1
|
Smith JD, Bisignano K, Harrison WW. Test-retest repeatability in macular retinal oximetry. Clin Exp Optom 2024; 107:616-621. [PMID: 37844335 PMCID: PMC11018714 DOI: 10.1080/08164622.2023.2261928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 09/18/2023] [Accepted: 09/18/2023] [Indexed: 10/18/2023] Open
Abstract
CLINICAL RELEVANCE Evaluation of retinal macular oxygen saturation in healthy controls can aid in understanding the pathological changes seen in similar locations of those with vascular diseases like diabetes. BACKGROUND The aim of this study was to determine the test-retest repeatability of localised retinal oximetry measurements in the macula on the Zilia Oximeter within healthy subjects of different races, 18-40 years old. Oxygen saturation was measured between three time points within the same locations of the right eye. METHODS Twenty seven subjects were included (aged 26.3 ± 3.6 years). All were confirmed to have healthy retinas and at least 6/9 vision. Oximetry measurements were taken using the Zilia to acquire local oxygen saturation measurements (300 µm diameter) at four points 3.1 degrees from the fovea in the superior/temporal, superior/nasal, inferior/temporal, and inferior/nasal locations. Oximetry measurements were taken twice on the same day 20 minutes apart and then again 1-2 weeks later. Oximetry data was analysed with intraclass correlation between visits. To assess intrasubject repeatability, the Bland-Altman repeatability coefficient and coefficient of variation were calculated. RESULTS Average Intraclass correlation for the three acquisition times of the right eye was 0.78. The averaged intrasubject repeatability coefficient for the three acquisition times was 8.4. The averaged coefficient of variation was 5.4%. CONCLUSION The Zilia oximeter has good macular test-retest repeatability; however, multiple measurements may be needed to ensure accuracy.
Collapse
Affiliation(s)
- Jennyffer D Smith
- Department of Optometry, University of Houston College of Optometry, Houston, TX, USA
| | - Kelly Bisignano
- Department of Optometry, University of Houston College of Optometry, Houston, TX, USA
| | - Wendy W Harrison
- Department of Optometry, University of Houston College of Optometry, Houston, TX, USA
| |
Collapse
|
2
|
İnam O, El-Baz A, Kaplan HJ, Tezel TH. Colorimetric Analyses of the Optic Nerve Head and Retina Indicate Increased Blood Flow After Vitrectomy. Transl Vis Sci Technol 2024; 13:12. [PMID: 39007833 PMCID: PMC467108 DOI: 10.1167/tvst.13.7.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 06/03/2024] [Indexed: 07/16/2024] Open
Abstract
Purpose The purpose of this study was to evaluate the impact of vitrectomy and posterior hyaloid (PH) peeling on color alteration of optic nerve head (ONH) and retina as a surrogate biomarker of induced perfusion changes. Methods Masked morphometric and colorimetric analyses were conducted on preoperative (<1 month) and postoperative (<18 months) color fundus photographs of 54 patients undergoing vitrectomy, either with (44) or without (10) PH peeling and 31 years of age and gender-matched control eyes. Images were calibrated according to the hue and saturation values of the parapapillary venous blood column. Chromatic spectra of the retinal pigment epithelium and choroid were subtracted to avoid color aberrations. Red, green, and blue (RGB) bit values over the ONH and retina were plotted within the constructed RGB color space to analyze vitrectomy-induced color shift. Vitrectomy-induced parapapillary vein caliber changes were also computed morphometrically. Results A significant post-vitrectomy red hue shift was noted on the ONH (37.1 degrees ± 10.9 degrees vs. 4.1 degrees ± 17.7 degrees, P < 0.001), which indicates a 2.8-fold increase in blood perfusion compared to control (2.6 ± 1.9 vs. 0.9 ± 1.8, P < 0.001). A significant post-vitrectomy increase in the retinal vein diameter was also noticed (6.8 ± 6.4% vs. 0.1 ± 0.3%, P < 0.001), which was more pronounced with PH peeling (7.9 ± 6.6% vs. 3.1 ± 4.2%, P = 0.002). Conclusions Vitrectomy and PH peeling increase ONH and retinal blood flow. Colorimetric and morphometric analyses offer valuable insights for future artificial intelligence and deep learning applications in this field. Translational Relevance The methodology described herein can easily be applied in different clinical settings and may enlighten the beneficial effects of vitrectomy in several retinal vascular diseases.
Collapse
Affiliation(s)
- Onur İnam
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, New York, NY, USA
- Department of Biophysics, Faculty of Medicine, Gazi University, Ankara, Turkey
| | - Ayman El-Baz
- Bioengineering Department, University of Louisville, Louisville, KY, USA
| | - Henry J. Kaplan
- Department of Ophthalmology & Visual Sciences, Kentucky Lions Eye Center, University of Louisville School of Medicine, Louisville, KY, USA
- Department of Ophthalmology, Saint Louis University, School of Medicine, St. Louis, MO, USA
| | - Tongalp H. Tezel
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, New York, NY, USA
- Department of Ophthalmology & Visual Sciences, Kentucky Lions Eye Center, University of Louisville School of Medicine, Louisville, KY, USA
| |
Collapse
|
3
|
Gunay G, Ertas M, Yildirim I. Maximum-A-Posteriori Estimation of Retinal Oxygen Tension Based on Photon Counting Statistics. IEEE Trans Biomed Eng 2024; 71:2163-2169. [PMID: 38324445 DOI: 10.1109/tbme.2024.3363432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2024]
Abstract
The regularization of retinal oxygen tension estimation was previously proposed with an assumption that phosphorescence intensity images are corrupted by additive Gaussian noise. Based on this assumption, a regularized least-squares estimate has been shown to be better than a conventional least-squares estimation. However, this assumption is inconsistent with the acquisition process of phosphorescence intensity images acquired using an intensified charge-coupled device camera. Almost the entire acquisition process is governed by the natural aspects of photons. Therefore, a method based on photon counting statistics is more appropriate. In this study, we propose a regularized oxygen tension estimation method based on photon counting statistics and a phosphorescence lifetime imaging model.
Collapse
|
4
|
Quaresima V, Ferrari M, Scholkmann F. Ninety years of pulse oximetry: history, current status, and outlook. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S33307. [PMID: 39156662 PMCID: PMC11330276 DOI: 10.1117/1.jbo.29.s3.s33307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 07/11/2024] [Accepted: 07/17/2024] [Indexed: 08/20/2024]
Abstract
Significance This year, 2024, marks the 50th anniversary of the invention of pulse oximetry (PO), which was first presented by Takuo Aoyagi, an engineer from the Nihon Kohden Company, at the 13th Conference of the Japanese Society of Medical Electronics and Biological Engineering in Osaka in 1974. His discovery and the development of PO for the non-invasive measurement of peripheral arterial oxygenation represents one of the most significant chapters in the history of medical technology. It resulted from research and development efforts conducted by biochemists, engineers, physicists, physiologists, and physicians since the 1930s. Aim The objective of this work was to provide a narrative review of the history, current status, and future prospects of PO. Approach A comprehensive review of the literature on oximetry and PO was conducted. Results and Conclusions Our historical review examines the development of oximetry in general and PO in particular, tracing the key stages of a long and fascinating story that has unfolded from the first half of the twentieth century to the present day-an exciting journey in which serendipity has intersected with the hard work of key pioneers. This work has been made possible by the contributions of numerous key pioneers, including Kurt Kramer, Karl Matthes, Glenn Millikan, Evgenii M. Kreps, Earl H. Wood, Robert F. Show, Scott A. Wilber, William New, and, above all, Takuo Aoyagi. PO has become an integral part of modern medical care and has proven to be an important tool for physiological monitoring. The COVID-19 pandemic not only highlighted the clinical utility of PO but also revealed some of the problems with the technology. Current research in biomedical optics should address these issues to make the technology even more reliable and accurate. We discuss the necessary innovations in PO and present our thoughts on what the next generation of PO might look like.
Collapse
Affiliation(s)
- Valentina Quaresima
- University of L'Aquila, Department of Life, Health and Environmental Science, L'Aquila, Italy
| | - Marco Ferrari
- University of L'Aquila, Department of Life, Health and Environmental Science, L'Aquila, Italy
| | - Felix Scholkmann
- University Hospital Zurich, University of Zurich, Biomedical Optics Research Laboratory, Department of Neonatology, Neurophotonics and Biosignal Processing Research Group, Zurich, Switzerland
- University of Bern, Institute of Complementary and Integrative Medicine, Bern, Switzerland
- University of Zurich and ETH Zurich, Neuroscience Center Zurich, Zurich, Switzerland
| |
Collapse
|
5
|
Guldfeldt MU, Pilegaard FP, Malmqvist L, Klefter ON, Hamann S. Validation of retinal oximetry vessel selection using fluorescein angiography in patients with optic disc drusen. Exp Eye Res 2024; 243:109882. [PMID: 38582182 DOI: 10.1016/j.exer.2024.109882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 03/27/2024] [Accepted: 03/28/2024] [Indexed: 04/08/2024]
Abstract
Retinal oximetry could provide insights into the pathophysiology of optic nerve disease, including optic disc drusen (ODD). Vessel selection for oximetry analysis is based on morphological characteristics of arterioles and venules and supported by an overlay of estimated blood oxygen saturations. The purpose of this cross-sectional study was to determine the validity of this vessel selection procedure by comparing it with vessel selection supported by video fluorescein angiography (FA). The study included 36 eyes of 36 patients with ODD who underwent retinal oximetry (Oxymap retinal oximeter T1) followed by FA (Heidelberg Spectralis). Two trained graders selected vessel segments in a pre-defined measurement area around the optic disc. One of these graders additionally performed the vessel segment selection with the support of FA images. When performed by the same grader, FA-supported and non-FA-supported vessel selection did not lead to significant differences in total vessel segment length, estimated oxygen saturations or vessel diameters (all p > 0.05). Inter-grader differences were found for arterial and venous segment lengths and arterial saturation (p < 0.05). A similar tendency was found for the arteriovenous saturation difference (p = 0.10). In conclusion, identifying vessel segments for retinal oximetry analysis based on vessel morphology and supported by a color-coded saturation overlay appears to be a valid method without the need for invasive angiography. A numerically small inter-grader variation may influence oximetry results. Further studies of retinal oximetry in ODD are warranted.
Collapse
Affiliation(s)
- Mia Uhre Guldfeldt
- Department of Ophthalmology, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Freja Pind Pilegaard
- Department of Ophthalmology, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Lasse Malmqvist
- Department of Ophthalmology, Rigshospitalet, Copenhagen, Denmark
| | - Oliver Niels Klefter
- Department of Ophthalmology, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Steffen Hamann
- Department of Ophthalmology, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.
| |
Collapse
|
6
|
Saeed A, Hadoux X, van Wijngaarden P. Hyperspectral retinal imaging biomarkers of ocular and systemic diseases. Eye (Lond) 2024:10.1038/s41433-024-03135-9. [PMID: 38778136 DOI: 10.1038/s41433-024-03135-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 02/20/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024] Open
Abstract
Hyperspectral imaging is a frontier in the field of medical imaging technology. It enables the simultaneous collection of spectroscopic and spatial data. Structural and physiological information encoded in these data can be used to identify and localise typically elusive biomarkers. Studies of retinal hyperspectral imaging have provided novel insights into disease pathophysiology and new ways of non-invasive diagnosis and monitoring of retinal and systemic diseases. This review provides a concise overview of recent advances in retinal hyperspectral imaging.
Collapse
Affiliation(s)
- Abera Saeed
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, 3002, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, 3002, VIC, Australia
| | - Xavier Hadoux
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, 3002, VIC, Australia
| | - Peter van Wijngaarden
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, 3002, VIC, Australia.
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, 3002, VIC, Australia.
| |
Collapse
|
7
|
Venkatesh R, Handa A, Chitturi SP, Choudhary A, Prabhu V, Acharya I, Mangla R, Yadav NK, Chhablani J. Right-angled vessel characteristics in different stages of type 2 macular telangiectasia (MacTel). Eye (Lond) 2024; 38:1162-1167. [PMID: 38012385 PMCID: PMC11009321 DOI: 10.1038/s41433-023-02853-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 10/30/2023] [Accepted: 11/14/2023] [Indexed: 11/29/2023] Open
Abstract
PURPOSE To study right-angled vessels (RAV) in disease progression and macular neovascularization in type 2 macular telangiectasia (MacTel) eyes. METHODS This retrospective image analysis study examined type 2 MacTel patients' multicolour® and OCT imaging records from January 2015 to March 2023. Age, gender, laterality, visual acuity, systemic disease, and follow-up duration were recorded. RAV characteristics were assessed using OCT and multicolour® images. This study examined RAV characteristics and type 2 MacTel disease stage. RESULTS In total, 270 eyes of 146 patients (97 females, 66%) with a mean age of 60.77 ± 9.34 years were studied. 153 (57%) eyes showed RAV. The non-proliferative stage of type 2 MacTel had either no RAV or a normal-calibre right-angled vein, while the proliferative stage had a right-angled artery and a dilated or normal-calibre RAV [p < 0.001]. RAV characteristics differed at the final follow-up (p < 0.001). 11 eyes transitioned from non-proliferative to proliferative after a median period of 26 months (range: 5-96 months). RAV characteristics changed from a normal calibre right-angled vein at presentation to a normal calibre vein and artery in 6 (55%) eyes and to a dilated vein and artery in 5 (45%) eyes respectively. CONCLUSION RAV characteristics may indicate type 2 MacTel stages. A right-angled artery in type 2 MacTel may indicate proliferative disease.
Collapse
Affiliation(s)
- Ramesh Venkatesh
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India.
| | - Ashit Handa
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Sai Prashanti Chitturi
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Ayushi Choudhary
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Vishma Prabhu
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Isha Acharya
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Rubble Mangla
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Naresh Kumar Yadav
- Dept. of Retina and Vitreous Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, Karnataka, India
| | - Jay Chhablani
- University of Pittsburgh School of Medicine, Medical Retina and Vitreoretinal Surgery, 203 Lothrop Street, Suite 800, Pittsburg, PA, 15213, USA
| |
Collapse
|
8
|
Polidar P, Paskova B, Karhanova M, Sin M, Dornak T, Schreiberova Z, Divisova P, Veverka T, Franc D, Sanak D, Kral M. Study protocol - Prospective case-control trial - Impact of significant carotid stenosis on retinal perfusion measured with automated retinal oximetry. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2024. [PMID: 38192247 DOI: 10.5507/bp.2023.052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND Large vessel carotid stenosis is a significant cause of ischaemic stroke. Indications for surgical revascularisation depend on the severity of the stenosis and clinical symptoms. However, mild symptoms such as TIA (Transient ischaemic attack), amaurosis fugax or minor stroke precede large strokes in only 15% of cases. AIM The aim of this prospective study is to evaluate whether retinal perfusion is impacted in significant carotid stenosis. Automated retinal oximetry will be used to better assess perfusion in the post-stenotic basin. We presume the more stenotic the blood vessel, the more reduced the retinal perfusion is, resulting in adaptive changes such as greater arteriovenous saturation difference due to greater oxygen extraction. This could broaden the indication spectrum for revascularisation for carotid stenosis. METHODS We plan to enroll yearly 50 patients with significant carotid stenosis and cross-examine them with retinal oximetry. The study group will provide stenotic vessels and, non-stenotic vessels will form the control group. Patients with significant carotid stenosis will undergo an MRI (Magnetic Resonnance imaging) examination to determine the presence of asymptomatic recent ischaemic lesions in the stenotic basin, and the correlation to oximetry parameters. STATISTICS The stenosis severity and retinal oximetry parameters will be compared for study and control groups with a threshold of 70%, respectively 80% and 90% stenosis. Results will be then reevaluated with emphasis on MRI findings in the carotid basin. CONCLUSION This prospective case control study protocol will be used to launch a multicentre trial assessing the relationship between significant carotid stenosis and retinal perfusion measured with automated retinal oximetry. Despite these differences, the findings indicate the potential of retinal oximetry for noninvasive real-time measurements of oxyhaemoglobin saturation in central nervous system vessels. Following calibration upgrade and technological improvement, verification retinal oximetry may potentially be applied to critically ill and anaesthesia care patients. The study on combined scanning laser ophthalmoscope and retinal oximetry supports the feasibility of the technique for oximetry analysis in newly born babies. TRIAL REGISTRATION ClinicalTrials.gov, ID: NCT06085612.
Collapse
Affiliation(s)
- Petr Polidar
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| | - Barbora Paskova
- Department of Ophthalmology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Ophthalmology, University Hospital Olomouc, Czech Republic
| | - Marta Karhanova
- Department of Ophthalmology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Ophthalmology, University Hospital Olomouc, Czech Republic
| | - Martin Sin
- Department of Ophthalmology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Ophthalmology, Central Military Hospital Prague, Czech Republic
| | - Tomas Dornak
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| | - Zuzana Schreiberova
- Department of Ophthalmology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Ophthalmology, University Hospital Olomouc, Czech Republic
| | - Petra Divisova
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| | - Tomas Veverka
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| | - David Franc
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| | - Daniel Sanak
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| | - Michal Kral
- Department of Neurology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
- Department of Neurology, University Hospital Olomouc, Czech Republic
| |
Collapse
|
9
|
Wang J, Sadlak N, Fiorello MG, Desai M, Yi J. Macular Oxygen Saturation in Glaucoma Using Retinal Oximetry of Visible Light Optical Coherence Tomography. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.12.20.23300300. [PMID: 38196641 PMCID: PMC10775404 DOI: 10.1101/2023.12.20.23300300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
Purpose Oxygen saturation (sO2) plays a critical role in retinal pathophysiology, especially at the macula, which undergoes significant energy consumption. While macular damage has been suggested to be involved in early-stage glaucoma, there has been no report to date on non-invasive macular sO2 in glaucoma. Therefore, we conducted this study to compare macular sO2 associated with other clinical measurements between normal and glaucoma subjects and evaluate whether there are significant differences. Method This is a cross-sectional study. We used visible light optical coherence tomography (VIS-OCT) for retinal oximetry in perifoveal vessels. The subjects from groups of normal, suspect/pre-perimetric glaucoma (GS/PPG) and perimetric glaucoma (PG) were scanned using VIS-OCT in the macular region with a sampling density of 512×256 in an area of 5×5 mm2. 48 eyes (16 normal, 17 GS/PPG and 15 PG) were included for the analysis. For each eye, we measured the sO2 of arterioles (AsO2), venules (VsO2), and calculated the difference between arterioles and venules (A-V sO2=AsO2-VsO2), oxygen extraction (OE=(AsO2-VsO2)/AsO2 ×100%). Additionally, we included Zeiss Cirrus OCT scans and 24-2 visual field test (VFT) for clinical benchmark. One-way ANOVA was used to compare the differences among the three groups. Spearman correlation tests were used for correlation sO2 markers to standard metrics including the thickness of ganglion cell layer and inner plexiform layer (GCL+IPL), circumpapillary retinal nerve fiber layer (cpRNFL) and mean deviation (MD) in VFT. Result Significant differences were found among three groups for all VIS-OCT, Zeiss OCT, and VFT variables. Macular AsO2, A-V sO2, OE decreased, and VsO2 increased along with severity. Macular AsO2 and A-V sO2 were statistically correlated with GCL+IPL and cpRNFL in all eyes, as well as only PG eyes. Within PG eyes, the correlation between AsO2 and GCL+IPL is dominant in more damaged lower hemifield. Conclusion The GS/PPG and PG subjects had significantly higher macular VsO2, lower A-V sO2 and OE indicating less oxygen consumption. The sO2 measured by retinal oximetry of VIS-OCT can be a potential metric for the early diagnosis of glaucoma.
Collapse
Affiliation(s)
- Jingyu Wang
- Department of Ophthalmology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Natalie Sadlak
- Department of Ophthalmology, Boston Medical Center, Boston, MA, USA
| | | | - Manishi Desai
- Department of Ophthalmology, Boston Medical Center, Boston, MA, USA
| | - Ji Yi
- Department of Ophthalmology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston, MA, USA
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
10
|
Hirsch K, Cubbidge RP, Heitmar R. Dual wavelength retinal vessel oximetry - influence of fundus pigmentation. Eye (Lond) 2023; 37:2246-2251. [PMID: 36460856 PMCID: PMC9716545 DOI: 10.1038/s41433-022-02325-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 11/17/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND Clinical methods examining oxygenation parameters in humans have been used in many different care settings, but concerns have been raised regarding their clinical utility when assessing people with darker skin pigmentation. While saturation values can be crucial in emergency medicine, they are equally valuable in assessing disease mechanisms and monitoring change in disease progression. Retinal pigmentation varies across individuals and hence, can impact on retinal oxygen parameters. The objective of this study was to quantify and eliminate the impact of retinal pigmentation on retinal vessel oxygen saturation parameters measured in the superficial retinal arterioles and venules. METHODS 105 healthy individuals of varying skin colour, iris colour and heritage were included. Following a full eye exam to exclude any ocular abnormality, all participants underwent intraocular pressure, systemic blood pressure measurements and dilated dual wavelength retinal photography. Rotation matrices were employed to minimise the dependency of retinal pigmentation on arterial and venous oxygen saturation measurements determined in a concentric measurement annulus. RESULTS Retinal oxygen saturation in venules showed a linear correlation with retinal pigmentation (y = 0.34 × x + 38.598), whereas arterial saturation followed a polynomial pattern (y = 0.0089 × x2 + 0.7499 × x + 85.073). Both arterial and venous saturation values were corrected using local fundus pigmentation. Pre-correction retinal arterial and venous oxygen saturation were 89.0% (±13.1) and 43.7% (±11.5), respectively, and post- correction values were 94.8% (±8.7) for arteries and 56.3% (±7.0) veins. CONCLUSIONS When assessing multi-ethnic cohorts, it is important to consider the impact of pigmentation on imaging parameters and to account for it prior to clinical interpretation.
Collapse
Affiliation(s)
- Katrin Hirsch
- The University of the West of England, School of Health and Social Wellbeing, Glenside Campus, Bristol, BS16 1DD, UK.
| | - Robert P Cubbidge
- ABDO College, Godmersham Park, Canterbury, Kent, CT4 7DT, UK
- Aston University, Aston Triangle, Birmingham, B4 7ET, UK
| | - Rebekka Heitmar
- University of Huddersfield, School of Applied Sciences, Centre for Vision across the Life Span, Queensgate, HD1 3DH, UK.
| |
Collapse
|
11
|
Heitmar R, Link D, Kotliar K, Schmidl D, Klee S. Editorial: Functional assessments of the ocular circulation. Front Med (Lausanne) 2023; 10:1222022. [PMID: 37359007 PMCID: PMC10285660 DOI: 10.3389/fmed.2023.1222022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 05/16/2023] [Indexed: 06/28/2023] Open
Affiliation(s)
- Rebekka Heitmar
- Centre for Vision Across the Lifespan, School of Applied Sciences, University of Huddersfield, Huddersfield, United Kingdom
| | - Dietmar Link
- Division Optoelectrophysiological Engineering, Department of Computer Science and Automation, Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - Konstantin Kotliar
- Medical Engineering and Technomathematics, Aachen University of Applied Sciences, Aachen, Germany
| | - Doreen Schmidl
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Sascha Klee
- Division Optoelectrophysiological Engineering, Department of Computer Science and Automation, Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
- Division Biostatistics and Data Science, Department General Health Studies, Karl Landsteiner University of Health Sciences, Krems an der Donau, Austria
| |
Collapse
|
12
|
Jin K, Shen W, Liang Y, He M. Epidemiology, Translation and Clinical Research of Ophthalmology. J Clin Med 2023; 12:3819. [PMID: 37298014 PMCID: PMC10253839 DOI: 10.3390/jcm12113819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023] Open
Abstract
The human eye is a complex and vital organ that plays a significant role in maintaining a high quality of human life [...].
Collapse
Affiliation(s)
- Kai Jin
- Eye Center, The Second Affiliated Hospital School of Medicine Zhejiang University, Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang Provincial Clinical Research Center for Eye Diseases, Zhejiang Provincial Engineering Institute on Eye Diseases, Hangzhou 310009, China;
| | - Wenyue Shen
- Eye Center, The Second Affiliated Hospital School of Medicine Zhejiang University, Zhejiang Provincial Key Laboratory of Ophthalmology, Zhejiang Provincial Clinical Research Center for Eye Diseases, Zhejiang Provincial Engineering Institute on Eye Diseases, Hangzhou 310009, China;
| | - Yuanbo Liang
- National Clinical Research Center for Ocular Diseases, Eye Hospital of Wenzhou Medical University, Wenzhou 325027, China;
| | - Mingguang He
- Centre for Eye Research Australia, Royal Victorian, Eye and Ear Hospital, University of Melbourne, Melbourne 3002, Australia
| |
Collapse
|
13
|
Zhang J, Luo Z, Wang G, Huang Y, Fei K, Liu Y, Li J, Yuan J, Xiao P. Oxygen-saturation-related functional parameter as a biomarker for diabetes mellitus-extraction method and clinical validation. Front Cell Dev Biol 2023; 11:1195873. [PMID: 37250897 PMCID: PMC10213938 DOI: 10.3389/fcell.2023.1195873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 05/02/2023] [Indexed: 05/31/2023] Open
Abstract
Purpose: To develop a computational method for oxygen-saturation-related functional parameter analysis of retinal vessels based on traditional color fundus photography, and to explore their characteristic alterations in type 2 diabetes mellitus (DM). Methods: 50 type 2 DM patients with no-clinically detectable retinopathy (NDR) and 50 healthy subjects were enrolled in the study. An optical density ratio (ODR) extraction algorithm based on the separation of oxygen-sensitive and oxygen-insensitive channels in color fundus photography was proposed. With precise vascular network segmentation and arteriovenous labeling, ODRs were acquired from different vascular subgroups, and the global ODR variability (ODRv) was calculated. Student's t-test was used to analyze the differences of the functional parameters between groups, and regression analysis and receiver operating characteristic (ROC) curves were used to explore the discrimination efficiency of DM patients from healthy subjects based on these functional parameters. Results: There was no significant difference in the baseline characteristics between the NDR and healthy normal groups. The ODRs of all vascular subgroups except the micro venule were significantly higher (p<0.05, respectively) while ODRv was significantly lower (p<0.001) in NDR group than that in healthy normal group. In the regression analysis, the increased ODRs except micro venule and decreased ODRv were significantly correlated with the incidence of DM, and the C-statistic for discrimination DM with all ODR is 0.777 (95% CI 0.687-0.867, p<0.001). Conclusion: A computational method to extract the retinal vascular oxygen-saturation-related optical density ratios (ODRs) with single color fundus photography was developed, and increased ODRs and decreased ODRv of retinal vessels could be new potential image biomarkers of DM.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Jin Yuan
- *Correspondence: Jin Yuan, ; Peng Xiao,
| | - Peng Xiao
- *Correspondence: Jin Yuan, ; Peng Xiao,
| |
Collapse
|
14
|
Rubinoff I, Kuranov RV, Fang R, Ghassabi Z, Wang Y, Beckmann L, Miller DA, Wollstein G, Ishikawa H, Schuman JS, Zhang HF. Adaptive spectroscopic visible-light optical coherence tomography for clinical retinal oximetry. COMMUNICATIONS MEDICINE 2023; 3:57. [PMID: 37095177 PMCID: PMC10126115 DOI: 10.1038/s43856-023-00288-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 04/13/2023] [Indexed: 04/26/2023] Open
Abstract
BACKGROUND Retinal oxygen saturation (sO2) provides essential information about the eye's response to pathological changes that can result in vision loss. Visible-light optical coherence tomography (vis-OCT) is a noninvasive tool that has the potential to measure retinal sO2 in a clinical setting. However, its reliability is currently limited by unwanted signals referred to as spectral contaminants (SCs), and a comprehensive strategy to isolate true oxygen-dependent signals from SCs in vis-OCT is lacking. METHODS We develop an adaptive spectroscopic vis-OCT (ADS-vis-OCT) technique that can adaptively remove SCs and accurately measure sO2 under the unique conditions of each vessel. We also validate the accuracy of ADS-vis-OCT using ex vivo blood phantoms and assess its repeatability in the retina of healthy volunteers. RESULTS In ex vivo blood phantoms, ADS-vis-OCT agrees with a blood gas machine with only a 1% bias in samples with sO2 ranging from 0% to 100%. In the human retina, the root mean squared error between sO2 values in major arteries measured by ADS-vis-OCT and a pulse oximeter is 2.1% across 18 research participants. Additionally, the standard deviations of repeated ADS-vis-OCT measurements of sO2 values in smaller arteries and veins are 2.5% and 2.3%, respectively. Non-adaptive methods do not achieve comparable repeatabilities from healthy volunteers. CONCLUSIONS ADS-vis-OCT effectively removes SCs from human images, yielding accurate and repeatable sO2 measurements in retinal arteries and veins with varying diameters. This work could have important implications for the clinical use of vis-OCT to manage eye diseases.
Collapse
Affiliation(s)
- Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Roman V Kuranov
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Opticent Inc., Evanston, IL, 60201, USA
| | - Raymond Fang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Zeinab Ghassabi
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Yuanbo Wang
- Currently with Department of Ophthalmology, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Lisa Beckmann
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - David A Miller
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Gadi Wollstein
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Hiroshi Ishikawa
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
- Currently with Department of Ophthalmology, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Joel S Schuman
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Hao F Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
15
|
Hommer N, Kallab M, Schlatter A, Howorka K, Werkmeister RM, Schmidl D, Schmetterer L, Garhöfer G. Retinal Oxygen Metabolism in Patients With Type 2 Diabetes and Different Stages of Diabetic Retinopathy. Diabetes 2022; 71:2677-2684. [PMID: 36107468 PMCID: PMC9862478 DOI: 10.2337/db22-0219] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 09/11/2022] [Indexed: 02/05/2023]
Abstract
The aim of this cross-sectional study was to assess retinal oxygen metabolism in patients with type 2 diabetes and different stages of nonproliferative diabetic retinopathy (DR) (n = 67) compared with healthy control subjects (n = 20). Thirty-four patients had no DR, 15 had mild DR, and 18 had moderate to severe DR. Retinal oxygen saturation in arteries and veins was measured using the oxygen module of a retinal vessel analyzer. Total retinal blood flow (TRBF) was measured using a custom-built Doppler optical coherence tomography system. Retinal oxygen extraction was calculated from retinal oxygen saturation and TRBF. Arteriovenous difference in oxygen saturation was highest in healthy subjects (34.9 ± 7.5%), followed by patients with no DR (32.5 ± 6.3%) and moderate to severe DR (30.3 ± 6.5%). The lowest values were found in patients with mild DR (27.3 ± 8.0%, P = 0.010 vs. healthy subjects). TRBF tended to be higher in patients with no DR (40.1 ± 9.2 μL/min) and mild DR (41.8 ± 15.0 μL/min) than in healthy subjects (37.2 ± 5.7 μL/min) and patients with moderate to severe DR (34.6 ± 10.4 μL/min). Retinal oxygen extraction was the highest in healthy subjects (2.24 ± 0.57 μL O2/min), followed by patients with no DR (2.14 ± 0.6 μL O2/min), mild DR (1.90 ± 0.77 μL O2/min), and moderate to severe DR (1.78 ± 0.57 μL O2/min, P = 0.040 vs. healthy subjects). These results indicate that retinal oxygen metabolism is altered in patients with type 2 diabetes. Furthermore, retinal oxygen extraction decreases with increasing severity of DR.
Collapse
Affiliation(s)
- Nikolaus Hommer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Martin Kallab
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Andreas Schlatter
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Vienna Institute for Research in Ocular Surgery, Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria
| | - Kinga Howorka
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - René M. Werkmeister
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Doreen Schmidl
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Leopold Schmetterer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
- Singapore Eye Research Institute-Nanyang Technical University Advanced Ocular Engineering (STANCE), Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - Gerhard Garhöfer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
16
|
Nanegrungsunk O, Patikulsila D, Sadda SR. Ophthalmic imaging in diabetic retinopathy: A review. Clin Exp Ophthalmol 2022; 50:1082-1096. [PMID: 36102668 PMCID: PMC10088017 DOI: 10.1111/ceo.14170] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/01/2022] [Accepted: 09/09/2022] [Indexed: 11/30/2022]
Abstract
Retinal imaging has been a key tool in the diagnosis, evaluation, management and documentation of diabetic retinopathy (DR) and diabetic macular oedema (DMO) for many decades. Imaging technologies have rapidly evolved over the last few decades, yielding images with higher resolution and contrast with less time, effort and invasiveness. While many retinal imaging technologies provide detailed insight into retinal structure such as colour reflectance photography and optical coherence tomography (OCT), others such as fluorescein or OCT angiography and oximetry provide dynamic and functional information. Many other novel imaging technologies are in development and are poised to further enhance our evaluation of patients with DR.
Collapse
Affiliation(s)
- Onnisa Nanegrungsunk
- Doheny Imaging Reading Center Doheny Eye Institute Pasadena California USA
- David Geffen School of Medicine University of California‐Los Angeles Los Angeles California USA
- Retina Division, Department of Ophthalmology Chiang Mai University Chiang Mai Thailand
| | - Direk Patikulsila
- Retina Division, Department of Ophthalmology Chiang Mai University Chiang Mai Thailand
| | - Srinivas R. Sadda
- Doheny Imaging Reading Center Doheny Eye Institute Pasadena California USA
- David Geffen School of Medicine University of California‐Los Angeles Los Angeles California USA
| |
Collapse
|
17
|
Taylor-Williams M, Spicer G, Bale G, Bohndiek SE. Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220074VR. [PMID: 35922891 PMCID: PMC9346606 DOI: 10.1117/1.jbo.27.8.080901] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/27/2022] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their depth of imaging, spatiotemporal resolution, sensitivity, accuracy, complexity, physical size, and cost. The wide variation in available instrumentation can make it challenging for end users to select the appropriate tools for their application and to understand the relative limitations of different methods. AIM We aim to provide a systematic overview of the field of hemoglobin imaging and sensing. APPROACH We reviewed the sensing and imaging methods used to analyze hemoglobin oxygenation, including pulse oximetry, spectral reflectance imaging, diffuse optical imaging, spectroscopic optical coherence tomography, photoacoustic imaging, and diffuse correlation spectroscopy. RESULTS We compared and contrasted the ability of different methods to determine hemoglobin biomarkers such as oxygenation while considering factors that influence their practical application. CONCLUSIONS We highlight key limitations in the current state-of-the-art and make suggestions for routes to advance the clinical use and interpretation of hemoglobin oxygenation information.
Collapse
Affiliation(s)
- Michaela Taylor-Williams
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Graham Spicer
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Gemma Bale
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Electrical Division, Department of Engineering, Cambridge, United Kingdom, United Kingdom
| | - Sarah E Bohndiek
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| |
Collapse
|
18
|
Sharif NA. Degeneration of retina-brain components and connections in glaucoma: Disease causation and treatment options for eyesight preservation. CURRENT RESEARCH IN NEUROBIOLOGY 2022; 3:100037. [PMID: 36685768 PMCID: PMC9846481 DOI: 10.1016/j.crneur.2022.100037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 03/30/2022] [Accepted: 04/01/2022] [Indexed: 01/25/2023] Open
Abstract
Eyesight is the most important of our sensory systems for optimal daily activities and overall survival. Patients who experience visual impairment due to elevated intraocular pressure (IOP) are often those afflicted with primary open-angle glaucoma (POAG) which slowly robs them of their vision unless treatment is administered soon after diagnosis. The hallmark features of POAG and other forms of glaucoma are damaged optic nerve, retinal ganglion cell (RGC) loss and atrophied RGC axons connecting to various brain regions associated with receipt of visual input from the eyes and eventual decoding and perception of images in the visual cortex. Even though increased IOP is the major risk factor for POAG, the disease is caused by many injurious chemicals and events that progress slowly within all components of the eye-brain visual axis. Lowering of IOP mitigates the damage to some extent with existing drugs, surgical and device implantation therapeutic interventions. However, since multifactorial degenerative processes occur during aging and with glaucomatous optic neuropathy, different forms of neuroprotective, nutraceutical and electroceutical regenerative and revitalizing agents and processes are being considered to combat these eye-brain disorders. These aspects form the basis of this short review article.
Collapse
Affiliation(s)
- Najam A. Sharif
- Duke-National University of Singapore Medical School, Singapore,Singapore Eye Research Institute (SERI), Singapore,Department of Pharmacology and Neuroscience, University of North Texas Health Sciences Center, Fort Worth, Texas, USA,Department of Pharmaceutical Sciences, Texas Southern University, Houston, TX, USA,Department of Surgery & Cancer, Imperial College of Science and Technology, St. Mary's Campus, London, UK,Department of Pharmacy Sciences, School of School of Pharmacy and Health Professions, Creighton University, Omaha, NE, USA,Ophthalmology Innovation Center, Santen Incorporated, 6401 Hollis Street (Suite #125), Emeryville, CA, 94608, USA,Ophthalmology Innovation Center, Santen Incorporated, 6401 Hollis Street (Suite #125), Emeryville, CA, 94608, USA.
| |
Collapse
|
19
|
Akitegetse C, Landry P, Robidoux J, Lapointe N, Brouard D, Sauvageau D. Monte-Carlo simulation and tissue-phantom model for validation of ocular oximetry. BIOMEDICAL OPTICS EXPRESS 2022; 13:2929-2946. [PMID: 35774309 PMCID: PMC9203094 DOI: 10.1364/boe.458079] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 03/27/2022] [Accepted: 04/11/2022] [Indexed: 06/15/2023]
Abstract
Ocular oximetry, in which blood oxygen saturation is evaluated in retinal tissues, is a promising technique for the prevention, diagnosis and management of many diseases and conditions. However, the development of new tools for evaluating oxygen saturation in the eye fundus has often been limited by the lack of reference tools or techniques for such measurements. In this study, we describe a two-step validation method. The impact of scattering, blood volume fraction and lens yellowing on the oximetry model is investigated using a tissue phantom, while a Monte Carlo model of the light propagation in the eye fundus is used to study the effect of the fundus layered-structure. With this method, we were able to assess the performance of an ocular oximetry technique in the presence of confounding factors and to quantify the impact of the choroidal circulation on the accuracy of the measurements. The presented strategy will be useful to anyone involved in studies based on the eye fundus diffuse reflectance.
Collapse
Affiliation(s)
| | - Patricia Landry
- Affaires médicales et innovation, Héma-Québec, Québec, QC, G1V 5C3, Canada
| | - Jonathan Robidoux
- Affaires médicales et innovation, Héma-Québec, Québec, QC, G1V 5C3, Canada
| | | | - Danny Brouard
- Affaires médicales et innovation, Héma-Québec, Québec, QC, G1V 5C3, Canada
| | - Dominic Sauvageau
- Zilia inc., Québec, QC, G1K 3G5, Canada
- Chemical and Materials Engineering, University of Alberta, Edmonton, AB, T6G 1H9, Canada
| |
Collapse
|
20
|
Wang J, Baker A, Subramanian ML, Siegel NH, Chen X, Ness S, Yi J. Simultaneous visible light optical coherence tomography and near infrared OCT angiography in retinal pathologies: A case study. Exp Biol Med (Maywood) 2022; 247:377-384. [PMID: 34904454 PMCID: PMC8919322 DOI: 10.1177/15353702211063839] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
A dual-channel optical coherence tomography system with wavelengths in the visible and near-infrared light ranges can provide both structural and functional information for retinal microvasculature simultaneously. We applied this integrated system in an ongoing clinical study of patients with various retinal pathologies. Here, we present case study results of patients with diabetic retinopathy, central retinal vein occlusion, and sickle cell retinopathy compared to a healthy subject. For the first time, this comparison validates the system's ability to detect structural anomalies in both en face and B-scan images with simultaneous retinal optical coherence tomography angiography and measurement of sO2 in parafoveal vessels that are around 20-30 µm in diameter. This integrated system represents a powerful instrument with potentially far-reaching clinical implications for the early detection and diagnosis of retinal vascular diseases.
Collapse
Affiliation(s)
- Jingyu Wang
- Department of Ophthalmology, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Andrew Baker
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Manju L Subramanian
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Nicole H Siegel
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Xuejing Chen
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Steven Ness
- Department of Ophthalmology, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118, USA
| | - Ji Yi
- Department of Ophthalmology, Johns Hopkins University, Baltimore, MD 21231, USA,Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA,Ji Yi.
| |
Collapse
|
21
|
Christinaki E, Kulenovic H, Hadoux X, Baldassini N, Van Eijgen J, De Groef L, Stalmans I, van Wijngaarden P. Retinal imaging biomarkers of neurodegenerative diseases. Clin Exp Optom 2022; 105:194-204. [PMID: 34751086 DOI: 10.1080/08164622.2021.1984179] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
The timely detection of neurodegenerative diseases is central to improving clinical care as well as enabling the development and deployment of disease-modifying therapies. Retinal imaging is emerging as a method to detect features of a number of neurodegenerative diseases, given the anatomical and functional similarities between the retina and the brain. This review provides an overview of the current status of retinal imaging biomarkers of neurodegenerative diseases including Alzheimer's disease, Parkinson's disease, Lewy body dementia, frontotemporal dementia, Huntington's disease and multiple sclerosis. Whilst research findings are promising, efforts to harmonise study designs and imaging methods will be important in translating these findings into clinical care. Doing so may mean that eye care providers will play important roles in the detection of a variety of neurodegenerative diseases in future.
Collapse
Affiliation(s)
- Eirini Christinaki
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium
| | - Hana Kulenovic
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium
| | - Xavier Hadoux
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
| | - Nicole Baldassini
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
| | - Jan Van Eijgen
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium.,Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium
| | - Lies De Groef
- Neural Circuit Development and Regeneration Research Group, Department of Biology, University of Leuven (KU Leuven), Leuven, Belgium.,Leuven Brain Institute, Leuven, Belgium
| | - Ingeborg Stalmans
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium.,Department of Ophthalmology, University Hospitals Leuven, Leuven, Belgium.,Neural Circuit Development and Regeneration Research Group, Department of Biology, University of Leuven (KU Leuven), Leuven, Belgium
| | - Peter van Wijngaarden
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, University of Melbourne, Parkville, Australia
| |
Collapse
|
22
|
Beach JM, Rizvi M, Lichtenfels CB, Vince R, More SS. Topical Review: Studies of Ocular Function and Disease Using Hyperspectral Imaging. Optom Vis Sci 2022; 99:101-113. [PMID: 34897230 DOI: 10.1097/opx.0000000000001853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Advances in imaging technology over the last two decades have produced significant innovations in medical imaging. Hyperspectral imaging (HSI) is one of these innovations, enabling powerful new imaging tools for clinical use and greater understanding of tissue optical properties and mechanisms underlying eye disease.Hyperspectral imaging is an important and rapidly growing area in medical imaging, making possible the concurrent collection of spectroscopic and spatial information that is usually obtained from separate optical recordings. In this review, we describe several mainstream techniques used in HSI, along with noteworthy advances in optical technology that enabled modern HSI techniques. Presented also are recent applications of HSI for basic and applied eye research, which include a novel method for assessing dry eye syndrome, clinical slit-lamp examination of corneal injury, measurement of blood oxygen saturation in retinal disease, molecular changes in macular degeneration, and detection of early stages of Alzheimer disease. The review also highlights work resulting from integration of HSI with other imaging tools such as optical coherence tomography and autofluorescence microscopy and discusses the adaptation of HSI for clinical work where eye motion is present. Here, we present the background and main findings from each of these reports along with specific references for additional details.
Collapse
Affiliation(s)
- James M Beach
- Center for Drug Design, College of Pharmacy, University of Minnesota, Minneapolis, Minnesota
| | - Madeeha Rizvi
- Center for Drug Design, College of Pharmacy, University of Minnesota, Minneapolis, Minnesota
| | - Caitlin B Lichtenfels
- Center for Drug Design, College of Pharmacy, University of Minnesota, Minneapolis, Minnesota
| | - Robert Vince
- Center for Drug Design, College of Pharmacy, University of Minnesota, Minneapolis, Minnesota
| | | |
Collapse
|
23
|
Pappelis K, Jansonius NM. Retinal Oxygen Delivery and Extraction in Ophthalmologically Healthy Subjects With Different Blood Pressure Status. Transl Vis Sci Technol 2022; 11:9. [PMID: 35119472 PMCID: PMC8819358 DOI: 10.1167/tvst.11.2.9] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To compare retinal oxygen delivery (DO2) and oxygen extraction (VO2) in ophthalmologically healthy subjects with different blood pressure (BP) status. Methods In this case-control study, we prospectively included 93 eyes of 93 subjects (aged 50-65 years) from a Dutch cohort (n = 167,000) and allocated them to four groups (low BP, normal BP [controls], treated arterial hypertension [AHT], untreated AHT). We estimated vascular calibers from fundus images and fractal dimension from optical coherence tomography angiography scans. We combined calibers, fractal dimension, BP, and intraocular pressure measurements in a proxy of retinal blood flow (RBF), using a Poiseuille-based model. We measured arterial and venous oxygen saturations (SaO2, SvO2) with a scanning laser ophthalmoscope. We calculated the DO2 and VO2 from the RBF, SaO2, and SvO2. We compared the DO2 and VO2 between groups and investigated the DO2-VO2 association. Results DO2 and VO2 were different between groups (P = 0.009, P = 0.036, respectively). In a post hoc analysis, the low BP group had lower DO2 than the untreated AHT group (P = 4.9 × 10-4). The low BP group and the treated AHT group had a lower VO2 than the untreated AHT group (P = 0.021 and P = 0.034, respectively). There was a significant DO2-VO2 correlation (Robs = 0.65, bobs = 0.51, P = 2.4 × 10-12). After correcting for shared measurement error, the slope was not significant. Conclusions The DO2 and VO2 were altered in ophthalmologically healthy subjects with different BP status. Future studies could elucidate whether these changes can explain the increased risk of ophthalmic pathologies in those subjects. Translational Relevance Understanding the baseline interplay between BP, retinal perfusion, and oxygenation allows for improved evaluation of retinal disease manifestation.
Collapse
Affiliation(s)
- Konstantinos Pappelis
- Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.,Graduate School of Medical Sciences (Research School of Behavioural and Cognitive Neurosciences), University of Groningen, Groningen, the Netherlands
| | - Nomdo M Jansonius
- Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.,Graduate School of Medical Sciences (Research School of Behavioural and Cognitive Neurosciences), University of Groningen, Groningen, the Netherlands
| |
Collapse
|
24
|
Karlsson RA, Olafsdottir OB, Helgadottir V, Belhadj S, Eliasdottir TS, Stefansson E, Hardarson SH. Automation improves repeatability of retinal oximetry measurements. PLoS One 2021; 16:e0260120. [PMID: 34914738 PMCID: PMC8675673 DOI: 10.1371/journal.pone.0260120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 11/02/2021] [Indexed: 11/19/2022] Open
Abstract
Purpose Retinal oximetry is a technique based on spectrophotometry where images are analyzed with software capable of calculating vessel oxygen saturation and vessel diameter. In this study, the effect of automation of measurements of retinal vessel oxygen saturation and vessel diameter is explored. Methods Until now, operators have had to choose each vessel segment to be measured explicitly. A new, automatic version of the software automatically selects the vessels once the operator defines a measurement area. Five operators analyzed image pairs from the right eye of 23 healthy subjects with semiautomated retinal oximetry analysis software, Oxymap Analyzer (v2.5.1), and an automated version (v3.0). Inter- and intra-operator variability was investigated using the intraclass correlation coefficient (ICC) between oxygen saturation measurements of vessel segments in the same area of the retina. Results For semiautomated saturation measurements, the inter-rater ICC was 0.80 for arterioles and venules. For automated saturation measurements, the inter-rater ICC was 0.97 for arterioles and 0.96 for venules. For semiautomated diameter measurements, the inter-rater ICC was 0.71 for arterioles and venules. For automated diameter measurements the inter-rater ICC was 0.97 for arterioles and 0.95 for venules. The inter-rater ICCs were different (p < 0.01) between the semiautomated and automated version in all instances. Conclusion Automated measurements of retinal oximetry values are more repeatable compared to measurements where vessels are selected manually.
Collapse
Affiliation(s)
- Robert Arnar Karlsson
- Faculty of Medicine, University of Iceland, Reykjavik, Iceland
- Faculty of Electrical and Computer Engineering, University of Iceland, Reykjavik, Iceland
- * E-mail:
| | - Olof Birna Olafsdottir
- Faculty of Medicine, University of Iceland, Reykjavik, Iceland
- The National University Hospital of Iceland, Reykjavik, Iceland
| | | | | | - Thorunn Scheving Eliasdottir
- The National University Hospital of Iceland, Reykjavik, Iceland
- Faculty of Nursing, University of Iceland, Reykjavik, Iceland
| | - Einar Stefansson
- Faculty of Medicine, University of Iceland, Reykjavik, Iceland
- The National University Hospital of Iceland, Reykjavik, Iceland
| | | |
Collapse
|