1
|
Ceresa F, Mammana LF, Leonardi A, Palermo A, Patanè F. Virtually Wall-Less versus Standard Thin-Wall Venous Cannula in the Minimally Invasive Mitral Valve Surgery: Single-Center Experience. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1221. [PMID: 37512033 PMCID: PMC10386038 DOI: 10.3390/medicina59071221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 06/15/2023] [Accepted: 06/26/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: Minimally invasive cardiac surgery (MICS) has been developing since 1996. Peripheral cannulation is required to perform MICS, and good venous drainage and a bloodless field are crucial for the success of this procedure. We assessed the benefits of using a virtually wall-less cannula in comparison with the standard thin-wall cannula in clinical practice. Materials and Methods: Between January 2021 and December 2022, we evaluated 65 elective patients, who underwent isolated minimally invasive mitral valve surgery. Both the virtually wall-less and the thin-wall cannulas were placed through a surgical cut-down. Patients' characteristics at baseline were similar in the two groups, except for the body surface area (BSA), which was greater in the virtually wall-less group compared to the thin-wall one. In the standard group, the size of the cannula was chosen depending on the patient's BSA, and the choice of the Smartcannula was based on their height. Results: There were no significant differences between the two groups in terms of negative pressure applied, target flow achieved, hemolysis, the need for blood transfusion, and the post-operative increases in liver and renal enzymes. However, in all the patients, the estimated target flow was achieved, thereby showing the better hemodynamic performance of the virtually wall-less cannula, since, in this group, the patients' BSA was significantly greater compared to the thin-wall group. Ultimately, the mean cross-clamp time, as an indirect index of the effectiveness of the venous drainage, is shorter in the virtually wall-less group compared with the thin-wall group. Conclusions: The virtually wall-less cannula should be preferred in minimally invasive mitral valve surgery due to its superior performance in terms of venous drainage compared with the standard thin-wall cannula.
Collapse
Affiliation(s)
- Fabrizio Ceresa
- Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy
| | | | - Aurora Leonardi
- Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy
| | - Augusto Palermo
- Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy
| | - Francesco Patanè
- Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy
| |
Collapse
|
2
|
Van Praet KM, Kofler M, Meyer A, Sündermann SH, Hommel M, Falk V, Kempfert J. Single-Center Experience With a Self-Expandable Venous Cannula During Minimally Invasive Cardiac Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2022; 17:491-498. [PMID: 36314445 DOI: 10.1177/15569845221131534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
OBJECTIVE Venous drainage is often problematic in minimally invasive cardiac surgery (MICS). Here, we describe our experience with a self-expandable stent cannula designed to optimize venous drainage. METHODS The smart canula® was used in 58 consecutive patients undergoing MICS for mitral valve disease (n = 40), left atrial myxoma (n = 3), left ventricular outflow tract obstruction (n = 1), and aortic valve replacement via a right anterior minithoracotomy (n = 14) procedures. The venous cannula was placed under transesophageal echocardiography guidance to reach the superior vena cava. Vacuum-assisted venous drainage (between -20 and -35 mm Hg) was used to reach a target flow index of 2.2 L/min/m² at a core temperature of 34 °C using a goal-directed perfusion strategy aimed at a minimum DO2 of 272 mL/min/m2. Cardiopulmonary bypass (CPB) parameters were recorded, and hemolysis-related parameters were analyzed on postoperative days 1 to 7. RESULTS Mean body surface area and median body mass index were 1.9 ± 0.2 m2 and 25.2 (23.4, 30.2) kg/m2. Mean CPB and median cross-clamping times were 107.7 ± 24.4 min and 64.5 (53, 75.8) min, and median CPB flow during cardioplegic arrest was 4 (3.6, 4.2) L/min (median cardiac index 2.1 [2, 2.2] L/min/m²). Venous drainage was considered sufficient by the surgeon in all cases, and insertion and removal were uncomplicated. Mean SvO2 during CPB was 80.2% ± 5.5%, and median peak lactate was 10 (8, 14) mg/dL, indicating sufficient perfusion. Mean venous negative drainage pressure during cross-clamping was 27.2 ± 12.3 mm Hg. Platelets dropped by 73.6 ± 37.5 K/µL, lactate dehydrogenase rose by 81.5 (44.3, 140.8) U/L, and leukocytes rose by 3.4 (2.2, 7.2) K/µL on postoperative day 1. CONCLUSIONS The venous smart canula® allows for optimal venous drainage at low negative drainage pressures, facilitating sufficient perfusion in MICS.
Collapse
Affiliation(s)
- Karel M Van Praet
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany
| | - Markus Kofler
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany
| | - Alexander Meyer
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Germany.,Berlin Institute of Health, Germany
| | - Simon H Sündermann
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany.,Department of Cardiovascular Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany
| | - Matthias Hommel
- Institute for Anesthesiology, German Heart Center Berlin, Germany
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany.,Department of Cardiovascular Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany.,Translational Cardiovascular Technologies, Institute of Translational Medicine, Department of Health Sciences and Technology, Swiss Federal Institute of Technology (ETH) Zurich, Switzerland
| | - Jörg Kempfert
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany
| |
Collapse
|
3
|
Hugenroth K, Neidlin M, Engelmann UM, Kaufmann TAS, Steinseifer U, Heilmann T. Tipless transseptal cannula concept combines improved hemodynamic properties and risk-reduced placement: An in silico proof-of-concept. Artif Organs 2021; 45:1024-1035. [PMID: 33851427 DOI: 10.1111/aor.13964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 03/17/2021] [Accepted: 04/06/2021] [Indexed: 11/30/2022]
Abstract
As a leading cause of death worldwide, heart failure is a serious medical condition in which many critically ill patients require temporary mechanical circulatory support (MCS) as a bridge-to-recovery or bridge-to-decision. In many cases, the TandemHeart system is used to unload the left heart by draining blood from the left atrium (LA) to the femoral artery via a transseptal multistage cannula. However, even though the correct positioning of the cannula is crucial for a safe treatment, the long cannula tip currently used in transseptal cannulas complicates positioning, making the cannula vulnerable to displacement during MCS. To overcome these limitations, we propose the development of a new tipless transseptal cannula with improved hemodynamic properties. We discuss the tipless cannula concept by comparing it to the common multistage cannula concept using computational fluid dynamics simulations and assess the flow field in the LA, the wall shear stresses (WSS), and the pressure loss. Across the two distinct time points of end-systole and end-diastole and two drainage flow rates of 3.5 and 5.0 L/min, we find a more homogeneous inlet flow pattern for the tipless cannula concept, accompanied by a remarkably reduced area of platelet-activating WSS (up to 10-times smaller area compared to the multistage cannula). Moreover, pressure loss is up to 14.5% lower in the tipless cannula concept, confirming overall improved hemodynamic properties of the tipless cannula concept. Finally, a diameter-dependent study reveals that lower WSS and pressure losses can be further reduced by large-lumen designs for any simulation setting. Overall, our results suggest that a tipless cannula concept remedies the crucial disadvantages of a long-tip multistage cannula by reducing the risk of misplacement, and it furthermore promotes optimized hemodynamics. With this successful proof-of-concept, we underscore the potential for and encourage the realization of further experimental investigations regarding the development of a tipless transseptal cannula for MCS.
Collapse
Affiliation(s)
- Kristin Hugenroth
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany.,enmodes GmbH, Aachen, Germany
| | - Michael Neidlin
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany
| | - Ulrich M Engelmann
- enmodes GmbH, Aachen, Germany.,Department of Medical Engineering and Applied Mathematics, FH Aachen University of Applied Sciences, Aachen, Germany
| | - Tim A S Kaufmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany.,enmodes GmbH, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Faculty of Medicine, RWTH Aachen University, Aachen, Germany
| | | |
Collapse
|
4
|
Rauh P, Benk C, Beyersdorf F, Russe M. Determination of local flow ratios and velocities in a femoral venous cannula with computational fluid dynamics and 4D flow-sensitive magnetic resonance imaging: A method validation. Artif Organs 2020; 45:506-515. [PMID: 33185904 DOI: 10.1111/aor.13859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 09/09/2020] [Accepted: 10/08/2020] [Indexed: 11/28/2022]
Abstract
Cannulas with multi-staged side holes are the method of choice for femoral cannulation in extracorporeal therapies today. A variety of differently designed products is available on the market. While the preferred tool for the performance assessment of such cannulas are pressure-flow curves, little is known about the flow and velocity distribution. Within this work flow and velocity patterns of a femoral venous cannula with multi-staged side holes were investigated. A mock circulation loop for cannula performance evaluation was built and reproduced using a computer-aided design system. With computational fluid dynamics, volume flows and fluid velocities were determined quantitatively and visually with hole-based precision. In order to ensure the correctness of the flow simulation, the results were subsequently validated by determining the same parameters with four-dimensional flow-sensitive magnetic resonance imaging. Measurement data and numerical solution differed 7% on average throughout the data set for the examined parameters. The highest inflow and velocity were detected at the most proximal holes, where half of the total volume flow enters the cannula. At every hole stage a Y-shaped inflow profile was detected, forming a centered stream in the middle of the cannula. Simultaneously, flow separation creates zones with significant lower flow velocities. Numerical simulation, validated with four-dimensional flow-sensitive magnetic resonance imaging, is a valuable tool to examine flow and velocity distributions of femoral venous cannulas with hole-based accuracy. Flow and velocity distribution in such cannulas are not ideal. Based on this work future cannulas can be effectively optimized.
Collapse
Affiliation(s)
- Patrick Rauh
- Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Research & Development, Xenios AG, Heilbronn, Germany
| | - Christoph Benk
- Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Department of Cardiovascular Surgery, Heart Center University Freiburg, Freiburg, Germany
| | - Friedhelm Beyersdorf
- Faculty of Medicine, University of Freiburg, Freiburg, Germany.,Department of Cardiovascular Surgery, Heart Center University Freiburg, Freiburg, Germany
| | - Maximilian Russe
- Department of Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
5
|
Goto T, Tanabe T, Inamura T, Shirota M, Fumoto K, Saito Y, Fukuda W, Fukuda I, Daitoku K, Minakawa M. Effect of inflow cannula side-hole number on drainage flow characteristics: flow dynamic analysis using numerical simulation. Perfusion 2018; 33:649-655. [DOI: 10.1177/0267659118782246] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: Venous drainage in cardiopulmonary bypass is a very important factor for safe cardiac surgery. However, the ideal shape of venous drainage cannula has not been determined. In the present study, we evaluated the effect of side-hole number under fixed total area and venous drainage flow to elucidate the effect of increasing the side-hole numbers. Method: Computed simulation of venous drainage was performed. Cannulas were divided into six models: an end-hole model (EH) and models containing four (4SH), six (6SH), eight (8SH), 10 (10SH) or 12 side-holes (12SH). Total orifice area of the side-holes was fixed to 120 mm2 on each side-hole cannula. The end-hole orifice area was 36.3 mm2. The total area of the side-holes was kept constant when the number of side-holes was increased. Result: The mean venous drainage flow rate of the EH, 4SH, 6SH, 8SH, 10SH and 12SH was 2.57, 2.52, 2.51, 2.50, 2.49, 2.41 L/min, respectively. The mean flow rate decreased in accordance with the increased number of side-holes. Conclusion: We speculate that flow separation at the most proximal site of the side-hole induces stagnation of flow and induces energy loss. This flow separation may hamper the main stream from the end-hole inlet, which is most effective with low shear stress. The EH cannula was associated with the best flow rate and flow profile. However, by increasing side-hole numbers, flow separation occurs on each side-hole, resulting in more energy loss than the EH cannula and flow rate reduction.
Collapse
Affiliation(s)
- Takeshi Goto
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
| | - Tsubasa Tanabe
- Department of Intelligent Machines and System Engineering, Faculty of Science and Technology, Hirosaki University, Hirosaki, Japan
| | - Takao Inamura
- Department of Intelligent Machines and System Engineering, Faculty of Science and Technology, Hirosaki University, Hirosaki, Japan
| | - Minori Shirota
- Department of Intelligent Machines and System Engineering, Faculty of Science and Technology, Hirosaki University, Hirosaki, Japan
| | - Koji Fumoto
- Department of Mechanical Engineering, College of Science and Engineering, Aoyama Gakuin University, Kanagawa, Japan
| | - Yoshiaki Saito
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
| | - Wakako Fukuda
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
| | - Ikuo Fukuda
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
| | - Kazuyuki Daitoku
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
| | - Masahito Minakawa
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
| |
Collapse
|
6
|
von Segesser LK, Berdajs D, Abdel-Sayed S, Tozzi P, Ferrari E, Maisano F. New, Virtually Wall-Less Cannulas Designed for Augmented Venous Drainage in Minimally Invasive Cardiac Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2016. [DOI: 10.1177/155698451601100408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
| | | | | | | | | | - Francesco Maisano
- Department of Cardiovascular Surgery, University Hospital, Zurich, Switzerland
| |
Collapse
|
7
|
New, Virtually Wall-Less Cannulas Designed for Augmented Venous Drainage in Minimally Invasive Cardiac Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2016; 11:278-81. [DOI: 10.1097/imi.0000000000000283] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Objective Inadequate venous drainage during minimally invasive cardiac surgery becomes most evident when the blood trapped in the pulmonary circulation floods the surgical field. The present study was designed to assess the in vivo performance of new, thinner, virtually wall-less, venous cannulas designed for augmented venous drainage in comparison to traditional thin-wall cannulas. Methods Remote cannulation was realized in 5 bovine experiments (74.0 ± 2.4 kg) with percutaneous venous access over the wire, serial dilation up to 18 F and insertion of either traditional 19 F thin wall, wire-wound cannulas, or through the same access channel, new, thinner, virtually wall-less, braided cannulas designed for augmented venous drainage. A standard minimal extracorporeal circuit set with a centrifugal pump and a hollow fiber membrane oxygenator, but no inline reservoir was used. One hundred fifty pairs of pump-flow and required pump inlet pressure values were recorded with calibrated pressure transducers and a flowmeter calibrated by a volumetric tank and timer at increasing pump speed from 1500 RPM to 3500 RPM (500-RPM increments). Results Pump flow accounted for 1.73 ± 0.85 l/min for wall-less versus 1.17 ± 0.45 l/min for thin wall at 1500 RPM, 3.91 ± 0.86 versus 3.23 ± 0.66 at 2500 RPM, 5.82 ± 1.05 versus 4.96 ± 0.81 at 3500 RPM. Pump inlet pressure accounted for 9.6 ± 9.7 mm Hg versus 4.2 ± 18.8 mm Hg for 1500 RPM, −42.4 ± 26.7 versus −123 ± 51.1 at 2500 RPM, and −126.7 ± 55.3 versus −313 ±116.7 for 3500 RPM. Conclusions At the well-accepted pump inlet pressure of −80 mm Hg, the new, thinner, virtually wall-less, braided cannulas provide unmatched venous drainage in vivo. Early clinical analyses have confirmed these findings.
Collapse
|
8
|
Influence of Aortic Outflow Cannula Orientation on Epiaortic Flow Pattern During Pulsed Cardiopulmonary Bypass. J Med Biol Eng 2015. [DOI: 10.1007/s40846-015-0053-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
9
|
Leckey CAC, Hinders MK. Newtonian viscous effects in ultrasonic emboli removal from blood. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:1340-1349. [PMID: 21684063 DOI: 10.1016/j.ultrasmedbio.2011.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2010] [Revised: 05/04/2011] [Accepted: 05/09/2011] [Indexed: 05/30/2023]
Abstract
We have modeled the removal of emboli from cardiopulmonary bypass circuits via acoustic radiation force. Unless removed, emboli can result in cognitive deficit for those undergoing heart surgery with the use of extracorporeal circuits. There are a variety of mathematical formulations in the literature describing acoustic radiation force, but a lingering question that remains is how important viscosity of the blood and/or embolus is to the process. We implemented both inviscid and viscous models for acoustic radiation force on a sphere immersed in a fluid. We found that for this specific application, the inviscid model seems to be sufficient for predicting acoustic force upon emboli when compared with the chosen viscous model. Thus, the much simpler inviscid model could be used to optimize experimental techniques for ultrasonic emboli removal.
Collapse
|
10
|
|
11
|
Computational fluid dynamics analysis of thrombosis potential in left ventricular assist device drainage cannulae. ASAIO J 2010; 56:157-63. [PMID: 20400890 DOI: 10.1097/mat.0b013e3181d861f1] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Cannulation is necessary when blood is removed from the body, for example in hemodialysis, cardiopulmonary bypass, blood oxygenators, and ventricular assist devices. Artificial blood contacting surfaces are prone to thrombosis, especially in the presence of stagnant or recirculating flow. In this work, computational fluid dynamics was used to investigate the blood flow fields in three clinically available cannulae (Medtronic DLP 12, 16, and 24 F), used as drainage for pediatric circulatory support and to calculate parameters that may be indicative of thrombosis potential. The results show that using the 24 F cannula below flow rates of about 0.75 L/min produces hemodynamic conditions, which may increase the risk of blood clotting within the cannula. No reasons are indicated for not using the 12 or 16 F cannulae with flow rates between 0.25 and 3.0 L/min.
Collapse
|