft in eyes with tubal exposure after tube shunt surgery. Case Reports Case 1 was an 82-year-old man with tubal exposure in his right eye 26 months after receiving a Baerveldt glaucoma implant. The tube was covered by surrounding conjunctival tissue combined with subconjunctival placement of an ologen Collagen Matrix as a patch graft. Two years after implantation, the tube was not exposed. Anterior-segment optical coherence tomography (AS-OCT) showed dense conjunctival tissue over the tube. Case 2 was an 82-year-old man with peripheral keratitis, anterior scleritis, and secondary glaucoma in the right eye who underwent tube shunt surgery using an Ahmed glaucoma valve and cataract surgery. Intraoperatively, scleritis-related scleral thinning prevented the tube from being covered fully by an autologous scleral flap. An ologen Collagen Matrix was placed over the scleral flap as a patch graft. Seventeen months after implantation, the tube was not exposed. Case 3 was a 52-year-old man with diabetic maculopathy and steroid-induced glaucoma in the right eye who underwent tube shunt surgery using an Ahmed glaucoma valve. Intraoperatively, a flap defect prevented the tube from being covered fully by an autologous scleral flap. An ologen Collagen Matrix was placed over the scleral flap as a patch graft. Three weeks postoperatively, AS-OCT showed thick subconjunctival tissue over the tube. Three months after implantation, the tube was not exposed. Conclusions The ologen Collagen Matrix can be used successfully as a patch graft to prevent and treat tubal exposure after tube shunt surgery.
Collapse
Affiliation(s)
- Masaki Tanito
- Division of Ophthalmology, Matsue Red Cross Hospital, Matsue, Japan
| | - Ichiya Sano
- Division of Ophthalmology, Matsue Red Cross Hospital, Matsue, Japan
| | - Yoshifumi Ikeda
- Division of Ophthalmology, Matsue Red Cross Hospital, Matsue, Japan
| | - Etsuko Fujihara
- Division of Ophthalmology, Matsue Red Cross Hospital, Matsue, Japan
| |
Collapse
|
20
|
Thangamathesvaran L, Crane E, Modi K, Khouri AS. Outcomes of Resident-versus attending-performed Tube Shunt Surgeries in a United States Residency Program. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1245] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
21
|
Outcomes of Trabeculectomy and Phacotrabeculectomy With Collagen Matrix Implant (Ologen) and Low-dose Mitomycin C: 2-Year Follow-up. J Glaucoma 2018; 27:50-54. [DOI: 10.1097/ijg.0000000000000818] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
J Lu L, Hall L, Liu J. Improving Glaucoma Surgical Outcomes with Adjunct Tools. J Curr Glaucoma Pract 2018; 12:19-28. [PMID: 29861578 PMCID: PMC5981089 DOI: 10.5005/jp-journals-10028-1239] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 11/09/2017] [Indexed: 11/23/2022] Open
Abstract
Conventional glaucoma surgeries, such as trabeculectomy and glaucoma drainage device (GDD) surgery, have been enhanced by surgeons to improve outcome and decrease complications. Over the last two decades, adjuncts, such as collagen matrix implants, fibrin adhesives, and amniotic membrane transplantation (AMT) have been found to be effective in modulating fibrosis and scarring during the wound-healing process, reducing postoperative inflammation, and repairing bleb leakage or conjunctival erosion. The use of these tools provides several advantages when used in trabeculectomy, GDD surgery, and surface reconstruction associated with glaucoma surgery complications. Their use will be discussed in this review. How to cite this article: Lu LJ, Hall L, Liu J. Improving Glaucoma Surgical Outcomes with Adjunct Tools. J Curr Glaucoma Pract 2018;12(1):19-28.
Collapse
Affiliation(s)
- Louise J Lu
- Medical Student, Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut, United States
| | - Laura Hall
- Ophthalmologist, Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut, United States
| | - Ji Liu
- Ophthalmologist, Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, Connecticut, United States
| |
Collapse
|
23
|
Dong J, Syed ZA, Fan K, Yahya AF, Melki SA. Potential Savings from Visit Reduction of Continuous Intraocular Pressure Monitoring. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1246] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
24
|
Eldaly ZH, Maasoud AA, Saad MS, Mohamed AA. Comparison between Ologen implant and different concentrations of Mitomycin C as an adjuvant to trabeculectomy surgery. Oman J Ophthalmol 2017; 10:184-192. [PMID: 29118494 PMCID: PMC5657161 DOI: 10.4103/ojo.ojo_199_2016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
CONTEXT: Trabeculectomy is the most common surgical procedure for treatment of glaucoma. To improve success rates, adjuvants were utilized as Mitomycin C (MMC) and Ologen implant. AIMS: This study aims to establish efficacy and safety of Ologen implant versus MMC in trabeculectomy. SETTING AND DESIGN: A prospective, comparative clinical study was conducted at the Department of Ophthalmology, Assiut University, between December 2014 and April 2016. SUBJECTS AND METHODS: Patients with primary open-angle glaucoma (OAG), primary narrow-angle glaucoma and secondary OAG were assigned equally to trabeculectomy with Ologen, 0.4 mg/mL or 0.2 mg/mL MMC. The study outcome measures were reduction in intra-ocular pressure (IOP), success rates, survival analysis, and rate of complications. STATISTICAL ANALYSIS USED: SPSS software Version 17.0 (SPSS, Inc., IL, USA) was utilized. RESULTS: Thirty eyes were included in the study. Mean baseline IOP in Ologen, MMC 0.4 and MMC 0.2 groups were 27.43 ± 2.97, 28.4 ± 3.24, and 27.56 ± 2.69 mmHg, respectively. At week 24 follow-up, mean IOP in Ologen, MMC 0.4 and MMC 0.2 groups were 18.55 ± 3.18, 16.2 ± 3.22, and 16.93 ± 3.04 mmHg, respectively. No significant inter-group difference was noticed at any visits. Complete success was achieved in 10%, 40%, and 30%, whereas incomplete success in 70%, 50%, and 60%, respectively in Ologen, MMC 0.4 and MMC 0.2 groups. No treatment group difference was reported by Kaplan–Meier analysis. Shallow anterior chamber occurred more in Ologen and MMC 0.4 groups. A single case of serous choroidal effusion had occurred in MMC 0.4 group. CONCLUSION: Ologen implant is a promising alternative to MMC for improving the success rate of trabeculectomy.
Collapse
Affiliation(s)
- Zeiad H Eldaly
- Department of Ophthalmology, Assiut University Hospitals, Assiut, Egypt
| | - Ali A Maasoud
- Department of Ophthalmology, Assiut University Hospitals, Assiut, Egypt
| | - Mohamed S Saad
- Department of Ophthalmology, Assiut University Hospitals, Assiut, Egypt
| | | |
Collapse
|
25
|
Pimentel E, Schmidt J. Is device-modified trabeculectomy better than classic surgery for treatment of glaucoma? Medwave 2017; 17:e7018. [PMID: 28863130 DOI: 10.5867/medwave.2017.07.7018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Accepted: 08/01/2017] [Indexed: 11/27/2022] Open
Abstract
Several techniques have emerged as complement or replacement for trabeculectomy, the standard surgery for glaucoma. Device-modified trabeculectomy is a recently developed technique whose results compared to the classical technique have not been fully defined. To answer this question, we used Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We identified eight systematic reviews including 34 studies overall. We extracted data from the systematic reviews, reanalyzed data of primary studies, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. We concluded device-modified trabeculectomy probably leads to greater overall success rate and may decrease intraocular pressure more than classical surgery. In addition, this technique would probably have a better safety profile than standard trabeculectomy.
Collapse
Affiliation(s)
- Eduardo Pimentel
- Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile; Proyecto Epistemonikos, Santiago, Chile
| | - Jimena Schmidt
- Proyecto Epistemonikos, Santiago, Chile; Departamento de Oftalmología, Facultad de Medicina, Pontificia Universidad Católica de Chile.. Address: Facultad de Medicina, Pontificia Universidad Católica de Chile, Diagonal Paraguay 362, Santiago Centro, Chile
| |
Collapse
|
26
|
Subconjunctival implantation of ologen Collagen Matrix to treat ocular hypotony after filtration glaucoma surgery. Eye (Lond) 2017; 31:1475-1479. [PMID: 28574500 DOI: 10.1038/eye.2017.98] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 04/13/2017] [Indexed: 11/09/2022] Open
Abstract
PurposeTo report the results of subconjunctival ologen Collagen Matrix implantation to manage ocular hypotony after filtration glaucoma surgery.Patients and methodsThis retrospective observational case series included 12 consecutive implantations of ologen in nine eyes of nine Japanese subjects (five men, four women; mean age±SD, 72.1±12.7 years) who underwent subconjunctival implantation of the device to treat hypotony after glaucoma filtration surgery. Demographic data and surgical results were collected by chart review.ResultsThe subjects included six patients who underwent trabeculectomy and three who underwent an EX-PRESS shunt surgery. The duration between the last glaucoma surgery and the initial ologen implantation was longer than 2 years in seven (78%) eyes. Bleb leakage in five (56%) eyes preoperatively stopped in all cases by 8 days after the device implantation. After the initial implantation, three (33.3%) eyes required a second implantation of ologen because of insufficient efficacy. After a mean follow-up of 12.6±6.8 months, the mean preoperative intraocular pressure (IOP) of 3.8±2.7 mmHg increased significantly (P=0.0001) to 9.0±3.2 mmHg; no eye required glaucoma medication to control the IOP. No vision-threatening complications developed in association with the treatment.ConclusionWhen conservative management failed, subconjunctival implantation of ologen Collagen Matrix in combination with bleb revision can be a useful therapeutic option for ocular hypotony after glaucoma filtration surgery.
Collapse
|
27
|
Outcomes of Trabeculectomy Augmented With Subconjunctival and Subscleral Ologen Implantation in Primary Advanced Glaucoma. J Glaucoma 2017; 26:8-14. [DOI: 10.1097/ijg.0000000000000537] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
Collagen matrix vs mitomycin-C in trabeculectomy and combined phacoemulsification and trabeculectomy: a randomized controlled trial. BMC Ophthalmol 2016; 16:217. [PMID: 28034308 PMCID: PMC5200961 DOI: 10.1186/s12886-016-0393-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2016] [Accepted: 11/24/2016] [Indexed: 11/20/2022] Open
Abstract
Background Antifibrotic agents are commonly utilized to enhance the success rates of trabeculectomy. Novel approaches to further improve success rates and reduce the risks of complications are needed. The purpose of this study was to compare intraocular pressure (IOP)-lowering efficacy and safety of trabeculectomy or combined phacoemulsification and trabeculectomy with mitomycin-C (MMC) vs. Collagen Matrix (CM). Methods A prospective, multicenter, randomized controlled trial was performed. Ninety-five eyes of 94 patients with uncontrolled glaucoma despite medical therapy, without previous incisional glaucoma surgery underwent trabeculectomy (85 eyes) or combined phacoemulsification and trabeculectomy (10 eyes) and were randomized to MMC or CM. One eye of each subject was analyzed. Patients were followed for 24 months. The criteria for complete success were IOP >5 and ≤21 mmHg with at least a 20% reduction below medicated baseline without additional glaucoma surgery or medications. The main outcome measures were complete success rates at 24 months with Kaplan-Meier analysis and incidence of adverse events. Results The baseline IOPs were 20.4 ± 6.0 mmHg and 21.2 ± 6.1 (mean ± standard deviation, p = 0.49) on 3.2 ± 1.1 and 3.1 ± 1.0 medications (p = 0.53) compared to 11.8 ± 5.2 and 12.8 ± 3.7 (p = 0.36) on 0.5 ± 0.8 and 0.6 ± 1.0 medications (p = 0.63) at 2 years in the MMC and CM groups, respectively. Kaplan-Meier analysis demonstrated complete success rates were similar in both groups at 24 months: 38.4 ± 7.6% with MMC and 56.2 ± 7.9% with CM (mean ± standard error, p = 0.112, log rank test); however, a significantly higher incidence of failure due to persistent hypotony was observed with MMC (p = 0.002). Conclusions Use of the CM implant at the time of trabeculectomy or combined phacoemulsification and trabeculectomy is associated with similar complete success rates compared to adjunctive MMC; however, the risk of persistent hypotony is higher with MMC. Trial registration ClinicalTrials.gov registration number NCT01440751. Registered 9/14/11 Electronic supplementary material The online version of this article (doi:10.1186/s12886-016-0393-z) contains supplementary material, which is available to authorized users.
Collapse
|
29
|
Abstract
BACKGROUND Glaucoma is an optic neuropathy that leads to vision loss and blindness. It is the second most common cause of irreversible blindness worldwide. The main treatment for glaucoma aims to reduce intraocular pressure (IOP) in order to slow or prevent further vision loss. IOP can be lowered with medications, and laser or incisional surgeries. Trabeculectomy is the most common incisional surgical procedure to treat glaucoma. Device-modified trabeculectomy is intended to improve drainage of the aqueous humor to lower IOP. Trabeculectomy-modifying devices include Ex-PRESS, Ologen, amniotic membrane, expanded polytetrafluoroethylene (E-PTFE) membrane, Gelfilm and others. However, the effectiveness and safety of these devices are uncertain. OBJECTIVES To assess the relative effectiveness, primarily with respect to IOP control and safety, of the use of different devices as adjuncts to trabeculectomy compared with standard trabeculectomy in eyes with glaucoma. SEARCH METHODS We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2014, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2014), EMBASE (January 1980 to December 2014), PubMed (1948 to December 2014), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 22 December 2014. SELECTION CRITERIA We included randomized controlled trials comparing devices used during trabeculectomy with trabeculectomy alone. We also included studies where antimetabolites were used in either or both treatment groups. DATA COLLECTION AND ANALYSIS We used standard procedures expected by Cochrane. MAIN RESULTS We found 33 studies that met our inclusion criteria, of which 30 were published as full-length journal articles and three as conference abstracts. Only five studies have been registered. The 33 studies included a total of 1542 participants with glaucoma, and compared five types of devices implanted during trabeculectomy versus trabeculectomy alone. Five studies reported the use of Ex-PRESS (386 participants), eight studies reported the use of Ologen (327 participants), 18 studies reported the use of amniotic membrane (726 participants), one study reported the use of E-PTFE (60 participants), and one study reported the use of Gelfilm (43 participants). These studies were conducted in North America, South America, Europe, Asia, and the Middle East. Planned participant follow-up periods ranged from three months to five years. The studies were reported poorly which limited our ability to judge risk of bias for many domains. Only two studies explicitly masked outcome assessment so, we rated 31 studies at high risk of detection bias.Low-quality evidence from three studies showed that use of Ex-PRESS compared with trabeculectomy alone may be associated with a slightly lower IOP at one year (mean difference (MD) -1.58 mm Hg, 95% confidence interval (CI) -2.74 to -0.42; 165 eyes). Cataract surgery and hyphema may be less frequent in the Ex-PRESS group than in the trabeculectomy-alone group (cataract surgery: risk ratio (RR) 0.32, 95% CI 0.14 to 0.74, 3 studies, low-quality evidence; hyphema: RR 0.33, 95% CI 0.12 to 0.94, 4 studies, low-quality evidence). The effect of whether Ex-PRESS prevents hypotony was uncertain (RR 0.92, 95% CI 0.63 to 1.33, 2 studies, very low-quality evidence). All these studies received funding from the device manufacturer.Very low-quality evidence from five studies suggests that use of Ologen compared with trabeculectomy alone is associated with slightly higher IOP at one year (MD 1.40 mm Hg, 95% CI -0.57 to 3.38; 177 eyes). The effect of Ologen on preventing hypotony was uncertain (RR 0.75, 95% CI 0.47 to 1.19, 5 studies, very low-quality evidence). Differences between the two treatment groups for other reported complications also were inconclusive.Low-quality evidence from nine studies suggests that use of amniotic membrane with trabeculectomy may be associated with lower IOP at one year compared with trabeculectomy alone (MD -3.92 mm Hg, 95% CI -5.41 to -2.42; 356 eyes). Low-quality evidence showed that use of amniotic membrane may prevent adverse events and complications, such as hypotony (RR 0.40, 95% CI 0.17 to 0.94, 5 studies, low-quality evidence).The report from the only E-PTFE study (60 eyes) showed no important differences for postoperative IOP at one year (MD -0.44 mm Hg, 95% CI -1.76 to 0.88) between the trabeculectomy + E-PTFE versus the trabeculectomy-alone groups. Hypotony was the only postoperative complication observed less frequently in the E-PTFE group compared to the trabeculectomy-alone group (RR 0.29, 95% CI 0.11 to 0.77).The one Gelfilm study reported uncertainty in the difference in IOP and complication rates between the two groups at one year; no further data were provided in the study report. AUTHORS' CONCLUSIONS Overall, the use of devices with standard trabeculectomy may help with greater IOP reduction at one-year follow-up than trabeculectomy alone; however, due to potential biases and imprecision in effect estimates, the quality of evidence is low. When we examined outcomes within subgroups based on the type of device used, our findings suggested that the use of an Ex-PRESS device or an amniotic membrane as an adjunct to trabeculectomy may be slightly more effective in reducing IOP at one year after surgery compared with trabeculectomy alone. The evidence that these devices are as safe as trabeculectomy alone is unclear. Due to various limitations in the design and conduct of the included studies, the applicability of this evidence synthesis to other populations or settings is uncertain. Further research is needed to determine the effectiveness and safety of other devices and in subgroup populations, such as people with different types of glaucoma, of various races and ethnicity, and with different lens types (e.g. phakic, pseudophakic).
Collapse
Affiliation(s)
- Xue Wang
- Johns Hopkins Bloomberg School of Public HealthDepartment of Epidemiology615 N. Wolfe StreetBaltimoreMarylandUSA21205
| | - Rabeea Khan
- UCLA ‐ Olive ViewInternal Medicine1445 Olive View DriveSylmarCaliforniaUSA91342
| | - Anne Coleman
- Jules Stein Eye Institute, UCLA100 Stein PlazaBox 957000Los AngelesCaliforniaUSACA 90095‐7000
| | | |
Collapse
|
30
|
Olson JL, Bhandari R, Groman-Lupa S, Velez-Montoya R. A nanopore membrane regulator device for laser modulated flow after glaucoma surgery. Biomed Microdevices 2015; 17:90. [PMID: 26272497 DOI: 10.1007/s10544-015-9985-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Glaucoma, the second most common cause of blindness in the world, is a multifactorial disease with several risk factors, of which intraocular pressure (IOP) is a primary contributing factor. Filtration surgery is one of the most effective means to significantly lower IOP compared to medical or laser treatments, and it is typically reserved for advanced disease. However, there are high rates of postoperative complications associated with the procedure, often from over- or under-filtration. To address these problems, the glaucoma drainage device regulator (GDDR) implant was developed to allow post-operative control of aqueous flow and IOP. The device, a tube with a nanopore membrane, is placed beneath the scleral flap. Postoperatively, the membrane surface can be ruptured with a laser to augment flow through the system. This feature allows adjustable control of aqueous flow and diminishes the risk of hypotony in the early postoperative period.
Collapse
Affiliation(s)
- Jeffrey L Olson
- Rocky Mountain Lions Eye Institute, University of Colorado School of Medicine, 1675 Aurora Court, Aurora, CO, 80045, USA,
| | | | | | | |
Collapse
|
31
|
Menda SA, Lowry EA, Porco TC, Stamper RL, Rubin MR, Han Y. Ex-PRESS outcomes using mitomycin-C, Ologen alone, Ologen with 5-fluorouracil. Int Ophthalmol 2014; 35:357-63. [DOI: 10.1007/s10792-014-9955-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Accepted: 05/20/2014] [Indexed: 01/23/2023]
|