Iselin KC, Bachmann LM, Thiel MA, Sanak F, Baenninger PB, Kaufmann C. A fluorophotometric comparison of anterior chamber riboflavin delivery via corneal application and fornix instillation.
ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023;
98:627-632. [PMID:
37748681 DOI:
10.1016/j.oftale.2023.09.002]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 08/09/2023] [Indexed: 09/27/2023]
Abstract
INTRODUCTION AND OBJECTIVES
We investigated whether riboflavin self-administration by patients could be a feasible option for corneal cross-linking, given the considerable resources required to impregnate the cornea with riboflavin. We analysed whether administering riboflavin in the inferior fornix (the site of self-administration) results in non-inferior riboflavin concentrations as when applied directly on the cornea (the site of administration by medical personnel).
PATIENTS AND METHODS
We conducted a prospective study to evaluate riboflavin concentrations at six time-points (baseline, 5, 15, 30, 45 and 60min) in 18 healthy volunteers for each of two application sites: cornea and fornix. Anterior chamber riboflavin (Peschke® TE 0.25%) concentrations were measured by fluorophotometry (Fluorotron™ Master FM-2).
RESULTS
For the two application sites cornea and fornix, participants did not differ in terms of age and sex. At baseline, the autofluorescence in the anterior chamber was 16.7ng/mL (SD 5.5) and 14.6ng/mL (SD 4.6) (P=.221). After 30min, anterior chamber fluorescein concentrations had risen to 55.1ng/mL (SD 25.5) and 46.1ng/mL (SD 25.1) (P=.293) without a further relevant increase by 60min.
CONCLUSIONS
This study found that applying riboflavin drops in the inferior fornix was non-inferior to applying it directly to the cornea, based on fluorophotometric measurements of anterior chamber riboflavin concentrations. This suggests that self-application of riboflavin is feasible in terms of corneal riboflavin impregnation.