Wiedbrauck D, Karczewski M, Schoenberg SO, Fink C, Kayed H. Artificial Intelligence-Based Emphysema Quantification in Routine Chest Computed Tomography: Correlation With Spirometry and Visual Emphysema Grading.
J Comput Assist Tomogr 2024;
48:388-393. [PMID:
38110294 DOI:
10.1097/rct.0000000000001572]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2023]
Abstract
OBJECTIVE
The aim of the study is to assess the correlation between artificial intelligence (AI)-based low attenuation volume percentage (LAV%) with forced expiratory volume in the first second to forced vital capacity (FEV1/FVC) and visual emphysema grades in routine chest computed tomography (CT). Furthermore, optimal LAV% cutoff values for predicting a FEV1/FVC < 70% or moderate to more extensive visual emphysema grades were calculated.
METHODS
In a retrospective study of 298 consecutive patients who underwent routine chest CT and spirometry examinations, LAV% was quantified using an AI-based software with a threshold < -950 HU. The FEV1/FVC was derived from spirometry, with FEV1/FVC < 70% indicating airway obstruction. The mean time interval of CT from spirometry was 3.87 ± 4.78 days. Severity of emphysema was visually graded by an experienced chest radiologist using an established 5-grade ordinal scale (Fleischner Society classification system). Spearman correlation coefficient between LAV% and FEV1/FVC was calculated. Receiver operating characteristic determined the optimal LAV% cutoff values for predicting a FEV1/FVC < 70% or a visual emphysema grade of moderate or higher (Fleischner grade 3-5).
RESULTS
Significant correlation between LAV% and FEV1/FVC was found (ϱ = -0.477, P < 0.001). Increasing LAV% corresponded to higher visual emphysema grades. For patients with absent visual emphysema, mean LAV% was 2.98 ± 3.30, for patients with trace emphysema 3.22 ± 2.75, for patients with mild emphysema 3.90 ± 3.33, for patients with moderate emphysema 6.41 ± 3.46, for patients with confluent emphysema 9.02 ± 5.45, and for patients with destructive emphysema 16.90 ± 8.19. Optimal LAV% cutoff value for predicting a FEV1/FVC < 70 was 6.1 (area under the curve = 0.764, sensitivity = 0.773, specificity = 0.665), while for predicting a visual emphysema grade of moderate or higher, it was 4.7 (area under the curve = 0.802, sensitivity = 0.766, specificity = 0.742). Furthermore, correlation between visual emphysema grading and FEV1/FVC was found. In patients with FEV1/FVC < 70% a high proportion of subjects had emphysema grade 3 (moderate) or higher, whereas in patients with FEV1/FVC ≥ 70%, a larger proportion had emphysema grade 3 (moderate) or lower. The sensitivity for visual emphysema grading predicting a FEV1/FVC < 70% was 56.3% with an optimal cutoff point at a visual grade of 4 (confluent), demonstrating a lower sensitivity compared with LAV% (77.3%).
CONCLUSIONS
A significant correlation between AI-based LAV% and FEV1/FVC as well as visual CT emphysema grades can be found in routine chest CT suggesting that AI-based LAV% measurement might be integrated as an add-on functional parameter in the evaluation of chest CT in the future.
Collapse