Cheng H, Bangash AB, Tao Y, Jiang R, Liu Q, Cheng C, Fu G, Jiang C. Intracardiac echocardiography guided electrified J-wire trans-septal puncture: A prospective randomized controlled trial. Pacing Clin Electrophysiol 2024; 47:448-454. [PMID: 38291877 DOI: 10.1111/pace.14916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 12/08/2023] [Accepted: 12/21/2023] [Indexed: 02/01/2024]
Abstract
BACKGROUND Application of electrocautery to a J-wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique. METHODS Two hundred consecutive patients were randomized in a 1:1 fashion to either the ICE-guided electrified J-wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, "coag" mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time. RESULTS All patients complete the procedure safely. The electrified J-wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra-atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J-wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra-atrial shunt (4.3% vs. 6%, p = .654) during the 3-month's follow up. CONCLUSION Using an electrified J-wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non-fluoroscopy AF ablation.
Collapse
Affiliation(s)
- Hui Cheng
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| | - Abdul Basit Bangash
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| | - Yuhang Tao
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| | - Ruhong Jiang
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| | - Qiang Liu
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| | - Cheng Cheng
- Department of Cardiology, The Second Hospital of Anhui Medical University, HeFei, Anhui, P. R. China
| | - Guosheng Fu
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| | - Chenyang Jiang
- Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Hangzhou, Zhejiang, P. R. China
| |
Collapse
|
2
|
Knight BP, Wasserlauf J, Al-Dujaili S, Al-Ahmad A. Comparison of transseptal puncture using a dedicated RF wire versus a mechanical needle with and without electrification in an animal model. J Cardiovasc Electrophysiol 2024; 35:16-24. [PMID: 37890041 DOI: 10.1111/jce.16111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 10/10/2023] [Indexed: 10/29/2023]
Abstract
INTRODUCTION Mechanical force to achieve transseptal puncture (TSP) using a standard needle may lead to overshooting and injury, and can potentially be avoided using a radiofrequency (RF)-powered needle or wire. Applying electrocautery to needles and guidewires as an alternative to purpose-built RF systems has been associated with safety risks, such as tissue coring and thermal damage. The commercially available AcQCross needle-dilator system (Medtronic) features a sharp open-ended needle for mechanical puncture, as well as a built-in connector to enable energy delivery for RF puncture. This investigation compares the safety and efficacy of the AcQCross needle to the dedicated VersaCross RF wire system and generator (Baylis Medical/Boston Scientific). METHODS In an ex vivo porcine model, VersaCross wire punctures were performed using 1 s, constant mode (approx. 10 W) with maximum two attempts. AcQCross punctures were performed by applying energy for 2 s using a standard electrosurgical generator at 10 W (max. five attempts), 20 W (max. two attempts), and 30 W (max. two attempts). Efficacy was assessed in terms of puncture success and a number of energy applications required for TSP. Safety was assessed quantitatively as force required for TSP, energy required to puncture, and incidence of tissue coring, as well as by qualitative assessment of puncture sites. Additional qualitative observation of tissue cores and debris were obtained from TSP performed in live swine. RESULTS RF TSP was 100% successful using the VersaCross wire with 1.0 ± 0.0 attempts. When power was used with the AcQCross needle, it failed to puncture at low (10 and 20 W) power settings; TSP was achieved with 30 W of energy with 91% success using 1.53 ± 0.51 attempts (p < .05 vs. VC) with greater variability (F1,33 = 9223.5, p < .0001). Compared to RF puncture using the VersaCross system, mechanical puncture, alone, using the AcQcross needle required six times more force (8 mm additional forward device displacement) to perforate the septum. Qualitative assessment of puncture sites revealed larger defects and more tissue charring with the AcQCross needle at 30 W compared to punctures with VersaCross wire. Tissue coring with the open-ended AcQCross needle was observed in vivo and measured to occur in 57% of punctures using the ex vivo model; no coring was observed with the closed-tip VersaCross wire. CONCLUSIONS The AcQCross needle frequently required higher energy of 30 W to achieve RF TSP and was associated with tissue coring and charring, which have been, previously, reported when electrifying a standard open-ended mechanical needle or guidewire. These findings may limit safety and effectiveness compared to the VersaCross system.
Collapse
Affiliation(s)
- Bradley P Knight
- Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Jeremiah Wasserlauf
- Cardiovascular Institute, North Shore University Health System, Evanston, Illinois, USA
| | - Saja Al-Dujaili
- Department of Scientific Affairs, Boston Scientific Corporation, Mississauga, Ontario, Canada
| | - Amin Al-Ahmad
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas, USA
| |
Collapse
|
3
|
Khan A, Qureshi AM, Bansal M, Stapleton G, Webb MK, Lam W, Eilers L, Singh HR, Gowda ST. Extra-cardiac and complex Fontan baffle fenestration using radio frequency current via surgical electrocautery. Cardiol Young 2023; 33:2621-2627. [PMID: 37092668 DOI: 10.1017/s1047951123000380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
BACKGROUND Fontan baffle punctures and creation of Fontan fenestration for cardiac catheterisation procedures remain challenging especially due to the heavy calcification of prosthetic material and complex anatomy. OBJECTIVES We sought to evaluate our experience using radiofrequency current via surgical electrocautery needle for Fontan baffle puncture to facilitate diagnostic, electrophysiology, and interventional procedures. METHODS A retrospective chart review of all Fontan patients (pts) who underwent Fontan baffle puncture using radiofrequency energy via surgical electrocautery from three centres were performed from January 2011 to July 2021. RESULTS A total of 19 pts underwent 22 successful Fontan baffle puncture. The median age and weight were 17 (3-36 years) and 55 (14-88) kg, respectively. The procedural indications for Fontan fenestration creation included: diagnostic study (n = 1), atrial septostomy and stenting (n = 1), electrophysiology study and ablation procedures (n = 8), Fontan baffle stenting for Fontan failure including protein-losing enteropathy (n = 7), and occlusion of veno-venous collaterals (n = 2) for cyanosis. The type of Fontan baffles included: extra-cardiac conduits (n = 12), lateral tunnel (n = 5), classic atrio-pulmonary connection (n = 1), and intra-cardiac baffle (n = 1). A Fontan baffle puncture was initially attempted using traditional method in 6 pts and Baylis radiofrequency trans-septal system in 2 pts unsuccessfully. In all pts, Fontan baffle puncture using radiofrequency energy via electrocautery needle was successful. The radiofrequency energy utilised was (10-50 W) and required 1-5 attempts for 2-5 seconds. There were no vascular or neurological complications. CONCLUSIONS Radiofrequency current delivery using surgical electrocautery facilitates Fontan baffle puncture in patients with complex and calcified Fontan baffles for diagnostic, interventional, and electrophysiology procedures.
Collapse
Affiliation(s)
- Asra Khan
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Athar M Qureshi
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Manish Bansal
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Gary Stapleton
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Melissa K Webb
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Wilson Lam
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Lindsay Eilers
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| | - Harinder R Singh
- The Children's Hospital of San Antonio, 333 N. Santa Rosa Street, San Antonio, TX 78207, USA
| | - Srinath T Gowda
- Pediatric Interventional Cardiology, Baylor College of Medicine, Texas Children's Hospital, 6651 Main Street, Suite E1920, Houston, TX 77030, USA
| |
Collapse
|
4
|
Use of a novel integrated dilator-needle system in cryoballoon procedures: a zero-exchange approach. J Interv Card Electrophysiol 2022; 65:527-534. [PMID: 35799029 DOI: 10.1007/s10840-022-01294-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 06/29/2022] [Indexed: 10/17/2022]
Abstract
BACKGROUND Recently, a novel integrated dilator-needle system (AcQCross Qx, Acutus Medical) was introduced to reduce the number of exchanges for a transseptal access. This system can be used in combination with large bore sheaths. In this pilot study, we evaluated the safety and efficacy of a zero-exchange approach with the AcQCross system in cryoballoon procedures. METHODS In this retrospective single-center study, we included 40 patients (AcQCross: n = 20; control group: n = 20) who underwent a cryoballoon procedure for the treatment of atrial fibrillation. In the AcQCross and control group, patients underwent ablation with POLARx (Boston Scientific) and Arctic Front Advance Pro (AFA-Pro, Medtronic) in equal numbers (n = 10). In the AcQCross group, the AcQGuide Max sheath (Acutus Medical) was used in all POLARx cases. RESULTS The baseline characteristics of the study population were comparable between groups. In the AcQCross group, there was a reduction in procedure time (49.7 ± 9.0 min vs. 59.6 ± 8.1 min, P < 0.001) and time from puncture until balloon delivery (15.5 ± 6.8 min vs. 21.5 ± 7.4 min, P = 0.01) in comparison with the control group. The balloon in body time, fluoroscopy time, number of cryoapplications, and biophysical parameters were similar between groups. There was one temporary phrenic nerve injury in the AcQCross group. Importantly, no signs of air embolism were noted with the AcQGuide Max sheath. CONCLUSIONS The use of the novel AcQCross system improves procedural efficacy in cryoballoon procedures by reducing the number of exchanges.
Collapse
|
5
|
Kaplan RM, Wasserlauf J, Knight BP. Transseptal Access: A Review of Contemporary Tools. J Cardiovasc Electrophysiol 2022; 33:1927-1931. [PMID: 35229417 PMCID: PMC9545840 DOI: 10.1111/jce.15428] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/11/2022] [Accepted: 02/14/2022] [Indexed: 11/28/2022]
Abstract
Transseptal left atrial catheterization is routinely used for many common catheter‐based interventions. Tools for transseptal catheterization have advanced over the recent years. Such tools include imaging advances with intracardiac echocardiology as well as an array of needles, wires, and dilators to achieve transseptal access with greater ease and safety. This study will discuss the contemporary tools for transseptal catheterization and guidance for difficult cases.
Collapse
Affiliation(s)
- Rachel M Kaplan
- Section of Electrophysiology, Division of Cardiology, Northwestern University, Feinberg School of Medicine
| | | | - Bradley P Knight
- Section of Electrophysiology, Division of Cardiology, Northwestern University, Feinberg School of Medicine
| |
Collapse
|
6
|
Wasserlauf J, Knight BP. Comparing the safety and effectiveness of dedicated radiofrequency transseptal wires to electrified metal guidewires. J Cardiovasc Electrophysiol 2022; 33:371-379. [PMID: 34978365 PMCID: PMC9303383 DOI: 10.1111/jce.15341] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 11/10/2021] [Accepted: 12/06/2021] [Indexed: 12/04/2022]
Abstract
Background Application of electrocautery to a metal guidewire is used by some operators to perform transseptal puncture (TSP). Commercially available dedicated radiofrequency (RF) guidewires may represent a better alternative. This study compares the safety and effectiveness of electrified guidewires to a dedicated RF wire. Methods TSP was performed on freshly excised porcine hearts using an electrified 0.014″ or 0.032″ guidewire under various power settings and was compared to TSP using a dedicated RF wire with 5 W power (0.035″ VersaCross RF System, Baylis Medical). The primary endpoint was the number of attempts required to achieve TSP. Secondary endpoints included the rate of TSP failure, TSP consistency, the effect of the distance between the tip of the guidewire and the tip of the dilator, and effect of RF power output level. Qualitative secondary endpoints included tissue puncture defect appearance, thermal damage to the TSP guidewire or dilator, and tissue temperature using thermal imaging. Results The RF wire required on average 1.10 ± 0.47 attempts to cross the septum. The 0.014″ electrified guidewire required an overall mean of 2.17 ± 2.36 attempts (2.0 times as many as the RF wire; p < .01), and the 0.032″ electrified guidewire required an overall mean of 3.90 ± 2.93 attempts (3.5 times as many as the RF wire; p < .01). Electrified guidewires had a higher rate of TSP failure, and caused larger defects and more tissue charring than the RF wire. Thermal analysis showed higher temperatures and a larger area of tissue heating with electrified guidewires than the RF wire. Conclusion Fewer RF applications were required to achieve TSP using a dedicated RF wire compared to an electrified guidewire. Smaller defects and lower tissue temperatures were also observed using the RF wire. Electrified guidewires required greater energy delivery and were associated with equipment damage and tissue charring, which may present a risk of thrombus, thermal injury, or scarring.
Collapse
Affiliation(s)
- Jeremiah Wasserlauf
- Department of Internal Medicine, Division of Cardiology, Rush University Medical Center, Chicago, Illinois, USA
| | - Bradley P Knight
- Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
7
|
Müller MJ, Backhoff D, Schneider HE, Dieks JK, Rieger J, Krause U, Paul T. Safety of Transseptal Puncture for Access to the Left Atrium in Infants and Children. Pediatr Cardiol 2021; 42:685-691. [PMID: 33454819 PMCID: PMC7990813 DOI: 10.1007/s00246-020-02530-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 12/18/2020] [Indexed: 11/26/2022]
Abstract
Transseptal puncture (TSP) is a standard procedure to obtain access to the left heart. However, data on TSP in infants and children particularly with congenital heart defects (CHD) is sparse. Safety and efficacy of TSP in infants and children < 18 years with normal cardiac anatomy and with CHD were assessed. 327 TSP were performed in a total of 300 individuals < 18 years from 10/2002 to 09/2018 in our tertiary pediatric referral center. Median age at TSP was 11.9 years (IQR 7.8-15; range: first day of life to 17.9 years). 13 subjects were < 1 year. Median body weight was 43.8 kg (IQR 26.9-60; range: 1.8-121 kg). CHD was present in 28/327 (8.6%) procedures. TSP could be successfully performed in 323/327 (98.8%) procedures and was abandoned in 4 procedures due to imminent or incurred complications. Major complications occurred in 4 patients. 3 of these 4 subjects were ≤ 1 year of age and required TSP for enlargement of a restrictive atrial septal defect in complex CHD. Two of these babies deceased within 48 h after TSP attempt. The third baby needed urgent surgery in the cath lab. Pericardial effusion requiring drainage was noted in the forth patient (> 1 year) who was discharged well later. Minor complications emerged in 5 patients. The youngest of these individuals (0.3 years, 5.8 kg) developed small pericardial effusion after anterograde ballon valvuloplasty for critical aortic stenosis. The remaining 4/5 patients developed small pericardial effusion after ablation of a left-sided accessory atrioventricular pathway (6.1-12.2 years, 15.6-34.0 kg). TSP for access to the left heart was safe and effective in children and adolescents > 1 year of age. However, TSP was a high-risk procedure in small infants with a restrictive interatrial septum with need for enlargement of interatrial communication.
Collapse
Affiliation(s)
- Matthias J Müller
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
| | - David Backhoff
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Heike E Schneider
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Jana K Dieks
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Julia Rieger
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Ulrich Krause
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| | - Thomas Paul
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Robert-Koch-Str. 40, 37075, Göttingen, Germany
| |
Collapse
|
8
|
Trans-Septal Puncture Through Gore® Cardioform Septal Occluder Device - Step by Step Approach. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 23:91-93. [PMID: 32680698 DOI: 10.1016/j.carrev.2020.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 05/18/2020] [Accepted: 07/01/2020] [Indexed: 11/21/2022]
Abstract
We describe the patient selection, intraprocedural imaging, and procedural technique for transseptal puncture through the Gore® Cardioform interatrial septal occluder. Due to new indications for PFO closure and increasing need for access to the left atrium via percutaneous approach, we expect an increasing need for utilization of a trans-septal puncture technique through these devices.
Collapse
|
9
|
Sanchez JM, Shah R, Kouassi Y, Chronowic M, Wilson L, Marcus GM. A cost‐effectiveness analysis comparing a conventional mechanical needle to a radiofrequency device for transseptal punctures. J Cardiovasc Electrophysiol 2020; 31:1672-1677. [DOI: 10.1111/jce.14500] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 04/10/2020] [Accepted: 04/14/2020] [Indexed: 11/27/2022]
Affiliation(s)
- José M. Sanchez
- Section of Cardiac Electrophysiology, Division of Cardiology University of California San Francisco California
| | - Rahil Shah
- Department of Clinical Pharmacy University of California San Francisco California
| | - Yao Kouassi
- Department of Clinical Pharmacy University of California San Francisco California
| | | | - Leslie Wilson
- Department of Clinical Pharmacy University of California San Francisco California
| | - Gregory M. Marcus
- Section of Cardiac Electrophysiology, Division of Cardiology University of California San Francisco California
| |
Collapse
|
10
|
Use of a radiofrequency guidewire to simplify workflow for left atrium access: a case series. J Interv Card Electrophysiol 2019; 59:551-556. [PMID: 31873840 DOI: 10.1007/s10840-019-00615-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Accepted: 08/25/2019] [Indexed: 10/25/2022]
Abstract
PURPOSE Transseptal puncture (TSP) is widely used in catheter-based cardiac procedures to gain left atrial access, but its workflow has remained largely unchanged in the last 50 years. This study evaluated the safety and efficacy of a novel, simplified technique for TSP with a radiofrequency (RF)-powered guidewire that eliminates multiple exchanges required with standard needles. METHODS TSP was performed in 84 patients undergoing left-sided procedures (72 atrial fibrillation ablations [32 RF, 40 cryoballoon], 4 atrial tachycardia ablations, 2 ventricular arrhythmia ablations, 6 left atrial appendage closure) utilizing a stiff, exchange length RF guidewire. Under fluoroscopic and echocardiographic guidance, the RF guidewire was used to facilitate septal puncture with RF energy and provide a rail for advancing catheters to the left atrium without exchange. All procedures were performed under general anesthesia or sedation. RESULTS TSP was achieved in all patients with no complications. The RF guidewire allowed catheters to be tracked back up to the superior vena cava without exchange in cases where another dropdown was desired to locate a preferred puncture site. The stiffness of the wire provided adequate support to advance all sheaths to the left side regardless of outer diameter. CONCLUSION TSP was performed safely and successfully for various left heart procedures with a RF guidewire that served as an RF transseptal device and a stiff guidewire. This allowed for a more efficient and potentially safer technique without the need for re-wiring or an over the wire sheath exchange. This provides substantial savings in both time and materials.
Collapse
|
11
|
Chow AWC, Cobb V, Sepahpour A, McCready JW. Transseptal puncture performed with the new needle-free 'SafeSept' guidewire: a multicentre experience. J Interv Card Electrophysiol 2019; 59:29-34. [PMID: 31655956 DOI: 10.1007/s10840-019-00608-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Accepted: 08/06/2019] [Indexed: 11/26/2022]
Abstract
PURPOSE Increasing numbers of transseptal punctures (TSP) are performed for different cardiac interventions, especially for left atrial (LA) ablation of atrial fibrillation (AF). Significant TSP-related complications may occur even by experienced operators. Any strategies to mitigate these should be adopted. Previous reports have confirmed the safety and efficacy of the first generation nitinol guidewire for TSP. The objective was to assess the safety and efficacy of a new nitinol 'needle free' SafeSept guidewire (NFSG) for TSP. The distal J-shaped tip (0.014 in.) of the NFSG is unchanged in design; however, the shaft is thicker (0.0315 in.) and stiffer. METHODS This is a multicentre study evaluating TSP without a transseptal needle, using the NFSG via a standard transseptal sheath-dilator, in patients with an indication for TSP. RESULTS A total of 145 consecutive unselected patients were studied. The mean patient age was 59 ± 15. Thirty-one (21.4%) were female and 43 (29.7%) had a previous procedure requiring TSP. The mean transverse LA diameter was 4.0 ± 0.8 cm. AF or LA tachycardia comprised the major indication for TSP (n = 115). Transesophageal echocardiography for direct guidance of TSP was utilised in cases performed under general anesthesia (n = 66, 45.5%). LA access by TSP using the NFSG was achieved successfully in 100% of cases after 1.6 ± 2.3 passes. There were no TSP or other major procedural complications. CONCLUSIONS Use of the NFSG appears to be a safe and effective method in performing TSP. The major improvement in the design of the NFSG is that TSP can be performed without a transseptal needle and exchange for a standard guidewire is not required upon establishing LA access.
Collapse
Affiliation(s)
- Anthony W C Chow
- Barts Heart Centre, Barts Health NHS Trust, St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK.
- The Heart Hospital, University College London Hospital NHS Trust, London, UK.
- The Wellington Hospital, Wellington Place, London, UK.
- Royal Berkshire Hospital, Reading, UK.
| | - Vanessa Cobb
- Barts Heart Centre, Barts Health NHS Trust, St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK
- The Heart Hospital, University College London Hospital NHS Trust, London, UK
| | - Ali Sepahpour
- The Heart Hospital, University College London Hospital NHS Trust, London, UK
| | | |
Collapse
|
12
|
Manolis AS. Transseptal Access to the Left Atrium: Tips and Tricks to Keep it Safe Derived from Single Operator Experience and Review of the Literature. Curr Cardiol Rev 2018; 13:305-318. [PMID: 28969539 PMCID: PMC5730964 DOI: 10.2174/1573403x13666170927122036] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2017] [Revised: 09/13/2017] [Accepted: 09/20/2017] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND Transseptal puncture (TSP) remains a demanding procedural step in accessing the left atrium with inherent risks and safety concerns, mostly related to cardiac tamponade. OBJECTIVE Based on our own experience with 249 TSP procedures and in-depth literature review, we present our results and offer several tips and tricks that may render TSP successful and safe. METHODS This prospective study comprised 249 consecutive patients (146 men), aged 41.6±17.4 years, undergoing TSP by a single operator for ablation of a variety of arrhythmias, mostly related to left accessory pathways (n=145) or left atrial tachycardias (n=33) and more recently, atrial fibrillation (n=70). TSP was guided by fluoroscopy alone in all patients without the use of echocardiography imaging. In addition, an extensive literature review of TSP-related topics was carried out in PubMed, Scopus and Google Scholar. RESULTS Among 249 patients, 33 patients were children or young adolescents (aged 7-18 years); 14 patients were undergoing a repeat procedure. Patients with a manifest accessory pathway were the youngest (mean age 33.7±15.9) and patients with atrial fibrillation the oldest (mean age 56.0±10.8 years). A successful TSP was accomplished in 247 patients (99.2%). Two (0.8%) procedures were complicated by cardiac tamponade managed successfully with pericardiocentesis or surgical drainage. Review of the literature revealed no systematic reviews and meta-analyses of TSP studies; however, several patient series have documented that fluoroscopy-guided TSP, with various modifications in the technique employed in the present series, have been effective in 95-100% of the cases with a complication rate ranging from 0.0% to 6.7%, albeit with a mortality rate of 0.018%- 0.2%. Echo imaging techniques were employed in cases with difficult TSP. CONCLUSION Employing a standardized protocol with use of fluoroscopy alone minimized serious complications to 0.8% (2 patients) among 249 consecutive patients undergoing TSP for ablation of a variety of cardiac arrhythmias. Based on this single-operator experience and review of the literature, a list of practical tips and tricks is provided for a successful and safe procedure, reserving the more expensive and patient inconveniencing echo-imaging techniques for difficult or failed cases.
Collapse
Affiliation(s)
- Antonis S Manolis
- Third Department of Cardiology, Vas. Sofias 114, Athens 115 27. Greece
| |
Collapse
|
13
|
Khan JM, Rogers T, Eng MH, Lederman RJ, Greenbaum AB. Guidewire electrosurgery-assisted trans-septal puncture. Catheter Cardiovasc Interv 2017; 91:1164-1170. [PMID: 28940991 DOI: 10.1002/ccd.27311] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 08/03/2017] [Accepted: 08/07/2017] [Indexed: 11/06/2022]
Abstract
OBJECTIVES Electrifying a coronary guidewire may be a simple escalation strategy when trans-septal needle puncture is unsuccessful. BACKGROUND Radiofrequency energy to facilitate trans-septal puncture through a dedicated device is costly and directly through a trans-septal needle may be less safe. Our technique overcomes these limitations. METHODS The technique was used in patients when trans-septal needle penetration failed despite excessive force or tenting of the atrial septum. A coronary guidewire, connected to an electrosurgery pencil, was advanced through the trans-septal needle, dilator, and sheath to perforate the interatrial septum during a short burst of radiofrequency energy. With the guidewire tip no longer "active," the dilator and sheath were advanced safely over the wire into the left atrium. In posthoc validation, radiofrequency assisted Brockenbrough needle and coronary guidewire punctures were made in freshly explanted pig hearts and compared under microscopy. RESULTS Eight patients who required trans-septal access for structural intervention were escalated to a guidewire electrosurgery strategy. Six patients had thickened fibrotic septum and two had prior surgical patch repair. Crossing was successful in all patients with no procedure related complications. The size of punctures (1.11 ± 0.40 mm vs 0.37 ± 0.08 mm, P = .009) and blanched penumbra (3.62 ± 1.23 mm vs 0.72 ± 0.29 mm, P = .003) in pig atrial septum were larger with an electrified needle than electrified guidewire. The hole generated by the electrified guidewire was smaller than by the nonelectrified needle. CONCLUSIONS When conventional trans-septal puncture fails, a coronary guidewire can be used to deliver brief radiofrequency energy safely and effectively. This technique is inexpensive and accessible to operators.
Collapse
Affiliation(s)
- Jaffar M Khan
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Toby Rogers
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Marvin H Eng
- Division of Cardiology, Henry Ford Health System, Center for Structural Heart Disease, Detroit, Michigan
| | - Robert J Lederman
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Adam B Greenbaum
- Division of Cardiology, Henry Ford Health System, Center for Structural Heart Disease, Detroit, Michigan
| |
Collapse
|
14
|
Gowda ST, Qureshi AM, Turner D, Madan N, Weigand J, Lorber R, Singh HR. Transseptal puncture using surgical electrocautery in children and adults with and without complex congenital heart disease. Catheter Cardiovasc Interv 2017; 90:E46-E54. [PMID: 28766834 DOI: 10.1002/ccd.27202] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Accepted: 06/15/2017] [Indexed: 11/09/2022]
Abstract
BACKGROUND Atrial transseptal puncture (TSP) for cardiac catheterization procedures remain challenging in children and adults with complex congenital heart disease (CHD). OBJECTIVES We sought to evaluate our experience using radiofrequency (RF) current via surgical electrocautery needle for TSP to facilitate diagnostic and interventional procedures. METHODS Retrospective chart review of all patients (pts) who underwent TSP using RF energy (10-25 W) via surgical electrocautery from three centers from January 2011 to January 2017 were evaluated. Echocardiograms were reviewed to define the atrial septum as normal and complex (thin aneurysmal, thick/fibrotic, synthetic patch material, and extra cardiac conduit). RESULTS A total of 54 pts underwent 55 successful TSP. Median age was 12.5 years (1 day-54 years) and weight was 52.7 kg (2-162). Indications for TSP included; EP study and ablation procedures in structurally normal hearts (n = 24) and in complex atrial septum/CHD and structural heart disease pts (n = 30): Electrophysiology study and ablation in 4, diagnostic catheterization in 9, and interventional procedures in 17 pts were performed. Atrial TSP was successful in 54/55 (98%). Atrial perforation with tiny-small pericardial effusion not requiring intervention was noted in 2 pts. TSP was unsuccessful in one critically ill neonate with unobstructed TAPVR and restricted atrial septum who experienced cardiac arrest requiring CPR, ECMO, and emergent surgery. CONCLUSIONS RF current delivery using surgical electrocautery for TSP is a feasible and an effective option in patients with complex CHD for diagnostic, interventional, and electrophysiology procedures.
Collapse
Affiliation(s)
- Srinath T Gowda
- Pediatric Cardiology, The Children's Hospital of San Antonio, Baylor College of Medicine, San Antonio, Texas.,Pediatric Cardiology, Children's Hospital of Michigan, Detroit Medical Center, Detroit, Michigan
| | - Athar M Qureshi
- Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas
| | - Daniel Turner
- Pediatric Cardiology, Children's Hospital of Michigan, Detroit Medical Center, Detroit, Michigan
| | - Nitin Madan
- Pediatric Cardiology, The Children's Hospital of San Antonio, Baylor College of Medicine, San Antonio, Texas
| | - Justin Weigand
- Pediatric Cardiology, The Children's Hospital of San Antonio, Baylor College of Medicine, San Antonio, Texas
| | - Richard Lorber
- Pediatric Cardiology, The Children's Hospital of San Antonio, Baylor College of Medicine, San Antonio, Texas
| | - Harinder R Singh
- Pediatric Cardiology, The Children's Hospital of San Antonio, Baylor College of Medicine, San Antonio, Texas.,Pediatric Cardiology, Children's Hospital of Michigan, Detroit Medical Center, Detroit, Michigan
| |
Collapse
|
15
|
O'Brien B, Zafar H, De Freitas S, Sharif F. Transseptal puncture - Review of anatomy, techniques, complications and challenges. Int J Cardiol 2017; 233:12-22. [PMID: 28202256 DOI: 10.1016/j.ijcard.2017.02.009] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Revised: 12/22/2016] [Accepted: 02/01/2017] [Indexed: 12/17/2022]
Abstract
In recent years, the transseptal puncture approach has enabled passage of increasingly large and complex devices into the left atrium. Traditional tools remain effective in creating and dilating the initial puncture, with an acceptable safety profile. Even for skilled operators, the procedure is technically demanding and requires sound understanding of atrial anatomy. Intracardiac echocardiography is useful in cases of previous septal repair, poorly defined fossa ovalis anatomy or when considering patent foramen ovale portal crossing. Iatrogenic atrial septal defect (iASD) is the most commonly encountered long-term complication and there is increasing evidence that larger devices are leading to symptomatic defects. The size of the sheath crossing the septum is the strongest predictor of iASD formation but other factors such as longer procedure times, significant catheter manipulation and high pulmonary pressures also contribute. Transcatheter mitral valve repair involves the use of large 22 Fr catheters which carry alarmingly high rates of defect persistence with precipitation of symptoms and possible influence on mortality. Long-term follow up data, particularly beyond the 12-month period are lacking and resultantly, evidence to guide management is sparse. Refinements of conventional instruments, as well as innovations to puncture the septum without mechanical pressure, herald a progressively safer future for the transseptal technique.
Collapse
Affiliation(s)
- Barry O'Brien
- Biomedical Engineering, School of Engineering & Informatics, National University of Ireland (NUI), Galway, Ireland
| | - Haroon Zafar
- Cardiovascular Research Centre Galway, School of Medicine, NUI, Galway, Ireland; School of Medicine, NUI, Galway, Ireland.
| | - Simon De Freitas
- Cardiovascular Research Centre Galway, School of Medicine, NUI, Galway, Ireland; School of Medicine, NUI, Galway, Ireland
| | - Faisal Sharif
- Cardiovascular Research Centre Galway, School of Medicine, NUI, Galway, Ireland; School of Medicine, NUI, Galway, Ireland; Department of Cardiology, University Hospital Galway, Ireland; BioInnovate, Ireland; CÚRAM, SFI Centre for Research in Medical Devices, Galway, Ireland
| |
Collapse
|
16
|
Modified Transseptal Puncture Technique in Challenging Septa: A Randomized Comparison to Conventional Technique. BIOMED RESEARCH INTERNATIONAL 2017; 2017:2351925. [PMID: 28251152 PMCID: PMC5303838 DOI: 10.1155/2017/2351925] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 11/27/2016] [Accepted: 12/20/2016] [Indexed: 11/29/2022]
Abstract
Background. Transseptal puncture (TSP) can be challenging. We compared safety and efficacy of a modified TSP technique (“mosquito” technique, MOSQ-TSP) to conventional TSP (CONV-TSP). Method. Patients undergoing AF ablation in whom first attempt of TSP did not result in left atrial (LA) pressure (failure to cross, FTC) were randomized to MOSQ-TSP (i.e., puncture of the fossa via a wafer-thin inner stylet) or CONV-TSP (i.e., additional punctures at different positions). Primary endpoint was LA access. Secondary endpoints were safety, time, fluoroscopic dose (dose-area product, DAP), and number of additional punctures from FTC to final LA access. Result. Of 384 patients, 68 had FTC (MOSQ-TSP, n = 34 versus CONV-TSP, n = 34). No complications were reported. In MOSQ-TSP, primary endpoint was 100% (versus 73.5%, p < 0.002), median time to LA access was 72 s [from 37 to 384 s] (versus 326 s [from 75 s to 1936 s], p < 0.002), mean DAP to LA access was 1778 ± 2315 mGy/cm2 (versus 9347 ± 10690 mGy/cm2, p < 0.002), and median number of additional punctures was 2 [1 to 3] (versus 0, p < 0.002). Conclusion. In AF patients in whom the first attempt of TSP fails, the “mosquito” technique allows effective, safe, and time sparing LA access. This approach might facilitate TSP in elastic, aneurysmatic, or fibrosed septa.
Collapse
|
17
|
Morais P, Vilaça JL, Ector J, D'hooge J, Tavares JMRS. Novel Solutions Applied in Transseptal Puncture: A Systematic Review. J Med Device 2017. [DOI: 10.1115/1.4035374] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Access to the left atrium is required for several minimally invasive cardiac interventions in the left heart. For this purpose, transseptal puncture (TSP) technique is often performed, perforating the atrial septum under fluoroscopic or/and ultrasound imaging guidance. Although this approach has been used for many years, complications/failures are not uncommon mainly in patients with abnormal atrial anatomy and repeated TSP. Thus, this study presents an overview of methods and techniques that have been proposed to increase the safety and feasibility of the TSP. A systematic review of literature was conducted through the analysis of the articles published between 2008 and 2015. The search was performed in PubMed, Scopus, and ISI Web of Knowledge using the expression “transseptal puncture.” A total of 354 articles were retrieved from the databases, and 64 articles were selected for this review. Moreover, these 64 articles were divided into four categories, namely: (1) incidence studies, (2) intraprocedural guidance techniques, (3) preprocedural planning methods, and (4) surgical instruments. A total of 36 articles focused on incidence studies, 24 articles suggested novel intraprocedural guidance techniques, 5 works focused on preprocedural planning strategies, and 21 works proposed surgical instruments. The novel 3D guidance techniques, radio-frequency surgical instruments, and pre-interventional planning approaches showed potential to overcome the main procedural limitations/complications, through the reduction of the intervention time, radiation, number of failures, and complications.
Collapse
Affiliation(s)
- Pedro Morais
- ICVS/3B's—PT Government Associate Laboratory, Braga/Guimarães 4710-057, Portugal
- Lab on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven 3000, Belgium
- Instituto de Ciência e Inovação em Engenharia Mecânica e Engenharia Industrial, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal
| | - João L. Vilaça
- ICVS/3B's—PT Government Associate Laboratory, Braga/Guimarães 4710-057, Portugal
- DIGARC—Polytechnic Institute of Cávado and Ave, Vila Frescainha S. Martinho Barcelos 4750-810, Portugal
| | - Joris Ector
- Lab on Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| | - Jan D'hooge
- Lab on Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| | - João Manuel R. S. Tavares
- Instituto de Ciência e Inovação em Engenharia Mecânica e Engenharia Industrial, Departamento de Engenharia Mecânica, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, Porto 4200-465, Portugal e-mail:
| |
Collapse
|
18
|
Sharma G, Singh GD, Smith TW, Fan D, Low RI, Rogers JH. Accuracy and procedural characteristics of standard needle compared with radiofrequency needle transseptal puncture for structural heart interventions. Catheter Cardiovasc Interv 2016; 89:E200-E206. [DOI: 10.1002/ccd.26608] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 04/13/2016] [Accepted: 05/02/2016] [Indexed: 11/09/2022]
Affiliation(s)
- Gaurav Sharma
- Division of Cardiovascular Medicine; University of California Davis Medical Center; Sacramento California
| | - Gagan D. Singh
- Division of Cardiovascular Medicine; University of California Davis Medical Center; Sacramento California
| | - Thomas W. Smith
- Division of Cardiovascular Medicine; University of California Davis Medical Center; Sacramento California
| | - Dali Fan
- Division of Cardiovascular Medicine; University of California Davis Medical Center; Sacramento California
| | - Reginald I. Low
- Division of Cardiovascular Medicine; University of California Davis Medical Center; Sacramento California
| | - Jason H. Rogers
- Division of Cardiovascular Medicine; University of California Davis Medical Center; Sacramento California
| |
Collapse
|
19
|
Abstract
Targeted transseptal puncture remains the most critical initial part of the overall MitraClip procedure. Care and attention must be implemented for patient safety in choosing the optimal puncture site. A consistent and step-by-step methodical approach is recommended. As experienced operators are targeting more complex and nontraditional pathologic conditions, use of adjunctive tools and maneuvers (outlined in this review) are paramount to achieving successful targeted transseptal access and ultimately procedural success.
Collapse
|
20
|
Csanadi Z, Nagy-Baló E, Danik S, Barrett C, Burkhardt JD, Sanchez J, Santangeli P, Santoro F, Di Biase L, Natale A. Cerebrovascular Complications Related to Atrial Fibrillation Ablation and Strategies for Periprocedural Stroke Prevention. Card Electrophysiol Clin 2014; 6:111-123. [PMID: 27063826 DOI: 10.1016/j.ccep.2013.10.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Transcatheter treatment of atrial fibrillation (AF) is a complex intervention performed in patients who are at inherently increased risk of a thromboembolic complication, including stroke. It is therefore not surprising that cerebrovascular accidents have been among the most feared complications since the inception of AF ablation. While improvements have been made to limit the incidence of thromboembolic events during catheter ablation of AF, the optimal strategy to minimize such complications has yet to be determined. It is hoped that larger trials using periprocedural anticoagulation strategies can be undertaken to definitively address these important concerns.
Collapse
Affiliation(s)
- Zoltan Csanadi
- Department of Cardiology, University of Debrecen, 22 Móricz Zs, Debrecen H4032, Hungary.
| | - Edina Nagy-Baló
- Department of Cardiology, University of Debrecen, 22 Móricz Zs, Debrecen H4032, Hungary
| | - Stephan Danik
- Al-Sabah Arrhythmia Institute (AI), St. Luke's Hospital, NY, USA
| | - Conor Barrett
- Al-Sabah Arrhythmia Institute (AI), St. Luke's Hospital, NY, USA
| | - J David Burkhardt
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA
| | - Javier Sanchez
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA
| | - Pasquale Santangeli
- Clinical Cardiac Electrophysiology, University of Pennsylvania, Philadelphia, PA, USA; Department of Cardiology, University of Foggia, Foggia, Italy
| | | | - Luigi Di Biase
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA; Department of Cardiology, University of Foggia, Foggia, Italy; Albert Einstein College of Medicine, Montefiore Hospital, Bronx, NY, USA; Department of Biomedical Engineering, University of Texas, Austin, TX, USA
| | - Andrea Natale
- Case Western Reserve University, Cleveland, OH, USA; Interventional Electrophysiology, Scripps Clinic, San Diego, CA, USA; Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA; Department of Biomedical Engineering, University of Texas, Austin, TX, USA
| |
Collapse
|
21
|
MERCHANT FAISALM, DELURGIO DAVIDB. Catheter Ablation of Atrial Fibrillation and Risk of Asymptomatic Cerebral Embolism. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2014; 37:389-97. [DOI: 10.1111/pace.12336] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2013] [Revised: 10/28/2013] [Accepted: 11/06/2013] [Indexed: 12/21/2022]
Affiliation(s)
- FAISAL M. MERCHANT
- Department of Medicine, Division of Cardiology; Emory University School of Medicine; Atlanta Georgia
| | - DAVID B. DELURGIO
- Department of Medicine, Division of Cardiology; Emory University School of Medicine; Atlanta Georgia
| |
Collapse
|
22
|
Hsu JC, Badhwar N, Gerstenfeld EP, Lee RJ, Mandyam MC, Dewland TA, Imburgia KE, Hoffmayer KS, Vedantham V, Lee BK, Tseng ZH, Scheinman MM, Olgin JE, Marcus GM. Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study). J Am Heart Assoc 2013; 2:e000428. [PMID: 24045120 PMCID: PMC3835257 DOI: 10.1161/jaha.113.000428] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Transseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access. Methods and Results In this prospective, single‐blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK‐1) transseptal needle. In an intention‐to‐treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P=0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P<0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P<0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]). Conclusions Use of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT01209260.
Collapse
Affiliation(s)
- Jonathan C Hsu
- Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of California, San Francisco, San Francisco, CA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|