Sarubbi B, Ciriello GD, Papaccioli G, Correra A, Romeo E, Grimaldi N, Colonna D, Palma M. Combined subcutaneous implantable cardioverter defibrillator and pacemaker devices in complex congenital heart disease: a single-center experienced based study. J Interv Card Electrophysiol 2023:10.1007/s10840-023-01670-1. [PMID: 37878161 DOI: 10.1007/s10840-023-01670-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 10/11/2023] [Indexed: 10/26/2023]
Abstract
BACKGROUND Subcutaneous implantable cardioverter defibrillators (S-ICD) are widely accepted therapy in congenital heart disease (CHD) patients at risk of life-threatening ventricular arrhythmias or sudden cardiac death (SCD) when pacing is not required. Occasionally, pacemaker (PM)-dependent CHD patients will subsequently develop an indication for a cardioverter defibrillator. The use of S-ICD in complex CHD patients who have had already PM devices implanted implies some specific considerations, as the safety for these patients in unknown and recommendations among physicians may vary widely. METHODS We review the data and studied the indications for S-ICD in complex CHD with previous PM and discuss its usefulness in clinical practice. RESULTS From a large cohort of 345 patients enrolled in the S-ICD Monaldi care registry, which encompass all the patients implanted in the Monaldi Hospital of Naples, we considered 11 consecutive complex CHD patients (10M/1F aged 40.4 ±18.4 years) who underwent S-ICD implant after a previous PM implant, from February 2015 to October 2022. Mean follow-up was 25.5 ± 22 months. All the patients showed a good compliance to the device system with no complications (infections or skin erosions). CONCLUSIONS In complex CHD with already implanted PM devices, S-ICD implant appears to be a safe alternative to PM upgrading to transvenous ICD system, avoiding abandoned leads or life-threatening lead extraction. However, there are important issues with regard to testing and programming that need to be addressed at the time of implantation.
Collapse
Affiliation(s)
- Berardo Sarubbi
- Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
| | | | | | - Anna Correra
- Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy
| | - Emanuele Romeo
- Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy
| | - Nicola Grimaldi
- Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy
| | - Diego Colonna
- Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy
| | - Michela Palma
- Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy
| |
Collapse
|
2
|
Okabe T, Savona SJ, Matto F, Ward C, Singh P, Afzal MR, Kalbfleisch SJ, Weiss R, Houmsse M, Augostini RS, Hummel JD, Daoud EG. A 10 J shock impedance in sinus rhythm correlates with a 65 J defibrillation impedance during subcutaneous defibrillator implantation using an intermuscular technique. J Cardiovasc Electrophysiol 2021; 32:3027-3034. [PMID: 34554620 DOI: 10.1111/jce.15249] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 08/14/2021] [Accepted: 08/19/2021] [Indexed: 12/21/2022]
Abstract
INTRODUCTION Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.
Collapse
Affiliation(s)
- Toshimasa Okabe
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Salvatore J Savona
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Faisal Matto
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Chad Ward
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Prabhpreet Singh
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Muhammad R Afzal
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Steven J Kalbfleisch
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Raul Weiss
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Mahmoud Houmsse
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Ralph S Augostini
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - John D Hummel
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Emile G Daoud
- Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| |
Collapse
|
3
|
Sarubbi B, Correra A, Colonna D, Romeo E, Palma M, Merola A, D'Alto M, Scognamiglio G, Fusco F, Barracano R, Borrelli N, Grimaldi N, D'Onofrio A, Russo MG. Subcutaneous implantable cardioverter defibrillator in complex adult congenital heart disease. Results from the S-ICD “Monaldi Care” registry. INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2021. [DOI: 10.1016/j.ijcchd.2021.100091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
4
|
Ip JE. Managing elevated subcutaneous implantable cardioverter-defibrillator defibrillation thresholds: The importance of implantation technique. J Cardiovasc Electrophysiol 2021; 32:1205-1208. [PMID: 33484227 DOI: 10.1111/jce.14909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 11/03/2020] [Accepted: 01/13/2021] [Indexed: 11/26/2022]
Affiliation(s)
- James E Ip
- Department of Medicine, Division of Cardiology, Weill Cornell Medicine, New York Presbyterian Hospital, New York, New York, USA
| |
Collapse
|