• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623375)   Today's Articles (5111)   Subscriber (49407)
For: Torres R, Hochet B, Daoudi H, Carré F, Mosnier I, Sterkers O, Ferrary E, Nguyen Y. Atraumatic Insertion of a Cochlear Implant Pre-Curved Electrode Array by a Robot-Automated Alignment with the Coiling Direction of the Scala Tympani. Audiol Neurootol 2021;27:148-155. [PMID: 34284383 DOI: 10.1159/000517398] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 05/24/2021] [Indexed: 11/19/2022]  Open
Number Cited by Other Article(s)
1
Torres R, Daoudi H, Gu W, Breil E, Ferrary E, Sterkers O, Nguyen Y, Mosnier I. Exploring Trauma Patterns and Contributing Factors With Slim Straight Electrode Array After Cochlear Implantation. Otolaryngol Head Neck Surg 2024;171:521-529. [PMID: 38532540 DOI: 10.1002/ohn.737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/09/2024] [Accepted: 02/29/2024] [Indexed: 03/28/2024]
2
Concheri S, Brotto D, Ariano M, Daloiso A, Di Pasquale Fiasca VM, Sorrentino F, Coppadoro B, Trevisi P, Zanoletti E, Franchella S. Intraoperative Measurement of Insertion Speed in Cochlear Implant Surgery: A Preliminary Experience with Cochlear SmartNav. Audiol Res 2024;14:227-238. [PMID: 38525682 PMCID: PMC10961689 DOI: 10.3390/audiolres14020021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/18/2024] [Accepted: 02/19/2024] [Indexed: 03/26/2024]  Open
3
Pai I, Connor S, Komninos C, Ourselin S, Bergeles C. The impact of the size and angle of the cochlear basal turn on translocation of a pre-curved mid-scala cochlear implant electrode. Sci Rep 2024;14:1024. [PMID: 38200135 PMCID: PMC10781700 DOI: 10.1038/s41598-023-47133-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 11/09/2023] [Indexed: 01/12/2024]  Open
4
Derieppe A, Gendre A, Bourget-Aguilar K, Bordure P, Michel G. Comparative study of vestibular function preservation in manual versus robotic-assisted cochlear implantation. Cochlear Implants Int 2024;25:23-27. [PMID: 37985652 DOI: 10.1080/14670100.2023.2271221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
5
Robot-Assisted Electrode Insertion in Cochlear Implantation Controlled by Intraoperative Electrocochleography-A Pilot Study. J Clin Med 2022;11:jcm11237045. [PMID: 36498620 PMCID: PMC9737018 DOI: 10.3390/jcm11237045] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 11/21/2022] [Indexed: 12/03/2022]  Open
6
Starovoyt A, Quirk BC, Putzeys T, Kerckhofs G, Nuyts J, Wouters J, McLaughlin RA, Verhaert N. An optically-guided cochlear implant sheath for real-time monitoring of electrode insertion into the human cochlea. Sci Rep 2022;12:19234. [PMID: 36357503 PMCID: PMC9649659 DOI: 10.1038/s41598-022-23653-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 11/03/2022] [Indexed: 11/12/2022]  Open
7
Best Fit 3D Basilar Membrane Reconstruction to Routinely Assess the Scalar Position of the Electrode Array after Cochlear Implantation. J Clin Med 2022;11:jcm11082075. [PMID: 35456169 PMCID: PMC9030636 DOI: 10.3390/jcm11082075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 04/03/2022] [Accepted: 04/05/2022] [Indexed: 12/04/2022]  Open
8
Robotics, automation, active electrode arrays, and new devices for cochlear implantation: A contemporary review. Hear Res 2022;414:108425. [PMID: 34979455 DOI: 10.1016/j.heares.2021.108425] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 12/16/2021] [Accepted: 12/23/2021] [Indexed: 01/14/2023]
9
Torres R, Daoudi H, Lahlou G, Sterkers O, Ferrary E, Mosnier I, Nguyen Y. Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition. Front Surg 2021;8:729736. [PMID: 34568420 PMCID: PMC8461256 DOI: 10.3389/fsurg.2021.729736] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 08/17/2021] [Indexed: 11/13/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA