Tan RKY, Panda SK, Braeu FA, Muralidharan AR, Nongpiur ME, Chan ASY, Aung T, Najjar RP, Girard MJA. The Structural Layers of the Porcine Iris Exhibit Inherently Different Biomechanical Properties. Invest Ophthalmol Vis Sci 2023; 64:11. [PMID: 37796489 PMCID: PMC10561784 DOI: 10.1167/iovs.64.13.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 08/09/2023] [Indexed: 10/06/2023] Open
Abstract
Purpose The purpose of this study was to isolate the structural components of the ex vivo porcine iris tissue and to determine their biomechanical properties. Methods The porcine stroma and dilator tissues were separated, and their dimensions were assessed using optical coherence tomography (OCT). The stroma underwent flow test (n = 32) to evaluate for permeability using Darcy's Law (ΔP = 2000 Pa, A = 0.0391 mm2), and both tissues underwent stress relaxation experiments (ε = 0.5 with initial ramp of δε = 0.1) to evaluate for their viscoelastic behaviours (n = 28). Viscoelasticity was characterized by the parameters β (half width of the Gaussian distribution), τm (mean relaxation time constant), E0 (instantaneous modulus), and E∞ (equilibrium modulus). Results For the stroma, the hydraulic permeability was 9.49 ± 3.05 × 10-6 mm2/Pa · s, and the viscoelastic parameters were β = 2.50 ± 1.40, and τm = 7.43 ± 4.96 s, with the 2 moduli calculated to be E0 = 14.14 ± 6.44 kPa and E∞ = 6.08 ± 2.74 kPa. For the dilator tissue, the viscoelastic parameters were β = 2.06 ± 1.33 and τm = 1.28 ± 1.27 seconds, with the 2 moduli calculated to be E0 = 9.16 ± 3.03 kPa and E∞ = 5.54 ± 1.98 kPa. Conclusions We have established a new protocol to evaluate the biomechanical properties of the structural layers of the iris. Overall, the stroma was permeable and exhibited smaller moduli than those of the dilator muscle. An improved characterization of iris biomechanics may form the basis to further our understanding of angle closure glaucoma.
Collapse
Affiliation(s)
- Royston K. Y. Tan
- Ophthalmic Engineering & Innovation Laboratory, Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
| | - Satish K. Panda
- Ophthalmic Engineering & Innovation Laboratory, Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Department of Mechanical Engineering, Indian Institute of Technology, Bhubaneswar, India
| | - Fabian A. Braeu
- Ophthalmic Engineering & Innovation Laboratory, Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
- Critical Analytics for Manufacturing Personalized-Medicine, Singapore-MIT Alliance for Research and Technology, Singapore
| | - Arumugam R. Muralidharan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
| | - Monisha E. Nongpiur
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
| | - Anita S. Y. Chan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
| | - Tin Aung
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore and National University Health System, Singapore
| | - Raymond P. Najjar
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore and National University Health System, Singapore
- Centre for Innovation & Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Michaël J. A. Girard
- Ophthalmic Engineering & Innovation Laboratory, Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Singapore
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
- Department of Biomedical Engineering, NUS College of Design and Engineering, National University of Singapore, Singapore
| |
Collapse
|
2
|
Li Z, Guo R, Hu X, Yang X, Wen Z, Lin Y, Zhang H. Comparison of cataract patients with regular corneal astigmatism after implantation of extended range-of-vision and bifocal toric intraocular lenses. Front Med (Lausanne) 2023; 10:1105876. [PMID: 37849485 PMCID: PMC10577169 DOI: 10.3389/fmed.2023.1105876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 04/07/2023] [Indexed: 10/19/2023] Open
Abstract
Purpose To compare the postoperative visual acuity and visual quality between extended range-of-vision and multifocal toric intraocular lens (IOLs) after implantation in cataract patients with regular corneal astigmatism. Setting Department of Ophthalmology, the Second Hospital of Jilin University, Changchun, Jilin Province, China. Design Retrospective and single-center study. Methods The study involved implanting the Tecnis Symphony (ZXR00IOL) or the bifocal toric (ZMTIOL) in patients undergoing cataract surgery. Three months after surgery, lens performance was evaluated using distance, intermediate, and near visual acuity tests, defocus curves, the modulation transfer function (MTF), a visual function index questionnaire (VF-14), and the adverse optical interference phenomena. Results The 3-month postoperative follow-up found that both groups had good corrected distance vision. The ZMT group had better-uncorrected distance visual acuity and near visual acuity (p < 0.05). However, the ZXR group showed better uncorrected intermediate visual acuity (p < 0.05) and visual continuity. Overall astigmatism in the postoperative ZMT group was significantly lower than that in the pre-operative group (p < 0.05). The ZMT group had lower total high-order aberrations (tHOs), higher MTF values, and higher VF-14 scores (p < 0.05). Finally, the ZXR group exhibited reduced halo and glare phenomena (p < 0.05). Conclusion We found that ZMT can effectively correct a corneal astigmatism of 1.0-1.5 D and ZXR can improve patient outcomes regarding subjective optical quality and range of vision. These findings have the potential to improve future astigmatism treatment options.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Hui Zhang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin, China
| |
Collapse
|
3
|
Huang Y, Li M, Shen Y, Liu F, Fang Y, Xu H, Zhou X. Study of the Immediate Effects of Autostereoscopic 3D Visual Training on the Accommodative Functions of Myopes. Invest Ophthalmol Vis Sci 2022; 63:9. [PMID: 35113140 PMCID: PMC8819359 DOI: 10.1167/iovs.63.2.9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Purpose Stereoscopic viewing has an impact on ocular dynamics, but its effects on accommodative functions are not fully understood, especially for autostereoscopic viewing. This study aimed to investigate the changes in dynamic accommodative response, accommodative amplitude, and accommodative facility of myopes after autostereoscopic visual training. Methods We enrolled 46 adults (men = 22 and women = 24; age = 21.5 ± 2.5 [range = 18–25] years, spherical equivalent: −4.52 ± 1.89 [−8.88 to −1.75] diopters [D]) who visited the Eye & ENT Hospital of Fudan University. The study population was randomly divided into three-dimensional (3D) and two-dimensional (2D) viewing groups to watch an 11-minute training video displayed in 3D or 2D mode. Dynamic accommodative response, accommodative facility, and accommodative amplitude were measured before, during, and immediately after the training. Accommodative lag and the variability of accommodation were also analyzed. Visual fatigue was evaluated subjectively using a questionnaire. Results Accommodative lag decreased from 0.54 ± 0.29 D to 0.42 ± 0.32 D (P = 0.004), whereas accommodative facility increased from 10.83 ± 4.55 cycles per minute (cpm) to 13.15 ± 5.25 cpm (P < 0.001) in the 3D group. In the 2D group, there was no significant change in the accommodative lag (P = 0.163) or facility (P = 0.975), but a decrease in accommodative amplitude was observed (from 13.88 ± 3.17 D to 12.71 ± 2.23 D, P = 0.013). In the 3D group, the accommodative response changed with the simulated target distance. Visual fatigue was relatively mild in both groups. Conclusions The immediate impact of autostereoscopic training included a decrease in the accommodative lag and an increase in the accommodative facility. However, the long-term effects of autostereoscopic training require further exploration.
Collapse
Affiliation(s)
- Yangyi Huang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Meiyan Li
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Fang Liu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yong Fang
- Shanghai EVIS Technology Co. Ltd., Shanghai, China
| | - Haipeng Xu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|