1
|
Obana A, Ote K, Gohto Y, Yamada H, Hashimoto F, Okazaki S, Asaoka R. Deep learning-based correction of cataract-induced influence on macular pigment optical density measurement by autofluorescence spectroscopy. PLoS One 2024; 19:e0298132. [PMID: 38349916 PMCID: PMC10863874 DOI: 10.1371/journal.pone.0298132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 01/19/2024] [Indexed: 02/15/2024] Open
Abstract
PURPOSE Measurements of macular pigment optical density (MPOD) using the autofluorescence spectroscopy yield underestimations of actual values in eyes with cataracts. Previously, we proposed a correction method for this error using deep learning (DL); however, the correction performance was validated through internal cross-validation. This cross-sectional study aimed to validate this approach using an external validation dataset. METHODS MPODs at 0.25°, 0.5°, 1°, and 2° eccentricities and macular pigment optical volume (MPOV) within 9° eccentricity were measured using SPECTRALIS (Heidelberg Engineering, Heidelberg, Germany) in 197 (training dataset inherited from our previous study) and 157 eyes (validating dataset) before and after cataract surgery. A DL model was trained to predict the corrected value from the pre-operative value using the training dataset, and we measured the discrepancy between the corrected value and the actual postoperative value. Subsequently, the prediction performance was validated using a validation dataset. RESULTS Using the validation dataset, the mean absolute values of errors for MPOD and MPOV corrected using DL ranged from 8.2 to 12.4%, which were lower than values with no correction (P < 0.001, linear mixed model with Tukey's test). The error depended on the autofluorescence image quality used to calculate MPOD. The mean errors in high and moderate quality images ranged from 6.0 to 11.4%, which were lower than those of poor quality images. CONCLUSION The usefulness of the DL correction method was validated. Deep learning reduced the error for a relatively good autofluorescence image quality. Poor-quality images were not corrected.
Collapse
Affiliation(s)
- Akira Obana
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu City, Shizuoka, Japan
- Department of Medical Spectroscopy, Institute for Medical Photonics Research, Preeminent Medical Photonics Education & Research Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Kibo Ote
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Yuko Gohto
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu City, Shizuoka, Japan
| | - Hidenao Yamada
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Fumio Hashimoto
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Shigetoshi Okazaki
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Ryo Asaoka
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu City, Shizuoka, Japan
| |
Collapse
|
2
|
Morita H, Matsushita I, Fujino Y, Obana A, Kondo H. Measuring macular pigment optical density using reflective images of confocal scanning laser system. Jpn J Ophthalmol 2024; 68:19-25. [PMID: 37966565 DOI: 10.1007/s10384-023-01031-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 10/10/2023] [Indexed: 11/16/2023]
Abstract
PURPOSE To develop a method to measure the macular pigment optical density (MPOD) using scanning laser ophthalmoscopic images in young adults and children. STUDY DESIGN Cross-sectional study. METHODS Blue light reflectance fundus images of 32 healthy subjects were used. A profile of the linear reflectance changes across the center of the fovea on a grayscale fundus image was generated. The ratio of the macula-to-periphery reflection was designated as the peak value of the MPOD (MPOD[FR]) based on established fundamentals. In the MPOD profile, the basal width of the pixels at MPOD < 0 (wMP) and width at one-half value of the MPOD[FR] (wMP0.5) were determined. The MOPD at eccentricity of 0.5° was measured by heterochromatic flicker photometry (MPOD[HFP]), and the correlation between the MPOD[FR] and MPOD[HFP] was evaluated. RESULTS The MPOD[FR] ranged from 0.17 to 0.73 with a mean of 0.40 ± 0.13. The wMP ranged from 88 to 173 pixels with a mean of 121.7 ± 24.2 pixels, and the wMP0.5 ranged from 38 to 83 pixels with a mean of 54.1 ± 10.3 pixels. A significant correlation was found between the MPOD[FR] and MPOD[HFP] (r = 0.41, P = 0.02). CONCLUSIONS This simplified method can provide accurate and reliable values of the MPOD comparable to heterochromatic flicker photometry. Obtaining the fundus images in this fast and easy way should be suitable for children thus enabling clinicians to determine the MPODs for children.
Collapse
Affiliation(s)
- Hirofumi Morita
- Department of Ophthalmology, University of Occupational and Environmental Health, 1-1, Iseigaoka, Yahatanishiku, Kitakyushu, 807-8555, Japan
| | - Itsuka Matsushita
- Department of Ophthalmology, University of Occupational and Environmental Health, 1-1, Iseigaoka, Yahatanishiku, Kitakyushu, 807-8555, Japan
| | - Yoshihisa Fujino
- Department of Environmental Epidemiology, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Akira Obana
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Japan
| | - Hiroyuki Kondo
- Department of Ophthalmology, University of Occupational and Environmental Health, 1-1, Iseigaoka, Yahatanishiku, Kitakyushu, 807-8555, Japan.
| |
Collapse
|
3
|
Tsujinaka H, Saeki K, Obayashi K, Nishi T, Ueda T, Ogata N. Positive Association between Macular Pigment Optical Density and Glomerular Filtration Rate: A Cross-Sectional Study. J Clin Med 2023; 12:5312. [PMID: 37629352 PMCID: PMC10456087 DOI: 10.3390/jcm12165312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 08/11/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023] Open
Abstract
Although decreased macular pigment density is associated with the development of age-related macular degeneration (AMD), exactly how this decrease may contribute to the development of AMD is still not fully understood. In this study, we investigated the relationship between macular pigment optical density (MPOD) and estimated glomerular filtration rate (eGFR). MPOD was measured using MPS II (Electron Technology, Cambridge, UK) in 137 participants who showed no clinical signs of AMD at 3 months after cataract surgery, and simple and multiple linear regression analyses were performed to determine the associations with age, sex, abdominal circumference, diabetes, hypertension, smoking, intraocular lens color, visual acuity before and after surgery, and eGFR. The participants were divided into two groups based on the median MPOD (0.58): the high-pigment and low-pigment groups. The mean value of eGFR in the high-pigment group was significantly higher than that in the low-pigment group (64.2 vs. 58.1, p = 0.02). The simple linear regression analysis revealed a significant positive association between MPOD and eGFR (β = 0.0034, 95% confidence interval [CI]: 0.0011-0.0056, p = 0.0038), and this association was independent of age, sex, abdominal circumference, diabetes, smoking, hypertension, best-corrected visual acuity (BCVA) before surgery, BCVA after surgery, and intraocular lens color (β = 0.0033, 95% CI: 0.00090-0.0058, p = 0.0076). These results show a strong association of renal dysfunction with the decrease in MPOD.
Collapse
Affiliation(s)
- Hiroki Tsujinaka
- Department of Ophthalmology, Nara Medical University, Kashihara 634-8521, Nara, Japan; (H.T.)
| | - Keigo Saeki
- Department of Epidemiology, Nara Medical University, Kashihara 634-8521, Nara, Japan
| | - Kenji Obayashi
- Department of Epidemiology, Nara Medical University, Kashihara 634-8521, Nara, Japan
| | - Tomo Nishi
- Department of Ophthalmology, Nara Medical University, Kashihara 634-8521, Nara, Japan; (H.T.)
| | - Tetsuo Ueda
- Department of Ophthalmology, Nara Medical University, Kashihara 634-8521, Nara, Japan; (H.T.)
| | - Nahoko Ogata
- Department of Ophthalmology, Nara Medical University, Kashihara 634-8521, Nara, Japan; (H.T.)
| |
Collapse
|
4
|
McGwin G, Kar D, Berlin A, Clark ME, Swain TA, Crosson JN, Sloan KR, Owsley C, Curcio CA. Macular and Plasma Xanthophylls Are Higher in Age-related Macular Degeneration than in Normal Aging: Alabama Study on Early Age-related Macular Degeneration 2 Baseline. OPHTHALMOLOGY SCIENCE 2023; 3:100263. [PMID: 36864830 PMCID: PMC9972499 DOI: 10.1016/j.xops.2022.100263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 11/04/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
Purpose Quantification of retinal xanthophyll carotenoids in eyes with and without age-related macular degeneration (AMD) via macular pigment optical volume (MPOV), a metric for xanthophyll abundance from dual wavelength autofluorescence, plus correlations to plasma levels, could clarify the role of lutein (L) and zeaxanthin (Z) in health, AMD progression, and supplementation strategies. Design Cross-sectional observational study (NCT04112667). Participants Adults ≥ 60 years from a comprehensive ophthalmology clinic, with healthy maculas or maculas meeting fundus criteria for early or intermediate AMD. Methods Macular health and supplement use was assessed by the Age-related Eye Disease Study (AREDS) 9-step scale and self-report, respectively. Macular pigment optical volume was measured from dual wavelength autofluorescence emissions (Spectralis, Heidelberg Engineering). Non-fasting blood draws were assayed for L and Z using high-performance liquid chromatography. Associations among plasma xanthophylls and MPOV were assessed adjusting for age. Main Outcome Measures Age-related macular degeneration presence and severity, MPOV in fovea-centered regions of radius 2.0° and 9.0°; plasma L and Z (μM/ml). Results Of 809 eyes from 434 persons (89% aged 60-79, 61% female), 53.3% eyes were normal, 28.2% early AMD, and 18.5% intermediate AMD. Macular pigment optical volume 2° and 9° were similar in phakic and pseudophakic eyes, which were combined for analysis. Macular pigment optical volume 2° and 9° and plasma L and Z were higher in early AMD than normal and higher still in intermediate AMD (P < 0.0001). For all participants, higher plasma L was correlated with higher MPOV 2° (Spearman correlation coefficient [Rs] = 0.49; P < 0.0001). These correlations were significant (P < 0.0001) but lower in normal (Rs = 0.37) than early and intermediate AMD (Rs = 0.52 and 0.51, respectively). Results were similar for MPOV 9°. Plasma Z, MPOV 2°, and MPOV 9° followed this same pattern of associations. Associations were not affected by supplement use or smoking status. Conclusions A moderate positive correlation of MPOV with plasma L and Z comports with regulated xanthophyll bioavailability and a hypothesized role for xanthophyll transfer in soft drusen biology. An assumption that xanthophylls are low in AMD retina underlies supplementation strategies to reduce progression risk, which our data do not support. Whether higher xanthophyll levels in AMD are due to supplement use cannot be determined in this study.
Collapse
Key Words
- ALSTAR2, Alabama Study on Early Age-related Macular Degeneration 2
- AMD, age-related macular degeneration
- AREDS, age-related eye disease studies
- Age-related macular degeneration
- Autofluorescence
- BrM, Bruch’s membrane
- HDL, high density lipoprotein
- L, Lutein
- Lutein
- MP, macular pigment
- MPOD, macular pigment optical density
- MPOV, macular pigment optical volume
- Macular xanthophyll pigment
- RPE, retinal pigment epithelium
- Z, Zeaxanthin
- Zeaxanthin
Collapse
Affiliation(s)
- Gerald McGwin
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
- Department of Epidemiology, School of Public Health, University of Alabama at Birmingham, Birmingham, Alabama
| | - Deepayan Kar
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
| | - Andreas Berlin
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
- Department of Ophthalmology, University Hospital Wurzburg, Wurzburg, Germany
| | - Mark E. Clark
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
| | - Thomas A. Swain
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
- Department of Epidemiology, School of Public Health, University of Alabama at Birmingham, Birmingham, Alabama
| | - Jason N. Crosson
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
- Retina Consultants of Alabama, Birmingham, Alabama
| | - Kenneth R. Sloan
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
- Department of Computer Science, School of Arts and Sciences, University of Alabama at Birmingham, Birmingham, Alabama
| | - Cynthia Owsley
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
| | - Christine A. Curcio
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
| |
Collapse
|
5
|
Lutein and Zeaxanthin Distribution in the Healthy Macula and Its Association with Various Demographic Factors Examined in Pseudophakic Eyes. Antioxidants (Basel) 2021; 10:antiox10121857. [PMID: 34942960 PMCID: PMC8698861 DOI: 10.3390/antiox10121857] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/18/2021] [Accepted: 11/19/2021] [Indexed: 02/06/2023] Open
Abstract
The macular pigment consisting of lutein (L) and zeaxanthin (Z) protects photoreceptors via its antioxidative and barrier activities. This study aimed to determine L and Z distribution in the healthy macula and their association with various demographic factors. Macular pigment optical density (MPOD) was measured using fundus autofluorescence spectroscopy in 352 pseudophakic eyes with no fundus diseases. Pseudophakia was chosen to avoid the influence of cataract in the measurement of fundus autofluorescence. The mean patient age was 72.3 ± 8.6 years. MPOD was analyzed separately in three zones, i.e., A: a central area within a radius of 0.5°, mainly containing Z; B: a ring area with radii from 0.5° to 1.3°, containing Z and L; C: a ring area with radii from 1.3° to 9°, containing L. Multivariate analyses were performed with MPOD as the dependent variable and sex, supplement intake, smoking habits, glaucoma, diabetes, age, body mass index (BMI), skin carotenoid levels, retinal thickness, retinal volume, axial length as the independent variables. The mean total MPOD volume within 9° eccentricity was 20,121 ± 6293. Age was positively associated with MPOD in all zones. Supplement and BMI were positively and negatively associated with MPOD in zones B and C. Smoking was negatively associated with MPOD in zone A. This study revealed the standard MP values of aged Japanese, which resulted to be higher than the previously reported values in other races. Age was found to have a positive association with MP values. L in the outer foveola was affected by BMI and supplements, but Z in the foveola was not. The amount of Z in the Müller cell cone may not be changed easily by factors such as hunger and satiety in the context of preservation of homeostasis in the human body, but tobacco had a negative effect on Z.
Collapse
|
6
|
Obana A, Ote K, Hashimoto F, Asaoka R, Gohto Y, Okazaki S, Yamada H. Correction for the Influence of Cataract on Macular Pigment Measurement by Autofluorescence Technique Using Deep Learning. Transl Vis Sci Technol 2021; 10:18. [PMID: 34003903 PMCID: PMC7884288 DOI: 10.1167/tvst.10.2.18] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Measurements of macular pigment optical density (MPOD) by the autofluorescence technique yield underestimations of actual values in eyes with cataract. We applied deep learning (DL) to correct this error. Subjects and Methods MPOD was measured by SPECTRALIS (Heidelberg Engineering, Heidelberg, Germany) in 197 eyes before and after cataract surgery. The nominal MPOD values (= preoperative value) were corrected by three methods: the regression equation (RE) method, subjective classification (SC) method (described in our previous study), and DL method. The errors between the corrected and true values (= postoperative value) were calculated for local MPODs at 0.25°, 0.5°, 1°, and 2° eccentricities and macular pigment optical volume (MPOV) within 9° eccentricity. Results The mean error for MPODs at four eccentricities was 32% without any correction, 15% with correction by RE, 16% with correction by SC, and 14% with correction by DL. The mean error for MPOV was 21% without correction and 14%, 10%, and 10%, respectively, with correction by the same methods. The errors with any correction were significantly lower than those without correction (P < 0.001, linear mixed model with Tukey's test). The errors with DL correction were significantly lower than those with RE correction in MPOD at 1° eccentricity and MPOV (P < 0.001) and were equivalent to those with SC correction. Conclusions The objective method using DL was useful to correct MPOD values measured in aged people. Translational Relevance MPOD can be obtained with small errors in eyes with cataract using DL.
Collapse
Affiliation(s)
- Akira Obana
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu City, Shizuoka, Japan.,Department of Medical Spectroscopy, Institute for Medical Photonics Research, Preeminent Medical Photonics Education & Research Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Kibo Ote
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Fumio Hashimoto
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Ryo Asaoka
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu City, Shizuoka, Japan
| | - Yuko Gohto
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu City, Shizuoka, Japan
| | - Shigetoshi Okazaki
- Department of Medical Spectroscopy, Institute for Medical Photonics Research, Preeminent Medical Photonics Education & Research Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Hidenao Yamada
- Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| |
Collapse
|
7
|
Influence of lens opacities and cataract severity on quantitative fundus autofluorescence as a secondary outcome of a randomized clinical trial. Sci Rep 2021; 11:12685. [PMID: 34135449 PMCID: PMC8209039 DOI: 10.1038/s41598-021-92309-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 05/24/2021] [Indexed: 11/21/2022] Open
Abstract
The aim of this study is to investigate the impact of age-related lens opacities and advanced cataract, quantified by LOCS III grading, on quantitative autofluorescence (qAF) measurements in patients before and after cataract surgery. Images from a randomized controlled trial evaluating the impact of femtosecond-laser assisted cataract surgery (FLACS) on retinal thickness were analyzed post-hoc. One-hundred and twenty eyes from 60 consecutive patients with age-related cataract were included and assessed with qAF and optical coherence tomography (OCT) before, 1, 3 and 6 weeks after cataract surgery (randomized 1:1 to FLACS or phacoemulsification). LOCS III grading was performed before surgery. Pre- to post-surgical qAF values, as well as the impact of LOCS III gradings, surgery technique, gender, axial length and age on post-surgery qAF values was investigated using generalized linear mixed models. For this analysis, 106 eyes from 53 patients were usable. No difference in qAF was found between FLACS and phacoemulsification (p > 0.05) and results were pooled for the total cohort. Mean pre-surgical qAF was 89.45 ± 44.9 qAF units, with a significant mean increase of 178.4–191.6% after surgery (p < 0.001). No significant difference was found between the three follow-up visits after surgery (p > 0.05). Higher LOCS III cortical opacity quantifications were associated with a significantly greater increase in qAF after surgery (estimate: 98.56, p = 0.006) and nuclear opacities showed a trend toward an increased change (estimate: 48.8, p = 0.095). Considerable interactions were identified between baseline qAF and cortical opacities, nuclear opacities and posterior subcapsular opacities, as well as nuclear opacities and cortical opacities (p = 0.012, p = 0.064 and p = 0.069, respectively). Quantitative autofluorescence signals are significantly reconstituted after cataract surgery and LOCS III gradings are well associated with post-surgical qAF values. Careful consideration of age-related lens opacities is vital for the correct interpretation of qAF, especially in retinal diseases affecting the elderly. ClinicalTrials.gov Identifier: NCT03465124.
Collapse
|
8
|
Obana A, Gohto Y, Asaoka R. Macular pigment changes after cataract surgery with yellow-tinted intraocular lens implantation. PLoS One 2021; 16:e0248506. [PMID: 33764992 PMCID: PMC7993776 DOI: 10.1371/journal.pone.0248506] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 02/26/2021] [Indexed: 11/21/2022] Open
Abstract
Purpose We previously reported that macular pigment optical density (MPOD) levels decreased during a long follow-up period after clear intraocular lens (IOL) implant surgery presumably due to excessive light exposure. We examined changes in MPOD levels in the eyes that received yellow-tinted IOL implant surgery. Subjects and methods This was a prospective, observational study. Fifty-five eyes of 35 patients were studied. MPOD levels were measured with a dual-wavelength autofluorescence technique on day 4; months 1, 3, and 6; and years 1 and 2 postoperatively. The average optical densities at 0°- 2° eccentricities (local MPODs) and total volumes of MPOD (MPOVs) in the area within 1.5° and 9° eccentricities were analyzed. Results The mean local MPOD at baseline (on day 4) was 0.79 at 0°, 0.71 at 0.5°, 0.68 at 0.9°, and 0.32 at 2°. The mean MPOV within 1.5° and 9° at baseline was 2950 and 18,897, respectively. Local MPOD at 0.9° and 2° and MPOVs were slightly decreased at month 1 and increased after that. The increase reached statistical significance in local MPOD at 0.5° and 2° and MPOVs (Tukey–Kramer test). The changes in MPOV within 9° at year 2 [(MPOV on year 2 − MPOV on day 4) / MPOV on day 4] were from −0.21 to 1.18 (mean and standard deviation: 1.14 ± 0.28). The MPOV of 15 eyes increased more than 10% from the initial value, was maintained within 10% in 21 eyes, and deteriorated more than 10% in only 3 eyes. Conclusions Local MPOD and MPOV tended to slightly decrease month 1 postoperatively and gradually increased after that, but the rates of increases in MPOD levels were small. Yellow-tinted IOLs that have a lower transmittance of blue light might be preferable for preserving MPOD levels after surgery.
Collapse
Affiliation(s)
- Akira Obana
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan.,Photochemical Medicine Department, Photon Medical Research Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Yuko Gohto
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan
| | - Ryo Asaoka
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan
| |
Collapse
|
9
|
Loskutova E, Butler JS, Hernandez Martinez G, Flitcroft I, Loughman J. Macular Pigment Optical Density Fluctuation as a Function of Pupillary Mydriasis: Methodological Considerations for Dual-Wavelength Autofluorescence. Curr Eye Res 2020; 46:532-538. [PMID: 32842779 DOI: 10.1080/02713683.2020.1815792] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE OF THE STUDY Macular pigment (MP), comprising the dietary carotenoids lutein, zeaxanthin and meso-zeaxanthin, is believed to benefit eye health and vision. Numerous clinical and research devices and techniques are currently available to facilitate MP optical density (MPOD) measurement. One of those techniques, dual-wavelength fundus autofluorescence (AF) is being increasingly used for measurement of MP in the eye. There is substantial methodological variation across the published studies that have employed this technique, including in relation to the use of mydriasis, the possible influence of which does not appear to have been addressed in the literature. This prospective cross-sectional study was designed to investigate the effect of mydriasis on MP measurement quality and MPOD values obtained with dual-wavelength AF using the Heidelberg Spectralis HRA+OCT device. MATERIALS AND METHODS Twenty-one healthy participants were recruited to the study. The mean age of participants was 44.8 years (± 14.63). Pupil size and MPOD were measured in one eye for each participant, initially under natural pupil conditions and subsequently 30 minutes following instillation of one drop of 0.5% tropicamide. RESULTS Despite providing MPOD measurements for the majority of undilated eyes (85.7% of eyes herein), pupillary dilation resulted in statistically significant changes in MPOD (p < .001 for central eccentricities). Our results indicate that the changes in MPOD were not uniform across the spatial profile. Marked improvements were also observed in image quality post-dilation (p < .002 for central eccentricities). CONCLUSIONS This study clearly demonstrates that dual-wavelength AF measurements of MPOD in the same eye vary as a function of pupillary dilation status, with MPOD under-estimated across the entire spatial profile of MP for natural relative to dilated pupillary conditions. Mydriasis should, therefore, be used routinely for MPOD measurements using dual wavelength AF, pupil size should be reported and image quality optimized in order to ensure accurate MPOD quantification.
Collapse
Affiliation(s)
- Ekaterina Loskutova
- Centre for Eye Research Ireland, School of Physics, Clinical & Optometric Sciences, Technological University Dublin, Dublin, Ireland
| | - John S Butler
- Centre for Eye Research Ireland, School of Mathematical Sciences, Technological University Dublin, Dublin, Ireland
| | - Gabriela Hernandez Martinez
- Centre for Eye Research Ireland, School of Physics, Clinical & Optometric Sciences, Technological University Dublin, Dublin, Ireland
| | - Ian Flitcroft
- Centre for Eye Research Ireland, School of Physics, Clinical & Optometric Sciences, Technological University Dublin, Dublin, Ireland.,Department of Ophthalmology, Children's University Hospital, Dublin, Ireland
| | - James Loughman
- Centre for Eye Research Ireland, School of Physics, Clinical & Optometric Sciences, Technological University Dublin, Dublin, Ireland
| |
Collapse
|
10
|
Obana A, Gohto Y, Sasano H, Gellermann W, Sharifzadeh M, Seto T, Bernstein PS. Spatial distribution of macular pigment estimated by autofluorescence imaging in elderly Japanese individuals. Jpn J Ophthalmol 2020; 64:160-170. [PMID: 31989400 DOI: 10.1007/s10384-020-00716-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Accepted: 10/31/2019] [Indexed: 11/28/2022]
Abstract
PURPOSE To determine the spatial distribution types of macular pigment (MP) in elderly Japanese individuals and to consider their origin. STUDY DESIGN Observational case series. METHODS Local MP optical density (MPOD) at some eccentricities and MP volume were measured using the MPOD module of a MultiColor Spectralis in 96 pseudophakic eyes of 96 participants (age range, 52-86 years; mean age, 72.8 ± 8.3 years). The MP distribution types were determined from the MP spatial profiles. The retinal thickness (RT) at the foveal center, at both 0.5° and 0.9° eccentricities, and the foveal width were measured using optical coherence tomography. RESULTS The mean local MPOD at the foveal center was 0.79. Spatial distribution was classified into four types: central peak (24.0%), ring-like (40.6%), intermediate (22.9%), and central dip (12.5%). The ring-like type was the most frequent in these Japanese participants. The central-peak type showed lower MPOD than did the other types in the area outside 0.9°. The ring-like type occurred frequently in eyes with small RT at 0.5° and wider foveal width. A rough contour of the Müller cell cone was found more frequently in the central-dip type than in the other types. CONCLUSIONS The present characteristics of the different distribution patterns could be explained by the hypothesis that MP presents mainly in the Müller cell cone within 0.5° and in Müller cells in the outer and inner plexiform layers in the area outside 0.5°. The anatomic characteristics of Müller cells at the fovea and parafovea likely affect the MP distribution.
Collapse
Affiliation(s)
- Akira Obana
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-ku, Hamamatsu, Shizuoka, 430-8558, Japan. .,Hamamatsu BioPhotonics Innovation Chair, Institute for Medical Photonics Research, Preeminent Medical Photonics Education and Research Center, Hamamatsu University School of Medicine, Hamamatsu, Japan.
| | - Yuko Gohto
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-ku, Hamamatsu, Shizuoka, 430-8558, Japan
| | - Hiroyuki Sasano
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-ku, Hamamatsu, Shizuoka, 430-8558, Japan
| | | | | | - Takahiko Seto
- Department of Ophthalmology, Seirei Hamamatsu General Hospital, 2-12-12 Sumiyoshi, Naka-ku, Hamamatsu, Shizuoka, 430-8558, Japan
| | - Paul S Bernstein
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, Salt Lake City, USA
| |
Collapse
|
11
|
Green-Gomez M, Bernstein PS, Curcio CA, Moran R, Roche W, Nolan JM. Standardizing the Assessment of Macular Pigment Using a Dual-Wavelength Autofluorescence Technique. Transl Vis Sci Technol 2019; 8:41. [PMID: 31867142 PMCID: PMC6922273 DOI: 10.1167/tvst.8.6.41] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 10/03/2019] [Indexed: 12/24/2022] Open
Abstract
PURPOSE It is essential to have an appropriate measure to assess macular pigment (MP) that can provide an accurate, valid, and reliable representation of the MP within the macula. The aim of this study was to describe and introduce MP optical volume (MPOV) as an optimal value for reporting MP. METHODS Three hundred ninety-three subjects were analyzed using the Heidelberg Spectralis with the investigational MP optical density (MPOD) module to measure MPOV and MPOD at four foveal eccentricities (0.23°, 0.51°, 0.98°, 1.76° [7° as reference point]). Lutein (L) and zeaxanthin (Z) dietary intake and serum concentrations were evaluated. RESULTS MPOV mean was 5094 (95%CI, 4877-5310); range: 527 to 10,652. MPOV was inversely correlated with body mass index and positively correlated with education (r = -0.156, P = 0.002 and r = 0.124, P = 0.014, respectively). Serum concentrations of L and Z were positively correlated with MPOV (r = 0.422, P < 0.001 and r = 0.285, P < 0.001, respectively). MPOV was positively correlated to MPOD at all measured eccentricities, with the strongest agreement at 1.76° (r = 0.906, P < 0.001). Serum concentrations of L and Z, BMI, education, and age (P < 0.001) were found to be significant predictors of MPOV. CONCLUSIONS The Spectralis MPOV measurement provided a comprehensive and detailed evaluation of the MP profile. The Spectralis MPOV should be considered a preferred metric for the assessment of MP. TRANSLATIONAL RELEVANCE Applying a standardized method for the assessment and report of MP will allow to fully derive meaning from observational studies and to successfully implement this MP measurement technique in research and clinical settings.
Collapse
Affiliation(s)
- Marina Green-Gomez
- Nutrition Research Centre Ireland, School of Health Science, Carriganore House, Waterford Institute of Technology, West Campus, Waterford, Ireland
| | | | - Christine A. Curcio
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Rachel Moran
- Nutrition Research Centre Ireland, School of Health Science, Carriganore House, Waterford Institute of Technology, West Campus, Waterford, Ireland
| | - Warren Roche
- Nutrition Research Centre Ireland, School of Health Science, Carriganore House, Waterford Institute of Technology, West Campus, Waterford, Ireland
| | - John M. Nolan
- Nutrition Research Centre Ireland, School of Health Science, Carriganore House, Waterford Institute of Technology, West Campus, Waterford, Ireland
| |
Collapse
|
12
|
Abstract
Retinal carotenoids are dietary nutrients that uniquely protect the eye from light damage and various retinal pathologies. Their antioxidative properties protect the eye from many retinal diseases, such as age-related macular degeneration. As many retinal diseases are accompanied by low carotenoid levels, accurate noninvasive assessment of carotenoid status can help ophthalmologists identify the patients most likely to benefit from carotenoid supplementation. This review focuses on the different methods available to assess carotenoid status and highlights disease-related changes and potential nutritional interventions.
Collapse
Affiliation(s)
- Lydia Sauer
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah 84132, USA;, ,
| | - Binxing Li
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah 84132, USA;, ,
| | - Paul S. Bernstein
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah 84132, USA;, ,
| |
Collapse
|
13
|
Wang Y, Tran T, Firl K, Huang N, Yasin O, van Kuijk FJ, Montezuma SR. Quantitative fundus autofluorescence in smokers compared to non-smokers. Exp Eye Res 2019; 184:48-55. [DOI: 10.1016/j.exer.2019.04.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 03/19/2019] [Accepted: 04/04/2019] [Indexed: 01/29/2023]
|
14
|
Abstract
Carotenoids are anti-oxidative agents. Human skin and eyes contain specific carotenoid species known to prevent various pathologies caused by oxidative stress. We quantified skin and eye carotenoid levels and investigated their potential correlation in a population including 985 Japanese patients and staff members of an ophthalmology clinic (577 men, 408 women, mean age of 69.7 ± 13.6 [SD]). Skin carotenoid (SC) and macular pigment (MP) levels were measured with reflection spectroscopy and autofluorescence imaging methods, respectively. The mean SC index was 343.1 ± 142.1 (SD). SC indices for women were higher than for men (382 vs 315, p < 0.001). Smokers and overweight subjects (BMI ≥ 25) had lower SC indices. Subjects taking lutein supplements had higher SC indices than non-supplementing subjects (415 vs 325, p < 0.001). SC and MP indices were significantly correlated. The obtained data set can be used for reference purposes by Japanese subjects and researchers interested in tissue responses to diets high in carotenoids and lutein supplementation.
Collapse
|