1
|
Kumar H, Guymer RH, Hodgson LA, Hadoux X, Jannaud M, van Wijngaarden P, Luu CD, Wu Z. Reticular Pseudodrusen: Impact of Their Presence and Extent on Local Rod Function in Age-Related Macular Degeneration. OPHTHALMOLOGY SCIENCE 2024; 4:100551. [PMID: 39161750 PMCID: PMC11331943 DOI: 10.1016/j.xops.2024.100551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 08/21/2024]
Abstract
Purpose To understand the spatial relationship between local rod-mediated visual function and reticular pseudodrusen (RPD) in eyes with large drusen. Design Retrospective cross-sectional study. Participants One eye with large drusen (>125 μm) each from 91 individuals with intermediate age-related macular degeneration, with and without RPD. Methods All participants underwent dark adaptation testing using a dark-adapted chromatic perimeter, where visual sensitivities were measured over 30 minutes of dark adaptation after photobleach. The rod intercept time (RIT; a measure of dynamic rod function) and pointwise sensitivity difference (PWSD; a relative measure of rod- compared with cone-mediated function) was determined at multiple retinal locations, and their association with the overall (central 20° × 20° region) and local (2° diameter region centered on the location tested) extent of RPD and drusen (quantified using multimodal imaging) was examined. Main Outcome Measures Association between overall and local extent of RPD and drusen with RIT and PWSD at each retinal location tested. Results In a multivariable analysis, delayed RIT was associated with an increasing overall (P < 0.001), but not local (P = 0.884), extent of RPD. In contrast, the increasing local (P < 0.001), but not overall (P = 0.475), extent of drusen was associated with delayed RIT. Furthermore, only an increasing overall extent of RPD (P < 0.001) was associated with reduced PWSD (or worse rod compared with cone function), but not the local extent of RPD and drusen, or overall extent of drusen (P ≥ 0.344). Conclusions Local rod-mediated function was associated with the overall, rather than local, extent of RPD in eyes with large drusen, suggesting that there may be widespread pathologic changes in eyes with RPD that account for this. Financial Disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Himeesh Kumar
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Department of Surgery (Ophthalmology), The University of Melbourne, Melbourne, Australia
| | - Robyn H. Guymer
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Department of Surgery (Ophthalmology), The University of Melbourne, Melbourne, Australia
| | - Lauren A.B. Hodgson
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
| | - Xavier Hadoux
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Department of Surgery (Ophthalmology), The University of Melbourne, Melbourne, Australia
| | - Maxime Jannaud
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
| | - Peter van Wijngaarden
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Department of Surgery (Ophthalmology), The University of Melbourne, Melbourne, Australia
| | - Chi D. Luu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Department of Surgery (Ophthalmology), The University of Melbourne, Melbourne, Australia
| | - Zhichao Wu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Department of Surgery (Ophthalmology), The University of Melbourne, Melbourne, Australia
| |
Collapse
|
2
|
Sinclair SH, Schwartz S. Diabetic retinopathy: New concepts of screening, monitoring, and interventions. Surv Ophthalmol 2024; 69:882-892. [PMID: 38964559 DOI: 10.1016/j.survophthal.2024.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 06/30/2024] [Accepted: 07/01/2024] [Indexed: 07/06/2024]
Abstract
The science of diabetes care has progressed to provide a better understanding of the oxidative and inflammatory lesions and pathophysiology of the neurovascular unit within the retina (and brain) that occur early in diabetes, even prediabetes. Screening for retinal structural abnormalities, has traditionally been performed by fundus examination or color fundus photography; however, these imaging techniques detect the disease only when there are sufficient lesions, predominantly hemorrhagic, that are recognized to occur late in the disease process after significant neuronal apoptosis and atrophy, as well as microvascular occlusion with alterations in vision. Thus, interventions have been primarily oriented toward the later-detected stages, and clinical trials, while demonstrating a slowing of the disease progression, demonstrate minimal visual improvement and modest reduction in the continued loss over prolonged periods. Similarly, vision measurement utilizing charts detects only problems of visual function late, as the process begins most often parafoveally with increasing number and progressive expansion, including into the fovea. While visual acuity has long been used to define endpoints of visual function for such trials, current methods reviewed herein are found to be imprecise. We review improved methods of testing visual function and newer imaging techniques with the recommendation that these must be utilized to discover and evaluate the injury earlier in the disease process, even in the prediabetic state. This would allow earlier therapy with ocular as well as systemic pharmacologic treatments that lower the and neuro-inflammatory processes within eye and brain. This also may include newer, micropulsed laser therapy that, if applied during the earlier cascade, should result in improved and often normalized retinal function without the adverse treatment effects of standard photocoagulation therapy.
Collapse
Affiliation(s)
| | - Stan Schwartz
- University of Pennsylvania Affiliate, Main Line Health System, USA
| |
Collapse
|
3
|
Pfau M, Jolly JK, Charng J, von der Emde L, Müller PL, Ansari G, Pfau K, Chen FK, Wu Z. Multicenter Normative Data for Mesopic Microperimetry. Invest Ophthalmol Vis Sci 2024; 65:27. [PMID: 39422918 PMCID: PMC11512566 DOI: 10.1167/iovs.65.12.27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Accepted: 09/19/2024] [Indexed: 10/19/2024] Open
Abstract
Purpose The purpose of this study was to provide a large, multi-center normative dataset for the Macular Integrity Assessment (MAIA) microperimeter and compare the goodness-of-fit and prediction interval calibration-error for a panel of hill-of-vision models. Methods Microperimetry examinations of healthy eyes from five independent study groups and one previously available dataset were included (1137 tests from 531 eyes of 432 participants [223 women and 209 men]). Linear mixed models (LMMs) were fitted to the data to obtain interpretable hill-of-vision models. A panel of regression models to predict normative data was compared using cross-validation with site-wise splits. The mean absolute error (MAE) and miscalibration area (area between the calibration curve and the ideal diagonal) were evaluated as the performance measures. Results Based on the parameters "participant age," "eccentricity from the fovea," "overlap with the central fixation target," and "eccentricity along the four principal meridians," a Bayesian mixed model had the lowest MAE (2.13 decibel [dB]; 95% confidence interval [CI] = 1.9-2.36 dB) and miscalibration area (0.13; 95% CI = 0.07-0.19). However, a parsimonious linear model provided a comparable MAE (2.17 dB; 95% CI = 1.93-2.4 dB) and a similar miscalibration area (0.14; 95% CI = 0.08-0.2). Conclusions Normal variations in visual sensitivity on mesopic microperimetry can be effectively explained by a linear model that includes age and eccentricity. The dataset and a code vignette are provided for estimating normative values across a large range of retinal locations, applicable to customized testing patterns.
Collapse
Affiliation(s)
- Maximilian Pfau
- Department of Ophthalmology, University Hospital Basel, Basel, Switzerland
- Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Jasleen K. Jolly
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, United Kingdom
| | - Jason Charng
- Centre of Ophthalmology and Visual Science (incorporating Lions Eye Institute), University of Western Australia, Perth, Australia
- Department of Optometry, School of Allied Health, University of Western Australia, Perth, Australia
| | | | - Philipp L. Müller
- Department of Ophthalmology, University of Bonn, Bonn, Germany
- Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom
- Makula Center, Südblick Eye Centers, Augsburg, Germany
| | - Georg Ansari
- Department of Ophthalmology, University Hospital Basel, Basel, Switzerland
- Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland
| | - Kristina Pfau
- Department of Ophthalmology, University Hospital Basel, Basel, Switzerland
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Fred K. Chen
- Centre of Ophthalmology and Visual Science (incorporating Lions Eye Institute), University of Western Australia, Perth, Australia
- Department of Optometry, School of Allied Health, University of Western Australia, Perth, Australia
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Zhichao Wu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
- Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| |
Collapse
|
4
|
Taylor LJ, Josan AS, Adeyoju D, Jolly JK, MacLaren RE. Exploring Scotopic Microperimetry as an Outcome Measure in Choroideremia. Transl Vis Sci Technol 2024; 13:29. [PMID: 39348136 PMCID: PMC11441449 DOI: 10.1167/tvst.13.9.29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 07/01/2024] [Indexed: 10/01/2024] Open
Abstract
Purpose Choroideremia is an X-linked outer retinal degeneration. Early symptoms include nyctalopia and progressive visual field loss, but visual acuity is preserved until late disease stages. Dark-adapted two-color fundus-controlled perimetry (also known as scotopic microperimetry) has been developed to enable spatial assessment of rod and cone photoreceptor function. This study explores the use of scotopic microperimetry in patients with choroideremia. Methods Twenty patients with choroideremia and 21 age-matched healthy controls completed visual acuity and scotopic microperimetry testing, which used the Scotopic Macular Integrity Assessment (S-MAIA) microperimeter. A subset of participants completed repeat scotopic testing to enable Bland-Altman repeatability analyses. Test reliability was assessed using fixation stability, fixation losses, and assessment of the rod-free zones. Pointwise sensitivity, mean sensitivity, and volume sensitivity indices were analyzed. Results False positive responses were the main source of poor test reliability, indicated by stimuli responses in the physiological blind spot and lack of rod-free mapping. Scotopic cyan and red sensitivities were significantly reduced in choroideremia participants (n = 17) compared to healthy controls (n = 16) (P < 0.01, Mann-Whitney U test). Scotopic cyan sensitivity was statistically lower than scotopic red sensitivity in both healthy controls and choroideremia (P < 0.01, Wilcoxon signed rank test). Interpretation of scotopic cyan-red differences should be used with caution due to high test-retest variability. Conclusions Scotopic microperimetry could be a useful outcome measure in patients with early choroideremia. Careful selection of test grid design and sensitivity indices is required. Translational Relevance Scotopic microperimetry may be a useful outcome measure in clinical trials for patients with early stage choroideremia.
Collapse
Affiliation(s)
- Laura J. Taylor
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Amandeep S. Josan
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Daniel Adeyoju
- Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Jasleen K. Jolly
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, UK
| | - Robert E. MacLaren
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| |
Collapse
|
5
|
Trinh M, Kalloniatis M, Khuu SK, Nivison-Smith L. Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting. Eye (Lond) 2024; 38:1827-1835. [PMID: 38499857 PMCID: PMC11229509 DOI: 10.1038/s41433-024-03033-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 01/22/2024] [Accepted: 03/08/2024] [Indexed: 03/20/2024] Open
Abstract
Visual fields under mesopic and scotopic lighting are increasingly being used for macular functional assessment. This review evaluates its statistical significance and clinical relevance, and the optimal testing protocol for early/intermediate age-related macular degeneration (AMD). PubMed and Embase were searched from inception to 14/05/2022. All quality assessments were performed according to GRADE guidelines. The primary outcome was global mean sensitivity (MS), further meta-analysed by: AMD classification scheme, device, test pattern, mesopic/scotopic lighting, stimuli size/chromaticity, pupil dilation, testing radius (area), background luminance, adaptation time, AMD severity, reticular pseudodrusen presence, and follow-up visit. From 1489 studies screened, 42 observational study results contributed to the primary meta-analysis. Supported by moderate GRADE certainty of the evidence, global MS was significantly reduced across all devices under mesopic and scotopic lighting with large effect size (-0.9 [-1.04, -0.75] Hedge's g, P < 0.0001). The device (P < 0.01) and lighting (P < 0.05) used were the only modifiable factors affecting global MS, whereby the mesopic MP-1 and MAIA produced the largest effect sizes and exceeded test-retest variabilities. Global MS was significantly affected by AMD severity (intermediate versus early AMD; -0.58 [-0.88, -0.29] Hedge's g or -2.55 [3.62, -1.47] MAIA-dB) and at follow-up visit (versus baseline; -0.62 [-0.84, -0.41] Hedge's g or -1.61[-2.69, -0.54] MAIA-dB). Magnitudes of retinal sensitivity changes in early/intermediate AMD are clinically relevant for the MP-1 and MAIA devices under mesopic lighting within the central 10° radius. Other factors including pupil dilation and dark adaptation did not significantly affect global MS in early/intermediate AMD.
Collapse
Affiliation(s)
- Matt Trinh
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
- School of Medicine (Optometry), Deakin University, Geelong, VIC, Australia
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Lisa Nivison-Smith
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia.
| |
Collapse
|
6
|
Simunovic MP, Mammo Z. Mechanisms of cone sensitivity loss in retinitis pigmentosa. Ophthalmic Physiol Opt 2024; 44:605-612. [PMID: 38351866 DOI: 10.1111/opo.13280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 01/10/2024] [Accepted: 01/14/2024] [Indexed: 04/08/2024]
Abstract
PURPOSE To explore the mechanisms of cone sensitivity loss in retinitis pigmentosa by combining two-colour perimetry with threshold versus intensity (tvi) testing. METHODS Seven subjects with autosomal recessive retinitis pigmentosa and 10 normal subjects were recruited and underwent perimetric testing of one eye using 480- and 640-nm Goldman size V targets presented under scotopic conditions (no background illumination) and against a white background ranging in luminance from -1.5 to 2 log cd m-2 in 0.5 log cd m-2 steps. Data were fitted with tvi functions of the form logT = logT0 + log ((A + A0)/A0)n, where T is the threshold, T0 is the absolute threshold, A is the background intensity, A0 is the 'dark-light' constant and n is a gain constant. RESULTS Reliable tvi functions could not be obtained within the region of the visual field corresponding to loss of the ellipsoid zone on optical coherence tomography. At fixation, changes in both T0 and A0 were observed, consistent with a d1 mechanism loss, which resulted in an upwards and rightwards shift of the tvi function. Losses at [±3°, ±3°] demonstrated changes in T0, consistent with a d3 mechanism loss, resulting in an upwards translation of the tvi curve. CONCLUSIONS Although the absolute cone threshold was elevated at each location, shifts in the tvi function (so-called d1 mechanism loss) at fixation minimise threshold elevation in the presence of white adapting backgrounds, such as those typically employed in standard two-colour perimetry. At more peripheral testing locations, changes in threshold occurred independent of background luminance (so-called d3 mechanism loss). These findings suggest that backgrounds which selectively adapt rods while maintaining cones at, or near, absolute threshold may be preferable to conventional two-colour perimetry for assessing loss of cone sensitivity, especially at the point of fixation.
Collapse
Affiliation(s)
- Matthew P Simunovic
- Save Sight Institute, University of Sydney, Sydney, New South Wales, Australia
- Retinal Unit, Sydney Eye Hospital, Sydney, New South Wales, Australia
| | - Zaid Mammo
- Save Sight Institute, University of Sydney, Sydney, New South Wales, Australia
- Retinal Unit, Sydney Eye Hospital, Sydney, New South Wales, Australia
| |
Collapse
|
7
|
Coulibaly LM, Mohamed H, Fuchs P, Schmidt-Erfurth U, Reiter GS. Inter and intradevice assessment of microperimetry testing in aging eyes. Sci Rep 2024; 14:1049. [PMID: 38200267 PMCID: PMC10781777 DOI: 10.1038/s41598-024-51539-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 01/06/2024] [Indexed: 01/12/2024] Open
Abstract
Microperimetry (MP) is a psychometric examination combining retinal imaging and functional sensitivity testing with an increasing importance due to its potential use as clinical study outcome. We investigated the repeatability of pointwise retinal sensitivity (PWS) on the most advanced commercially available MP devices under their standard setting in a healthy aging population. Two successive MP examinations on both MP-3 (NIDEK CO., Ltd., Gamagori, Japan) and MAIA (CenterVue S.p.A. (iCare), Padova, Italy) were performed on healthy aging subjects in a randomized order. PWS repeatability was analysed for different macular regions and age groups using Bland-Altmann coefficients of repeatability (CoR). A total of 3600 stimuli from 20 healthy individuals with a mean age of 70 (11) years were included. Mean CoR in dB were ±4.61 for MAIA and ±4.55 for MP-3 examinations. A lower repeatability (p=0.005) was detected in the central millimetre on MAIA examinations. Higher subject age was associated with a lower repeatability of PWS on both devices (both p=0.003). Intra-device correlation was good (MAIA: 0.79 [0.76-0.81]; MP-3: 0.72 [0.68-0.76]) whereas a moderate mean inter-device correlation (0.6 [0.55-0.65]) could be detected. In conclusion, older subjects and the foveal region are associated with a worse pointwise repeatability.
Collapse
Affiliation(s)
- Leonard M Coulibaly
- Department of Ophthalmology and Optometry, Vienna Clinical Trial Centre (VTC), Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Hamza Mohamed
- Laboratory for Ophthalmic Image Analysis, Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| | - Philipp Fuchs
- Department of Ophthalmology and Optometry, Vienna Clinical Trial Centre (VTC), Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Ursula Schmidt-Erfurth
- Department of Ophthalmology and Optometry, Vienna Clinical Trial Centre (VTC), Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
- Laboratory for Ophthalmic Image Analysis, Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.
| | - Gregor S Reiter
- Laboratory for Ophthalmic Image Analysis, Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
8
|
Phu J, Wang H, Kalloniatis M. Comparing a head-mounted virtual reality perimeter and the Humphrey Field Analyzer for visual field testing in healthy and glaucoma patients. Ophthalmic Physiol Opt 2024; 44:83-95. [PMID: 37803502 PMCID: PMC10952716 DOI: 10.1111/opo.13229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 08/16/2023] [Accepted: 08/23/2023] [Indexed: 10/08/2023]
Abstract
PURPOSE To compare clinical visual field outputs in glaucoma and healthy patients returned by the Humphrey Field Analyzer (HFA) and virtual reality (Virtual Field, VF) perimetry. METHODS One eye of 54 glaucoma patients and 41 healthy subjects was prospectively tested (three times each in random order) using the HFA and VF perimeters (24-2 test grids). We extracted and compared global indices (mean deviation [MD] and pattern standard deviation [PSD]), pointwise sensitivity (and calculated 'equivalent' sensitivity after accounting for differences in background luminance) and pointwise defects. Bland-Altman (mean difference [Mdiff ] and 95% limits of agreement [LoA]) and intraclass correlation analyses were performed. RESULTS The VF test was shorter (by 76 s) and had lower fixation losses (by 0.08) and false-positive rate (by 0.01) compared to the HFA (all p < 0.0001). Intraclass correlations were 0.86, 0.82 and 0.47 for MD, PSD and pointwise sensitivity between devices, respectively. Test-retest variability was higher for VF (Mdiff 0.3 dB, LoA -7.6 to 8.2 dB) compared to the HFA (Mdiff -0.3 dB, LoA -6.4 to 5.9 dB), indicating greater test-retest variability. When using each device's underlying normative database, the HFA detected, on average, 7 more defects (at the p < 0.05 level) out of the 52 test locations compared to this iteration of VF in the glaucoma cohort. CONCLUSIONS Virtual Field returns global results that are correlated with the HFA, but pointwise sensitivities were more variable. Differences in test-retest variability and defect detection by its current normative database raise questions about the widespread adoption of VF in lieu of the HFA.
Collapse
Affiliation(s)
- Jack Phu
- School of Optometry and Vision ScienceUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- Centre for Eye HealthUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- Faculty of Medicine and HealthUniversity of SydneyCamperdownNew South WalesAustralia
- Concord Clinical SchoolConcord Repatriation General HospitalConcordNew South WalesAustralia
- School of Medicine (Optometry)Deakin UniversityWaurn PondsVictoriaAustralia
| | - Henrietta Wang
- School of Optometry and Vision ScienceUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- Centre for Eye HealthUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
| | - Michael Kalloniatis
- School of Optometry and Vision ScienceUniversity of New South Wales SydneyKensingtonNew South WalesAustralia
- School of Medicine (Optometry)Deakin UniversityWaurn PondsVictoriaAustralia
| |
Collapse
|
9
|
Trinh M, Kalloniatis M, Alonso-Caneiro D, Nivison-Smith L. Spatial Cluster Patterns of Retinal Sensitivity Loss in Intermediate Age-Related Macular Degeneration Features. Transl Vis Sci Technol 2023; 12:6. [PMID: 37676679 PMCID: PMC10494986 DOI: 10.1167/tvst.12.9.6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 07/20/2023] [Indexed: 09/08/2023] Open
Abstract
Purpose To examine spatial patterns of retinal sensitivity loss in the three key features of intermediate age-related macular degeneration (iAMD). Methods One-hundred individuals (53 iAMD, 47 normal) underwent 10-2 mesopic microperimetry testing in one eye. Pointwise sensitivities (dB) were corrected for age, sex, iAMD status, and co-presence of co-localized key iAMD features: drusen load, pigmentary abnormalities, and reticular pseudodrusen (RPD). Clusters (labeled by ranks of magnitude C-2, C-1, C0) were derived from pointwise sensitivities and then assessed by quadrants and eccentricity/rings. Results Two clusters of decreased sensitivities were evident in iAMD versus normal: C-2, -1.67 dB (95% CI (confidence intervals), -2.36 to -0.98; P < 0.0001); C-1, -0.93 dB (95% CI, -1.5 to -0.36; P < 0.01). One cluster of decreased sensitivity was independently associated each with increased drusen load (13.57 µm increase per -1 dB; P < 0.0001), pigmentary abnormalities (C-1: -2.23 dB; 95% CI, -3.36 to -1.1; P < 0.01), and RPD (C-1: -1.07 dB; 95% CI, -2 to -0.14; P < 0.01). Sensitivity loss in iAMD was biased toward the superior and central macula (P = 0.16 to <0.0001), aligning with structural distributions of features. However, sensitivity loss associated with drusen load also extended to the peripheral macula (P < 0.0001) with paracentral sparing, which was discordant with the central distribution of drusen. Conclusions Drusen load, pigmentary abnormalities, and RPD are associated with patterns of retinal sensitivity loss commonly demonstrating superior and central bias. Results highlighted that a clinical focus on these three key iAMD features using structural measures alone does not capture the complex, spatial extent of vision-related functional impairment in iAMD. Translational Relevance Defining the spatial patterns of retinal sensitivity loss in iAMD can facilitate a targeted visual field protocol for iAMD assessment.
Collapse
Affiliation(s)
- Matt Trinh
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
- School of Medicine (Optometry), Deakin University, Geelong, Victoria, Australia
| | - David Alonso-Caneiro
- School of Science, Technology and Engineering, University of Sunshine Coast, Queensland, Australia
| | - Lisa Nivison-Smith
- Centre for Eye Health, University of New South Wales, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
10
|
Hunter AML, Anderson RS, Redmond T, Garway-Heath DF, Mulholland PJ. Investigating the linkage between mesopic spatial summation and variations in retinal ganglion cell density across the central visual field. Ophthalmic Physiol Opt 2023; 43:1179-1189. [PMID: 37118942 DOI: 10.1111/opo.13158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 03/29/2023] [Accepted: 04/17/2023] [Indexed: 04/30/2023]
Abstract
PURPOSE The relationship between perimetric stimulus area and Ricco's area (RA) determines measured thresholds and the sensitivity of perimetry to retinal disease. The nature of this relationship, in addition to effect of retinal ganglion cell (RGC) number on this, is currently unknown for the adaptation conditions of mesopic microperimetry. In this study, achromatic mesopic spatial summation was measured across the central visual field to estimate RA with the number of RGCs underlying RA also being established. METHODS Achromatic luminance thresholds were measured for six incremental spot stimuli (0.009-2.07 deg2 ) and 190.4 ms duration, at four locations, each at 2.5°, 5° and 10° eccentricity in five healthy observers (mean age 61.4 years) under mesopic conditions (background 1.58 cd/m2 ). RA was estimated using two-phase regression analysis with the number of RGCs underlying RA being calculated using normative histological RGC counts. RESULTS Ricco's area exhibited a small but statistically insignificant increase between 2.5° and 10° eccentricity. Compared with photopic conditions, RA was larger, with the difference between RA and the Goldmann III stimulus (0.43°) being minimised. RGC number underlying RA was also higher than reported for photopic conditions (median 70 cells, IQR 36-93), with no significant difference being observed across test locations. CONCLUSIONS Ricco's area and the number of RGCs underlying RA do not vary significantly across the central visual field in mesopic conditions. However, RA is larger and more similar to the standard perimetric Goldmann III stimulus under mesopic compared with photopic adaptation conditions. Further work is required to determine if compensatory enlargements in RA occur in age-related macular degeneration, to establish the optimal stimulus parameters for AMD-specific microperimetry.
Collapse
Affiliation(s)
- Aoife M L Hunter
- Centre for Optometry and Vision Science, Biomedical Sciences Research Institute, Ulster University, Coleraine, UK
| | - Roger S Anderson
- Centre for Optometry and Vision Science, Biomedical Sciences Research Institute, Ulster University, Coleraine, UK
- National Institute for Health Research (NIHR) Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and University College London Institute of Ophthalmology, London, UK
| | - Tony Redmond
- School of Optometry & Vision Sciences, Cardiff University, Cardiff, UK
| | - David F Garway-Heath
- National Institute for Health Research (NIHR) Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and University College London Institute of Ophthalmology, London, UK
| | - Pádraig J Mulholland
- Centre for Optometry and Vision Science, Biomedical Sciences Research Institute, Ulster University, Coleraine, UK
- National Institute for Health Research (NIHR) Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and University College London Institute of Ophthalmology, London, UK
| |
Collapse
|
11
|
Jolly JK, Nanda A, Buckley TMW, Pfau M, Bridge H, MacLaren RE. Assessment of Scotopic Function in Rod-Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment. Transl Vis Sci Technol 2023; 12:10. [PMID: 36749581 PMCID: PMC9919682 DOI: 10.1167/tvst.12.2.10] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Purpose The scotopic macular integrity assessment (S-MAIA) can perform scotopic assessment to detect localized changes to scotopic rod and cone function. This study is an exploratory investigation of the feasibility of using the S-MAIA in a rod-cone dystrophy population to identify the pattern of loss in scotopic photoreceptor function. Methods Twenty patients diagnosed with a rod-cone dystrophy underwent visual acuity testing, full-field stimulus threshold assessment, and multiple S-MAIA tests after dark adaptation periods of 20 minutes and 45 minutes performed separately. Only right eyes were tested. Three tests were performed following a learning test. A Bland-Altman analysis was used to assess repeatability and agreement between tests after the two time periods. Spatial interpolation maps were created from the group plots to display the pattern of rod and cone loss. Results Learning effects took place between testing sessions 1 and 2 but not 2 and 3. Limits of agreement were larger in the patient eyes than control eyes, but within previously reported values. Using longer adaptation time of 45 minutes did not offer a significant advantage over 20 minutes. Patterns for the cyan and red sensitivities were different, indicating different patterns of loss for rods and cones. Conclusions A dark adaptation time of 20 minutes before testing is sufficient for thresholding. The S-MAIA is suitable for use in patients with a logarithm of the minimum angle of resolution vision of at least 0.7 and provides a viable outcome measure for patients with rod-cone dystrophies and preserved central vision. The spatial information about scotopic function from the S-MAIA provides information about disease processes and progression. Translational Relevance There is a need for scotopic measures for use in clinical trials. Scotopic microperimetry works well in patients with early disease, allowing the extension of recruitment criteria for novel therapies of rod-cone dystrophies.
Collapse
Affiliation(s)
- Jasleen K. Jolly
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK,Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK,Oxford Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, UK,Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, UK
| | - Anika Nanda
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK,Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Thomas M. W. Buckley
- Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany,Ophthalmic Genetics and Visual Function Branch, National Eye Institute, National Institutes of Health, Bethesda, MD, USA
| | - Holly Bridge
- Oxford Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, UK
| | - Robert E. MacLaren
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK,Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| |
Collapse
|
12
|
Kumar H, Guymer RH, Hodgson LAB, Hadoux X, Wu Z. Exploring Reticular Pseudodrusen Extent and Impact on Mesopic Visual Sensitivity in Intermediate Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci 2022; 63:14. [PMID: 35704305 PMCID: PMC9206392 DOI: 10.1167/iovs.63.6.14] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Purpose To explore the impact of the extent of reticular pseudodrusen (RPD) on mesopic visual sensitivity in individuals with intermediate age-related macular degeneration (AMD). Methods In total, 570 eyes from 285 participants with bilateral large drusen underwent microperimetry testing to assess the visual sensitivity of the central 3.6-mm region and multimodal imaging to determine the extent of RPD in the central 20° × 20° region (at the eye level). Mean visual sensitivity within five sectors in the central 3.6-mm region sampled on microperimetry and the extent of RPD in these sectors were derived. Linear mixed models were used to examine the association between the extent of RPD on overall mean visual sensitivity and sector-based mean sensitivity. Results An increasing extent of RPD at the eye level and within sectors was associated with a significant reduction in overall and sector-based mean sensitivity, respectively (P < 0.001 for both). However, when both RPD parameters were considered together in a multivariable model, only an increasing extent of RPD at the eye level (P < 0.001) and not within each sector (P = 0.178) was independently associated with reduced sector-based mean sensitivity. Conclusions Mesopic visual sensitivity is generally reduced in eyes with large drusen and coexistent RPD compared to eyes without RPD, with greater reductions with an increasing extent of RPD. However, reduced sector-based visual sensitivities are explained by the overall extent of RPD present, rather than their extent within the sector itself. These findings suggest that there are generalized pathogenic changes in eyes with RPD accounting for the observed mesopic visual dysfunction.
Collapse
Affiliation(s)
- Himeesh Kumar
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Robyn H Guymer
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Lauren A B Hodgson
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
| | - Xavier Hadoux
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Zhichao Wu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.,Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| |
Collapse
|
13
|
Abstract
Macular telangiectasia—which is associated with loss of the Müller cells, which in turn have a crucial role in the cone visual cycle—results in impaired cone photopigment regeneration kinetics and significantly elevated cone and rod thresholds. To test the hypothesis that Müller cell dysfunction in macular telangiectasia type 2 (MacTel) results in delayed cone adaptation kinetics and to assess absolute cone and rod thresholds in this condition.
Collapse
|
14
|
Raming K, Gliem M, Charbel Issa P, Birtel J, Herrmann P, Holz FG, Pfau M, Hess K. Visual Dysfunction and Structural Correlates in Sorsby Fundus Dystrophy. Am J Ophthalmol 2022; 234:274-284. [PMID: 34352251 DOI: 10.1016/j.ajo.2021.07.032] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Revised: 07/26/2021] [Accepted: 07/27/2021] [Indexed: 11/19/2022]
Abstract
PURPOSE To elucidate morphological determinants of rod and cone dysfunction in Sorsby fundus dystrophy (SFD), and to systematically compare visual function tests for interventional trials. DESIGN Prospective cross-sectional study. METHODS Patients with SFD (n = 16) and controls (n = 20) underwent visual function testing (best-corrected visual acuity [BCVA] and low luminance visual acuity [LLVA], contrast sensitivity, mesopic and dark-adapted (DA) fundus-controlled perimetry [FCP], rod-mediated dark adaptation [RMDA]), and multimodal imaging. Vision-related quality of life was evaluated. FCP and RMDA thresholds were analyzed using mixed models and structure-function correlation using machine learning (ML). Longitudinal data of 1 patient with high-dose vitamin A supplementation were available. RESULTS Although photopic BCVA was normative in SFD, LLVA was impaired (0.30 LogMAR [0.20; 0.45] vs 0.20 LogMAR [0.03; 0.28], P < .05). Scotopic visual function exhibited a delayed rod-intercept time (21 minutes [12.15; 21] vs 4.05 minutes [3.22; 5.36], P < .001), and marked DA cyan mean sensitivity loss (-11.80 dB [-3.47; -19.85]), paralleled by a reduced vision-related quality of life. ML-based structure-function correlation allowed prediction of mesopic, DA cyan, and red sensitivity with high accuracy (cross-validated mean absolute error: 4.36, 7.77, and 5.31 dB, respectively), whereas RMDA could be slowed even in the absence of fundus alterations on multimodal imaging. After high-dose vitamin A supplementation, RMDA and DA thresholds improved markedly. CONCLUSIONS Patients with SFD exhibit severely impaired scotopic visual function even in the absence of funduscopic alterations on multimodal imaging. In contrast to BCVA, scotopic visual function tests are suitable to quantify dysfunction in the early stages. Improvement of scotopic dysfunction after (off-label) high-dose vitamin A intake, as observed in one patient in our study, is compatible with the hypothesized local deficiency of vitamin A secondary to Bruch's membrane alterations.
Collapse
Affiliation(s)
- Kristin Raming
- From the Department of Ophthalmology (K.R., J.B., P.H., F.G.H., M.P., K.H.), University of Bonn, Bonn, Germany; Center for Rare Diseases (K.R., P.H., F.G.H., K.H.), University of Bonn, Bonn, Germany
| | - Martin Gliem
- Boehringer Ingelheim GmbH (M.G.), Ingelheim am Rhein, Germany
| | - Peter Charbel Issa
- Oxford Eye Hospital (P.C.I., J.B.,), Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom; Nuffield Laboratory of Ophthalmology (P.C.I., J.B.), Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Johannes Birtel
- From the Department of Ophthalmology (K.R., J.B., P.H., F.G.H., M.P., K.H.), University of Bonn, Bonn, Germany; Oxford Eye Hospital (P.C.I., J.B.,), Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom; Nuffield Laboratory of Ophthalmology (P.C.I., J.B.), Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Philipp Herrmann
- From the Department of Ophthalmology (K.R., J.B., P.H., F.G.H., M.P., K.H.), University of Bonn, Bonn, Germany; Center for Rare Diseases (K.R., P.H., F.G.H., K.H.), University of Bonn, Bonn, Germany
| | - Frank G Holz
- From the Department of Ophthalmology (K.R., J.B., P.H., F.G.H., M.P., K.H.), University of Bonn, Bonn, Germany; Center for Rare Diseases (K.R., P.H., F.G.H., K.H.), University of Bonn, Bonn, Germany
| | - Maximilian Pfau
- From the Department of Ophthalmology (K.R., J.B., P.H., F.G.H., M.P., K.H.), University of Bonn, Bonn, Germany; Ophthalmic Genetics and Visual Function Branch (M.P.), National Eye Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kristina Hess
- From the Department of Ophthalmology (K.R., J.B., P.H., F.G.H., M.P., K.H.), University of Bonn, Bonn, Germany; Center for Rare Diseases (K.R., P.H., F.G.H., K.H.), University of Bonn, Bonn, Germany; Division of Epidemiology and Clinical Applications (K.H.), National Eye Institute, National Institutes of Health, Bethesda, Maryland, USA.
| |
Collapse
|
15
|
Taylor LJ, Josan AS, Pfau M, Simunovic MP, Jolly JK. Scotopic microperimetry: evolution, applications and future directions. Clin Exp Optom 2022; 105:793-800. [PMID: 35025727 DOI: 10.1080/08164622.2021.2023477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
For many inherited and acquired retinal diseases, reduced night vision is a primary symptom. Despite this, the clinical testing options for spatially resolved scotopic vision have until recently been limited. Scotopic microperimetry is a relatively new visual function test that combines two-colour perimetry with fundus-controlled perimetry performed in scotopic luminance conditions. The technique enables spatially resolved mapping of central retinal sensitivity alongside the ability to distinguish between rod and cone photoreceptor sensitivities. Two companies produce commercially available scotopic microperimeters - Nidek (Nidek Technologies Srl, Padova, Italy) and CenterVue (CenterVue S.p.A., Padova, Italy). Scotopic microperimetry is a promising technology capable of detecting changes in retinal sensitivity before changes in other measures of visual function. Scotopic microperimetry is a promising functional biomarker that has the potential as a useful clinical trial outcome measure. This review summarises the evolution and applications of scotopic microperimetry, and discusses testing options, including testing grid selection, dark-adaptation time and threshold sensitivity analyses.
Collapse
Affiliation(s)
- Laura J Taylor
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Amandeep S Josan
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Maximilian Pfau
- Ophthalmic Genetics and Visual Function Branch, National Eye Institute, National Institutes of Health, Bethesda, MD, USA
| | - Matthew P Simunovic
- Save Sight Institute, Discipline of Ophthalmology, University of Sydney, Sydney, Australia
| | - Jasleen K Jolly
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.,Vision and Eye Research Institute, Anglia Ruskin University Medical School, Cambridge, UK
| |
Collapse
|
16
|
Simunovic MP, Grigg J, Mahroo O. Vision at the limits: absolute threshold, visual function, and outcomes in clinical trials. Surv Ophthalmol 2022; 67:1270-1286. [DOI: 10.1016/j.survophthal.2022.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 01/20/2022] [Accepted: 01/24/2022] [Indexed: 11/30/2022]
|
17
|
Wu Z, Fletcher EL, Kumar H, Greferath U, Guymer RH. Reticular pseudodrusen: A critical phenotype in age-related macular degeneration. Prog Retin Eye Res 2021; 88:101017. [PMID: 34752916 DOI: 10.1016/j.preteyeres.2021.101017] [Citation(s) in RCA: 65] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 10/07/2021] [Accepted: 10/29/2021] [Indexed: 12/18/2022]
Abstract
Reticular pseudodrusen (RPD), or subretinal drusenoid deposits (SDD), refer to distinct lesions that occur in the subretinal space. Over the past three decades, their presence in association with age-related macular degeneration (AMD) has become increasingly recognized, especially as RPD have become more easily distinguished with newer clinical imaging modalities. There is also an increasing appreciation that RPD appear to be a critical AMD phenotype, where understanding their pathogenesis will provide further insights into the processes driving vision loss in AMD. However, key barriers to understanding the current evidence related to the independent impact of RPD include the heterogeneity in defining their presence, and failure to account for the confounding impact of the concurrent presence and severity of AMD pathology. This review thus critically discusses the current evidence on the prevalence and clinical significance of RPD and proposes a clinical imaging definition of RPD that will help move the field forward in gathering further key knowledge about this critical phenotype. It also proposes a putative mechanism for RPD formation and how they may drive progression to vision loss in AMD, through examining current evidence and presenting novel findings from preclinical and clinical studies.
Collapse
Affiliation(s)
- Zhichao Wu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia; Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Erica L Fletcher
- Department of Anatomy and Physiology, The University of Melbourne, Melbourne, VIC, Australia
| | - Himeesh Kumar
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia; Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia
| | - Ursula Greferath
- Department of Anatomy and Physiology, The University of Melbourne, Melbourne, VIC, Australia
| | - Robyn H Guymer
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia; Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia.
| |
Collapse
|
18
|
Fars J, Pasutto F, Kremers J, Huchzermeyer C. Perifoveal Cone- and Rod-Mediated Temporal Contrast Sensitivities in Stargardt Disease/Fundus Flavimaculatus. Invest Ophthalmol Vis Sci 2021; 62:24. [PMID: 34807235 PMCID: PMC8626853 DOI: 10.1167/iovs.62.14.24] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to compare L-cone-driven, S-cone-driven, and rod-driven temporal contrast sensitivities (tCSs) in patients with Stargardt disease 1/fundus flavimaculatus (STGD1/FF). Methods Fourteen patients (eight male, six female; mean age, 43.21 ± 13.18 years) with genetically confirmed STGD1/FF participated in this study. A dedicated light-emitting diode stimulator was used to measure perifoveal tCSs in an annular test field (1°-6° of visual eccentricity) at temporal frequencies between 1 and 20 Hz. Photoreceptor classes were isolated with the triple silent substitution technique. To compare functional damage among photoreceptor classes, sensitivity deviations (decibels) were calculated based on age-related normal values and then averaged across those frequencies where perception is mediated by the same post-receptoral pathway (L-cone red-green opponent pathway: 1, 2, 4 Hz; luminance pathway: 12, 16, 20 Hz; S-cone pathway: 1, 2, 4 Hz; fast rod pathway: 8, 10, 12 Hz). Sensitivity deviations were compared with infrared scanning laser ophthalmoscopy (IR-SLO) and standard automated perimetry (SAP). Results Photoreceptor-driven tCSs were generally lower in patients with STGD1/FF than in normal subjects but were without systematic differences among photoreceptors. Although sensitivity deviations were significantly correlated between each other, only luminance-driven L-cone sensitivity deviations were significantly correlated with the IR-SLO area of hyporeflectance (AoH) and SAP central mean deviation within 6° eccentricity (MD6deg). Conclusions No systematic differences between photoreceptor classes were detected; however, our data suggest that temporal contrasts detected by the luminance pathway were closely correlated with other clinical parameters (AoH and MD6deg) and might be most useful as functional biomarkers in clinical trials.
Collapse
Affiliation(s)
- Julien Fars
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - Francesca Pasutto
- Institute of Human Genetics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Jan Kremers
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - Cord Huchzermeyer
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
19
|
Jolly JK, Simunovic MP, Dubis AM, Josan AS, Robson AG, Bellini MP, Bloch E, Georgiadis O, da Cruz L, Bridge H, MacLaren RE. Structural and Functional Characteristics of Color Vision Changes in Choroideremia. Front Neurosci 2021; 15:729807. [PMID: 34690675 PMCID: PMC8529211 DOI: 10.3389/fnins.2021.729807] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 09/08/2021] [Indexed: 12/01/2022] Open
Abstract
Color vision is considered a marker of cone function and its assessment in patients with retinal pathology is complementary to the assessments of spatial vision [best-corrected visual acuity (BCVA)] and contrast detection (perimetry). Rod-cone and chorioretinal dystrophies—such as choroideremia—typically cause alterations to color vision, making its assessment a potential outcome measure in clinical trials. However, clinical evaluation of color vision may be compromised by pathological changes to spatial vision and the visual field. The low vision Cambridge Color Test (lvCCT) was developed specifically to address these latter issues. We used the trivector version of the lvCCT to quantify color discrimination in a cohort of 53 patients with choroideremia. This test enables rapid and precise characterization of color discrimination along protan, deutan, and tritan axes more reliably than the historically preferred test for clinical trials, namely the Farnsworth Munsell 100 Hue test. The lvCCT demonstrates that color vision defects—particularly along the tritan axis—are seen early in choroideremia, and that this occurs independent of changes in visual acuity, pattern electroretinography and ellipsoid zone area on optical coherence tomography (OCT). We argue that the selective loss of tritan color discrimination can be explained by our current understanding of the machinery of color vision and the pathophysiology of choroideremia.
Collapse
Affiliation(s)
- Jasleen K Jolly
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.,Oxford Eye Hospital and NIHR Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom.,Oxford Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, United Kingdom
| | - Matthew P Simunovic
- Save Sight Institute, Discipline of Ophthalmology, University of Sydney, Sydney, NSW, Australia.,Retinal Unit Sydney Eye Hospital, Sydney, NSW, Australia
| | - Adam M Dubis
- NIHR Biomedical Resource Centre at Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, United Kingdom
| | - Amandeep S Josan
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.,Oxford Eye Hospital and NIHR Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Anthony G Robson
- Electrophysiology Department, Moorfields Eye Hospital, London, United Kingdom.,University College London Institute of Ophthalmology, London, United Kingdom
| | - Marco P Bellini
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Edward Bloch
- NIHR Biomedical Resource Centre at Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, United Kingdom
| | - Odysseas Georgiadis
- NIHR Biomedical Resource Centre at Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, United Kingdom
| | - Lyndon da Cruz
- NIHR Biomedical Resource Centre at Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, United Kingdom
| | - Holly Bridge
- Oxford Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, United Kingdom
| | - Robert E MacLaren
- Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.,Oxford Eye Hospital and NIHR Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| |
Collapse
|
20
|
Pfau M, van Dijk EHC, van Rijssen TJ, Schmitz-Valckenberg S, Holz FG, Fleckenstein M, Boon CJF. Estimation of current and post-treatment retinal function in chronic central serous chorioretinopathy using artificial intelligence. Sci Rep 2021; 11:20446. [PMID: 34650220 PMCID: PMC8516921 DOI: 10.1038/s41598-021-99977-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 07/30/2021] [Indexed: 01/13/2023] Open
Abstract
Refined understanding of the association of retinal microstructure with current and future (post-treatment) function in chronic central serous chorioretinopathy (cCSC) may help to identify patients that would benefit most from treatment. In this post-hoc analysis of data from the prospective, randomized PLACE trial (NCT01797861), we aimed to determine the accuracy of AI-based inference of retinal function from retinal morphology in cCSC. Longitudinal spectral-domain optical coherence tomography (SD-OCT) data from 57 eyes of 57 patients from baseline, week 6-8 and month 7-8 post-treatment were segmented using deep-learning software. Fundus-controlled perimetry data were aligned to the SD-OCT data to extract layer thickness and reflectivity values for each test point. Point-wise retinal sensitivity could be inferred with a (leave-one-out) cross-validated mean absolute error (MAE) [95% CI] of 2.93 dB [2.40-3.46] (scenario 1) using random forest regression. With addition of patient-specific baseline data (scenario 2), retinal sensitivity at remaining follow-up visits was estimated even more accurately with a MAE of 1.07 dB [1.06-1.08]. In scenario 3, month 7-8 post-treatment retinal sensitivity was predicted from baseline SD-OCT data with a MAE of 3.38 dB [2.82-3.94]. Our study shows that localized retinal sensitivity can be inferred from retinal structure in cCSC using machine-learning. Especially, prediction of month 7-8 post-treatment sensitivity with consideration of the treatment as explanatory variable constitutes an important step toward personalized treatment decisions in cCSC.
Collapse
Affiliation(s)
- Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany
- National Eye Institute, National Institutes of Health, Bethesda, MD, USA
| | - Elon H C van Dijk
- Department of Ophthalmology, Leiden University Medical Center, P. O. Box 9600, 2300 RC, Leiden, The Netherlands
| | - Thomas J van Rijssen
- Department of Ophthalmology, Leiden University Medical Center, P. O. Box 9600, 2300 RC, Leiden, The Netherlands
| | - Steffen Schmitz-Valckenberg
- Department of Ophthalmology, University of Bonn, Bonn, Germany
- John A. Moran Eye Center, University of Utah, Utah, USA
| | - Frank G Holz
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | | | - Camiel J F Boon
- Department of Ophthalmology, Leiden University Medical Center, P. O. Box 9600, 2300 RC, Leiden, The Netherlands.
- Department of Ophthalmology, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
| |
Collapse
|
21
|
Pfau M, Jolly JK, Wu Z, Denniss J, Lad EM, Guymer RH, Fleckenstein M, Holz FG, Schmitz-Valckenberg S. Fundus-controlled perimetry (microperimetry): Application as outcome measure in clinical trials. Prog Retin Eye Res 2021; 82:100907. [PMID: 33022378 DOI: 10.1016/j.preteyeres.2020.100907] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/20/2020] [Accepted: 09/23/2020] [Indexed: 02/06/2023]
Abstract
Fundus-controlled perimetry (FCP, also called 'microperimetry') allows for spatially-resolved mapping of visual sensitivity and measurement of fixation stability, both in clinical practice as well as research. The accurate spatial characterization of visual function enabled by FCP can provide insightful information about disease severity and progression not reflected by best-corrected visual acuity in a large range of disorders. This is especially important for monitoring of retinal diseases that initially spare the central retina in earlier disease stages. Improved intra- and inter-session retest-variability through fundus-tracking and precise point-wise follow-up examinations even in patients with unstable fixation represent key advantages of these technique. The design of disease-specific test patterns and protocols reduces the burden of extensive and time-consuming FCP testing, permitting a more meaningful and focused application. Recent developments also allow for photoreceptor-specific testing through implementation of dark-adapted chromatic and photopic testing. A detailed understanding of the variety of available devices and test settings is a key prerequisite for the design and optimization of FCP protocols in future natural history studies and clinical trials. Accordingly, this review describes the theoretical and technical background of FCP, its prior application in clinical and research settings, data that qualify the application of FCP as an outcome measure in clinical trials as well as ongoing and future developments.
Collapse
Affiliation(s)
- Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany; Department of Biomedical Data Science, Stanford University, Stanford, USA
| | - Jasleen Kaur Jolly
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Zhichao Wu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia; Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Victoria, Australia
| | | | - Eleonora M Lad
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | - Robyn H Guymer
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia; Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Victoria, Australia
| | | | - Frank G Holz
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Steffen Schmitz-Valckenberg
- Department of Ophthalmology, University of Bonn, Bonn, Germany; John A. Moran Eye Center, University of Utah, USA.
| |
Collapse
|
22
|
Hess K, Gliem M, Charbel Issa P, Birtel J, Müller PL, von der Emde L, Herrmann P, Holz FG, Pfau M. Mesopic and Scotopic Light Sensitivity and Its Microstructural Correlates in Pseudoxanthoma Elasticum. JAMA Ophthalmol 2021; 138:1272-1279. [PMID: 33090206 DOI: 10.1001/jamaophthalmol.2020.4335] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Importance Correlates for Bruch membrane alterations are needed for interventional trials targeting the Bruch membrane in pseudoxanthoma elasticum (PXE). Objectives To quantify mesopic and scotopic light sensitivity and identify its microstructural correlates associated with a diseased Bruch membrane in patients with PXE. Design, Setting, and Participants A prospective, single-center, cross-sectional case-control study was conducted at a tertiary referral center from January 31, 2018, to February 20, 2020. Twenty-two eyes of 22 patients with PXE and 40 eyes of 40 healthy individuals were included. Data analysis was completed March 15, 2020. Exposures Mesopic and dark-adapted 2-color fundus-controlled perimetry (microperimetry) and multimodal retinal imaging including spectral-domain optical coherence tomography (SD-OCT) and OCT angiography were performed. Perimetry thresholds were analyzed using mixed models, and structure-function correlation with SD-OCT data was performed using machine learning. Main Outcomes and Measures Observed dark-adapted cyan sensitivity loss as measure of rod photoreceptor dysfunction, as well as mean absolute error between predicted and observed retinal sensitivity to assess the accuracy of structure-function correlation. Results Of the 22 patients with PXE included in this study, 15 were women (68%); median age was 56.5 years (interquartile range, 50.4-61.2). These patients exhibited mesopic (estimate, 5.13 dB; 95% CI, 2.89-7.38 dB), dark-adapted cyan (estimate, 9.08 dB; 95% CI, 6.34-11.82 dB), and dark-adapted red (estimate, 7.05 dB; 95% CI, 4.83-9.27 dB) sensitivity losses. This sensitivity loss was also evident in 9 eyes with nonneovascular PXE (mesopic: estimate, 3.21 dB; 95% CI, 1.28-5.14 dB; dark-adapted cyan: 5.93 dB; 95% CI, 3.59-8.27 dB; and dark-adapted red testing: 4.84 dB; 95% CI, 2.88-6.80 dB), showing a distinct centrifugal pattern of sensitivity loss with preserved function toward the periphery. Retinal function could be predicted from microstructure with high accuracy (mean absolute errors, of 4.91 dB for mesopic, 5.44 dB for dark-adapted cyan, and 4.99 dB for dark-adapted red). The machine learning-based analysis highlighted an association of a thinned inner retina and putative separation of the pigment-epithelium-photoreceptor complex with sensitivity loss. Conclusions and Relevance In this study, among 22 patients with PXE, those with and without choroidal neovascularization exhibited reductions of retinal sensitivity being most pronounced in dark-adapted cyan testing. This finding suggests that pathologic characteristics of this Bruch membrane disease may be dominated by rod photoreceptor degeneration and/or dysfunction. A putative pigment-epithelium-photoreceptor separation may further impair rod function, while inner retinal abnormalities appear to be correlated with overall dysfunction.
Collapse
Affiliation(s)
- Kristina Hess
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Center for Rare Diseases Bonn, University of Bonn, Bonn, Germany
| | - Martin Gliem
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,F. Hoffmann-La Roche Ltd, Basel, Switzerland
| | - Peter Charbel Issa
- Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom.,Nuffield Laboratory of Ophthalmology, Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Johannes Birtel
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Center for Rare Diseases Bonn, University of Bonn, Bonn, Germany.,Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom.,Nuffield Laboratory of Ophthalmology, Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Philipp L Müller
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Center for Rare Diseases Bonn, University of Bonn, Bonn, Germany.,Moorfields Eye Hospital National Health Service Foundation Trust, London, United Kingdom
| | | | - Philipp Herrmann
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Center for Rare Diseases Bonn, University of Bonn, Bonn, Germany
| | - Frank G Holz
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Center for Rare Diseases Bonn, University of Bonn, Bonn, Germany
| | - Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Department of Biomedical Data Science, Stanford University, Stanford, California
| |
Collapse
|
23
|
Stockman A, Henning GB, Rider AT. Clinical vision and molecular loss: Integrating visual psychophysics with molecular genetics reveals key details of normal and abnormal visual processing. Prog Retin Eye Res 2020; 83:100937. [PMID: 33388434 DOI: 10.1016/j.preteyeres.2020.100937] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2020] [Revised: 12/11/2020] [Accepted: 12/17/2020] [Indexed: 01/08/2023]
Abstract
Over the past two decades we have developed techniques and models to investigate the ways in which known molecular defects affect visual performance. Because molecular defects in retinal signalling invariably alter the speed of visual processing, our strategy has been to measure the resulting changes in flicker sensitivity. Flicker measurements provide not only straightforward clinical assessments of visual performance but also reveal fundamental details about the functioning of both abnormal and normal visual systems. Here, we bring together our past measurements of patients with pathogenic variants in the GNAT2, RGS9, GUCA1A, RPE65, OPA1, KCNV2 and NR2E3 genes and analyse the results using a standard model of visual processing. The model treats flicker sensitivity as the result of the actions of a sequence of simple processing steps, one or more of which is altered by the genetic defect. Our analyses show that most defects slow down the visual response directly, but some speed it up. Crucially, however, other steps in the processing sequence can make compensatory adjustments to offset the abnormality. For example, if the abnormal step slows down the visual response, another step is likely to speed up or attenuate the response to rebalance system performance. Such compensatory adjustments are probably made by steps in the sequence that usually adapt to changing light levels. Our techniques and modelling also allow us to tease apart stationary and progressive effects, and the localised molecular losses help us to unravel and characterise individual steps in the normal and abnormal processing sequences.
Collapse
Affiliation(s)
- Andrew Stockman
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9EL, England, UK.
| | - G Bruce Henning
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9EL, England, UK
| | - Andrew T Rider
- UCL Institute of Ophthalmology, 11-43 Bath Street, London, EC1V 9EL, England, UK
| |
Collapse
|
24
|
Simunovic MP, Hess K, Avery N, Mammo Z. Threshold versus intensity functions in two-colour automated perimetry. Ophthalmic Physiol Opt 2020; 41:157-164. [PMID: 33063858 DOI: 10.1111/opo.12743] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 08/31/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE Two-colour computerised perimetry is a technique developed for assessing cone- and rod-function at fixed background luminances in retinal disease. However, the state of adaptation during testing is unknown but crucial in the interpretation of results. We therefore aimed to determine the adaptational state of rod- and cone-mechanisms in two-colour perimetry. METHODS Sensitivity to 480 nm (blue) and 640 nm (red) Goldmann size V targets was determined for 10 normal subjects aged 16 to 46 years at 17 locations in the central 60 degrees of the visual field under scotopic conditions and then from -1.5 log cd m-2 to 2 log cd m-2 (white background) in 0.5 log unit steps. Data were fitted with threshold versus intensity (tvi) functions of the form logT = logT0 + log ((A + A0 )/A0 )n . RESULTS No clear rod-cone break was observed for 640 nm stimuli. For 480 nm stimuli, transition from rod-detection to cone-detection occurred at mesopic illumination levels, where rod adaptation approached Weber behaviour. Cone detection mechanisms did not display Weber-like adaptation until the background luminance approached 1 log cd.m-2 . Diseases resulting in a "filter effect" - including disorders of the photoreceptors - are therefore predicted to affect sensitivity when rod function is probed with short-wavelength targets under scotopic conditions, but less so under mesopic conditions. Filter effects are similarly anticipated to affect cone function measured using long-wavelength targets under mesopic conditions (e.g., during microperimetry), but less so under photopic conditions. CONCLUSIONS Asymmetries in adaptation in automated two-colour perimetry are predicted to artefactually favour the detection of losses in rod sensitivity under scotopic conditions and cones under mesopic conditions.
Collapse
Affiliation(s)
- Matthew P Simunovic
- Save Sight Institute, Discipline of Ophthalmology, University of Sydney, Sydney, Australia.,Retinal Unit, Sydney Eye Hospital, Sydney, Australia
| | - Kristina Hess
- Save Sight Institute, Discipline of Ophthalmology, University of Sydney, Sydney, Australia.,Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Neil Avery
- Retinal Unit, Sydney Eye Hospital, Sydney, Australia
| | - Zaid Mammo
- Retinal Unit, Sydney Eye Hospital, Sydney, Australia
| |
Collapse
|
25
|
Huchzermeyer C, Fars J, Kremers J. Photoreceptor-Specific Loss of Perifoveal Temporal Contrast Sensitivity in Retinitis Pigmentosa. Transl Vis Sci Technol 2020; 9:27. [PMID: 32821524 PMCID: PMC7409023 DOI: 10.1167/tvst.9.6.27] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 04/01/2020] [Indexed: 02/07/2023] Open
Abstract
Purpose Inherited retinal diseases affect the L-, M-, S-cones and rods in distinct ways, which calls for new methods that enable quantification of photoreceptor-specific functions. We tested the feasibility of using the silent substitution paradigm to estimate photoreceptor-driven temporal contrast sensitivity (tCS) functions in patients with retinitis pigmentosa. Methods The silent substitution paradigm is based on substitution of lights of different spectral composition; this offers considerable advantage over other stimulation techniques. We used a four-primary LED stimulator to create perifoveal annular stimuli (2° inner, 12° outer diameters) and used a triple silent substitution to probe photoreceptor-selective tCS. Measurements were performed in a heterogeneous cohort of 15 patients with retinitis pigmentosa and related to those in a control group of nine color-normal healthy observers. Age differences between groups were addressed with a model of age-related normal contrast sensitivity derived from measurements in 20 healthy observers aged between 23 and 83 years. Results The age-related loss of tCS amounted to 0.1 dB/year in healthy subjects across all photoreceptor subtypes. In patients, tCS was decreased for every photoreceptor subtype; however, S-cone- and rod-driven sensitivities were most strongly affected. Postreceptoral mechanisms were not affected. Conclusions This feasibility study provides evidence that the silent substitution technique enables the estimation of photoreceptor-selective tCS functions and can serve as an accurate biomarker of photoreceptor-specific contrast sensitivity loss in patients with retinitis pigmentosa. Translational Relevance We aim to develop tests of visual function for clinical trials of novel therapies for inherited retinal diseases from methods that can currently be used only in vision research labs.
Collapse
Affiliation(s)
- Cord Huchzermeyer
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - Julien Fars
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - Jan Kremers
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
26
|
MESOPIC AND DARK-ADAPTED TWO-COLOR FUNDUS-CONTROLLED PERIMETRY IN GEOGRAPHIC ATROPHY SECONDARY TO AGE-RELATED MACULAR DEGENERATION. Retina 2020; 40:169-180. [DOI: 10.1097/iae.0000000000002337] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
27
|
Abstract
PURPOSE To evaluate dark adaptation (DA) in patients with macular telangiectasia Type 2 (MacTel). METHODS After a local photobleach (4 × 4° size, 83% bleach), DA was measured using a test stimulus (2° diameter) projected at 5° eccentricity horizontal from the foveal center within the temporal parafovea. Cone plateau, rod intercept time, and rod recovery rate (S2) were calculated from the resulting DA curves. Findings were correlated with disease stages (according to Gass and Blodi), the area of ellipsoid zone loss in optical coherence tomography, and macular pigment loss ("MP-Classes 1-3"). RESULTS Fifty-nine eyes of 59 patients were compared with 18 eyes of 18 healthy controls. Dark adaptation was significantly impaired in patients with MacTel. Although differences were most pronounced for parameters indicating rod-mediated recovery, cone-mediated recovery was also decreased, yet to a lesser extent. Dark adaptation parameters were only weakly associated with disease stages and ellipsoid zone loss. A better association was found between rod-mediated recovery (S2 and rod intercept time) and macular pigment loss (Kendall's tau for rod intercept time: 0.69 and S2: -0.51; both P < 0.0001). CONCLUSION Dark adaptation is significantly impaired in patients with MacTel. Our results indicate an association of reduced macular pigment and rod dysfunction in MacTel.
Collapse
|
28
|
Heeren TFC, Tzaridis S, Bonelli R, Pfau M, Fruttiger M, Okada M, Egan C, Charbel Issa P, Holz FG. Dark-Adapted Two-Color Fundus-Controlled Perimetry in Macular Telangiectasia Type 2. ACTA ACUST UNITED AC 2019; 60:1760-1767. [DOI: 10.1167/iovs.18-25360] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Affiliation(s)
- Tjebo F. C. Heeren
- Department of Ophthalmology, University of Bonn, Bonn, Germany
- Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom
- UCL Institute of Ophthalmology, University College London, London, United Kingdom
| | - Simone Tzaridis
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Roberto Bonelli
- The Walter and Eliza Hall Institute of Medical Research, Parkville, Victoria, Australia
- Department of Medical Biology, University of Melbourne, Parkville, Victoria, Australia
| | - Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | - Marcus Fruttiger
- UCL Institute of Ophthalmology, University College London, London, United Kingdom
| | - Mali Okada
- Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia
| | - Catherine Egan
- Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom
- UCL Institute of Ophthalmology, University College London, London, United Kingdom
| | - Peter Charbel Issa
- Oxford Eye Hospital, Oxford University Hospital NHS Foundation Trust and the Nuffield Laboratory of Ophthalmology, Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Frank G. Holz
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| |
Collapse
|
29
|
Waugh N, Loveman E, Colquitt J, Royle P, Yeong JL, Hoad G, Lois N. Treatments for dry age-related macular degeneration and Stargardt disease: a systematic review. Health Technol Assess 2019; 22:1-168. [PMID: 29846169 DOI: 10.3310/hta22270] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Age-related macular degeneration (AMD) is the leading cause of visual loss in older people. Advanced AMD takes two forms, neovascular (wet) and atrophic (dry). Stargardt disease (STGD) is the commonest form of inherited macular dystrophy. OBJECTIVE To carry out a systematic review of treatments for dry AMD and STGD, and to identify emerging treatments where future NIHR research might be commissioned. DESIGN Systematic review. METHODS We searched MEDLINE, EMBASE, Web of Science and The Cochrane Library from 2005 to 13 July 2017 for reviews, journal articles and meeting abstracts. We looked for studies of interventions that aim to preserve or restore vision in people with dry AMD or STGD. The most important outcomes are those that matter to patients: visual acuity (VA), contrast sensitivity, reading speed, ability to drive, adverse effects of treatment, quality of life, progression of disease and patient preference. However, visual loss is a late event and intermediate predictors of future decline were accepted if there was good evidence that they are strong predictors of subsequent visual outcomes. These include changes detectable by investigation, but not necessarily noticed by people with AMD or STGD. ClinicalTrials.gov, the World Health Organization search portal and the UK Clinical Trials gateway were searched for ongoing and recently completed clinical trials. RESULTS The titles and abstracts of 7948 articles were screened for inclusion. The full text of 398 articles were obtained for further screening and checking of references and 112 articles were included in the final report. Overall, there were disappointingly few good-quality studies (including of sufficient size and duration) reporting useful outcomes, particularly in STGD. However we did identify a number of promising research topics, including drug treatments, stem cells, new forms of laser treatment, and implantable intraocular lens telescopes. In many cases, research is already under way, funded by industry or governments. LIMITATIONS In AMD, the main limitation came from the poor quality of much of the evidence. Many studies used VA as their main outcome despite not having sufficient duration to observe changes. The evidence on treatments for STGD is sparse. Most studies tested interventions with no comparison group, were far too short term, and the quality of some studies was poor. FUTURE WORK We think that the topics on which the Health Technology Assessment (HTA) and Efficacy Mechanism and Evaluation (EME) programmes might consider commissioning primary research are in STGD, a HTA trial of fenretinide (ReVision Therapeutics, San Diego, CA, USA), a visual cycle inhibitor, and EME research into the value of lutein and zeaxanthin supplements, using short-term measures of retinal function. In AMD, we suggest trials of fenretinide and of a potent statin. There is epidemiological evidence from the USA that the drug, levodopa, used for treating Parkinson's disease, may reduce the incidence of AMD. We suggest that similar research should be carried out using the large general practice databases in the UK. Ideally, future research should be at earlier stages in both diseases, before vision is impaired, using sensitive measures of macular function. This may require early detection of AMD by screening. STUDY REGISTRATION This study is registered as PROSPERO CRD42016038708. FUNDING The National Institute for Health Research HTA programme.
Collapse
Affiliation(s)
- Norman Waugh
- Division of Health Sciences, University of Warwick, Coventry, UK
| | | | | | - Pamela Royle
- Division of Health Sciences, University of Warwick, Coventry, UK
| | | | | | - Noemi Lois
- Ophthalmology, Royal Victoria Hospital, Belfast, UK.,Wellcome-Wolfson Centre for Experimental Medicine, Queens University, Belfast, UK
| |
Collapse
|
30
|
Csaky KG, Patel PJ, Sepah YJ, Birch DG, Do DV, Ip MS, Guymer RH, Luu CD, Gune S, Lin H, Ferrara D. Microperimetry for geographic atrophy secondary to age-related macular degeneration. Surv Ophthalmol 2019; 64:353-364. [PMID: 30703401 DOI: 10.1016/j.survophthal.2019.01.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Revised: 01/15/2019] [Accepted: 01/17/2019] [Indexed: 01/06/2023]
Abstract
Geographic atrophy (GA) is a progressive, advanced form of age-related macular degeneration leading to visual function impairment and irreversible vision loss. Standard clinical tests to evaluate visual function in patients with GA provide poor anatomic-functional correlation, whereas fundus imaging does not assess the visual function deficit. Microperimetry is a psychophysical visual function test that spatially maps retinal sensitivity and allows for identification of correlation of anatomic features with visual function. In this review, we present an overview of mesopic microperimetry for GA, including commercially available microperimetry devices, strategies to capture a mesopic microperimetry test, and strategies to assess and interpret microperimetry data in patients with GA. We demonstrate the importance of microperimetry data for assessing GA progression and for evaluating visual function loss through anatomic-functional correlations. Although valuable, current microperimetry tests require an extensive time commitment from the patient and examiner, and the development of faster, more reproducible and accessible methods is important to enable broader use of microperimetry in both clinical and research settings.
Collapse
Affiliation(s)
- Karl G Csaky
- Texas Retina Associates, Dallas, Texas, USA; Retina Foundation of the Southwest, Dallas, Texas, USA.
| | - Praveen J Patel
- NIHR Biomedical Research Centre at Moorfields Eye Hospital and UCL Institute of Ophthalmology, London, United Kingdom
| | - Yasir J Sepah
- Byers Eye Institute, Stanford University School of Medicine, Palo Alto, California, USA
| | - David G Birch
- Retina Foundation of the Southwest, Dallas, Texas, USA
| | - Diana V Do
- Byers Eye Institute, Stanford University School of Medicine, Palo Alto, California, USA
| | - Michael S Ip
- Doheny Eye Institute, Los Angeles, California, USA
| | - Robyn H Guymer
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital; Department of Surgery (Ophthalmology), University of Melbourne, Victoria, Australia
| | - Chi D Luu
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital; Department of Surgery (Ophthalmology), University of Melbourne, Victoria, Australia
| | - Shamika Gune
- Genentech, Inc., South San Francisco, California, USA
| | - Hugh Lin
- Genentech, Inc., South San Francisco, California, USA
| | | |
Collapse
|
31
|
Han RC, Gray JM, Han J, Maclaren RE, Jolly JK. Optimisation of dark adaptation time required for mesopic microperimetry. Br J Ophthalmol 2018; 103:1092-1098. [DOI: 10.1136/bjophthalmol-2018-312253] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 08/10/2018] [Accepted: 08/28/2018] [Indexed: 11/04/2022]
Abstract
BackgroundMacular Integrity Assessment (MAIA) microperimetry is increasingly used in clinical and research settings to assess point retinal sensitivity and fixation stability. Testing occurs under mesopic conditions, commonly after a period of dark adaptation. Our aim was to identify the minimum length of adaptation required to optimise microperimetry performance.MethodsMAIA microperimetry using the 10-2 grid was performed on 40 right eyes of 40 healthy participants aged 18–73 with no ocular pathology and vision of at least 0.1 logMAR after ambient light exposure, with 0, 5, 10, 15, 20 and 30 min of adaptation in mesopic settings. Ten right eyes of 10 participants with choroideremia were also tested following 0 and 20 min of adaptation. We further tested 10 right eyes of 10 healthy participants after bright light exposure, with 0, 10 and 20 min of adaptation. We compared changes in threshold sensitivity and fixation stability across time points.ResultsMicroperimetry performance did not improve with increasing adaptation time in healthy participants or patients with choroideremia after ambient light exposure. After bright light exposure, we found microperimetry thresholds improved after 10 min of adaptation, but did not improve further at 20 min.ConclusionMesopic adaptation is not required before MAIA microperimetry after exposure to ambient light. Ten minutes of adaptation is sufficient after exposure to a bright light stimulus, such as ophthalmoscopy or retinal imaging. The brief time of dark adaptation required corresponds to cone adaptation curves and provides further evidence for cone-mediated central retinal function under mesopic conditions.
Collapse
|
32
|
Mesopic and dark-adapted two-color fundus-controlled perimetry in patients with cuticular, reticular, and soft drusen. Eye (Lond) 2018; 32:1819-1830. [PMID: 30068928 DOI: 10.1038/s41433-018-0183-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 05/22/2018] [Accepted: 06/19/2018] [Indexed: 12/19/2022] Open
Abstract
PURPOSE To examine the feasibility and utility of dark-adapted two-color fundus-controlled perimetry (FCP) in patients with cuticular, reticular, and soft drusen, and to compare FCP data to microstructural spectral-domain optical coherence tomography (SD-OCT) data. METHODS Forty-four eyes (24 eyes of 24 patients with drusen, age 69.4 ± 12.6 years; 20 normal eyes of 16 subjects, 61.7 ± 12.4 years) underwent duplicate mesopic, dark-adapted cyan and dark-adapted red FCP within 14° of the central retina (total of 12 936 threshold tests) using the Scotopic Macular Integrity Assessment (S-MAIA, CenterVue, Padova, Italy) device. FCP data were registered to SD-OCT data to obtain outer nuclear layer, inner and outer photoreceptor segment, and retinal pigment epithelium drusen complex (RPEDC) thickness data spatially corresponding to the stimulus location and area (0.43°). Structure-function correlations were assessed using mixed-effects models. RESULTS Mean deviation values for eyes with cuticular, soft, and reticular drusen were similar for mesopic (-2.1, -3.4, and -3.6 dB) and dark-adapted red (-1.4, -2.6, and -3.3 dB) FCP. For the dark-adapted cyan FCP (0.1, -1.9, and -5.0 dB) and for the cyan-red sensitivity difference (+1.0, +0.5, and -2.4 dB), the mean deviation values differed significantly in dependence of the predominant drusen type (one-way ANOVA; p < 0.05). RPEDC thickness was associated with reduction of mesopic sensitivity (-0.34 dB/10 µm RPEDC thickening; p < 0.001), dark-adapted cyan sensitivity (-0.11 dB/10 µm RPEDC thickening; p = 0.003), and dark-adapted red sensitivity (-0.26 dB/10 µm RPEDC thickening; p < 0.001). CONCLUSIONS In contrast to mesopic FCP, dark-adapted two-color FCP allowed for meaningful differential testing of rod and cone function in patients with drusen indicating predominant cone dysfunction in eyes with cuticular drusen and predominant rod dysfunction in eyes with reticular drusen. RPEDC thickness was the strongest predictor of the evaluated SD-OCT biomarkers for point-wise sensitivity.
Collapse
|