1
|
Phu J, Khuu SK, Nivison-Smith L, Kalloniatis M. Standard automated perimetry for glaucoma and diseases of the retina and visual pathways: current and future perspectives. Prog Retin Eye Res 2024:101307. [PMID: 39413870 DOI: 10.1016/j.preteyeres.2024.101307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 10/11/2024] [Accepted: 10/11/2024] [Indexed: 10/18/2024]
Abstract
Static automated perimetry (SAP) remains a mainstay of functional assessment of the visual field in diseases of the visual pathway, such as glaucoma and age-related macular degeneration. The fundamental psychophysical task of responding to stimuli of different levels of contrast has remained minimally changed since its inception in the 1980s, and this is potentially the root of several unresolved issues involving the technique. Enduring issues include the optimisation of SAP parameters for maximising defect detection, the influence of subjective behaviour on the response, structure-function discordance, and ageing- and disease-related changes of the visual pathway. Addressing these issues has been a focus of our research program and is the subject of this manuscript. We will review some of the basic psychophysical principles and methods that have contributed to the development of SAP and their contributions to its output measurements. Parameters that are interrogated include stimulus size and background luminance and their modification to improve defect defection in glaucoma and age-related macular degeneration. We propose frameworks for optimising testing parameters and leveraging the results for changing clinical care. In our pursuit of optimising the structure-function relationship in the eye, several areas of research have been developed and explored, including: the reconciliation of subjective responses in perimetry; by minimising sources of biases, such as Method of Limits we have been able to equate static and kinetic perimetry outputs in relation to underlying structural loci. This also formed the basis for our clustering framework, which groups together statistically similar structural and functional test locations to maximise structure-function concordance. Throughout the manuscript, we review the scientific underpinnings of clinical measurements, framing application into real-world patients to improve clinical practice.
Collapse
Affiliation(s)
- Jack Phu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia; Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia; Concord Clinical School, Concord Repatriation General Hospital, Concord, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, VIC, Australia.
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia.
| | - Lisa Nivison-Smith
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia.
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia; School of Medicine (Optometry), Deakin University, Waurn Ponds, VIC, Australia; College of Optometry, University of Houston, Houston, TX, USA.
| |
Collapse
|
2
|
Meyerov J, Chen Y, Busija L, Green C, Skalicky SE. Repeatability of Online Circular Contrast Perimetry Compared to Standard Automated Perimetry. J Glaucoma 2024; 33:505-515. [PMID: 38595156 DOI: 10.1097/ijg.0000000000002384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 02/16/2024] [Indexed: 04/11/2024]
Abstract
PRCIS Online circular contrast perimetry provides visual field assessment on any computer or tablet with no extra hardware. It has good test repeatability and reliability that is comparable with standard automated perimetry. It holds promise for use in disease screening and surveillance to expand the provision of glaucoma care. PURPOSE To evaluate the repeatability of online circular contrast perimetry (OCCP) compared to standard automated perimetry (SAP) in normal participants and patients with stable glaucoma over 18 weeks. METHODS Thirty-six participants (13 normal controls and 23 patients with open angle glaucoma) were recruited. OCCP and SAP perimetry tests were performed twice at baseline, then at 6, 12, and 18 weeks. Global perimetric indices were compared between perimetry types and analyzed for short-term and intermediate-term repeatability. RESULTS There were no statistically significant changes over time for both OCCP and SAP across all groups for mean deviation (MD), pattern standard deviation, and visual index/visual field index ( P >0.05). Test-retest intraclass correlation coefficients (ICCs) for OCCP MD were excellent at baseline (0.98, 95% CI: 0.89-0.99) and good at 18 weeks (0.88, 95% CI: 0.51-0.98). SAP test-retest ICCs were excellent at baseline (0.94, 95% CI: 0.70-0.99) and 18 weeks (0.97, 95% CI: 0.84-0.99). Inter-test ICCs were good, ranging from 0.84 to 0.87. OCCP testing time was shorter than SAP (5:29 ± 1:24 vs. 6:00 ± 1:05, P <0.001). OCCP had similar false-positive (3.84 ± 3.32 vs. 3.66 ± 4.53, P =0.48) but lower false-negative (0.73 ± 1.52 vs. 4.48 ± 5.00, P <0.001) and fixation loss responses (0.91 ± 1.32 vs. 2.02 ± 2.17, P <0.001). CONCLUSIONS OCCP allows visual field assessment on any computer screen with no additional hardware. It demonstrated good repeatability and reliability with similar performance indices to SAP in both the short term and intermediate term. OCCP has the potential to be utilized as a glaucoma screening and surveillance tool for in-clinic and at-home testing, expanding the provision of care.
Collapse
Affiliation(s)
- Joshua Meyerov
- Department of Ophthalmology, The Alfred Hospital, Alfred Health
| | - Yang Chen
- Department of Surgery Ophthalmology, University of Melbourne
| | - Lazar Busija
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Catherine Green
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne
- Glaucoma Investigation and Research Unit, The Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
3
|
Gupta V, Kong GXY, Singh A, Panigrahi A, Gupta S, Prea S, Vingrys AJ. Measuring Visual Fields in Children With Glaucoma Using a Portable Tablet. Transl Vis Sci Technol 2024; 13:10. [PMID: 38743410 PMCID: PMC11103736 DOI: 10.1167/tvst.13.5.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 03/19/2024] [Indexed: 05/16/2024] Open
Abstract
Purpose To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.
Collapse
Affiliation(s)
- Viney Gupta
- Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| | - George X. Y. Kong
- Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia
| | - Abhishek Singh
- Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| | - Arnav Panigrahi
- Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| | - Shikha Gupta
- Dr Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, New Delhi, India
| | - Selwyn Prea
- Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia
- Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia
| | - Algis J. Vingrys
- Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
4
|
Chen YX, Meyerov J, Skalicky SE. Online Circular Contrast Perimetry via a Web-Application: Establishing a Normative Database for Central 10-Degree Perimetry. Clin Ophthalmol 2024; 18:201-213. [PMID: 38269363 PMCID: PMC10807269 DOI: 10.2147/opth.s440964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 12/23/2023] [Indexed: 01/26/2024] Open
Abstract
Purpose To establish a normative database using a central 10-degree grid pattern for the online circular contrast perimetry (OCCP) application. Participants Fifty participants with mean age 65 ± 13 years were selected for this study. One eye from each participant that met inclusion criteria was randomly included in the cohort. Methods The web-application delivered online 52-loci perimetry in a central 10-degree pattern using circular flickering targets. These targets consist of concentric sinusoidal alternating contrast rings. Users were guided by the application to the correct viewing distance and head position using in-built blind spot localization and webcam monitoring. A spinning golden star was used as the fixation target and patients performed the test in a darkened room following standard automated perimetry (SAP). Results The reliability rates and global indices for OCCP were similar to SAP. OCCP mean sensitivity reduced with age at a similar rate to SAP. Mean sensitivity per loci of 10-degree OCCP was greater than SAP by 1.24 log units (95% CI 1.23 to 1.26) and obeyed a physiological hill of vision. Small differences existed in mean sensitivities between OCCP and SAP which increased with increasing spot eccentricity. Mean deviation (MD) displayed good agreement between the two tests. Conclusion Central 10-degree online circular contrast perimetry via a computer-based application has comparable perimetric results to standard automated perimetry in a normal cohort.
Collapse
Affiliation(s)
- Yang X Chen
- St Vincent’s Hospital Clinical School, University of Melbourne, Melbourne, VIC, Australia
| | - Joshua Meyerov
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
- Glaucoma Investigation and Research Unit, the Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| |
Collapse
|
5
|
Montesano G, Redmond T, Mulholland PJ, Garway-Heath DF, Ometto G, Romano D, Antonacci F, Tanga L, Carnevale C, Rossetti LM, Crabb DP, Oddone F. Spatial Summation in the Glaucomatous Macula: A Link With Retinal Ganglion Cell Damage. Invest Ophthalmol Vis Sci 2023; 64:36. [PMID: 38010697 PMCID: PMC10683773 DOI: 10.1167/iovs.64.14.36] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 10/03/2023] [Indexed: 11/29/2023] Open
Abstract
Purpose The purpose of this study was to test whether functional loss in the glaucomatous macula is characterized by an enlargement of Ricco's area (RA) through the application of a computational model linking retinal ganglion cell (RGC) damage to perimetric sensitivity. Methods One eye from each of 29 visually healthy subjects <40 years old, 30 patients with glaucoma, and 20 age-similar controls was tested with a 10-2 grid with stimuli of 5 different area sizes. Structural estimates of point-wise RGC density were obtained from optical coherence tomography (OCT) scans. Structural and functional data from the young healthy cohort were used to estimate the parameters of a computational spatial summation model to generate a template. The template was fitted with a Bayesian hierarchical model to estimate the latent RGC density in patients with glaucoma and age-matched controls. We tested two alternative hypotheses: fitting the data by translating the template horizontally (H1: change in RA) or vertically (H2: loss of sensitivity without a change in RA). Root mean squared error (RMSE) of the model fits to perimetric sensitivity were compared. Ninety-five percent confidence intervals were bootstrapped. The dynamic range of the functional and structural RGC density estimates was denoted by their 1st and 99th percentiles. Results The RMSE was 2.09 (95% CI = 1.92-2.26) under H1 and 2.49 (95% CI = 2.24-2.72) under H2 (P < 0.001). The average dynamic range for the structural RGC density estimates was only 11% that of the functional estimates. Conclusions Macular sensitivity loss in glaucoma is better described by a model in which RA changes with RGC loss. Structural measurements have limited dynamic range.
Collapse
Affiliation(s)
- Giovanni Montesano
- City, University of London, Optometry and Visual Sciences, London, United Kingdom
- NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
| | - Tony Redmond
- School of Optometry and Vision Sciences, Cardiff University, Cardiff, United Kingdom
| | - Pádraig J. Mulholland
- NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
- Centre for Optometry and Vision Science, Biomedical Sciences Research Institute, Ulster University, Coleraine, United Kingdom
| | - David F. Garway-Heath
- NIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
| | - Giovanni Ometto
- City, University of London, Optometry and Visual Sciences, London, United Kingdom
| | - Dario Romano
- ASST Santi Paolo e Carlo, Eye Clinic – University of Milan, Milan, Italy
| | - Federica Antonacci
- ASST Santi Paolo e Carlo, Eye Clinic – University of Milan, Milan, Italy
| | | | | | - Luca M. Rossetti
- ASST Santi Paolo e Carlo, Eye Clinic – University of Milan, Milan, Italy
| | - David P. Crabb
- City, University of London, Optometry and Visual Sciences, London, United Kingdom
| | | |
Collapse
|
6
|
Vrijling ACL, de Boer MJ, Renken RJ, Marsman JBC, Grillini A, Petrillo CE, Heutink J, Jansonius NM, Cornelissen FW. Stimulus contrast, pursuit mode, and age strongly influence tracking performance on a continuous visual tracking task. Vision Res 2023; 205:108188. [PMID: 36773370 DOI: 10.1016/j.visres.2023.108188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 01/23/2023] [Accepted: 01/23/2023] [Indexed: 02/12/2023]
Abstract
Human observers tend to naturally track moving stimuli. This tendency may be exploited towards an intuitive means of screening visual function as an impairment induced reduction in stimulus visibility will decrease tracking performance. Yet, to be able to detect subtle impairments, stimulus contrast is critical. If too high, the decrease in performance may remain undetected. Therefore, for this approach to become reliable and sensitive, we need a detailed understanding of how age, stimulus contrast, and the type of stimulus movement affect continuous tracking performance. To do so, we evaluated how well twenty younger and twenty older participants tracked a semi-randomly moving stimulus (Goldmann size III, 0.43 degrees of visual angle), presented at five contrast levels (5%-10%-20%-40%-80%). The stimulus could move smoothly only (smooth pursuit mode) or in alternation with displacements (saccadic pursuit mode). Additionally, we assessed static foveal and peripheral contrast thresholds. For all participants, tracking performance improved with increasing contrast in both pursuit modes. To reach threshold performance levels, older participants required about twice as much contrast (20% vs. 10% and 40% vs. 20% in smooth and saccadic modes respectively). Saccadic pursuit detection thresholds correlated significantly with static peripheral contrast thresholds (rho = 0.64). Smooth pursuit detection thresholds were uncorrelated with static foveal contrast thresholds (rho = 0.29). We conclude that continuous visual stimulus tracking is strongly affected by stimulus contrast, pursuit mode, and age. This provides essential insights that can be applied towards new and intuitive approaches of screening visual function.
Collapse
Affiliation(s)
- A C L Vrijling
- Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands; Royal Dutch Visio, Centre of Expertise for Blind and Partially Sighted People, Huizen, the Netherlands.
| | - M J de Boer
- Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - R J Renken
- Cognitive Neuroscience Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - J B C Marsman
- Cognitive Neuroscience Center, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | | | | | - J Heutink
- Royal Dutch Visio, Centre of Expertise for Blind and Partially Sighted People, Huizen, the Netherlands; Department of Clinical and Developmental Neuropsychology, University of Groningen, Groningen, the Netherlands
| | - N M Jansonius
- Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands; Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - F W Cornelissen
- Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| |
Collapse
|
7
|
Test Reliability and Compliance to a Twelve-Month Visual Field Telemedicine Study in Glaucoma Patients. J Clin Med 2022; 11:jcm11154317. [PMID: 35893408 PMCID: PMC9332101 DOI: 10.3390/jcm11154317] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 02/01/2023] Open
Abstract
Background: Our primary aim is to quantify test reliability and compliance of glaucoma patients to a weekly visual field telemedicine (VFTM) schedule. A secondary aim is to determine concordance of the VFTM results to in-clinic outcomes. Methods: Participants with stable glaucoma in one eye were recruited for a 12 month VFTM trial using the Melbourne Rapid Fields (MRF-home, MRFh) iPad application. Participants attended routine 6 month clinical reviews and were tasked with weekly home monitoring with the MRFh over this period. We determined compliance to weekly VFTM (7 + 1 days) and test reliability (false positives (FPs) and fixation loss (FL) <33%). A secondary aim considered concordance to in-clinic measures of visual field (MRF-clinic (MRFc) and the Humphrey Field Analyzer (HFA)) in active participants (≥10 home examinations and 5 reliable HFA examinations). The linear trend in the MRFh mean deviation (MD) was compared to the HFA guided progression analysis (GPA) using Bland−Altman methods. Data are shown as the mean ± standard deviation. Results: Forty-seven participants with a mean age of 64 ± 14.6 years were recruited for the trial. The VFTM uptake was 85% and compliance to weekly home monitoring was 75% in the presence of weekly text reminders in the analysed group (n = 20). The analysed group was composed of test subjects with five reliable in-clinic HFA examinations (GPA analysis available) and who submitted a minimum of 10 MRFh examinations from home. Of the 757 home examinations returned, approximately two-thirds were reliable, which was significantly lower than the test reliability of the HFA in-clinic (MRFh: 65% vs. HFA: 85%, p < 0.001). The HFA-GPA analysis gave little bias from the MRFh slope (bias: 0.05 dB/yr, p > 0.05). Two eyes were found to have clinical progression during the 12 month period, and both were detected by VFTM. Conclusions: VFTM over 12 months returned good compliance (75%) to weekly testing with good concordance to in-clinic assays. VFTM is a viable option for monitoring patients with glaucoma for visual field progression in between clinical visits.
Collapse
|