1
|
Elbadawi A, Sedhom R, Ghoweba M, Etewa AM, Kayani W, Rahman F. Contemporary Use of Coronary Physiology in Cardiology. Cardiol Ther 2023; 12:589-614. [PMID: 37668939 DOI: 10.1007/s40119-023-00329-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 08/11/2023] [Indexed: 09/06/2023] Open
Abstract
Coronary angiography has a limited ability to predict the functional significance of intermediate coronary lesions. Hence, physiological assessment of coronary lesions, via fractional flow reserve (FFR) or instantaneous wave-free ratio (iFR), has been introduced to determine their functional significance. An accumulating body of evidence has consolidated the role of physiology-guided revascularization, particularly among patients with stable ischemic heart disease. The use of FFR or iFR to guide decision-making in patients with stable ischemic heart disease and intermediate coronary lesions received a class I recommendation from major societal guidelines. Nevertheless, the role of coronary physiology testing is less clear among certain patients' groups, including patients with serial coronary lesions, acute coronary syndromes, aortic stenosis, heart failure, as well as post-percutaneous coronary interventions. In this review, we aimed to discuss the utility and clinical evidence of coronary physiology (mainly FFR and iFR), with emphasis on those specific patient groups.
Collapse
Affiliation(s)
- Ayman Elbadawi
- Division of Cardiology, Christus Good Shepherd, 707 East Marshall Avenue, Longview, TX, 75604, USA.
| | - Ramy Sedhom
- Department of Internal Medicine, Einstein Medical Centre, Philadelphia, PA, USA
| | - Mohamed Ghoweba
- Department of Internal Medicine, Christus Good Shepherd, Longview, TX, 75601, USA
| | | | - Waleed Kayani
- Section of Cardiology, Baylor College of Medicine, Houston, TX, USA
| | - Faisal Rahman
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
2
|
Ilic I, Timcic S, Odanovic N, Otasevic P, Collet C. Serial stenosis assessment-can we rely on invasive coronary physiology. Front Cardiovasc Med 2023; 10:1172906. [PMID: 37200979 PMCID: PMC10185833 DOI: 10.3389/fcvm.2023.1172906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 04/07/2023] [Indexed: 05/20/2023] Open
Abstract
Atherosclerosis is a widespread disease affecting coronary arteries. Diffuse atherosclerotic disease affects the whole vessel, posing difficulties in determining lesion significance by angiography. Research has confirmed that revascularization guided by invasive coronary physiology indices improves patients' prognosis and quality of life. Serial lesions can be a diagnostic challenge because the measurement of functional stenosis significance using invasive physiology is influenced by a complex interplay of factors. The use of fractional flow reserve (FFR) pullback provides a trans-stenotic pressure gradient (ΔP) for each of the lesions. The strategy of treating the lesion with greater ΔP first and then reevaluating another lesion has been advocated. Similarly, non-hyperemic indices can be used to assess the contribution of each stenosis and predict the effect of lesion treatment on physiology indices. Pullback pressure gradient (PPG) integrates physiological variables of coronary pressure along the epicardial vessel and characteristics of discrete and diffuse coronary stenoses into a quantitative index that can be used to guide revascularization. We proposed an algorithm that integrates FFR pullbacks and calculates PPG to determine individual lesion importance and to guide intervention. Computer modeling of the coronaries and the use of non-invasive FFR measurement together with mathematical algorithms for fluid dynamics can make predictions of lesion significance in serial stenoses easier and provide practical solutions for treatment. All these strategies need to be validated before widespread clinical use.
Collapse
Affiliation(s)
- Ivan Ilic
- Institute for Cardiovascular Diseases Dedinje, Belgrade, Serbia
- Medical School, University of Belgrade, Belgrade, Serbia
- Correspondence: Ivan Ilic
| | - Stefan Timcic
- Institute for Cardiovascular Diseases Dedinje, Belgrade, Serbia
| | | | - Petar Otasevic
- Institute for Cardiovascular Diseases Dedinje, Belgrade, Serbia
- Medical School, University of Belgrade, Belgrade, Serbia
| | - Carlos Collet
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
| |
Collapse
|
3
|
Demir OM, Rahman H, van de Hoef TP, Escaned J, Piek JJ, Plein S, Perera D. Invasive and non-invasive assessment of ischaemia in chronic coronary syndromes: translating pathophysiology to clinical practice. Eur Heart J 2021; 43:105-117. [PMID: 34516621 PMCID: PMC8757583 DOI: 10.1093/eurheartj/ehab548] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 03/22/2021] [Accepted: 08/05/2021] [Indexed: 01/10/2023] Open
Abstract
Intracoronary physiology testing has emerged as a valuable diagnostic approach in the management of patients with chronic coronary syndrome, circumventing limitations like inferring coronary function from anatomical assessment and low spatial resolution associated with angiography or non-invasive tests. The value of hyperaemic translesional pressure ratios to estimate the functional relevance of coronary stenoses is supported by a wealth of prognostic data. The continuing drive to further simplify this approach led to the development of non-hyperaemic pressure-based indices. Recent attention has focussed on estimating physiology without even measuring coronary pressure. However, the reduction in procedural time and ease of accessibility afforded by these simplifications needs to be counterbalanced against the increasing burden of physiological assumptions, which may impact on the ability to reliably identify an ischaemic substrate, the ultimate goal during catheter laboratory assessment. In that regard, measurement of both coronary pressure and flow enables comprehensive physiological evaluation of both epicardial and microcirculatory components of the vasculature, although widespread adoption has been hampered by perceived technical complexity and, in general, an underappreciation of the role of the microvasculature. In parallel, entirely non-invasive tools have matured, with the utilization of various techniques including computational fluid dynamic and quantitative perfusion analysis. This review article appraises the strengths and limitations for each test in investigating myocardial ischaemia and discusses a comprehensive algorithm that could be used to obtain a diagnosis in all patients with angina scheduled for coronary angiography, including those who are not found to have obstructive epicardial coronary disease.
Collapse
Affiliation(s)
- Ozan M Demir
- British Heart Foundation Centre of Excellence and National Institute for Health Research Biomedical Research Centre at the School of Cardiovascular Medicine and Sciences, King's College London, Westminster Bridge Road, London SE1 7EH, UK
| | - Haseeb Rahman
- British Heart Foundation Centre of Excellence and National Institute for Health Research Biomedical Research Centre at the School of Cardiovascular Medicine and Sciences, King's College London, Westminster Bridge Road, London SE1 7EH, UK
| | - Tim P van de Hoef
- Department of Clinical and Experimental Cardiology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, Amsterdam 1105 AZ, Netherlands
| | - Javier Escaned
- Department of Cardiology, Hospital Clínico San Carlos IDISCC, Complutense University of Madrid, SpainCalle del Prof Martín Lagos, Madrid 28040, Spain
| | - Jan J Piek
- Department of Clinical and Experimental Cardiology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, Amsterdam 1105 AZ, Netherlands
| | - Sven Plein
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds LS2 9JT, UK
| | - Divaka Perera
- British Heart Foundation Centre of Excellence and National Institute for Health Research Biomedical Research Centre at the School of Cardiovascular Medicine and Sciences, King's College London, Westminster Bridge Road, London SE1 7EH, UK
| |
Collapse
|
4
|
Cernica D, Benedek I, Polexa S, Tolescu C, Benedek T. 3D Printing-A Cutting Edge Technology for Treating Post-Infarction Patients. Life (Basel) 2021; 11:910. [PMID: 34575059 PMCID: PMC8468787 DOI: 10.3390/life11090910] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/25/2021] [Accepted: 08/28/2021] [Indexed: 02/06/2023] Open
Abstract
The increasing complexity of cardiovascular interventions requires advanced peri-procedural imaging and tailored treatment. Three-dimensional printing technology represents one of the most significant advances in the field of cardiac imaging, interventional cardiology or cardiovascular surgery. Patient-specific models may provide substantial information on intervention planning in complex cardiovascular diseases, and volumetric medical imaging from CT or MRI can be translated into patient-specific 3D models using advanced post-processing applications. 3D printing and additive manufacturing have a great variety of clinical applications targeting anatomy, implants and devices, assisting optimal interventional treatment and post-interventional evaluation. Although the 3D printing technology still lacks scientific evidence, its benefits have been shown in structural heart diseases as well as for treatment of complex arrhythmias and corrective surgery interventions. Recent development has enabled transformation of conventional 3D printing into complex 3D functional living tissues contributing to regenerative medicine through engineered bionic materials such hydrogels, cell suspensions or matrix components. This review aims to present the most recent clinical applications of 3D printing in cardiovascular medicine, highlighting also the potential for future development of this revolutionary technology in the medical field.
Collapse
Affiliation(s)
- Daniel Cernica
- Center of Advanced Research in Multimodal Cardiovascular Imaging, Cardio Med Medical Center, 540124 Targu Mures, Romania; (D.C.); (I.B.); (C.T.); (T.B.)
- Cardiology Department, University of Medicine, Pharmacy, Sciences and Technologies “George Emil Palade”, 540142 Targu Mures, Romania
| | - Imre Benedek
- Center of Advanced Research in Multimodal Cardiovascular Imaging, Cardio Med Medical Center, 540124 Targu Mures, Romania; (D.C.); (I.B.); (C.T.); (T.B.)
- Cardiology Department, University of Medicine, Pharmacy, Sciences and Technologies “George Emil Palade”, 540142 Targu Mures, Romania
| | - Stefania Polexa
- Center of Advanced Research in Multimodal Cardiovascular Imaging, Cardio Med Medical Center, 540124 Targu Mures, Romania; (D.C.); (I.B.); (C.T.); (T.B.)
- Cardiology Department, University of Medicine, Pharmacy, Sciences and Technologies “George Emil Palade”, 540142 Targu Mures, Romania
| | - Cosmin Tolescu
- Center of Advanced Research in Multimodal Cardiovascular Imaging, Cardio Med Medical Center, 540124 Targu Mures, Romania; (D.C.); (I.B.); (C.T.); (T.B.)
- Cardiology Department, University of Medicine, Pharmacy, Sciences and Technologies “George Emil Palade”, 540142 Targu Mures, Romania
| | - Theodora Benedek
- Center of Advanced Research in Multimodal Cardiovascular Imaging, Cardio Med Medical Center, 540124 Targu Mures, Romania; (D.C.); (I.B.); (C.T.); (T.B.)
- Cardiology Department, University of Medicine, Pharmacy, Sciences and Technologies “George Emil Palade”, 540142 Targu Mures, Romania
| |
Collapse
|
5
|
Parthasarathy J, Hatoum H, Flemister DC, Krull CM, Walter BA, Zhang W, Mery CM, Molossi S, Jadhav S, Dasi LP, Krishnamurthy R. Assessment of transfer of morphological characteristics of Anomalous Aortic Origin of a Coronary Artery from imaging to patient specific 3D Printed models: A feasibility study. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 201:105947. [PMID: 33535084 DOI: 10.1016/j.cmpb.2021.105947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 01/17/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE This study aims to determine the accuracy of patient specific 3D printed models in capturing pathological anatomical characteristics derived from CT angiography (CTA) in children with anomalous aortic origin of a coronary artery (AAOCA). METHODS & MATERIALS Following institutional regulatory approval, a standardized protocol for CTA of AAOCA was utilized for imaging. Blood volume of the aorta and coronaries were segmented from the DICOM images. A total of 10 models from 8 AAOCA patients were created, including 2 post-operative models. Mechanical properties of Agilus30 a flexible photopolymer coated with a thin layer of parylene, polyurethane (PU) and silicone and native aortic tissue from a postmortem specimen were compared. AAOCA models with wall thicknesses of 2mm aorta and 1.5mm coronaries were 3D printed in Agilus30 and coated with PU. CT of the printed models was performed, and 3D virtual models were generated. Transfer of anatomical characteristics and geometric accuracy were compared between the patient model virtual models. RESULTS Dynamic modulus of Agilus30 at 2mm thickness was found to be close to native aortic tissue. Structured reporting of anatomical characteristics by imaging experts showed good concordance between patient and model CTA Comparative patient and virtual model measurements showed Pearson's correlation (r) of 0.9959 for aorta (n=70) and 0.9538 for coronaries (n=60) linear, and 0.9949 for aorta (n=30) and 0.9538 for coronaries (n=30) cross-sectional, dimensions. Surface contour map mean difference was 0.08 ± 0.29mm. CONCLUSIONS Geometrically accurate AAOCA models preserving morphological characteristics, essential for risk stratification and decision-making, can be 3D printed from a patient's CTA.
Collapse
Affiliation(s)
- Jayanthi Parthasarathy
- Department of Radiology, Nationwide Children's Hospital, The Ohio State University College of Medicine, 700 Children's Dr, E4A Columbus, Columbus, OH 43205, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Hoda Hatoum
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Dorma C Flemister
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Carly M Krull
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Benjamin A Walter
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Wei Zhang
- Department of Biostatistics & Data Science, University of Texas HSC, School of Public Health, Houston USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Carlos M Mery
- Texas Center for Pediatric and Congenital Heart Disease, University of Texas Dell Medical School / Dell Children's Medical Center, Austin, TX, USA
| | - Silvana Molossi
- Texas Center for Pediatric and Congenital Heart Disease, University of Texas Dell Medical School / Dell Children's Medical Center, Austin, TX, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Siddharth Jadhav
- Department of Radiology, Texas Children's Hospital, Baylor College of Medicine Houston, TX, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Lakshmi Prasad Dasi
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA
| | - Rajesh Krishnamurthy
- Department of Radiology, Nationwide Children's Hospital, The Ohio State University College of Medicine, 700 Children's Dr, E4A Columbus, Columbus, OH 43205, USA; Department of Pediatrics, Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, TX, USA.
| |
Collapse
|
6
|
Modi B, Perera D. How to select patients requiring coronary revascularisation using coronary physiology. JRSM Cardiovasc Dis 2021; 10:2048004020979476. [PMID: 33614020 PMCID: PMC7868490 DOI: 10.1177/2048004020979476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 10/29/2020] [Accepted: 11/18/2020] [Indexed: 01/10/2023] Open
Abstract
The coronary angiogram is an indicator of flow limiting coronary artery disease but coronary physiology at the time of angiography is vital in assessing the true functional significance of coronary artery disease. With advances in guidewire technology and the greater use of physiology within the catheter laboratory, there is now a slow evolution of physiological indices in being able to reliably assess the functional significance of individual lesions and also the adequacy of revascularization in a growing range of clinical scenarios. As co-registration of physiology with the angiogram and intravascular imaging will become easier, we will find ourselves increasingly in an era of 'Precision PCI'.
Collapse
Affiliation(s)
- Bhavik Modi
- NIHR Biomedical Research Centre and British Heart Foundation Centre of Excellence, School of Cardiovascular Medicine and Sciences, St Thomas' Campus, King's College London, London, UK
| | - Divaka Perera
- NIHR Biomedical Research Centre and British Heart Foundation Centre of Excellence, School of Cardiovascular Medicine and Sciences, St Thomas' Campus, King's College London, London, UK
| |
Collapse
|
7
|
Ali A, Ballard DH, Althobaity W, Christensen A, Geritano M, Ho M, Liacouras P, Matsumoto J, Morris J, Ryan J, Shorti R, Wake N, Rybicki FJ, Sheikh A. Clinical situations for which 3D printing is considered an appropriate representation or extension of data contained in a medical imaging examination: adult cardiac conditions. 3D Print Med 2020; 6:24. [PMID: 32965536 PMCID: PMC7510265 DOI: 10.1186/s41205-020-00078-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 09/04/2020] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Medical 3D printing as a component of care for adults with cardiovascular diseases has expanded dramatically. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides appropriateness criteria for adult cardiac 3D printing indications. METHODS A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with a number of adult cardiac indications, physiologic, and pathologic processes. Each study was vetted by the authors and graded according to published guidelines. RESULTS Evidence-based appropriateness guidelines are provided for the following areas in adult cardiac care; cardiac fundamentals, perioperative and intraoperative care, coronary disease and ischemic heart disease, complications of myocardial infarction, valve disease, cardiac arrhythmias, cardiac neoplasm, cardiac transplant and mechanical circulatory support, heart failure, preventative cardiology, cardiac and pericardial disease and cardiac trauma. CONCLUSIONS Adoption of common clinical standards regarding appropriate use, information and material management, and quality control are needed to ensure the greatest possible clinical benefit from 3D printing. This consensus guideline document, created by the members of the RSNA 3D printing Special Interest Group, will provide a reference for clinical standards of 3D printing for adult cardiac indications.
Collapse
Affiliation(s)
- Arafat Ali
- Department of Radiology, University of Cincinnati Medical Center, Cincinnati, OH, USA.
| | - David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO, USA
| | - Waleed Althobaity
- King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Andy Christensen
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON, Canada
| | | | - Michelle Ho
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA
| | - Peter Liacouras
- 3D Medical Applications Center, Walter Reed National Military Medical Center, Washington, DC, USA
| | - Jane Matsumoto
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Justin Ryan
- Rady Children's Hospital, San Diego, CA, USA
| | - Rami Shorti
- Intermountain Healthcare, South Jordan, UT, USA
| | - Nicole Wake
- Department of Radiology, Montefiore Medical Center, Bronx, NY, USA
| | - Frank J Rybicki
- Department of Radiology, University of Cincinnati Medical Center, Cincinnati, OH, USA
| | - Adnan Sheikh
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON, Canada
| | | |
Collapse
|
8
|
Modi BN, Rahman H, Ryan M, Ellis H, Pavlidis A, Redwood S, Clapp B, Chowienczyk P, Perera D. Comparison of fractional flow reserve, instantaneous wave-free ratio and a novel technique for assessing coronary arteries with serial lesions. EUROINTERVENTION 2020; 16:577-583. [PMID: 31543499 DOI: 10.4244/eij-d-19-00635] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
AIMS Physiological indices such as fractional flow reserve (FFR), instantaneous wave-free ratio (iFR) and resting distal coronary to aortic pressure (Pd/Pa) are increasingly used to guide revascularisation. However, reliable assessment of individual stenoses in serial coronary disease remains an unmet need. This study aimed to compare conventional pressure-based indices, a reference Doppler-based resistance index (hyperaemic stenosis resistance [hSR]) and a recently described mathematical correction model to predict the contribution of individual stenoses in serial disease. METHODS AND RESULTS Resting and hyperaemic pressure wire pullbacks were performed in 54 patients with serial disease. For each stenosis, FFR, iFR, and Pd/Pa were measured by the translesional gradient in each index and the predicted FFR (FFRpred) derived mathematically from hyperaemic pullback data. "True" stenosis significance by each index was assessed following PCI of the accompanying stenosis or measurements made in a large disease-free branch. In 27 patients, Doppler average peak flow velocity (APV) was also measured to calculate hSR (hSR=∆P/APV, where ∆P=translesional pressure gradient). FFR underestimated individual stenosis severity, inversely proportional to cumulative FFR (r=0.5, p<0.001). Mean errors for FFR, iFR and Pd/Pa were 33%, 20% and 24%, respectively, and 14% for FFRpred (p<0.001). Stenosis misclassification rates based on FFR 0.80, iFR 0.89 and Pd/Pa 0.91 thresholds were not significantly different (17%, 24% and 20%, respectively) but were higher than FFRpred (11%, p<0.001). Apparent and true hSR correlated strongly (r=0.87, p<0.001, mean error 0.19±0.3), with only 7% of stenoses misclassified. CONCLUSIONS Individual stenosis severity is significantly underestimated in the presence of serial disease, using both hyperaemic and resting pressure-based indices. hSR is less prone to error but challenges in optimising Doppler signals limit clinical utility. A mathematical correction model, using data from hyperaemic pressure wire pullback, produces similar accuracy to hSR and is superior to conventional pressure-based indices.
Collapse
Affiliation(s)
- Bhavik N Modi
- NIHR Biomedical Research Centre and British Heart Foundation Centre of Excellence, School of Cardiovascular Medicine and Sciences, St Thomas' Campus, King's College London, London, United Kingdom
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Difference in functional assessment of individual stenosis severity in serial coronary lesions between resting and hyperemic pressure-wire pullback: Insights from the GIFT registry. Int J Cardiol 2020; 312:10-15. [DOI: 10.1016/j.ijcard.2020.05.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 04/19/2020] [Accepted: 05/01/2020] [Indexed: 01/10/2023]
|
10
|
Sommer KN, Shepard LM, Mitsouras D, Iyer V, Angel E, Wilson MF, Rybicki FJ, Kumamaru KK, Sharma UC, Reddy A, Fujimoto S, Ionita CN. Patient-specific 3D-printed coronary models based on coronary computed tomography angiography volumes to investigate flow conditions in coronary artery disease. Biomed Phys Eng Express 2020; 6:045007. [PMID: 33444268 DOI: 10.1088/2057-1976/ab8f6e] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND 3D printed patient-specific coronary models have the ability to enable repeatable benchtop experiments under controlled blood flow conditions. This approach can be applied to CT-derived patient geometries to emulate coronary flow and related parameters such as Fractional Flow Reserve (FFR). METHODS This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements. Fifty-two patients with a clinical indication for I-FFR underwent a research Coronary CT Angiography (CCTA) prior to catheterization. CT images were used to measure CT-FFR and to generate patient-specific 3D printed models of the aortic root and three main coronary arteries. Each patient-specific model was connected to a programmable pulsatile pump and benchtop FFR (B-FFR) was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. B-FFR was measured for two coronary outflow rates ('normal', 250 ml min-1; and 'hyperemic', 500 ml min-1) by adjusting the model's distal coronary resistance. RESULTS Pearson correlations and ROC AUC were calculated using invasive I-FFR as reference. The Pearson correlation factor of CT-FFR and B-FFR-500 was 0.75 and 0.71, respectively. Areas under the ROCs for CT-FFR and B-FFR-500 were 0.80 (95%CI: 0.70-0.87) and 0.81 (95%CI: 0.64-0.91) respectively. CONCLUSION Benchtop flow simulations with 3D printed models provide the capability to measure pressure changes at any location in the model, for ultimately emulating the FFR at several simulated physiological blood flow conditions. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov/show/NCT03149042.
Collapse
Affiliation(s)
- Kelsey N Sommer
- Department of Biomedical Engineering, University at Buffalo, Buffalo, NY 14228, United States of America. Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, United States of America
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Warisawa T, Cook CM, Howard JP, Ahmad Y, Doi S, Nakayama M, Goto S, Yakuta Y, Karube K, Shun-Shin MJ, Petraco R, Sen S, Nijjer S, Al Lamee R, Ishibashi Y, Matsuda H, Escaned J, di Mario C, Francis DP, Akashi YJ, Davies JE. Physiological Pattern of Disease Assessed by Pressure-Wire Pullback Has an Influence on Fractional Flow Reserve/Instantaneous Wave-Free Ratio Discordance. Circ Cardiovasc Interv 2020; 12:e007494. [PMID: 31084237 PMCID: PMC6553990 DOI: 10.1161/circinterventions.118.007494] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
BACKGROUND Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) disagree on the hemodynamic significance of a coronary lesion in ≈20% of cases. It is unknown whether the physiological pattern of disease is an influencing factor for this. This study assessed whether the physiological pattern of coronary artery disease influences discordance between FFR and iFR measurement. METHODS AND RESULTS Three-hundred and sixty intermediate coronary lesions (345 patients; mean age, 64.4±10.3 years; 76% men) with combined FFR, iFR, and iFR pressure-wire pullback were included for analysis from an international multicenter registry. Cut points for hemodynamic significance were FFR ≤0.80 and iFR ≤0.89, respectively. Lesions were classified into FFR+/iFR+ (n=154; 42.7%), FFR-/iFR+ (n=38; 10.6%), FFR+/iFR- (n=41; 11.4%), and FFR-/iFR- (n=127; 35.3%) groups. The physiological pattern of disease was classified according to the iFR pullback recordings as predominantly physiologically focal (n=171; 47.5%) or predominantly physiologically diffuse (n=189; 52.5%). Median FFR and iFR were 0.80 (interquartile range, 0.75-0.85) and 0.89 (interquartile range, 0.86-0.92), respectively. FFR disagreed with iFR in 22% (79 of 360). The physiological pattern of disease was the only influencing factor relating to FFR/iFR discordance: predominantly physiologically focal was significantly associated with FFR+/iFR- (58.5% [24 of 41]), and predominantly physiologically diffuse was significantly associated with FFR-/iFR+ (81.6% [31 of 38]; P<0.001 for pattern of disease between FFR+/iFR- and FFR-/iFR+ groups). CONCLUSIONS The physiological pattern of coronary artery disease was an important influencing factor for FFR/iFR discordance.
Collapse
Affiliation(s)
- Takayuki Warisawa
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.).,Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan (T.W., Y.I., Y.J.A.)
| | - Christopher M Cook
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - James P Howard
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Yousif Ahmad
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Shunichi Doi
- Department of Cardiovascular Medicine, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, Japan (S.D., H.M.)
| | - Masafumi Nakayama
- Cardiovascular Center, Toda Central General Hospital, Japan (M.N., S.G.).,Tokyo Women's Medical University-Waseda University Joint Institution for Advanced Biomedical Sciences, Japan (M.N.)
| | - Sonoka Goto
- Cardiovascular Center, Toda Central General Hospital, Japan (M.N., S.G.).,Cardiovascular Institute, Hospital Clínico San Carlos, Madrid, Spain (S.G., J.E.)
| | - Yohei Yakuta
- Department of Cardiology, Kanazawa Cardiovascular Hospital, Japan (Y.Y.)
| | - Kenichi Karube
- Department of Cardiovascular Medicine, Okaya City Hospital, Japan (K.K.)
| | - Matthew J Shun-Shin
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Ricardo Petraco
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Sayan Sen
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Sukhjinder Nijjer
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Rasha Al Lamee
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Yuki Ishibashi
- Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan (T.W., Y.I., Y.J.A.)
| | - Hisao Matsuda
- Department of Cardiovascular Medicine, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, Japan (S.D., H.M.)
| | - Javier Escaned
- Cardiovascular Institute, Hospital Clínico San Carlos, Madrid, Spain (S.G., J.E.)
| | - Carlo di Mario
- Structural Interventional Cardiology, Careggi University Hospital, Florence, Italy (C.d.M.)
| | - Darrel P Francis
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| | - Yoshihiro J Akashi
- Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan (T.W., Y.I., Y.J.A.)
| | - Justin E Davies
- International Center for Circulatory Health, National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom (T.W., C.M.C., J.P.H., Y.A., M.J.S.-S., R.P., S.S., S.N., R.A.L., D.P.F., J.E.D.)
| |
Collapse
|
12
|
Sun Z. Use of Three-dimensional Printing in the Development of Optimal Cardiac CT Scanning Protocols. Curr Med Imaging 2020; 16:967-977. [PMID: 32107994 DOI: 10.2174/1573405616666200124124140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Revised: 11/22/2019] [Accepted: 11/27/2019] [Indexed: 01/01/2023]
Abstract
Three-dimensional (3D) printing is increasingly used in medical applications with most of the studies focusing on its applications in medical education and training, pre-surgical planning and simulation, and doctor-patient communication. An emerging area of utilising 3D printed models lies in the development of cardiac computed tomography (CT) protocols for visualisation and detection of cardiovascular disease. Specifically, 3D printed heart and cardiovascular models have shown potential value in the evaluation of coronary plaques and coronary stents, aortic diseases and detection of pulmonary embolism. This review article provides an overview of the clinical value of 3D printed models in these areas with regard to the development of optimal CT scanning protocols for both diagnostic evaluation of cardiovascular disease and reduction of radiation dose. The expected outcomes are to encourage further research towards this direction.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, 6845, Australia
| |
Collapse
|
13
|
Measurement of Hyperemic Pullback Pressure Gradients to Characterize Patterns of Coronary Atherosclerosis. J Am Coll Cardiol 2019; 74:1772-1784. [DOI: 10.1016/j.jacc.2019.07.072] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 07/05/2019] [Accepted: 07/21/2019] [Indexed: 11/22/2022]
|
14
|
Modi BN, Ryan M, Chattersingh A, Eruslanova K, Ellis H, Gaddum N, Lee J, Clapp B, Chowienczyk P, Perera D. Optimal Application of Fractional Flow Reserve to Assess Serial Coronary Artery Disease: A 3D-Printed Experimental Study With Clinical Validation. J Am Heart Assoc 2018; 7:e010279. [PMID: 30371265 PMCID: PMC6474982 DOI: 10.1161/jaha.118.010279] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 08/20/2018] [Indexed: 01/10/2023]
Abstract
Background Assessing the physiological significance of stenoses with coexistent serial disease is prone to error. We aimed to use 3-dimensional-printing to characterize serial stenosis interplay and to derive and validate a mathematical solution to predict true stenosis significance in serial disease. Methods and Results Fifty-two 3-dimensional-printed serial disease phantoms were physiologically assessed by pressure-wire pullback (Δ FFR app) and compared with phantoms with the stenosis in isolation (Δ FFR true). Mathematical models to minimize error in predicting FFR true, the FFR in the vessel where the stenosis is present in isolation, were subsequently developed using 32 phantoms and validated in another 20 and also a clinical cohort of 30 patients with serial disease. Δ FFR app underestimated Δ FFR true in 88% of phantoms, with underestimation proportional to total FFR . Discrepancy as a proportion of Δ FFR true was 17.1% (absolute difference 0.036±0.048), which improved to 2.9% (0.006±0.023) using our model. In the clinical cohort, discrepancy was 38.5% (0.05±0.04) with 13.3% of stenoses misclassified (using FFR <0.8 threshold). Using mathematical correction, this improved to 15.4% (0.02±0.03), with the proportion of misclassified stenoses falling to 6.7%. Conclusions Individual stenoses are considerably underestimated in serial disease, proportional to total FFR . We have shown within in vitro and clinical cohorts that this error is significantly improved using a mathematical correction model, incorporating routinely available pressure-wire pullback data.
Collapse
Affiliation(s)
- Bhavik N. Modi
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Matthew Ryan
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Anjalee Chattersingh
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Kseniia Eruslanova
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Howard Ellis
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Nicholas Gaddum
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUnited Kingdom
| | - Jack Lee
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUnited Kingdom
| | - Brian Clapp
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Phil Chowienczyk
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| | - Divaka Perera
- NIHR Biomedical Research Centre and British Heart Foundation Centre of ExcellenceSchool of Cardiovascular Medicine and SciencesSt Thomas’ CampusKing's College LondonLondonUnited Kingdom
| |
Collapse
|
15
|
Sezer M. New Mathematical Correction Model in Pursuit of Optimal Hemodynamic Assessment of Serial Coronary Artery Disease: Overcoming Hyperemic Cross Talk Between Coronary Stenoses in Series? J Am Heart Assoc 2018; 7:e010754. [PMID: 30371268 PMCID: PMC6474979 DOI: 10.1161/jaha.118.010754] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Murat Sezer
- Department of CardiologyIstanbul UniversityIstanbulTurkey
| |
Collapse
|