1
|
Downs JC. Continuous Wireless Telemetric Measurement of Intraocular Pressure (IOP), Ocular Perfusion Pressure (OPP), and Cerebrospinal Fluid Pressure (CSFP) in Nonhuman Primates (NHPs). Methods Mol Biol 2025; 2858:265-289. [PMID: 39433682 DOI: 10.1007/978-1-0716-4140-8_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2024]
Abstract
Intraocular pressure (IOP) and cerebrospinal fluid pressure (CSFP) telemetry in large animal models can be used to determine the exact IOP, CSFP, translaminar pressure, and translaminar pressure gradient exposure that each normal and treated eye is subjected to relative to its fellow eye. In this way, it is possible to determine the independent contributions of each of these parameters (mean and/or transient fluctuations) to the risk of both the onset and rate of progression of glaucoma. Importantly, we have shown that IOP and CSFP fluctuate continuously by up to 100% over the course of the day, so snapshot cage-side IOP measurements are unable to adequately capture the pressure in the eye; CSFP is not measurable noninvasively at all. Implementation of IOP and CSFP telemetry will allow us to precisely determine the pressure insult in each eye of each animal and thereby unravel the true mechanisms underlying pressure-induced damage to the retinal ganglion cells in glaucoma.
Collapse
Affiliation(s)
- J Crawford Downs
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA.
| |
Collapse
|
2
|
Beach KM, Hung LF, Lou L, Ostrin LA. Diurnal Variation and Effects of Dilation and Sedation on Intraocular Pressure in Infant Rhesus Monkeys. Curr Eye Res 2023; 48:289-296. [PMID: 36357337 PMCID: PMC10006333 DOI: 10.1080/02713683.2022.2141782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Accepted: 10/26/2022] [Indexed: 11/12/2022]
Abstract
PURPOSE Intraocular pressure (IOP) is an important factor in numerous ocular conditions and research areas, including eye growth and myopia. In infant monkeys, IOP is typically measured under anesthesia. This study aimed to establish a method for awake IOP measurement in infant rhesus monkeys, determine diurnal variation, and assess the effects of dilation and sedation. METHODS Awake IOP (iCare TonoVet) was measured every 2 h from 7:30 am to 5:30 pm to assess potential diurnal variations in infant rhesus monkeys (age 3 weeks, n = 11). The following day, and every 2 weeks to age 15 weeks, IOP was measured under three conditions: (1) awake, (2) awake and dilated (tropicamide 0.5%), and (3) sedated (ketamine and acepromazine) and dilated. Intraclass correlation coefficient (ICC) was used to determine intersession repeatability, and repeated measures. ANOVA was used to determine effects of age and condition. RESULTS At age 3 weeks, mean (±SEM) awake IOP was 15.4 ± 0.6 and 15.2 ± 0.7 mmHg for right and left eyes, respectively (p=.59). The ICC between sessions was 0.63[-0.5 to 0.9], with a mean difference of 2.2 ± 0.3 mmHg. Diurnal IOP from 7:30 am to 5:30 pm showed no significant variation (p=.65). From 3 to 15 weeks of age, there was a significant effect of age (p=.01) and condition (p<.001). Across ages, IOP was 17.8 ± 0.7 mmHg while awake and undilated, 18.4 ± 0.2 mmHg awake and dilated, and 11.0 ± 0.3 mmHg after sedation and dilation. CONCLUSIONS Awake IOP measurement was feasible in young rhesus monkeys. No significant diurnal variations in IOP were observed between 7:30 am and 5:30 pm at age 3 weeks. In awake monkeys, IOP was slightly higher after mydriasis and considerably lower after sedation. Findings show that IOP under ketamine/acepromazine anesthesia is significantly different than awake IOP in young rhesus monkeys.
Collapse
Affiliation(s)
- Krista M Beach
- University of Houston College of Optometry, Houston, TX, United States
| | - Li-Fang Hung
- University of Houston College of Optometry, Houston, TX, United States
| | - Linjiang Lou
- University of Houston College of Optometry, Houston, TX, United States
| | - Lisa A Ostrin
- University of Houston College of Optometry, Houston, TX, United States
| |
Collapse
|
3
|
Markert JE, Turner DC, Jasien JV, Nyankerh CNA, Samuels BC, Downs JC. Ocular Pulse Amplitude Correlates With Ocular Rigidity at Native IOP Despite the Variability in Intraocular Pulse Volume With Each Heartbeat. Transl Vis Sci Technol 2022; 11:6. [PMID: 36074454 PMCID: PMC9469039 DOI: 10.1167/tvst.11.9.6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to assess ocular coat mechanical behavior using controlled ocular microvolumetric injections (MVI) of 15 µL of balanced salt solution (BSS) infused over 1 second into the anterior chamber (AC) via a syringe pump. Methods Intraocular pressure (IOP) was continuously recorded at 200 Hz with a validated implantable IOP telemetry system in 7 eyes of 7 male rhesus macaques (nonhuman primates [NHPs]) during 5 MVIs in a series at native (3 trials), 15 and 20 mm Hg baseline IOPs, repeated in 2 to 5 sessions at least 2 weeks apart. Ocular rigidity coefficients (K) and ocular pulse volume (PV) were calculated for each trial. Data were averaged across sessions within eyes; PV was analyzed with a three-level nested ANOVA, and parameter relationships were analyzed with Pearson Correlation and linear regression. Results After MVI at native baseline IOP of 10.4 ± 1.6 mm Hg, IOP increased by 9.1 ± 2.8 mm Hg (∆IOP) at a 9.6 ± 2.7 mm Hg/s slope, ocular pulse amplitude (OPA) was 0.70 ± 0.13 mm Hg on average; the average K was 0.042 ± 0.010 µL-1 and average PV was 1.16 ± 0.43 µL. PV varied significantly between trials, days, and eyes (P ≤ 0.05). OPA was significantly correlated with K at native IOP: Pearson coefficients ranged from 0.71 to 0.83 (P ≤ 0.05) and R2 ranged from 0.50 to 0.69 (P ≤ 0.05) during the first trial. Conclusions The MVI-driven ∆IOP and slope can be used to assess ocular coat mechanical behavior and measure ocular rigidity. Translational Relevance Importantly, OPA at native IOP is correlated with ocular rigidity despite the significant variability in PV between heartbeats.
Collapse
Affiliation(s)
- John E Markert
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Daniel C Turner
- Vision Science Graduate Program, School of Optometry, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Jessica V Jasien
- Vision Science Graduate Program, School of Optometry, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Cyril N A Nyankerh
- Vision Science Graduate Program, School of Optometry, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Brian C Samuels
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA
| | - J Crawford Downs
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
4
|
Machiele R, Frankfort BJ, Killer HE, Fleischman D. Problems in CSF and Ophthalmic Disease Research. FRONTIERS IN OPHTHALMOLOGY 2022; 2:896680. [PMID: 38983539 PMCID: PMC11182282 DOI: 10.3389/fopht.2022.896680] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 05/30/2022] [Indexed: 07/11/2024]
Abstract
There has been significant interest and progress in the understanding of cerebrospinal fluid pressure and its relationship to glaucoma and other ophthalmic diseases. However, just as every physiologic fluid pressure fluctuates, cerebrospinal fluid pressure (CSFP) is similarly dynamic. Coupling this with the difficulty in measuring the pressure, there are many obstacles in furthering this field of study. This review highlights some of the difficulties in CSFP research, including fluid compartmentalization, estimation equations, and pressure fluctuation. Keeping these limitations in mind will hopefully improve the quality and context of this burgeoning field.
Collapse
Affiliation(s)
- Ryan Machiele
- Department of Ophthalmology, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States
| | | | - Hanspeter Esriel Killer
- Department of Ophthalmology, Kantonsspital Aarau, Aarau, Switzerland
- Center for Biomedicine University of Basel, Basel, Switzerland
| | - David Fleischman
- Department of Ophthalmology, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States
| |
Collapse
|
5
|
Kedar S, Tong J, Bader J, Havens S, Fan S, Thorell W, Nelson C, Gu L, High R, Gulati V, Ghate D. Effects of Acute Intracranial Pressure Changes on Optic Nerve Head Morphology in Humans and Pig Model. Curr Eye Res 2021; 47:304-311. [PMID: 34894934 DOI: 10.1080/02713683.2021.1952604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
PURPOSE The lamina cribrosa (LC) is a layer of fenestrated connective tissue tethered to the posterior sclera across the scleral canal in the optic nerve head (ONH). It is located at the interface of intracranial and intraocular compartments and is exposed to intraocular pressure (IOP) anteriorly and intracranial pressure (ICP) or Cerebrospinal fluid (CSF) pressure (CSFP) posteriorly. We hypothesize that the pressure difference across LC will determine LC position and meridional diameter of scleral canal (also called Bruch's membrane opening diameter; BMOD). METHODS We enrolled 19 human subjects undergoing a medically necessary lumbar puncture (LP) to lower CSFP and 6 anesthetized pigs, whose ICP was increased in 5 mm Hg increments using a lumbar catheter. We imaged ONH using optical coherence tomography and measured IOP and CSFP/ICP at baseline and after each intervention. Radial tomographic ONH scans were analyzed by two independent graders using ImageJ, an open-source software. The following ONH morphological parameters were obtained: BMOD, anterior LC depth and retinal thickness. We modeled effects of acute CSFP/ICP changes on ONH morphological parameters using ANOVA (human study) and generalized linear model (pig study). RESULTS For 19 human subjects, CSFP ranged from 5 to 42 mm Hg before LP and 2 to 19.4 mm Hg after LP. For the six pigs, baseline ICP ranged from 1.5 to 9 mm Hg and maximum stable ICP ranged from 18 to 40 mm Hg. Our models showed that acute CSFP/ICP changes had no significant effect on ONH morphological parameters in both humans and pigs. CONCLUSION We conclude that ONH does not show measurable morphological changes in response to acute changes of CSFP/ICP. Proposed mechanisms include compensatory and opposing changes in IOP and CSFP/ICP and nonlinear or nonmonotonic effects of IOP and CSFP/ICP across LC.
Collapse
Affiliation(s)
- Sachin Kedar
- Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA.,Department of Neurological Sciences, University of Nebraska Medical Center, Omaha, NE, USA
| | - Junfei Tong
- Department of Mechanical Engineering, University of Nebraska, Lincoln, NE, USA
| | - John Bader
- Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA
| | - Shane Havens
- Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA
| | - Shan Fan
- Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA
| | - William Thorell
- Department of Neurosurgery, University of Nebraska Medical Center, Omaha, NE, USA
| | - Carl Nelson
- Department of Mechanical Engineering, University of Nebraska, Lincoln, NE, USA
| | - Linxia Gu
- Department of Mechanical Engineering, University of Nebraska, Lincoln, NE, USA.,Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, USA
| | - Robin High
- College of Public Health, University of Nebraska Medical Center, Omaha, NE, USA
| | - Vikas Gulati
- Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA
| | - Deepta Ghate
- Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA
| |
Collapse
|
6
|
Zhu Z, Waxman S, Wang B, Wallace J, Schmitt SE, Tyler-Kabara E, Ishikawa H, Schuman JS, Smith MA, Wollstein G, Sigal IA. Interplay between intraocular and intracranial pressure effects on the optic nerve head in vivo. Exp Eye Res 2021; 213:108809. [PMID: 34736887 DOI: 10.1016/j.exer.2021.108809] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 10/19/2021] [Accepted: 10/25/2021] [Indexed: 12/19/2022]
Abstract
Intracranial pressure (ICP) has been proposed to play an important role in the sensitivity to intraocular pressure (IOP) and susceptibility to glaucoma. However, the in vivo effects of simultaneous, controlled, acute variations in ICP and IOP have not been directly measured. We quantified the deformations of the anterior lamina cribrosa (ALC) and scleral canal at Bruch's membrane opening (BMO) under acute elevation of IOP and/or ICP. Four eyes of three adult monkeys were imaged in vivo with OCT under four pressure conditions: IOP and ICP either at baseline or elevated. The BMO and ALC were reconstructed from manual delineations. From these, we determined canal area at the BMO (BMO area), BMO aspect ratio and planarity, and ALC median depth relative to the BMO plane. To better account for the pressure effects on the imaging, we also measured ALC visibility as a percent of the BMO area. Further, ALC depths were analyzed only in regions where the ALC was visible in all pressure conditions. Bootstrap sampling was used to obtain mean estimates and confidence intervals, which were then used to test for significant effects of IOP and ICP, independently and in interaction. Response to pressure manipulation was highly individualized between eyes, with significant changes detected in a majority of the parameters. Significant interactions between ICP and IOP occurred in all measures, except ALC visibility. On average, ICP elevation expanded BMO area by 0.17 mm2 at baseline IOP, and contracted BMO area by 0.02 mm2 at high IOP. ICP elevation decreased ALC depth by 10 μm at baseline IOP, but increased depth by 7 μm at high IOP. ALC visibility decreased as ICP increased, both at baseline (-10%) and high IOP (-17%). IOP elevation expanded BMO area by 0.04 mm2 at baseline ICP, and contracted BMO area by 0.09 mm2 at high ICP. On average, IOP elevation caused the ALC to displace 3.3 μm anteriorly at baseline ICP, and 22 μm posteriorly at high ICP. ALC visibility improved as IOP increased, both at baseline (5%) and high ICP (8%). In summary, changing IOP or ICP significantly deformed both the scleral canal and the lamina of the monkey ONH, regardless of the other pressure level. There were significant interactions between the effects of IOP and those of ICP on LC depth, BMO area, aspect ratio and planarity. On most eyes, elevating both pressures by the same amount did not cancel out the effects. Altogether our results show that ICP affects sensitivity to IOP, and thus that it can potentially also affect susceptibility to glaucoma.
Collapse
Affiliation(s)
- Ziyi Zhu
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Susannah Waxman
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Bo Wang
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jacob Wallace
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Samantha E Schmitt
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Elizabeth Tyler-Kabara
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA, USA; Department of Neurosurgery, University of Texas-Austin, Austin, TX, USA
| | - Hiroshi Ishikawa
- Department of Ophthalmology, NYU School of Medicine, New York, NY, USA
| | - Joel S Schuman
- Department of Ophthalmology, NYU School of Medicine, New York, NY, USA
| | - Matthew A Smith
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Gadi Wollstein
- Department of Ophthalmology, NYU School of Medicine, New York, NY, USA
| | - Ian A Sigal
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
7
|
Karimi A, Rahmati SM, Grytz RG, Girkin CA, Downs JC. Modeling the biomechanics of the lamina cribrosa microstructure in the human eye. Acta Biomater 2021; 134:357-378. [PMID: 34245889 DOI: 10.1016/j.actbio.2021.07.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 06/25/2021] [Accepted: 07/02/2021] [Indexed: 12/13/2022]
Abstract
Glaucoma is among the leading causes of blindness worldwide that is characterized by irreversible damage to the retinal ganglion cell axons in the lamina cribrosa (LC) region of the optic nerve head (ONH), most often associated with elevated intraocular pressure (IOP). The LC is a porous, connective tissue structure that provides mechanical support to the axons as they exit the eye and the biomechanics of the LC microstructure likely play a crucial role in protecting the axons passing through it. There is a limited knowledge of the IOP-driven biomechanics of the LC microstructure, primarily due to its small size and the difficulty with imaging the LC both in vitro and in vivo. We present finite element (FE) models of three human eye posterior poles that include the LC microstructure and interspersed neural tissues (NT) composed of retinal axons that are constructed directly from segmented, binary images of the LC. These models were used to estimate the stresses and strains in the LC and NT for an acute IOP elevation from 0 to 45 mmHg and compared with identical models except that the LC was represented as a homogenized continuum material with either homogeneous isotropic neo-Hookean properties or heterogeneous properties derived from local connective tissue volume fraction (CTVF) and predominant LC beam orientation. Stresses and strains in the LC and NT microstructure were investigated, and results were compared against those from the models wherein the LC was represented as a homogenized continuum. The regionalized volumetric average stresses and strains showed that the microstructural model yielded similar patterns to our prior approach using an LC continuum representation with mapped LC CTVF/anisotropy, but the microstructural modeling approach allows analysis of the stresses and strains in the LC and NT separately. As expected, the LC beams carried most of the IOP load in the microstructural models but exhibited less strain, while the encapsulated NT exhibited lower stresses and much higher strains. Results also revealed that the continuum models underestimate the maximum strains in the LC beams and NT by a factor of 2-3. Microstructural modeling should provide greater insight into the biomechanical factors driving damage to the axons (NT) and LC connective tissue remodeling that occur in glaucoma. The methods presented are ideal for modeling any structure with a complex microstructure composed of different materials, such as trabecular bone, lung, and tissue engineering scaffolds such as decellularized LC. Matlab code for mesh generation from a segmented image stack of the microstructure is included as Supplemental Material. STATEMENT OF SIGNIFICANCE: Glaucoma is among the leading causes of blindness worldwide that is characterized by axon damage in the lamina cribrosa (LC) region of the eye. We present a new approach for finite element modeling the entire eye-specific 3D LC microstructure and the interspersed neural tissues, incorporated into an eye-specific posterior eye model that provides appropriate boundary and loading conditions. Results are presented for three human donor eyes, showing that prior modeling approaches underestimate the stresses and strains in the laminar microstructure. We constructed models from image stacks of the segmented microstructure (Matlab code included) using an approach that is ideal for modeling any structure with a complex microstructure composed of different materials, such as trabecular bone, lung, and tissue engineering scaffolds.
Collapse
|
8
|
Kim J, Gardiner SK, Ramazzotti A, Karuppanan U, Bruno L, Girkin CA, Downs JC, Fazio MA. Strain by virtual extensometers and video-imaging optical coherence tomography as a repeatable metric for IOP-Induced optic nerve head deformations. Exp Eye Res 2021; 211:108724. [PMID: 34375590 PMCID: PMC8511063 DOI: 10.1016/j.exer.2021.108724] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 07/27/2021] [Accepted: 08/06/2021] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine if in vivo strain response of the Optic Nerve Head (ONH) to IOP elevation visualized using Optical Coherence Tomography (OCT) video imaging and quantified using novel virtual extensometers was able to be provided repeatable measurements of tissue specific deformations. METHODS The ONHs of 5 eyes from 5 non-human primates (NHPs) were imaged by Spectralis OCT. A vertical and a horizontal B-scan of the ONH were continuously recorded for 60 s at 6 Hz (video imaging mode) during IOP elevation from 10 to 30 mmHg. Imaging was repeated over three imaging sessions. The 2D normal strain was computed by template-matching digital image correlation using virtual extensometers. ANOVA F-test (F) was used to compare inter-eye, inter-session, and inter-tissue variability for the prelaminar, Bruch's membrane opening (BMO), lamina cribrosa (LC) and choroidal regions (against variance the error term). F-test of the ratio between inter-eye to inter-session variability was used to test for strain repeatability across imaging sessions (FIS). RESULTS Variability of strain across imaging session (F = 0.7263, p = 0.4855) and scan orientation was not significant (F = 1.053, p = 0.3066). Inter session variability of strain was significantly lower than inter-eye variability (FIS = 22.63, p = 0.0428) and inter-tissue variability (FIS = 99.33 p = 0.00998). After IOP elevation, strain was highest in the choroid (-18.11%, p < 0.001), followed by prelaminar tissue (-11.0%, p < 0.001), LC (-3.79%, p < 0.001), and relative change in BMO diameter (-0.57%, p = 0.704). CONCLUSIONS Virtual extensometers applied to video-OCT were sensitive to the eye-specific and tissue-specific mechanical response of the ONH to IOP and were repeatable across imaging sessions.
Collapse
Affiliation(s)
- Jihee Kim
- Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | | | - Andrea Ramazzotti
- Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Udayakumar Karuppanan
- Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Luigi Bruno
- Department of Mechanical, Energy and Management Engineering, University of Calabria, Rende, CS, Italy
| | - Christopher A Girkin
- Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - J Crawford Downs
- Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Massimo A Fazio
- Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA; Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA; The Viterbi Family Department of Ophthalmology, UC San Diego, La Jolla, CA, USA.
| |
Collapse
|
9
|
Pardon LP, Cheng H, Chettry P, Patel NB. Optic Nerve Head Morphological Changes Over 12 Hours in Seated and Head-Down Tilt Postures. Invest Ophthalmol Vis Sci 2021; 61:21. [PMID: 33186468 PMCID: PMC7671873 DOI: 10.1167/iovs.61.13.21] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Purpose The purpose of this study was to determine changes in optic nerve head (ONH) morphology in seated and 6° head-down tilt (HDT) postures over a 12-hour period. Methods Thirty eyes of 30 healthy human subjects (15 females) were included. Composite radial and circular optical coherence tomography (OCT) scans centered on the ONH, intraocular pressure (IOP), and optic nerve sheath diameter (ONSD) were acquired every two hours from 7 a.m. to 7 p.m. for both seated (n = 30) and HDT (n = 10) sessions. Global minimum rim width (BMO-MRW), total retinal thickness (TRT), retinal nerve fiber layer thickness (RNFLT), and Bruch's membrane opening (BMO) height were quantified. Results BMO-MRW decreased an average of 9.55 ± 8.03 µm (P < 0.01) over 12 hours in a seated position (range, -26.64 to +3.36 µm), and thinning was greater in females (-13.56 vs. -5.55 µm, P = 0.004). Modest decreases in TRT from the BMO to 500 µm (P < 0.04) and RNFLT for the 2.7, 3.5, and 4.2 mm circular scans (P < 0.02) were also observed. BMO-MRW thinning was not related to changes in IOP or ONSD (P = 0.34). In HDT, IOP and ONSD increased, BMO height moved anteriorly, and BMO-MRW thinning did not occur (P > 0.1). Conclusions The neuroretinal rim thins throughout the day in healthy individuals, and this change cannot be explained by changes in IOP or ONSD during the same time period. A HDT posture blunts the neuroretinal rim thinning observed in a seated position, suggesting a role of the translaminar pressure difference.
Collapse
Affiliation(s)
- Laura P Pardon
- University of Houston, College of Optometry, Houston, Texas, United States
| | - Han Cheng
- University of Houston, College of Optometry, Houston, Texas, United States
| | - Pratik Chettry
- University of Houston, College of Optometry, Houston, Texas, United States
| | - Nimesh B Patel
- University of Houston, College of Optometry, Houston, Texas, United States
| |
Collapse
|
10
|
Jasien JV, Samuels BC, Johnston JM, Downs JC. Effect of Body Position on Intraocular Pressure (IOP), Intracranial Pressure (ICP), and Translaminar Pressure (TLP) Via Continuous Wireless Telemetry in Nonhuman Primates (NHPs). Invest Ophthalmol Vis Sci 2021; 61:18. [PMID: 33074300 PMCID: PMC7585393 DOI: 10.1167/iovs.61.12.18] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Purpose Recent retrospective clinical studies and animal experiments have suggested that cerebrospinal fluid pressure (CSFP) is important in glaucoma, acting through the translaminar pressure (TLP = IOP − CSFP), which directly affects the optic nerve head. In this study, IOP and intracranial pressure (ICP; a surrogate of CSFP) were measured at various body positions to quantify the determinants of TLP. Methods We have developed an implantable wireless pressure telemetry system based on a small piezoelectric sensor with low temporal drift. Telemetry transducers were placed in the anterior chamber to measure IOP and in the brain parenchyma at eye height to measure ICP. IOP was calibrated against anterior cannulation manometry, and ICP/CSFP was calibrated against an intraparenchymal Codman ICP Express microsensor. We measured IOP, ICP, and TLP = IOP − ICP continuously at 200 Hz in three male nonhuman primates (NHPs) in three trials; pressures were then averaged for 30 seconds per body position. Relative change of IOP, ICP, and TLP from the supine (baseline) position to the seated, standing, and inverted positions were quantified. Results TLP changed significantly and instantaneously from the supine to seated (+14 mm Hg), supine to standing (+13 mm Hg) and supine to inverted (−12 mm Hg) positions (P < 0.05). There was no significant TLP change for supine to prone. ICP showed greater relative change than IOP. Conclusions TLP change due to body position change is driven more by ICP/CSFP than IOP. IOP, ICP, and TLP variability, coupled with telemetry, should allow us to test the hypotheses that IOP, ICP, or TLP fluctuations contribute independently to glaucoma onset or progression.
Collapse
Affiliation(s)
- Jessica V Jasien
- Vision Science Graduate Program, School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - Brian C Samuels
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - James M Johnston
- Department of Neurosurgery, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| | - J Crawford Downs
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, United States
| |
Collapse
|
11
|
Wilkinson CM, Kung TF, Jickling GC, Colbourne F. A translational perspective on intracranial pressure responses following intracerebral hemorrhage in animal models. BRAIN HEMORRHAGES 2021. [DOI: 10.1016/j.hest.2020.10.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
|
12
|
Jasien JV, Zohner YE, Asif SK, Rhodes LA, Samuels BC, Girkin CA, Morris JS, Downs JC. Comparison of extraocular and intraocular pressure transducers for measurement of transient intraocular pressure fluctuations using continuous wireless telemetry. Sci Rep 2020; 10:20893. [PMID: 33262420 PMCID: PMC7708973 DOI: 10.1038/s41598-020-77880-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 11/11/2020] [Indexed: 11/08/2022] Open
Abstract
The optimal approach for continuous measurement of intraocular pressure (IOP), including pressure transducer location and measurement frequency, is currently unknown. This study assessed the capability of extraocular (EO) and intraocular (IO) pressure transducers, using different IOP sampling rates and duty cycles, to characterize IOP dynamics. Transient IOP fluctuations were measured and quantified in 7 eyes of 4 male rhesus macaques (NHPs) using the Konigsberg EO system (continuous at 500 Hz), 12 eyes of 8 NHPs with the Stellar EO system and 16 eyes of 12 NHPs with the Stellar IO system (both measure at 200 Hz for 15 s of every 150 s period). IOP transducers were calibrated bi-weekly via anterior chamber manometry. Linear mixed effects models assessed the differences in the hourly transient IOP impulse, and transient IOP fluctuation frequency and magnitude between systems and transducer placements (EO versus IO). All systems measured 8000-12,000 and 5000-6500 transient IOP fluctuations per hour > 0.6 mmHg, representing 8-16% and 4-8% of the total IOP energy the eye must withstand during waking and sleeping hours, respectively. Differences between sampling frequency/duty cycle and transducer placement were statistically significant (p < 0.05) but the effect sizes were small and clinically insignificant. IOP dynamics can be accurately captured by sampling IOP at 200 Hz on a 10% duty cycle using either IO or EO transducers.
Collapse
Affiliation(s)
- Jessica V Jasien
- Vision Science Graduate Program, School of Optometry, University of Alabama at Birmingham, Birmingham, USA
| | | | - Sonia Kuhn Asif
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, VH 390B | 1670 University Blvd., Birmingham, AL, 35294, USA
| | - Lindsay A Rhodes
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, VH 390B | 1670 University Blvd., Birmingham, AL, 35294, USA
| | - Brian C Samuels
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, VH 390B | 1670 University Blvd., Birmingham, AL, 35294, USA
| | - Christopher A Girkin
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, VH 390B | 1670 University Blvd., Birmingham, AL, 35294, USA
| | - Jeffrey S Morris
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - J Crawford Downs
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, VH 390B | 1670 University Blvd., Birmingham, AL, 35294, USA.
| |
Collapse
|
13
|
Jasien JV, Fazio MA, Samuels BC, Johnston JM, Downs JC. Quantification of Translaminar Pressure Gradient (TLPG) With Continuous Wireless Telemetry in Nonhuman Primates (NHPs). Transl Vis Sci Technol 2020; 9:18. [PMID: 33240571 PMCID: PMC7671865 DOI: 10.1167/tvst.9.12.18] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 10/10/2020] [Indexed: 12/21/2022] Open
Abstract
Purpose Recent retrospective clinical and animal studies suggest that cerebrospinal fluid pressure (CSFP) is important in glaucoma pathogenesis. Intraocular pressure (IOP) and CSFP are the driving components of translaminar pressure (TLP = IOP - CSFP), which acts across the lamina cribrosa (LC) thickness to create the translaminar pressure gradient (TLPG = TLP/LC thickness). Methods We developed an implantable wireless telemetry system based on a small piezoelectric sensor with low temporal drift. IOP, measured in the anterior chamber, and intracranial pressure (ICP), measured in the brain parenchyma (as a surrogate for CSFP) were measured at 200 Hz in three male rhesus macaques (nonhuman primates, NHPs) on a 10% duty cycle (15 seconds of every 150-second period). Three-dimensional LC thickness was autosegmented as the mean thickness of the visible hyperreflective band in 48 radial spectral-domain optical coherence tomography b-scans centered on the optic nerve head. Results Results indicated the rank order of IOP, ICP, TLP, and TLPG for waking, sleeping, and 24-hour periods averaged across all days. NHP 150110 had the highest IOP and ICP in all periods; however, it had the lowest TLPG in all periods due to its relatively thick LC. The other two NHPs showed similar shifts in the rank order of possible glaucoma risk factors. Conclusions IOP is the only modifiable and readily measurable pressure-based risk factor for glaucoma. However, other potential risk factors such as ICP, TLP, and TLPG, as well as their rank-order patterns, differed compared to IOP across subjects, demonstrating that a comprehensive view of relevant risk factors is warranted. Translational Relevance Future studies should consider including CSFP, TLP, and TLPG in addition to IOP as potential risk factors when assessing eye-specific glaucoma susceptibility.
Collapse
Affiliation(s)
- Jessica V Jasien
- Vision Science Graduate Program, School of Optometry, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Massimo A Fazio
- Department of Ophthalmology and Visual Sciences, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - Brian C Samuels
- Department of Ophthalmology and Visual Sciences, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - James M Johnston
- Department of Neurosurgery, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, USA
| | - J Crawford Downs
- Department of Ophthalmology and Visual Sciences, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
14
|
Wilson KI, Godara P, Jasien JV, Zohner E, Morris JS, Girkin CA, Samuels BC, Downs JC. Intra-Subject Variability and Diurnal Cycle of Ocular Perfusion Pressure as Characterized by Continuous Telemetry in Nonhuman Primates. Invest Ophthalmol Vis Sci 2020; 61:7. [PMID: 32492113 PMCID: PMC7415896 DOI: 10.1167/iovs.61.6.7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To characterize ocular perfusion pressure (OPP) fluctuations with continuous telemetry over 24-hour periods across multiple days in nonhuman primates (NHPs) to test the hypotheses that OPP differs among NHPs and that the diurnal cycle of OPP is characterized by low OPP during sleep. Methods We have developed and validated two implantable radiotelemetry systems that allow continuous measurement of intraocular pressure (IOP), arterial blood pressure (BP), and OPP up to 500 Hz. OPP was measured unilaterally in 12 male NHPs for periods of 38 to 412 days. IOP transducers were calibrated directly via anterior chamber manometry, and OPP was calculated continuously as central retinal artery BP minus IOP. OPP data were corrected for signal drift between calibrations and averaged hourly. Results OPP varied widely among animals, with daily averages ranging from ∼47 to 65 mm Hg. In eight of 12 NHPs, OPP was significantly lower during sleep compared to waking hours. In three animals, the diurnal cycle was reversed and OPP was significantly higher during sleep (P < 0.05), and one NHP showed no diurnal cycle. Day-to-day OPP variability within NHPs was the largest source of overall OPP variability, even larger than the differences between NHPs. Average daily OPP showed an unexplained ∼32-day cyclic pattern in most NHPs. Conclusions Average OPP varied widely and exhibited differing diurnal cycles in NHPs, a finding that matches those of prior patient studies and indicates that OPP studies in the NHP model are appropriate. Infrequent snapshot measurements of either IOP or BP are insufficient to capture true IOP, BP, and OPP and their fluctuations.
Collapse
|
15
|
Downs JC. Neural coupling of intracranial pressure and aqueous humour outflow facility: A potential new therapeutic target for intraocular pressure management. J Physiol 2020; 598:1429-1430. [PMID: 32060923 DOI: 10.1113/jp279355] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 02/12/2020] [Indexed: 11/08/2022] Open
Affiliation(s)
- J Crawford Downs
- Department of Ophthalmology and Visual Sciences, School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|