1
|
Moorthy VM, Rathnasami JD, Srivastava VM. Design Optimization and Characterization with Fabrication of Nanomaterials-Based Photo Diode Cell for Subretinal Implant Application. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:934. [PMID: 36903812 PMCID: PMC10005570 DOI: 10.3390/nano13050934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 02/28/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
An ultrathin nano photodiode array fabricated in a flexible substrate can be an ideal therapeutic replacement for degenerated photoreceptor cells damaged by Age-related Macula Degeneration (AMD) and Retinitis Pigmentosa (RP), such as retinal infections. Silicon-based photodiode arrays have been attempted as artificial retinas. Considering the difficulties caused by hard silicon subretinal implants, researchers have diverted their attention towards organic photovoltaic cells-based subretinal implants. Indium-Tin Oxide (ITO) has been a favorite choice as an anode electrode. A mix of poly(3-hexylthiophene) and [6,6]-phenyl C61-butyric acid methyleste (P3HT: PCBM) has been utilized as an active layer in such nanomaterial-based subretinal implants. Though encouraging results have been obtained during the trial of such retinal implants, the need to replace ITO with a suitable transparent conductive electrode will be a suitable substitute. Further, conjugated polymers have been used as active layers in such photodiodes and have shown delamination in the retinal space over time despite their biocompatibility. This research attempted to fabricate and characterize Bulk Hetero Junction (BHJ) based Nano Photo Diode (NPD) utilizing Graphene-polyethylene terephthalate (G-PET)/semiconducting Single-Wall Carbon Nano Tubes (s-SWCNT): fullerene (C60) blend/aluminium (Al) structure to determine the issues in the development of subretinal prosthesis. An effective design approach adopted in this analysis has resulted in developing an NPD with an Efficiency of 10.1% in a non-ITO-driven NPD structure. Additionally, the results show that the efficiency can be further improved by increasing active layer thickness.
Collapse
Affiliation(s)
- Vijai M. Moorthy
- Department of Electronic Engineering, Howard College, University of KwaZulu-Natal, Durban 4041, South Africa
| | - Joseph D. Rathnasami
- Department of Electronics and Instrumentation Engineering, Faculty of Engineering and Technology, Annamalai University, Chidambaram 608 002, India
| | - Viranjay M. Srivastava
- Department of Electronic Engineering, Howard College, University of KwaZulu-Natal, Durban 4041, South Africa
| |
Collapse
|
2
|
Titchener SA, Goossens J, Kvansakul J, Nayagam DAX, Kolic M, Baglin EK, Ayton LN, Abbott CJ, Luu CD, Barnes N, Kentler WG, Shivdasani MN, Allen PJ, Petoe MA. Estimating Phosphene Locations Using Eye Movements of Suprachoroidal Retinal Prosthesis Users. Transl Vis Sci Technol 2023; 12:20. [PMID: 36943168 PMCID: PMC10043502 DOI: 10.1167/tvst.12.3.20] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2023] Open
Abstract
Purpose Accurate mapping of phosphene locations from visual prostheses is vital to encode spatial information. This process may involve the subject pointing to evoked phosphene locations with their finger. Here, we demonstrate phosphene mapping for a retinal implant using eye movements and compare it with retinotopic electrode positions and previous results using conventional finger-based mapping. Methods Three suprachoroidal retinal implant recipients (NCT03406416) indicated the spatial position of phosphenes. Electrodes were stimulated individually, and the subjects moved their finger (finger based) or their eyes (gaze based) to the perceived phosphene location. The distortion of the measured phosphene locations from the expected locations (retinotopic electrode locations) was characterized with Procrustes analysis. Results The finger-based phosphene locations were compressed spatially relative to the expected locations all three subjects, but preserved the general retinotopic arrangement (scale factors ranged from 0.37 to 0.83). In two subjects, the gaze-based phosphene locations were similar to the expected locations (scale factors of 0.72 and 0.99). For the third subject, there was no apparent relationship between gaze-based phosphene locations and electrode locations (scale factor of 0.07). Conclusions Gaze-based phosphene mapping was achievable in two of three tested retinal prosthesis subjects and their derived phosphene maps correlated well with the retinotopic electrode layout. A third subject could not produce a coherent gaze-based phosphene map, but this may have revealed that their phosphenes were indistinct spatially. Translational Relevance Gaze-based phosphene mapping is a viable alternative to conventional finger-based mapping, but may not be suitable for all subjects.
Collapse
Affiliation(s)
- Samuel A Titchener
- Bionics Institute, East Melbourne, VIC, Australia
- Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia
| | - Jeroen Goossens
- Donders Institute for Brain Cognition and Behaviour, Radboudumc, the Netherlands
| | - Jessica Kvansakul
- Bionics Institute, East Melbourne, VIC, Australia
- Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia
| | - David A X Nayagam
- Bionics Institute, East Melbourne, VIC, Australia
- Department of Pathology, University of Melbourne, Victoria, Australia
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
| | - Maria Kolic
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
| | - Elizabeth K Baglin
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
| | - Lauren N Ayton
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
- Department of Optometry and Vision Sciences, University of Melbourne, Melbourne, VIC, Australia
| | - Carla J Abbott
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Chi D Luu
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Nick Barnes
- Data61, CSIRO, Canberra, ACT, Australia
- Research School of Engineering, Australian National University, ACT, Australia
| | - William G Kentler
- Department of Biomedical Engineering, University of Melbourne, Melbourne, VIC, Australia
| | - Mohit N Shivdasani
- Graduate School of Biomedical Engineering, University of New South Wales, Kensington, NSW, Australia
| | - Penelope J Allen
- Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, Melbourne, VIC, Australia
- Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, VIC, Australia
| | - Matthew A Petoe
- Bionics Institute, East Melbourne, VIC, Australia
- Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
3
|
Wang J, Zhao R, Li P, Fang Z, Li Q, Han Y, Zhou R, Zhang Y. Clinical Progress and Optimization of Information Processing in Artificial Visual Prostheses. SENSORS (BASEL, SWITZERLAND) 2022; 22:6544. [PMID: 36081002 PMCID: PMC9460383 DOI: 10.3390/s22176544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/22/2022] [Accepted: 08/26/2022] [Indexed: 06/15/2023]
Abstract
Visual prostheses, used to assist in restoring functional vision to the visually impaired, convert captured external images into corresponding electrical stimulation patterns that are stimulated by implanted microelectrodes to induce phosphenes and eventually visual perception. Detecting and providing useful visual information to the prosthesis wearer under limited artificial vision has been an important concern in the field of visual prosthesis. Along with the development of prosthetic device design and stimulus encoding methods, researchers have explored the possibility of the application of computer vision by simulating visual perception under prosthetic vision. Effective image processing in computer vision is performed to optimize artificial visual information and improve the ability to restore various important visual functions in implant recipients, allowing them to better achieve their daily demands. This paper first reviews the recent clinical implantation of different types of visual prostheses, summarizes the artificial visual perception of implant recipients, and especially focuses on its irregularities, such as dropout and distorted phosphenes. Then, the important aspects of computer vision in the optimization of visual information processing are reviewed, and the possibilities and shortcomings of these solutions are discussed. Ultimately, the development direction and emphasis issues for improving the performance of visual prosthesis devices are summarized.
Collapse
Affiliation(s)
- Jing Wang
- School of Information, Shanghai Ocean University, Shanghai 201306, China
- Key Laboratory of Fishery Information, Ministry of Agriculture, Shanghai 200335, China
| | - Rongfeng Zhao
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| | - Peitong Li
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| | - Zhiqiang Fang
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| | - Qianqian Li
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| | - Yanling Han
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| | - Ruyan Zhou
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| | - Yun Zhang
- School of Information, Shanghai Ocean University, Shanghai 201306, China
| |
Collapse
|