van der Molen MC, Hartman JE, Vanfleteren LEGW, Kerstjens HAM, van Melle JP, Willems TP, Slebos DJ. Reduction of Lung Hyperinflation Improves Cardiac Preload, Contractility, and Output in Emphysema: A Prospective Cardiac Magnetic Resonance Study in Patients Who Received Endobronchial Valves.
Am J Respir Crit Care Med 2022;
206:704-711. [PMID:
35584341 DOI:
10.1164/rccm.202201-0214oc]
[Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
RATIONALE
Pulmonary hyperinflation in patients with Chronic Obstructive Pulmonary Disease (COPD) has been related to smaller cardiac chamber sizes and impaired cardiac function. Nowadays, bronchoscopic lung volume reduction (BLVR) with endobronchial valves is a treatment option to reduce pulmonary hyperinflation in patients with severe emphysema.
OBJECTIVES
We hypothesized that reduction of hyperinflation would improve cardiac preload in this patient group. In addition, we investigated whether the treatment would result in elevated pulmonary artery pressures due to pulmonary vascular bed reduction.
METHODS
We included patients with emphysema and severe hyperinflation (defined by a baseline residual volume >175% of predicted) who were eligible for BLVR with endobronchial valves. Cardiac magnetic resonance imaging was obtained one day prior to treatment and at eight week follow-up. Primary endpoint was cardiac preload, as measured by the right ventricle end-diastolic volume index (RVEDVI). As secondary endpoints, we measured indexed end-diastolic and end-systolic volumes of the right ventricle, left atrium, and left ventricle, pulmonary artery pressures, cardiac output, ejection fraction, and strain.
MEASUREMENTS AND MAIN RESULTS
Twenty-four patients were included. At eight week follow-up, RVEDVI was significantly improved (+7.9 ml/m2, SD 10.0, p=0.001). In addition to increased stroke volumes, we found significantly higher ejection fractions and strain measurements. Although cardiac output was significantly increased (+0.9L/min, SD 1.5, p=0.007), there were no changes in pulmonary artery pressures.
CONCLUSIONS
We found that reduction of hyperinflation using BLVR with endobronchial valves significantly improved cardiac preload, myocardial contractility, and cardiac output, without changes in pulmonary artery pressures. Clinical trial registered with ClinicalTrials.gov (NCT03474471).