• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4619871)   Today's Articles (5)   Subscriber (49404)
For: Bardy GH. Ensuring automatic detection of ventricular fibrillation. Circulation 1992;86:1634-5. [PMID: 1423974 DOI: 10.1161/01.cir.86.5.1634] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Number Cited by Other Article(s)
1
Sauer WH, Callans DJ. The Implantable Cardioverter-Defibrillator. CARDIOVASCULAR MEDICINE 2007. [DOI: 10.1007/978-1-84628-715-2_104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]  Open
2
Cooklin M, Tummala RV, Peters RW, Shorofsky SR, Gold MR. Comparison of bipolar and integrated sensing for redetection of ventricular fibrillation. Am Heart J 1999;138:133-6. [PMID: 10385776 DOI: 10.1016/s0002-8703(99)70258-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
3
Gold MR, Olsovsky MR, Pelini MA, Peters RW, Shorofsky SR. Comparison of single- and dual-coil active pectoral defibrillation lead systems. J Am Coll Cardiol 1998;31:1391-4. [PMID: 9581739 DOI: 10.1016/s0735-1097(98)00103-x] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
4
Khalighi K, Florin TJ, Peters RW, Shorofsky SR, Gold MR. Distortion of intracardiac electrograms following defibrillator shocks for atrial tachyarrhythmias. Pacing Clin Electrophysiol 1997;20:1682-5. [PMID: 9227767 DOI: 10.1111/j.1540-8159.1997.tb03539.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
5
Hurst TM, Krieglstein H, Tillmanns H, Waldecker B. Inappropriate management of self-terminating ventricular arrhythmias by implantable cardioverter defibrillators despite a specific reconfirmation algorithm: a report of two cases. Pacing Clin Electrophysiol 1997;20:1328-31. [PMID: 9170134 DOI: 10.1111/j.1540-8159.1997.tb06787.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
6
The Amplifier: Sensing the Depolarization. ACTA ACUST UNITED AC 1996. [DOI: 10.1007/978-1-4615-6345-7_14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
7
Jung W, Manz M, Moosdorf R, Tebbenjohanns J, Pfeiffer D, Lüderitz B. Changes in the amplitude of endocardial electrograms following defibrillator discharge: comparison of two lead systems. Pacing Clin Electrophysiol 1995;18:2163-72. [PMID: 8771129 DOI: 10.1111/j.1540-8159.1995.tb04643.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
8
Friedman PA, Stanton MS. The pacer-cardioverter-defibrillator: function and clinical experience. J Cardiovasc Electrophysiol 1995;6:48-68. [PMID: 7743010 DOI: 10.1111/j.1540-8167.1995.tb00757.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA