1
|
Tarhan M, Meller D, Hammer M. Hyperautofluorescent material inside areas of macular atrophy may reveal non-lipofuscin fluorophores in late stage AMD. Acta Ophthalmol 2025; 103:e66-e75. [PMID: 39177106 PMCID: PMC11704839 DOI: 10.1111/aos.16752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 08/08/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE To characterize fundus autofluorescence (FAF) in complete (cRORA) and incomplete retinal pigment epithelium and outer retinal atrophy (iRORA) by fluorescence lifetime imaging ophthalmology (FLIO). METHODS Overall, 98 macular atrophy (MA) lesions in 42 eyes of 37 age-related macular degeneration (AMD) patients (mean age: 80.9 ± 5.8 years), 25 of them classified as iRORA and 73 as cRORA by OCT, were investigated by FLIO in a short (SSC: 498-560 nm) and a long wavelength channel (LSC: 560-720 nm). Differences of FAF lifetimes and peak emission wavelength (PEW) between atrophic lesions and intact retinal pigment epithelium (RPE) in the outer ring of the ETDRS grid were considered. RESULTS FAF lifetimes in MA were longer and PEW were significantly (p < 0.001) shorter than in intact RPE by 112 ± 78 ps (SSC), 91 ± 64 ps (LSC), 27 ± 18 nm (PEW) in iRORA and by 227 ± 112 ps (SSC), 167 ± 81 ps (LSC), and 54 ± 17 nm (PEW) in cRORA. 37% of iRORA and 24% of cRORA were hyperautofluorescent in SSC. Persistent sub-RPE-BL material in MA was newly found as a hyperautofluorescent entity with lifetimes considerably longer than that of drusen and RPE. CONCLUSIONS Despite RPE and, thus, lipofuscin are greatly absent in MA, considerable FAF, preferably at short wavelengths, was found in those lesions. Drusen, persistent sub-RPE-BL material, basal laminar deposits, persistent activated RPE, and sclera were identified as putative sources of this fluorescence. FLIO can help to characterize respective fluorophores.
Collapse
Affiliation(s)
- Melih Tarhan
- Department of OphthalmologyUniversity Hospital JenaJenaGermany
| | - Daniel Meller
- Department of OphthalmologyUniversity Hospital JenaJenaGermany
| | - Martin Hammer
- Department of OphthalmologyUniversity Hospital JenaJenaGermany
- Department of OphthalmologyUniversity Hospital BonnBonnGermany
- Center for Medical Optics and PhotonicsUniversity of JenaJenaGermany
| |
Collapse
|
2
|
Różanowska MB. Lipofuscin, Its Origin, Properties, and Contribution to Retinal Fluorescence as a Potential Biomarker of Oxidative Damage to the Retina. Antioxidants (Basel) 2023; 12:2111. [PMID: 38136230 PMCID: PMC10740933 DOI: 10.3390/antiox12122111] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/05/2023] [Accepted: 12/09/2023] [Indexed: 12/24/2023] Open
Abstract
Lipofuscin accumulates with age as intracellular fluorescent granules originating from incomplete lysosomal digestion of phagocytosed and autophagocytosed material. The purpose of this review is to provide an update on the current understanding of the role of oxidative stress and/or lysosomal dysfunction in lipofuscin accumulation and its consequences, particularly for retinal pigment epithelium (RPE). Next, the fluorescence of lipofuscin, spectral changes induced by oxidation, and its contribution to retinal fluorescence are discussed. This is followed by reviewing recent developments in fluorescence imaging of the retina and the current evidence on the prognostic value of retinal fluorescence for the progression of age-related macular degeneration (AMD), the major blinding disease affecting elderly people in developed countries. The evidence of lipofuscin oxidation in vivo and the evidence of increased oxidative damage in AMD retina ex vivo lead to the conclusion that imaging of spectral characteristics of lipofuscin fluorescence may serve as a useful biomarker of oxidative damage, which can be helpful in assessing the efficacy of potential antioxidant therapies in retinal degenerations associated with accumulation of lipofuscin and increased oxidative stress. Finally, amendments to currently used fluorescence imaging instruments are suggested to be more sensitive and specific for imaging spectral characteristics of lipofuscin fluorescence.
Collapse
Affiliation(s)
- Małgorzata B. Różanowska
- School of Optometry and Vision Sciences, College of Biomedical and Life Sciences, Cardiff University, Maindy Road, Cardiff CF24 4HQ, Wales, UK;
- Cardiff Institute for Tissue Engineering and Repair (CITER), Redwood Building, King Edward VII Avenue, Cardiff CF10 3NB, Wales, UK
| |
Collapse
|
3
|
Schweitzer D, Haueisen J, Klemm M. Suppression of natural lens fluorescence in fundus autofluorescence measurements: review of hardware solutions. BIOMEDICAL OPTICS EXPRESS 2022; 13:5151-5170. [PMID: 36425615 PMCID: PMC9664869 DOI: 10.1364/boe.462559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/25/2022] [Accepted: 07/25/2022] [Indexed: 06/16/2023]
Abstract
Fluorescence lifetime imaging ophthalmoscopy (FLIO), a technique for investigating metabolic changes in the eye ground, can reveal the first signs of diseases related to metabolism. The fluorescence of the natural lens overlies the fundus fluorescence. Although the influence of natural lens fluorescence can be somewhat decreased with mathematical models, excluding this influence during the measurement by using hardware enables more exact estimation of the fundus fluorescence. Here, we analyze four 1-photon excitation hardware solutions to suppress the influence of natural lens fluorescence: aperture stop separation, confocal scanning laser ophthalmoscopy, combined confocal scanning laser ophthalmoscopy and aperture stop separation, and dual point confocal scanning laser ophthalmoscopy. The effect of each principle is demonstrated in examples. The best suppression is provided by the dual point principle, realized with a confocal scanning laser ophthalmoscope. In this case, in addition to the fluorescence of the whole eye, the fluorescence of the anterior part of the eye is detected from a non-excited spot of the fundus. The intensity and time-resolved fluorescence spectral data of the fundus are derived through the subtraction of the simultaneously measured fluorescence of the excited and non-excited spots. Advantages of future 2-photon fluorescence excitation are also discussed. This study provides the first quantitative evaluation of hardware principles to suppress the fluorescence of the natural lens during measurements of fundus autofluorescence.
Collapse
Affiliation(s)
- D. Schweitzer
- Department of Ophthalmology, University Hospital Jena, Am Klinikum 1, 07747 Jena, Germany
| | - J. Haueisen
- Institute of Biomedical Engineering and Informatics, POB 100565, 98694 Ilmenau, Germany
| | - M. Klemm
- Institute of Biomedical Engineering and Informatics, POB 100565, 98694 Ilmenau, Germany
| |
Collapse
|
4
|
Hammer M, Simon R, Meller D, Klemm M. Combining fluorescence lifetime with spectral information in fluorescence lifetime imaging ophthalmoscopy (FLIO). BIOMEDICAL OPTICS EXPRESS 2022; 13:5483-5494. [PMID: 36425633 PMCID: PMC9664887 DOI: 10.1364/boe.457946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/05/2022] [Accepted: 04/07/2022] [Indexed: 06/01/2023]
Abstract
Fluorescence lifetime imaging ophthalmoscopy (FLIO) provides information on fluorescence lifetimes in two spectral channels as well as the peak emission wavelength (PEW) of the fluorescence. Here, we combine these measures in an integral three-dimensional lifetime-PEW metric vector and determine a normal range for this vector from measurements in young healthy subjects. While for these control subjects 97 (±8) % (median (interquartile range)) of all para-macular pixels were covered by this normal vector range, it was 67 (±55) % for the elderly healthy, 38 (±43) % for age-related macular degeneration (AMD)-suspect subjects, and only 6 (±4) % for AMD patients. The vectors were significantly different for retinal pigment epithelium (RPE) lesions in AMD patients from that of non-affected tissue (p < 0.001). Lifetime- PEW plots allowed to identify possibly pathologic fundus areas by fluorescence parameters outside a 95% quantile per subject. In a patient follow-up, changes in fluorescence parameters could be traced in the lifetime-PEW metric, showing their change over disease progression.
Collapse
Affiliation(s)
- Martin Hammer
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
- Center for Medical Optics and Photonics, Univ. of Jena, Jena, Germany
| | - Rowena Simon
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Daniel Meller
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Matthias Klemm
- Institute of Biomedical Engineering and Informatics, Technical Univ. Ilmenau, Ilmenau, Germany
| |
Collapse
|
5
|
Simon R, Brauer JL, Meller D, Hammer M. Impact of cataract on the spectral measurement of fundus autofluorescence. Graefes Arch Clin Exp Ophthalmol 2022; 260:2057-2059. [PMID: 35020017 PMCID: PMC9061646 DOI: 10.1007/s00417-022-05554-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/30/2021] [Accepted: 01/04/2022] [Indexed: 11/29/2022] Open
Affiliation(s)
- Rowena Simon
- Department of Ophthalmology, University Hospital Jena, Am Klinikum 1, 07747, Jena, Germany
| | - Jakob Lauritz Brauer
- Department of Ophthalmology, University Hospital Jena, Am Klinikum 1, 07747, Jena, Germany
| | - Daniel Meller
- Department of Ophthalmology, University Hospital Jena, Am Klinikum 1, 07747, Jena, Germany
| | - Martin Hammer
- Department of Ophthalmology, University Hospital Jena, Am Klinikum 1, 07747, Jena, Germany. .,Center for Medical Optics and Photonics, Univ. of Jena, Jena, Germany.
| |
Collapse
|
6
|
Lincke JB, Dysli C, Jaggi D, Fink R, Wolf S, Zinkernagel MS. The Influence of Cataract on Fluorescence Lifetime Imaging Ophthalmoscopy (FLIO). Transl Vis Sci Technol 2021; 10:33. [PMID: 34004011 PMCID: PMC8088233 DOI: 10.1167/tvst.10.4.33] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To investigate the influence of lens opacifications on fluorescence lifetime imaging ophthalmoscopy (FLIO). Methods Forty-seven eyes of 45 patients were included. Mean fluorescence lifetimes (Tm) were recorded with a fluorescence lifetime imaging ophthalmoscope in a short spectral channel (SSC) and a long spectral channel (LSC). Retinal and lens autofluorescence lifetimes were measured in subjects before and after cataract surgery. Lens opacification was graded using the Lens Opacities Classification System III (LOCS III) classification. Results The retinal Tm decreased significantly after cataract surgery in both spectral channels (SSC: -53%, P < 0.0001; LSC: -26%, P = 0.0041). The lens Tm differed significantly between the crystalline and the artificial lens in both spectral channels (P < 0.0001). The "nuclear opacity" and "nuclear color" score of the LOCS III classification correlated significantly with the mean Tm difference in both spectral channels (P < 0.0001). Conclusions Lens opacification results in significantly longer retinal Tm. Therefore the lens status has to be considered when performing cross-sectional fluorescence lifetime analysis. Cataract-formation and cataract-surgery needs to be considered when conducting longitudinal studies. Grading of nuclear opacity following the LOCS III classification provides an approximate conversion formula for the mean change of lifetimes, which can be helpful in the interpretation of data in patients with lens opacities. Translational Relevance FLIO is significantly influenced by lens opacities. Using a lens opacity grading scheme and measuring fluorescence lifetimes before and after cataract surgery, an approximative conversion formula can be calculated, which enables the comparison of lifetimes after cataract surgery or over the course of time.
Collapse
Affiliation(s)
- Joel-Benjamin Lincke
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Chantal Dysli
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Damian Jaggi
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Rahel Fink
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Sebastian Wolf
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Martin S Zinkernagel
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
7
|
Sauer L, Vitale AS, Modersitzki NK, Bernstein PS. Fluorescence lifetime imaging ophthalmoscopy: autofluorescence imaging and beyond. Eye (Lond) 2021; 35:93-109. [PMID: 33268846 PMCID: PMC7852552 DOI: 10.1038/s41433-020-01287-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 10/20/2020] [Accepted: 11/04/2020] [Indexed: 12/14/2022] Open
Abstract
Fluorescence lifetime imaging ophthalmoscopy, FLIO, has gained large interest in the scientific community in the recent years. It is a noninvasive imaging modality that has been shown to provide additional information to conventional imaging modalities. The FLIO device is based on a Heidelberg Engineering Spectralis system. Autofluorescence lifetimes are excited at 473 nm and recorded in two spectral wavelength channels, a short spectral channel (SSC, 498-560 nm) and a long spectral channel (LSC, 560-720 nm). Typically, mean autofluorescence lifetimes in a 30° retinal field are investigated. FLIO shows a clear benefit for imaging different retinal diseases. For example, in age-related macular degeneration (AMD), ring patterns of prolonged FLIO lifetimes 1.5-3.0 mm from the fovea can be appreciated. Macular telangiectasia type 2 (MacTel) shows a different pattern, with prolonged FLIO lifetimes within the typical MacTel zone. In Stargardt disease, retinal flecks can be appreciated even before they are visible with other imaging modalities. Early hydroxychloroquine toxicity appears to be detectable with FLIO. This technique has more potential that has yet to be discovered. This review article focuses on current knowledge as well as pitfalls of this technology. It highlights clinical benefits of FLIO imaging in different ophthalmic and systemic diseases, and provides an outlook with perspectives from the authors.
Collapse
Affiliation(s)
- Lydia Sauer
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Alexandra S Vitale
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Natalie K Modersitzki
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Paul S Bernstein
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA.
| |
Collapse
|