1
|
Li G, Wang B, Li L, Li X, Yan R, Liang J, Zhou X, Li L, Zhou Z. H-rGO-Pd NPs Nanozyme Enhanced Silver Deposition Strategy for Electrochemical Detection of Glypican-3. Molecules 2023; 28:molecules28052271. [PMID: 36903516 PMCID: PMC10004744 DOI: 10.3390/molecules28052271] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 02/11/2023] [Accepted: 02/15/2023] [Indexed: 03/05/2023] Open
Abstract
Glypican-3 (GPC3), as an emerging biomarker, has been shown to be beneficial for the early diagnosis and treatment of hepatocellular carcinoma (HCC). In this study, an ultrasensitive electrochemical biosensor for GPC3 detection has been constructed based on the hemin-reduced graphene oxide-palladium nanoparticles (H-rGO-Pd NPs) nanozyme-enhanced silver deposition signal amplification strategy. When GPC3 specifically interacted with GPC3 antibody (GPC3Ab) and GPC3 aptamer (GPC3Apt), an "H-rGO-Pd NPs-GPC3Apt/GPC3/GPC3Ab" sandwich complex was formed with peroxidase-like properties which enhanced H2O2 to reduce the silver (Ag) ions in solution to metallic Ag, resulting in the deposition of silver nanoparticles (Ag NPs) on the surface of the biosensor. The amount of deposited Ag, which was derived from the amount of GPC3, was quantified by the differential pulse voltammetry (DPV) method. Under ideal circumstances, the response value was linearly correlated with GPC3 concentration at 10.0-100.0 μg/mL with R2 of 0.9715. When the GPC3 concentration was in the range from 0.01 to 10.0 μg/mL, the response value was logarithmically linear with the GPC3 concentration with R2 of 0.9941. The limit of detection was 3.30 ng/mL at a signal-to-noise ratio of three and the sensitivity was 1.535 μAμM-1cm-2. Furthermore, the electrochemical biosensor detected the GPC3 level in actual serum samples with good recoveries (103.78-106.52%) and satisfactory relative standard deviations (RSDs) (1.89-8.81%), which confirmed the applicability of the sensor in practical applications. This study provides a new analytical method for measuring the level of GPC3 in the early diagnosis of HCC.
Collapse
Affiliation(s)
- Guiyin Li
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
- College of Chemistry, Guangdong University of Petrochemical Technology, Guandu Road, Maoming 525000, China
| | - Bo Wang
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
| | - Ling Li
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
| | - Xinhao Li
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
| | - Ruijie Yan
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
| | - Jintao Liang
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
| | - Xinchun Zhou
- Guangdi Maoming Chemical Co., Ltd., Maoming High-Tech Industrial Development Zone, Maoming 525000, China
- Correspondence: (X.Z.); (L.L.); (Z.Z.)
| | - Liuxun Li
- Solid Tumour Target Discovery Laboratory, Translational and Clinical Research Institute, Newcastle University Centre for Cancer, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne NE2 4HH, UK
- Correspondence: (X.Z.); (L.L.); (Z.Z.)
| | - Zhide Zhou
- Guangxi Key Laboratory of Information Materials, School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
- Correspondence: (X.Z.); (L.L.); (Z.Z.)
| |
Collapse
|
2
|
Li G, Xue Y, Wang C, Li X, Li S, Huang Y, Zhou Z. Persimmon Tannin-Reduction Graphene Oxide-Platinum-Palladium Nanocomposite Decorated on Screen-Printed Carbon Electrode for Enhanced Electrocatalytic Reduction of Hydrogen Peroxide. J Biomed Nanotechnol 2022. [DOI: 10.1166/jbn.2022.3353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
According to studies, Hydrogen peroxide (H2O2) is a significant biomarker of physiological processes. Unnormal H2O2 levels in human body may result in diseases. Hence, there is an increasing demand for monitoring the H2O2
concentrations in biological specimen. Here, we construct a non-enzymatic H2O2 electrochemical biosensor based on persimmon tannin-reduced graphene oxide-platinum-palladium nanocomposite (PrG-Pt@Pd NPs) modified with screen-printed carbon electrode (SPE). Combined with
suitable electrocatalytic mode for Pt@Pd NPs, high specific large specific volume and good electrical conductivity of RGO, well as the superior sorption capacity of PT for metal-based nano-ion, the PrGPt@Pd striped pleasing heterogeneous catalytic activity toward H2O2
reduction via the synergistic effect. In experimental conditions of optimal, this non-enzymatic electrochemical sensor exhibited excellent electrocatalytic performance for H2O2 with less negative potential (−0.5 V), fast response time (<3 s), it shows good linearity
in the range of 5.0–100.0 μM, in addition to this LOD of this sensor was 0.059 μM as well as the excellent sensitivity of the sensor (13.696 μA·μM−1·cm−2). Due to excellent specificity, lower detection
limit, and good recovery (98.70–99.96%) in the spiked measurements of human serum samples, this non-enzymatic electrochemical biosensor paves the way for H2O2 detection at ultra-low concentrations in physiology and diagnosis.
Collapse
Affiliation(s)
- Guiyin Li
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, 525000, People’s Republic of China
| | - Yewei Xue
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People’s Republic of China
| | - Chaoxian Wang
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, 525000, People’s Republic of China
| | - Xinhao Li
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People’s Republic of China
| | - Shengnan Li
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People’s Republic of China
| | - Yong Huang
- National Center for International Research of Biological Targeting Diagnosis and Therapy, Guangxi Key Laboratory of Biological Targeting Diagnosis and Therapy Research, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy,
Guangxi Medical University, Nanning, Guangxi, 530021, China
| | - Zhide Zhou
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People’s Republic of China
| |
Collapse
|