1
|
Hossaini S, Hoffmann C, Cousins S, Blencowe N, McNair AGK, Blazeby JM, Avery KNL, Potter S, Macefield R. Development of a conceptual framework for reporting modifications in surgical innovation: scoping review. BJS Open 2023; 7:7145934. [PMID: 37104755 PMCID: PMC10139440 DOI: 10.1093/bjsopen/zrad020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 01/20/2023] [Accepted: 01/28/2023] [Indexed: 04/29/2023] Open
Abstract
BACKGROUND Innovative surgical procedures and devices are often modified throughout their development and introduction into clinical practice. A systematic approach to reporting modifications may support shared learning and foster safe and transparent innovation. Definitions of 'modifications', and how they are conceptualized and classified so they can be reported and shared effectively, however, are lacking. This study aimed to explore and summarize existing definitions, perceptions, classifications and views on modification reporting to develop a conceptual framework for understanding and reporting modifications. METHODS A scoping review was conducted in accordance with PRISMA Extension for Scoping Reviews (PRISMA-ScR) guidelines. Targeted searches and two database searches were performed to identify relevant opinion pieces and review articles. Included were articles relating to modifications to surgical procedures/devices. Data regarding definitions, perceptions and classifications of modifications, and views on modification reporting were extracted verbatim. Thematic analysis was undertaken to identify themes, which informed development of the conceptual framework. RESULTS Forty-nine articles were included. Eight articles included systems for classifying modifications, but no articles reported an explicit definition of modifications. Some 13 themes relating to perception of modifications were identified. The derived conceptual framework comprises three overarching components: baseline data about modifications, details about modifications and impact/consequences of modifications. CONCLUSION A conceptual framework for understanding and reporting modifications that occur during surgical innovation has been developed. This is a first necessary step to support consistent and transparent reporting of modifications, to facilitate shared learning and incremental innovation of surgical procedures/devices. Testing and operationalization is now needed to realize the value of this framework.
Collapse
Affiliation(s)
- Sina Hossaini
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
| | - Christin Hoffmann
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
| | - Sian Cousins
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
| | - Natalie Blencowe
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
- Department of Gastrointestinal Surgery, North Bristol NHS Trust, Bristol, UK
| | - Angus G K McNair
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
- Department of Gastrointestinal Surgery, North Bristol NHS Trust, Bristol, UK
| | - Jane M Blazeby
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
- Division of Surgery, Bristol Royal Infirmary, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
| | - Kerry N L Avery
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
| | - Shelley Potter
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
- Bristol Breast Care Centre, North Bristol NHS Trust, Bristol, UK
| | - Rhiannon Macefield
- Department of Population Health Sciences, National Institute for Health and Care Research Bristol Biomedical Research Centre, Bristol Centre for Surgical Research, Bristol Medical School, University of Bristol, Bristol, UK
| |
Collapse
|
2
|
Talati IA, Parsa KM, Gao WZ. Recalls of Moderate- and High-Risk Otolaryngologic Devices Approved by the US Food and Drug Administration, 2003-2019. Otolaryngol Head Neck Surg 2022; 167:832-838. [PMID: 35290135 DOI: 10.1177/01945998221085166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE The US Food and Drug Administration (FDA) regulates the marketing of medical devices based on the premarket approval (PMA) or 510(k) pathway. We investigated the relationship among the regulatory pathway of otolaryngologic devices, the number of recalls, and the recall characteristics. STUDY DESIGN Retrospective cross-sectional analysis. SETTING Publicly available FDA databases. METHODS The FDA Ear, Nose, and Throat Devices Panel database was queried for 510(k) clearances and PMA approvals from 1976 to 2019. Device recalls from 2003 to 2019 were reviewed. Devices were then categorized by subspecialty, type, supporting evidence, and PMA supplement type. Logistic regression characterized the odds of recall for each device type and subspeciality. RESULTS A total of 1061 (57.8%) 510(k) and 778 (42.3%) PMA device applications and modifications were approved. There were 120 (11.3%) recall events associated with 42 unique otolaryngologic devices cleared via the 510(k) pathway, as compared with 25 (3.2%) recall events for 5 unique PMA devices. 510(k) device approvals were more likely to be recalled than PMA device approvals (odds ratio, 3.67; 95% CI, 2.38-5.88; P < .0001). 510(k) surgical devices (odds ratio, 2.1; 95% CI, 1.1-4.4; P = .03) were more likely to be recalled than diagnostic devices. Devices designated for laryngology (70.0%) and general otolaryngology (25.0%) composed the majority of recalls. CONCLUSION Otolaryngologic devices approved by the FDA via the 510(k) pathway exhibit a higher number of recalls than the PMA pathway. Given the balance between regulation and facilitating innovation, postmarket surveillance and ongoing regulatory improvements are critical to ensure optimal safety of medical devices.
Collapse
Affiliation(s)
- Ish A Talati
- School of Medicine, Georgetown University, Washington, DC
| | - Keon M Parsa
- MedStar Georgetown University Hospital, Washington, DC
| | - William Z Gao
- MedStar Georgetown University Hospital, Washington, DC
| |
Collapse
|
3
|
Postmarket Modifications of High-risk Plastic Surgery Devices. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2020; 8:e2621. [PMID: 32309074 PMCID: PMC7159931 DOI: 10.1097/gox.0000000000002621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Accepted: 11/19/2019] [Indexed: 12/04/2022]
Abstract
Background: In the United States, high-risk medical devices must be cleared through the premarket approval (PMA) pathway, which requires clinical evidence ensuring safety and efficacy. Approved devices can be modified and reintroduced to market without additional study through the PMA supplemental review track. This study characterizes the changes of high-risk plastic surgery devices once they undergo initial clearance. Methods: A retrospective, cross-sectional analysis of the Food and Drug Administration (FDA) PMA database. The following data were extracted from the PMA database (January 1, 1980 to December 31, 2018): initial clearance date, device type, the number and type of supplement, supplement reason, and product withdrawal date. Data from the FDA medical device recall database were also extracted and reported. The median number of device modifications and median lifetime of device-years were calculated. Results: There have been 39 original plastic surgery devices approved by the FDA. There was no significant change with respect to initial clearance dates for original devices over time (r = 0.28; P = 0.084). PMA supplement usage has significantly increased with time (rs = 0.9174, P = 0.000). Overall, approved plastic surgery devices have undergone a median of 11 changes (IQR, 3–35). Breast implant devices collectively underwent the most modifications with a median of 28 modifications per device (IQR, 20.25–33.25). Conclusions: Over the past 2 decades, plastic surgery device manufacturers have significantly increased the use of supplement track review. High-risk plastic surgery devices may undergo frequent minor changes without clinical evidence to support the safety and efficacy of modified versions.
Collapse
|
4
|
Abstract
Medical devices are essential in the diagnosis and treatment of otolaryngologic disease. The US Food and Drug Administration (FDA) is tasked with assuring the safety and effectiveness of these devices. Otolaryngologists, in turn, are often responsible for helping patients understand risks, benefits, and alternatives when deciding whether to rely on devices in their care. To best counsel patients, otolaryngologists should be aware of the strengths and limitations of device regulation by the FDA. This article reviews the FDA regulatory framework for medical devices, premarket evidentiary standards for marketing devices, and postmarket methods of safety surveillance.
Collapse
Affiliation(s)
- Vinay K Rathi
- Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, USA; Department of Otolaryngology, Harvard Medical School, Boston, MA, USA.
| | - Stacey T Gray
- Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, USA; Department of Otolaryngology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
5
|
Ezaldein HH, Scott JF, Yin ES, Ventura A, DeRuyter NP, Leffell DJ. Transparency and Dermatologic Device Approval by the US Food and Drug Administration. JAMA Dermatol 2018; 154:273-280. [PMID: 29365020 DOI: 10.1001/jamadermatol.2017.5757] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance The US Food and Drug Administration approves Class III medical devices via the premarket approval pathway, often requiring clinical data on safety and efficacy. Manufacturers can submit incremental device changes via supplemental applications, which are not subjected to such vetting measures and can cause understudied changes that lead to drift from a device's original design. Objectives To characterize the postapproval changes to Class III dermatologic devices and to evaluate inconsistencies in the use of the premarket approval pathway. Design, Setting, and Participants This study was a cross-sectional retrospective cohort analysis of a public US Food and Drug Administration database for premarket approval of devices. Included were dermatologic devices approved by the US Food and Drug Administration between January 1, 1980, and November 1, 2016, through the premarket pathway for device approval. Main Outcomes and Measures Original devices were identified, and their supplements were characterized chronologically, by review track, and by modification category. Results The 27 dermatologic devices studied consisted of 14 injectables, 11 photodynamic therapies, a dermal replacement matrix, and a diagnostic imaging instrument. Supplemental applications are increasingly used: the data-requiring panel-track pathway was the least common approach (2.8% [16 of 562 supplements]), while the 30-day track, which does not require clinical data, was most frequently used (42.5% [239 of 562 supplements]). Four devices (14.8%) underwent low-risk recalls (Class II or Class III), and 10 devices (37.0%) were voluntarily withdrawn. Conclusions and Relevance As manufacturers make increasing use of supplemental applications, minor device changes may occur without supporting clinical data, which could pose a safety risk to patients.
Collapse
Affiliation(s)
- Harib H Ezaldein
- Department of Dermatology, Yale School of Medicine, New Haven, Connecticut.,Department of Surgery, University of Washington, Seattle.,Department of Dermatology, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Jeffrey F Scott
- Department of Dermatology, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Emily S Yin
- Department of Dermatology, Yale School of Medicine, New Haven, Connecticut
| | - Alessandra Ventura
- Department of Dermatology, Yale School of Medicine, New Haven, Connecticut.,Dermatology Department, University of Rome Tor Vergata, Rome, Italy
| | | | - David J Leffell
- Department of Dermatology, Yale School of Medicine, New Haven, Connecticut
| |
Collapse
|
6
|
Zheng SY, Dhruva SS, Redberg RF. Characteristics of Clinical Studies Used for US Food and Drug Administration Approval of High-Risk Medical Device Supplements. JAMA 2017; 318:619-625. [PMID: 28810022 PMCID: PMC5817595 DOI: 10.1001/jama.2017.9414] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
IMPORTANCE High-risk medical devices often undergo modifications, which are approved by the US Food and Drug Administration (FDA) through various kinds of premarket approval (PMA) supplements. There have been multiple high-profile recalls of devices approved as PMA supplements. OBJECTIVE To characterize the quality of the clinical studies and data (strength of evidence) used to support FDA approval of panel-track supplements (a type of PMA supplement pathway that is used for significant changes in a device or indication for use and always requires clinical data). DESIGN AND SETTING Descriptive study of clinical studies supporting panel-track supplements approved by the FDA between April 19, 2006, and October 9, 2015. EXPOSURE Panel-track supplement approval. MAIN OUTCOMES AND MEASURES Methodological quality of studies including randomization, blinding, type of controls, clinical vs surrogate primary end points, use of post hoc analyses, and reporting of age and sex. RESULTS Eighty-three clinical studies supported the approval of 78 panel-track supplements, with 71 panel-track supplements (91%) supported by a single study. Of the 83 studies, 37 (45%) were randomized clinical trials and 25 (30%) were blinded. The median number of patients per study was 185 (interquartile range, 75-305), and the median follow-up duration was 180 days (interquartile range, 84-270 days). There were a total of 150 primary end points (mean [SD], 1.8 [1.2] per study), and 57 primary end points (38%) were compared with controls. Of primary end points with controls, 6 (11%) were retrospective controls and 51 (89%) were active controls. One hundred twenty-one primary end points (81%) were surrogate end points. Thirty-three studies (40%) did not report age and 25 (30%) did not report sex for all enrolled patients. The FDA required postapproval studies for 29 of 78 (37%) panel-track supplements. CONCLUSIONS AND RELEVANCE Among clinical studies used to support FDA approval of high-risk medical device modifications, fewer than half were randomized, blinded, or controlled, and most primary outcomes were based on surrogate end points. These findings suggest that the quality of studies and data evaluated to support approval by the FDA of modifications of high-risk devices should be improved.
Collapse
Affiliation(s)
- Sarah Y. Zheng
- Department of Psychiatry, University of California, San Francisco
| | - Sanket S. Dhruva
- Robert Wood Johnson Foundation Clinical Scholars Program, Yale School of Medicine, New Haven, Connecticut
- Veterans Affairs Connecticut Healthcare System, West Haven
| | - Rita F. Redberg
- Division of Cardiology, University of California, San Francisco
| |
Collapse
|
7
|
Incremental Revisions across the Life Span of Ophthalmic Devices after Initial Food and Drug Administration Premarket Approval, 1979-2015. Ophthalmology 2017; 124:1237-1246. [PMID: 28501378 DOI: 10.1016/j.ophtha.2017.03.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 03/17/2017] [Accepted: 03/20/2017] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To characterize the frequency, nature, and regulatory mechanisms by which ophthalmic devices are iteratively modified after initial Food and Drug Administration (FDA) Premarket Approval (PMA). DESIGN Retrospective cross-sectional analysis using publicly available FDA data. PARTICIPANTS Ophthalmic devices initially approved via the FDA's PMA pathway between January 1, 1979 and December 31, 2015. METHODS We used the FDA's PMA Database to identify and characterize initial approvals and subsequent postmarket modifications to Class III ophthalmic devices. The FDA Recalls Database was used to identify associated safety events. MAIN OUTCOME MEASURES Median iterated life span (timespan across which modifications occurred after initial PMA) and median number of supplements approved per device, by device type, and overall, stratified by regulatory pathway and modification type. RESULTS Between 1979 and 2015, the FDA approved 168 original ophthalmic devices via the PMA pathway and 2813 subsequent modifications. More than one third (n = 64; 38%) of original approvals were intraocular lenses. Overall, devices underwent a median of 11 postmarket modifications (interquartile range [IQR], 3-24.8) across a median 10.0-year iterated life span (IQR, 4.1-16.7). The majority of devices (n = 144; 86%) underwent more than 1 postapproval modification, including more than 1 design modification (n = 84; 50%). The median number of changes altering device design or labeling was 3.5 (IQR, 1-9). Although manufacturing alterations (n = 834 of 2813; 30%) were the most frequent type of revision, changes involving device design (n = 667; 24%) and labeling (n = 417; 15%) were common. Recalled devices underwent more frequent postapproval modifications per year (median, 1.4; IQR, 0.7-2.3; mean, 1.5; 95% confidence interval, 1.1-1.9) in the period preceding recall than did nonrecalled devices (median, 0.5; IQR, 0.2-1.1; mean, 0.8; 95% confidence interval, 0.7-1.0) across their market approval period (P < 0.001). CONCLUSIONS Most ophthalmic devices approved via the FDA's PMA pathway have undergone extensive revisions, including serial design and labeling changes, since their initial approvals, often without supporting clinical data. Ophthalmologists should take into consideration that cumulative revisions may render the clinical evidence that supported an original FDA approval less relevant to newer device models.
Collapse
|
8
|
Krouse JH. Highlights from the Current Issue: September 2015. Otolaryngol Head Neck Surg 2015; 153:313-4. [PMID: 26330407 DOI: 10.1177/0194599815596729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- John H Krouse
- Department of Otolaryngology/Head and Neck Surgery, Temple University, Philadelphia, Pennsylvania, USA
| |
Collapse
|