Itokawa T, Okajima Y, Iwashita H, Koji K, Tashiro S, Suzuki T, Hori Y. Association between dryness sensation and ocular surface temperature and conjunctival blood flow in soft contact lens wearers. Cont Lens Anterior Eye 2024; 47:102166. [PMID: 38604915 DOI: 10.1016/j.clae.2024.102166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 04/02/2024] [Accepted: 04/04/2024] [Indexed: 04/13/2024]
Abstract
PURPOSE To investigate the association between dryness, ocular surface temperature (OST), and conjunctival blood flow (CBF) in soft contact lens (SCL) wearers after airflow stimulation. METHODS After recruiting 21 SCL wearers (mean age, 25.3 ± 4.2 years), subjects used two different daily disposable silicone hydrogel SCLs (narafilcon A and delefilcon A lenses). On three of four measurement days, excluding the first, OST, CBF, tear meniscus height (TMH), and non-invasive tear break-up time (NIBUT) were measured after airflow stimulation at a rate of 3 m/s for 10 min. The measurements were conducted without SCLs on the first and second days, and with different SCLs on the third and fourth days. Dryness was evaluated using the visual analogue scale (VAS). These parameters were compared between the two types of SCLs, and their association with the dryness sensation was then investigated. RESULTS Dryness was significantly weakly correlated with OST (r = -0.375, p < 0.05) and CBF (r = 0.339, p < 0.05). TMH, NIBUT, and VAS scores for dryness with the delefilcon A lens (0.15 ± 0.05 mm, 3.7 ± 01.7 s and 29.4 ± 16.9) were significantly higher, longer, and lower, respectively, than those with the narafilcon A lens (0.12 ± 0.05 mm, 2.3 ± 1.7 s and 35.9 ± 17.0; p < 0.05, p < 0.01 and p < 0.01). The changes in the OST and CBF between with and without the delefilcon A lens (-0.36 ± 0.35 °C and 0.99 ± 0.19) were significantly small compared to the narafilcon A lens (-0.60 ± 0.42 °C and 1.11 ± 0.21; p < 0.01 for both comparisons). CONCLUSION Dryness was correlated with OST and CBF, which indicates that when dryness was high, OST was low and CBF was high. These results suggest that OST and CBF assessments are effective for evaluating dryness sensation.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan.
| | - Yukinobu Okajima
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan; Tsunashima Eye Clinic, Yokohama, Kanagawa, Japan
| | - Hiroko Iwashita
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| | - Kakisu Koji
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| | - Shigeki Tashiro
- Clinical Research Center, Nagasaki University Hospital, Nagasaki, Japan
| | - Takashi Suzuki
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan; Ishizuchi Eye Clinic, Niihama, Ehime, Japan
| | - Yuichi Hori
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
2
|
Misu N, Mimura T, Noma H, Shinbo K. Patient Satisfaction and Tear Film Break-Up Time After First-Time Wearing of Silicone Hydrogel Contact Lenses. Cureus 2024; 16:e52516. [PMID: 38371096 PMCID: PMC10874256 DOI: 10.7759/cureus.52516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/18/2024] [Indexed: 02/20/2024] Open
Abstract
PURPOSE The dryness and discomfort associated with soft contact lenses (SCLs) prevent their continued use. Recently, verofilcon A, a new daily disposable silicone hydrogel material SCL, was introduced, which has a high water content (surface water content of 80% or more) that overcomes the low water content drawback of silicone hydrogels. In this study, we evaluated the non-invasive tear break-up time (NIBUT) and comfort level in individuals wearing verofilcon A SCL for the first time. METHODS We enrolled 42 first-time SCL wearers, comprising 84 eyes. NIBUT was measured using the DR-1α® dry eye observation device at the state of the naked eye before SCL wear (baseline) and at one and four weeks after the first SCL wear. Additionally, we conducted a questionnaire survey during the fourth week to assess the comfort level (0-10) of SCL wear. Results: The NIBUT values were significantly higher at one week (10.8 ± 2.2 s, p<0.01) and four weeks (11.4 ± 2.2 s, p<0.01) after the first SCL wear than those at baseline (5.9 ± 2.0 s). Comfort level in SCL use was significantly higher at one week (9.0 ± 1.1, p<0.01) and four weeks (8.7 ± 1.2, p<0.01) than that at baseline (7.8 ± 1.8), and this level was higher regardless of the baseline NIBUT value. CONCLUSION Prolonged BUT and increased comfort levels were observed in individuals wearing verofilcon A SCLs. Improvement in tear fluid retention was found to alleviate dry eye and discomfort, suggesting that verofilcon A may be a beneficial introductory lens for first-time SCL wearers.
Collapse
Affiliation(s)
- Naoko Misu
- Ophthalmology, Teikyo University School of Medicine, Tokyo, JPN
| | - Tatsuya Mimura
- Ophthalmology, Teikyo University School of Medicine, Tokyo, JPN
| | - Hidetaka Noma
- Ophthalmology, Hachioji Medical Center, Tokyo Medical University, Hachioji, JPN
| | | |
Collapse
|
3
|
Yokoi N, Furusawa Y, Kato H, Kusada N, Sotozono C, Eftimov P, Georgiev GA. Characteristics of Pre-Lens Tear Film Behavior in Eyes Wearing Delefilcon A Silicone Hydrogel Water Gradient Contact Lenses. Diagnostics (Basel) 2023; 13:3642. [PMID: 38132226 PMCID: PMC10742534 DOI: 10.3390/diagnostics13243642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 11/21/2023] [Accepted: 12/06/2023] [Indexed: 12/23/2023] Open
Abstract
The pre-lens tear film (PLTF) over (i) delefilcon A silicone hydrogel water gradient (WG; 33-80% from core to surface) contact lenses (CLs) (SHWG-CLs) and (ii) subjects' own non-WG soft CLs (SCLs) (SO-SCLs) was studied in 30 eyes of 30 subjects to assess the hypothesized PLTF stabilization over SHWG-CLs. In both eyes, delefilcon A SHWG-CLs (DAILIES TOTAL1®; Alcon, Fort Worth, TX, USA) or SO-SCLs were worn. After 15 min of wearing each lens, the tear meniscus radius (TMR, mm), lipid-layer interference grade (IG) and spread grade (SG), and non-invasive breakup time (NIBUT, seconds) were evaluated and compared between the SHWG-CLs and the SO-SCLs. The comparison between the SHWG-CL and SO-SCL groups (SHWG-CL and SO-SCL, mean ± SD) revealed that TMRs temporarily decreased and reached a plateau value after 15 min (0.21 ± 0.06; 0.21 ± 0.06) compared to the value prior to CL insertion (0.24 ± 0.08; 0.25 ± 0.08), with no significant difference between the two groups. The NIBUT, IG, and SG values after 15 min of wearing the CLs were (9.7 ± 3.7; 4.7 ± 4.2), (1.0 ± 0.2; 1.8 ± 1.0), and (1.1 ± 0.4; 1.9 ± 1.5), respectively, and all values were significantly better in the SHWG-CL group (p < 0.0001, p = 0.0039, and p < 0.0001, respectively). We found that compared to the SO-SCLs, the maintenance of the PLTF on the SHWG-CLs was supported by the thicker and more stable PLTF.
Collapse
Affiliation(s)
- Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Yuki Furusawa
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Hiroaki Kato
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Natsuki Kusada
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Chie Sotozono
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Petar Eftimov
- Department of Cell and Developmental Biology, Faculty of Biology, St. Kliment Ohridski University of Sofia, 1164 Sofia, Bulgaria;
| | - Georgi As. Georgiev
- Department of Optics and Spectroscopy, Faculty of Physics, St. Kliment Ohridski University of Sofia, 1164 Sofia, Bulgaria;
| |
Collapse
|
4
|
Wan K, Mashouf J, Hall B. Comfort After Refitting Symptomatic Habitual Reusable Toric Lens Wearers with a New Daily Disposable Contact Lens for Astigmatism. Clin Ophthalmol 2023; 17:3235-3241. [PMID: 37927572 PMCID: PMC10624181 DOI: 10.2147/opth.s429237] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 09/20/2023] [Indexed: 11/07/2023] Open
Abstract
Purpose To subjectively evaluate comfort with a daily disposable (delefilcon A for astigmatism) contact lens compared to other common weekly/monthly soft toric contact lenses in symptomatic wearers. Methods This open-label, single arm study enrolled current reusable soft toric lens wearers with minimum score of 12 on the contact lens dry eye (CLDEQ-8) questionnaire. Subjects were also administered the CLDEQ-8 after 1 replacement schedule of their optimized habitual toric lenses (2 to 4 weeks), and after 2 weeks of wear with delefilcon A toric daily disposable lenses (Dailies Total1 for Astigmatism; Alcon Vision LLC, Fort Worth, Texas). Results A total of 85 subjects completed the study. Mean total CLDEQ-8 score was 16.8 ± 8.1 for subjects refit with their optimized habitual toric lenses and 12.4 ± 7.5 for subjects refit with delefilcon A toric lenses, a difference of 4.3 ± 10.4 (p < 0.001). With delefilcon A toric lenses, 78.9% of subjects reported little to no intensity of eye discomfort, compared to 51.7% for the habitual toric lenses (p = 0.005). In addition, 77.7% of subjects reported little to no intensity of dryness for delefilcon A toric lenses, compared to 50.6% for the habitual toric lenses (p = 0.001). Conclusion The subjective comfort in symptomatic habitual reusable toric contact lens wearers was improved by refitting with delefilcon A toric lenses.
Collapse
Affiliation(s)
- Keith Wan
- Scripps Optometric Group, San Diego, CA, USA
| | - Jay Mashouf
- Scripps Optometric Group, San Diego, CA, USA
| | | |
Collapse
|
5
|
Capote-Puente R, Sánchez-González JM, Sánchez-González MC, Bautista-Llamas MJ. Evaluation of Celligent® Biomimetic Water Gradient Contact Lens Effects on Ocular Surface and Subjective Symptoms. Diagnostics (Basel) 2023; 13:diagnostics13071258. [PMID: 37046476 PMCID: PMC10093668 DOI: 10.3390/diagnostics13071258] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/20/2023] [Accepted: 03/26/2023] [Indexed: 03/30/2023] Open
Abstract
This study aimed to evaluate the non-invasive and subjective symptoms associated with Lehfilcon A water gradient silicone hydrogel contact lenses with bacterial and lipid resistance technology. A prospective, longitudinal, single-centre, self-controlled study was conducted among silicone hydrogel contact lens wearers. Non-invasive analysis of the pre-lens tear film was performed using the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA), and the meibomian glands were evaluated with the Cobra® HD infrared meibographer. After 30 days of contact lens wear, the subjects were re-evaluated to determine the changes in conjunctival redness, subjective dry eye disease, tear meniscus height, lipid pattern, and non-invasive break-up time. Results showed that the lipid layer thickness decreased significantly from 2.05 ± 1.53 to 0.92 ± 1.09 Guillon patterns, and the tear meniscus height decreased from 0.21 ± 0.04 to 0.14 ± 0.03. The mean pre-lens non-invasive break-up time (NIBUT) significantly increased from 15.19 ± 9.54 to 25.31 ± 15.81 s. The standard Patient Evaluation of Eye Disease (SPEED) score also decreased from 7.39 ± 4.39 to 5.53 ± 4.83. The results suggest that Lehfilcon A significantly reduced lipid and aqueous tear film volume but improved break-up time and subjective dry eye symptoms.
Collapse
Affiliation(s)
- RaĂşl Capote-Puente
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - JosĂ©-MarĂa Sánchez-González
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - MarĂa Carmen Sánchez-González
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| | - MarĂa-JosĂ© Bautista-Llamas
- Optica Area, Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
| |
Collapse
|
6
|
Capote-Puente R, Bautista-Llamas MJ, Sánchez-González JM. Tear Film Dynamics between Low and High Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) Score with a Lehfilcon A Silicone Hydrogel Water Gradient Contact Lens: A Non-Invasive Methodology Approach. Diagnostics (Basel) 2023; 13:diagnostics13050939. [PMID: 36900083 PMCID: PMC10001148 DOI: 10.3390/diagnostics13050939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/16/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023] Open
Abstract
The purpose of this study is to evaluate the tear film dynamics between individuals with low and high Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) scores when wearing Lehfilcon A silicone hydrogel water gradient contact lenses. In this study, we implemented a longitudinal, single-location, self-comparison investigation. Variables measured included conjunctival redness, lipid layer thickness, tear meniscus height, first and mean non-invasive break-up time, CLDEQ-8, and standard patient evaluation of eye dryness (SPEED). In the second phase, participants were re-evaluated after 30 days of wearing the contact lenses to assess the tear film wearing the lenses. In a longitudinal comparison by group, we found that lipid layer thickness decreased 1.52 ± 1.38 (p < 0.01) and 0.70 ± 1.30 (p = 0.01) Guillon patterns degrees in the low and high CLDEQ-8 group, respectively. MNIBUT increased in 11.93 ± 17.93 (p < 0.01) and 7.06 ± 12.07 (p < 0.01) seconds. Finally, LOT increased in 22.19 ± 27.57 (p < 0.01) and 16.87 ± 25.09 (p < 0.01). In conclusion, this study demonstrates the effectiveness of Lehfilcon A silicone hydrogel water gradient contact lenses in improving tear film stability and reducing subjective dry eye symptoms in individuals with low and high CLDEQ-8 scores. However, it also led to an increase in conjunctival redness and a decrease in tear meniscus height.
Collapse
|
7
|
Capote-Puente R, Eftimov P, Bautista-Llamas MJ, Yokoi N, Sánchez-González JM, Georgiev G. Short-term tear film stability, optical quality and visual performance in two dual-focus contact lenses for myopia control with different optical designs. Ophthalmic Physiol Opt 2023; 43:290-291. [PMID: 36427053 DOI: 10.1111/opo.13076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 11/16/2022] [Accepted: 11/17/2022] [Indexed: 11/27/2022]
Affiliation(s)
- RaĂşl Capote-Puente
- Department of Physics of Condensed Matter, Optics Area, University of Seville, Sevilla, Spain
| | - Petar Eftimov
- Department of Cytology, Histology and Embryology, Sofia University St Kliment Ohridski, Sofia, Bulgaria
| | | | - Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | | | - Georgi Georgiev
- Faculty of Physics, Department of Optics and Spectroscopy, Sofia University St Kliment Ohridski, Sofia, Bulgaria
| |
Collapse
|
8
|
Capote-Puente R, Bautista-Llamas MJ, Manzoni C, Sánchez-González JM. Pre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lens. Life (Basel) 2022; 12:life12111710. [PMID: 36362865 PMCID: PMC9697334 DOI: 10.3390/life12111710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/16/2022] [Accepted: 10/24/2022] [Indexed: 11/16/2022] Open
Abstract
To evaluate pre-lens tear film volume, stability and lipid interferometry patterns with a silicone hydrogel water content contact lens, a novel, noninvasive, ocular-surface-analyzer technology was used. A prospective, longitudinal, single-center, self-control study was performed in daily or monthly replacement silicone hydrogel contact lens wearers. A tear film analysis was achieved with the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA) from SBM System. The subjects were reassessed, with the contact lens, after 30 min of wearing to quantify the volume, stability and lipid pattern of the short-term pre-lens tear film. Lipid layer thickness decreased from 2.05 ± 1.53 to 1.90 ± 1.73 Guillon patterns (p = 0.23). First pre-lens NIBUT decreased from 5.03 ± 1.04 to 4.63 ± 0.89 s (p = 0.01). Mean pre-lens NIBUT significantly increased from 15.19 ± 9.54 to 21.27 ± 11.97 s (p < 0.01). Lid opening time significantly increased from 26.36 ± 19.72 to 38.58 ± 21.78 s (p < 0.01). The silicone hydrogel contact lens with water gradient technology significantly increased the mean pre-lens NIBUT and lid opening time. Lehfilcon A suggested an improvement in contact lens wearers with tear film instability or decreased subjective symptoms of dry eye disease.
Collapse
Affiliation(s)
- RaĂşl Capote-Puente
- Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Optica Area, University of Seville, 41012 Seville, Spain
| | - MarĂa-JosĂ© Bautista-Llamas
- Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Optica Area, University of Seville, 41012 Seville, Spain
| | - Caterina Manzoni
- Department of Materials Science, Optics and Optometry Area, University of Milano-Bicocca, 20122 Milan, Italy
| | - JosĂ©-MarĂa Sánchez-González
- Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Optica Area, University of Seville, 41012 Seville, Spain
- Correspondence:
| |
Collapse
|
9
|
Fujimoto H, Ochi S, Inoue Y, Kiryu J. Upper Eyelid Meibomian Gland Dysfunction is a Risk Factor for Dry Eye Symptoms Following Cataract Surgery in the Early Phase. Clin Ophthalmol 2022; 16:293-302. [PMID: 35153474 PMCID: PMC8828079 DOI: 10.2147/opth.s346606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 01/27/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- Hisataka Fujimoto
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, 701-0192, Okayama, Japan
- Correspondence: Hisataka Fujimoto, Department of Ophthalmology, Kawasaki Medical School, 577 Matsushima, Kurashiki, 701-0192, Okayama, Japan, Tel +81-86-462-1111, Fax +81-86-462-1199, Email
| | | | - Yasushi Inoue
- Inoue Eye Clinic, Tamano, 706-0011, Okayama, Japan
- Yasushi Inoue, Inoue Eye Clinic, 1-14-31 Uno, Tamano, 706-0011, Okayama, Japan, Tel +81-86-331-1030, Fax +81-86-331-1114, Email
| | - Junichi Kiryu
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, 701-0192, Okayama, Japan
| |
Collapse
|