1
|
Zamparini F, Spinelli A, Gandolfi MG, Prati C. 10 Years of Convergent Neck Implants: A Systematic Review of Clinical Outcomes, Initial Original Concepts, and Changes in Surgical and Prosthetic Protocols. APPLIED SCIENCES 2024; 14:7568. [DOI: 10.3390/app14177568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
The study reviewed the state of the art of the clinical use of a convergent-neck-designed Prama implant. This implant was introduced approximately 10 years ago and was characterized by a specific and unique convergent neck with a microtextured surface (UTM surface) and Zirconium Titanium (ZirTi) implant body surface. The neck design was developed to adopt the biologically oriented preparation technique (BOPT). A critical analysis of the published clinical studies and an evaluation of the adopted clinical protocols were performed. A total of forty-six articles were eligible to be reviewed. Only sixteen clinical studies reported clinical outcomes on Prama implants, and nine of these were selected having the longest follow-up from different research groups. The clinical follow-up/duration of the studies ranged from 12 months to 6 years. The initially proposed protocols explored neck supracrestal–transmucosal placement and gained interest due to its minimally invasive concept and the ability to proceed without a pre-prosthesis second surgery. The following investigations dedicated attention to the subcrestal or equicrestal implant placement with the conventional flap approach. The clinical studies characterized by the transmucosal exposed neck approach reported high survival rates with a stable bone morphology and reduced bone loss during the follow-up. Further recent implementations included the introduction of different convergent neck heights that need to be evaluated. The use of intraoral scanner technologies and digital workflow resulted in a simpler methodology with control of the marginal crown morphology. The studies support the concept that the hard tissue parameters (such as marginal bone level, MBL) and soft tissue parameters (such as pink esthetic score, PES) were stable or improved during the follow-up. Definitive crowns, designed with low invasiveness for soft tissues, were possible thanks to the morphology of the neck. The clinical studies support the use of the Prama implant with the different neck positions, demonstrating hard tissue preservation and optimal esthetic results in the first years following insertion. However, the current body of evidence is not robust enough to draw definitive conclusions, especially in the long term, and further high-quality research (long-term randomized trials) is required to consolidate these early observations.
Collapse
Affiliation(s)
- Fausto Zamparini
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
- Laboratory of Green Biomaterials and Oral Pathology, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
| | - Andrea Spinelli
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
| | - Maria Giovanna Gandolfi
- Laboratory of Green Biomaterials and Oral Pathology, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
| | - Carlo Prati
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
| |
Collapse
|
2
|
Zhang W, Huang S, Ye Q, Wei D, Zhou X. Clinical efficacy of early and delayed loading implants: A systematic review and meta-analysis. J Prosthet Dent 2024; 132:343-353. [PMID: 35963711 DOI: 10.1016/j.prosdent.2022.05.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 05/27/2022] [Accepted: 05/31/2022] [Indexed: 11/20/2022]
Abstract
STATEMENT OF PROBLEM Whether early loaded implants have similar clinical outcomes to delayed loaded implants is unclear. PURPOSE The purpose of this systematic review and meta-analysis was to compare the outcomes of early and delayed loading dental implants. MATERIAL AND METHODS Comprehensive searches of the MEDLINE, EMBASE, and Ovid databases were enriched by hand searches. Only human randomized controlled trials (RCTs) that compared the clinical efficacy of early and delayed loading were included. The survival rates and marginal bone level (MBL) changes were pooled and analyzed by risk ratios (RRs) and weighted mean differences (WMDs), respectively. The subgroup analyses, which were based on the Mantel-Haenszel and inverse-variance methods, included the types of prosthesis, implant time, occlusion, number of missing teeth, operation methods, dental position, healing methods, and type of first restoration. A funnel plot was used for heterogeneity analysis. RESULTS Eighteen trials were included from the initial 601 articles. The dental implant survival rates for the early and delayed loading were similar (P>.05). Regarding the marginal bone level changes, the 2 loading protocols also reached a comparable clinical outcome (P>.05). CONCLUSIONS Early implant loading should achieve the same clinical efficacy as the delayed loading method.
Collapse
Affiliation(s)
- Wenhao Zhang
- Doctor, Department of Stomatology, Shenzhen Baoan Women's and Children's Hospital, Jinan University, Shenzhen, PR China
| | - Sui Huang
- Doctor, Department of Pathology, Shenzhen Baoan Women's and Children's Hospital, Jinan University, Shenzhen, PR China
| | - Qi Ye
- Doctor, Department of Stomatology, Shenzhen Baoan Women's and Children's Hospital, Jinan University, Shenzhen, PR China
| | - Dixin Wei
- Doctor, Department of Stomatology, Shenzhen Baoan Women's and Children's Hospital, Jinan University, Shenzhen, PR China
| | - Xincai Zhou
- Professor, Department of Stomatology, Shenzhen Baoan Women's and Children's Hospital, Jinan University, Shenzhen, PR China.
| |
Collapse
|
3
|
Rastogi S, Rani K, Sharma V, Bharti PS, Deo K, Jain V, Nanda A, Kumar S, Koli DK. Osteogenic markers in peri-implant crevicular fluid in immediate and delayed-loaded dental implants: A randomized controlled trial. Clin Implant Dent Relat Res 2023. [PMID: 36940923 DOI: 10.1111/cid.13199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/23/2023]
Abstract
INTRODUCTION The study evaluates the levels of matrix metalloprotease-8 (MMP-8), and Cathepsin-K (CatK) in peri-implant crevicular fluid (PICF) among patients with immediate loaded (IL) and delayed-loaded (DL) implants at different time points to know the inflammation and osteogenic status. METHODS The study population consisted of two groups (n = 25, each group) with a mean age of 28.7 ± 3.5 years, and PICF was collected. MMP-8 and CatK levels were quantified through ELISA. RESULTS We observed the concentrations of inflammatory markers (MMP-8 and CatK) at three time points in the IL and DL groups. The mean concentration of MMP-8 in the IL group was 9468 ± 1230 pg/mL, 5547 ± 1088 pg/mL, and 7248 ± 1396 pg/mL at 2 weeks, 3 months, and 12 months, respectively; while in the DL group was 10 816 ± 779.7 pg/mL, 9531 ± 1245 pg/mL, and 9132 ± 1265 pg/mL at 2 weeks, 3 and 12 months, respectively. The mean concentration of Cat-K in the IL group was observed at 422.1 ± 36.46 pg/mL, 242.9 ± 25.87 pg/mL, and 469 ± 75.38 pg/mL at 2 weeks, 3, and 12 months, whereas in the DL group was 654.6 ± 152.9 pg/mL, 314.7 ± 28.29 pg/mL, and 539.8 ± 115.1 pg/mL at 2 weeks, 3 months and 12 months, respectively. CONCLUSION In this study, the levels of CatK and MMP-8 levels decline at 12 months in both groups, and the IL group shows lower values compared to the DL group; however, no significant changes were observed after analyses were adjusted for multiple comparisons (p > 0.025). Therefore, there is not much difference observed in the inflammation process between immediate and delayed loading. (Clinical trial identifier: CTRI/2017/09/009668).
Collapse
Affiliation(s)
- Simran Rastogi
- Department of Biophysics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Komal Rani
- Department of Pathology & Laboratory Medicine, All India Institute of Medical Sciences Bibinagar, Hyderabad, Telangana, India
| | - Vaibhav Sharma
- Department of Health, Education and Technology, Lulea University of Technology, Lulea, Sweden
| | - Prahalad Singh Bharti
- Department of Biophysics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Krishna Deo
- Department of Prosthodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Veena Jain
- Department of Prosthodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Aditi Nanda
- Department of Prosthodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Saroj Kumar
- Department of Biophysics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
- Department of Health, Education and Technology, Lulea University of Technology, Lulea, Sweden
| | - Dheeraj Kumar Koli
- Department of Prosthodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| |
Collapse
|
4
|
The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour. MATERIALS 2022; 15:ma15103636. [PMID: 35629663 PMCID: PMC9148149 DOI: 10.3390/ma15103636] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Revised: 05/12/2022] [Accepted: 05/17/2022] [Indexed: 02/04/2023]
Abstract
Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility. For this purpose, 90 dental implants with a neck diameter of 4 mm and a torque of 22 Ncm were placed in 7 fresh cow ribs. The placement was carried out according to the established protocols. The implants had a roughness Ra of 1.92 μm. The arrangement of the particles in the bone tissue was studied by micro-CT, and no particle clusters were observed. The different granulometries of 5, 15, and 30 μm were obtained; the specific surface area was determined by laser diffraction; the topography was determined by scanning electron microcopy; and the particles were chemically analysed by X-ray energy microanalysis. The residual stresses of the particles were obtained by X-ray diffraction using the Bragg-Bentano configuration. The release of titanium ions to the physiological medium was performed using ICP-MS at 1, 3, 7, 14, and 21 days. The cytocompatibility of the particles with HFF-1 fibroblast and SAOS-2 osteoblast cultures was characterized. The results showed that the lowest specific surface area (0.2109 m2/g) corresponds to the particles larger than 30 μm being higher than 0.4969 and 0.4802 m2/g of those that are 5 and 15 μm, respectively, observing in all cases that the particles have irregular morphologies without contamination of the drills used in the surgery. The highest residual stresses were found for the small particles, -395 MPa for the 5 μm particles, and -369 for the 15 μm particles, and the lowest residual stresses were found for the 30 μm particles with values of -267 MPa. In all cases, the residual stresses were compressive. The lowest ion release was for the 30 μm samples, as they have the lowest specific surface area. Cytocompatibility studies showed that the particles are cytocompatible, but it is the smallest ones that are lower and very close to the 70% survival limit in both fibroblasts and osteoblasts.
Collapse
|
5
|
Chen J, Cai M, Yang J, Aldhohrah T, Wang Y. Immediate versus early or conventional loading dental implants with fixed prostheses: A systematic review and meta-analysis of randomized controlled clinical trials. J Prosthet Dent 2019; 122:516-536. [PMID: 31421892 DOI: 10.1016/j.prosdent.2019.05.013] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 05/14/2019] [Accepted: 05/14/2019] [Indexed: 01/23/2023]
Abstract
STATEMENT OF PROBLEM Immediate loading of dental implants has gained widespread popularity because of its advantages in shortening treatment duration and improving esthetics and patient acceptance. However, whether immediate loading can achieve clinical outcomes comparable with those of early or conventional delayed loading is still unclear. PURPOSE The purpose of this systematic review and meta-analysis was to compare the efficacy of immediate loading versus early or conventional loading implants in patients rehabilitated with fixed prostheses. MATERIAL AND METHODS Electronic searches of CENTRAL, EMBASE, and MEDLINE were supplemented by manual searches up to October 2018. Only human randomized controlled trials (RCTs) comparing immediate with early or conventional loading dental implants were included. Quality assessment was performed by using the Cochrane Collaboration tool. For the meta-analysis, the dichotomous and continuous variables were pooled and analyzed by using risk ratios (RRs) and weighted mean differences (WMDs), with 95% confidence intervals (95% CIs). The outcomes assessed included survival rate, marginal bone level changes, peri-implant gingival level, probing depth, and implant stability. The subgroup analyses included healing methods, implant time, occlusal contact, number of missing teeth, and tooth position. RESULTS Thirty-nine trials (49 articles) were included from the initial 763 references evaluated. When compared with conventional loading, with implants regarded as a statistical unit, a statistically significant lower survival rate was observed in the immediate loading dental implant (RR=0.974; 95% CI, 0.954, 0.994; P=.012). Regarding other outcomes, including marginal bone level changes, peri-implant gingival level, probing depth, and implant stability, no statistically significant differences were observed when comparing immediate versus early or conventional loading (P>.05). CONCLUSIONS Compared with early loading, immediate loading could achieve comparable implant survival rates and marginal bone level changes. Compared with conventional loading, immediate loading was associated with a higher incidence of implant failure.
Collapse
Affiliation(s)
- Jie Chen
- Postgraduate student, Department of Prosthodontics, Guanghua School of Stomatology & Hospital of Stomatology, Guangdong Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, PR China
| | - Min Cai
- Predoctoral student, Department of Prosthodontics, Guanghua School of Stomatology & Hospital of Stomatology, Guangdong Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, PR China
| | - Jiajun Yang
- Postgraduate student, Department of Prosthodontics, Guanghua School of Stomatology & Hospital of Stomatology, Guangdong Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, PR China
| | - Taghrid Aldhohrah
- Postgraduate student, Department of Prosthodontics, Guanghua School of Stomatology & Hospital of Stomatology, Guangdong Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, PR China
| | - Yan Wang
- Professor, Department of Prosthodontics, Guanghua School of Stomatology & Hospital of Stomatology, Guangdong Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, PR China.
| |
Collapse
|
6
|
Comparative Study Between an Immediate Loading Protocol Using the Digital Workflow and a Conventional Protocol for Dental Implant Treatment: A Randomized Clinical Trial. J Clin Med 2019; 8:jcm8050622. [PMID: 31067835 PMCID: PMC6572205 DOI: 10.3390/jcm8050622] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 05/01/2019] [Accepted: 05/03/2019] [Indexed: 11/16/2022] Open
Abstract
Background: The purposes of this randomized clinical trial study was to compare the immediate loading of dental implants while employing digital workflow and conventional implants in terms of the success rate, marginal bone level, and patient satisfaction. Methods: Fifty patients who had edentulous area on the mandibular premolar or molar area were included in the study. Twenty-five patients were assigned to immediate loading implant treatment using the digital technique and 25 patients were assigned to conventional loading implant treatment. In the first group, the patients were received digital impression (Cerec Omnicam, Dentsply Sirona®, York, PA, USA), designed, producing zirconia crown, and inserted on the same surgery day. The second group, after a healing period of three months, was received analog impression following conventional impression for the zirconia crown. Clinical outcome and radiographic bone level were evaluated after three, six, and 12 months. Patient satisfaction was measured at 12 months after inserting the implant. Results: There was no implants and protheses failure in both groups. The mean resonance frequency analysis values at the day of surgery were 78.26 ± 4.09 in immediate loading using the digital group (ILD) and 73.74 ± 5.14 in the conventional loading group (CL), respectively. Insertion torque values at the day of surgery were 36.60 ± 12.64 in ILD and 38.8 ± 12.19 CL, respectively. The marginal bone level in CL at three, six, and 12 months were 0.14 ± 0.28 mm, 0.18 ± 0.30 mm, and 0.17 ± 0.29 mm, respectively, while in ILD at three, six, and 12 months were 0.18 ± 0.33 mm and 0.16 ± 0.27 mm and 0.15 ± 0.31, respectively. There was no statistically significant difference between the two groups. Only one question in patient satisfaction's questionnaire was "Now, can your dental implant and crown be used well?" had been significantly different in favor to the conventional group. Conclusion: Within the limitation of this study, it may be concluded that, after one-year follow up, there were no statistically significant differences between the immediate loading of dental implants employed from the digital workflow and conventional implant treatment technique in the success rate and marginal bone level. In patient satisfaction, there was only statistic significant difference in question related to implant prosthetic function in favor of the CL group, whereas the question concerning speaking, cleansing, price, and expectation displayed no difference.
Collapse
|