1
|
Alikhani B, Renne J, Maschke S, Hinrichs JB, Wacker FK, Werncke T. Impact of Patient Alignment on Image Quality in C-Arm Computed Tomography - Evaluation Using an ACR Phantom. ROFO-FORTSCHR RONTG 2020; 193:417-426. [PMID: 32882728 DOI: 10.1055/a-1238-2802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate the influence of patient alignment and thereby heel effect on the image quality (IQ) of C-arm flat-panel detector computed tomography (CACT). MATERIALS AND METHODS An ACR phantom placed in opposite directions along the z-axis (setup A and B) on the patient support was imaged using CACT. Image acquisition was performed with three different image acquisition protocols. The images were reconstructed with four convolution kernels. IQ was assessed in terms of high contrast using the modulation transfer function (MTF) and low contrast by assessing the image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) as well as the reliability of density measurements. Furthermore, the dose intensity profiles were measured free-in-air. RESULTS The MTF in setup B is higher than the MTF measured in setup A (p < 0.01). The image noises measured in setup A for the air and bone inserts were higher compared to those measured in setup B (p > 0.05). Opposite behavior has been observed for the polyethylene, water-equivalent and acrylic inserts. The SNR for all inserts is inversely related to the image noise. A systematically increasing or decreasing trend of CNR could not be observed (p > 0.05). The intensity profile measured by the detector system free-in-air showed that the anode heel effect is perpendicular to the z-axis. CONCLUSION The patient alignment has a minor influence on the IQ of CACT. This effect is not based on the X-ray anode heel effect but is caused mainly by the non-symmetrical rotation of CACT. KEY POINTS · The impact of patient alignment and thereby the heel effect on the image quality of CACT was analyzed.. · The patient alignment has a minor influence on the physical parameters related to image quality, such as noise, SNR, and MTF.. · This effect is based mainly on the non-symmetrical rotation of CACT.. CITATION FORMAT · Alikhani B, Renne J, Maschke S et al. Impact of Patient Alignment on Image Quality in C-Arm Computed Tomography - Evaluation Using an ACR Phantom. Fortschr Röntgenstr 2021; 193: 417 - 426.
Collapse
Affiliation(s)
- Babak Alikhani
- Center for Radiology and Nuclear Medicine, DIAKOVERE Hospital gGmbH, Hannover, Germany
| | - Julius Renne
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Sabine Maschke
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Jan B Hinrichs
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Frank K Wacker
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
| | - Thomas Werncke
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
| |
Collapse
|
2
|
Hoelter P, Goelitz P, Lang S, Luecking H, Kalmuenzer B, Struffert T, Doerfler A. Visualization of large vessel occlusion, clot extent, and collateral supply using volume perfusion flat detector computed tomography in acute stroke patients. Acta Radiol 2019; 60:1504-1511. [PMID: 30862169 DOI: 10.1177/0284185119836220] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Philip Hoelter
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| | - Philipp Goelitz
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| | - Stefan Lang
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| | - Hannes Luecking
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| | - Bernd Kalmuenzer
- Department of Neurology, University Hospital Erlangen, Erlangen, Germany
| | - Tobias Struffert
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| | - Arnd Doerfler
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
3
|
Chong BW, Bendok BR, Krishna C, Sattur M, Brown BL, Tawk RG, Miller DA, Rangel-Castilla L, Babiker H, Frakes DH, Theiler A, Cloft H, Kallmes D, Lanzino G. A Multicenter Pilot Study on the Clinical Utility of Computational Modeling for Flow-Diverter Treatment Planning. AJNR Am J Neuroradiol 2019; 40:1759-1765. [PMID: 31558504 PMCID: PMC7028542 DOI: 10.3174/ajnr.a6222] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 08/05/2019] [Indexed: 12/17/2022]
Abstract
BACKGROUND AND PURPOSE Selection of the correct flow-diverter size is critical for cerebral aneurysm treatment success, but it remains challenging due to the interplay of device size, anatomy, and deployment. Current convention does not address these challenges well. The goals of this pilot study were to determine whether computational modeling improves flow-diverter sizing over current convention and to validate simulated deployments. MATERIALS AND METHODS Seven experienced neurosurgeons and interventional neuroradiologists used computational modeling to prospectively plan 19 clinical interventions. In each patient case, physicians simulated 2-4 flow-diverter sizes that were under consideration based on preprocedural imaging. In addition, physicians identified a preferred device size using the current convention. A questionnaire on the impact of computational modeling on the procedure was completed immediately after treatment. Rotational angiography image data were acquired after treatment and compared with flow-diverter simulations to validate the output of the software platform. RESULTS According to questionnaire responses, physicians found the simulations useful for treatment planning, and they increased their confidence in device selection in 94.7% of cases. After viewing the simulations results, physicians selected a device size that was different from the original conventionally planned device size in 63.2% of cases. The average absolute difference between clinical and simulated flow-diverter lengths was 2.1 mm. In 57% of cases, average simulated flow-diverter diameters were within the measurement uncertainty of clinical flow-diverter diameters. CONCLUSIONS Physicians found computational modeling to be an impactful and useful tool for flow-diverter treatment planning. Validation results showed good agreement between simulated and clinical flow-diverter diameters and lengths.
Collapse
Affiliation(s)
- B W Chong
- From the Department of Neurosurgery (B.W.C., B.R.B., C.K., M.S.), Mayo Clinic, Phoenix, Arizona
- Department of Biological and Health Systems Engineering (B.W.C., D.H.F.), Arizona State University, Tempe, Arizona
| | - B R Bendok
- From the Department of Neurosurgery (B.W.C., B.R.B., C.K., M.S.), Mayo Clinic, Phoenix, Arizona
| | - C Krishna
- From the Department of Neurosurgery (B.W.C., B.R.B., C.K., M.S.), Mayo Clinic, Phoenix, Arizona
| | - M Sattur
- From the Department of Neurosurgery (B.W.C., B.R.B., C.K., M.S.), Mayo Clinic, Phoenix, Arizona
| | - B L Brown
- Department of Neurosurgery (B.L.B., R.G.T., D.A.M.), Mayo Clinic, Jacksonville, Florida
| | - R G Tawk
- Department of Neurosurgery (B.L.B., R.G.T., D.A.M.), Mayo Clinic, Jacksonville, Florida
| | - D A Miller
- Department of Neurosurgery (B.L.B., R.G.T., D.A.M.), Mayo Clinic, Jacksonville, Florida
| | - L Rangel-Castilla
- Department of Neurosurgery (L.R.-C., A.T., H.C., D.K., G.L.), Mayo Clinic, Rochester, Minnesota
| | - H Babiker
- Endovantage, LLC (H.B.), Phoenix, Arizona
| | - D H Frakes
- Department of Biological and Health Systems Engineering (B.W.C., D.H.F.), Arizona State University, Tempe, Arizona
| | - A Theiler
- Department of Neurosurgery (L.R.-C., A.T., H.C., D.K., G.L.), Mayo Clinic, Rochester, Minnesota
| | - H Cloft
- Department of Neurosurgery (L.R.-C., A.T., H.C., D.K., G.L.), Mayo Clinic, Rochester, Minnesota
| | - D Kallmes
- Department of Neurosurgery (L.R.-C., A.T., H.C., D.K., G.L.), Mayo Clinic, Rochester, Minnesota
| | - G Lanzino
- Department of Neurosurgery (L.R.-C., A.T., H.C., D.K., G.L.), Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
4
|
Editor's Highlight: Pulmonary Vascular Thrombosis in Rats Exposed to Inhaled Sulfur Mustard. Toxicol Sci 2018; 159:461-469. [PMID: 28962529 DOI: 10.1093/toxsci/kfx151] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Sulfur mustard (SM) is a chemical warfare agent. When inhaled, SM causes significant injury to the respiratory tract. Although the mechanism involved in acute airway injury after SM inhalation has been well described previously, the mechanism of SM's contribution to distal lung vascular injury is not well understood. We hypothesized that acute inhalation of vaporized SM causes activated systemic coagulation with subsequent pulmonary vascular thrombi formation after SM inhalation exposure. Sprague Dawley rats inhaled SM ethanolic vapor (3.8 mg/kg). Barium/gelatin CT pulmonary angiograms were performed to assess for pulmonary vascular thrombi burden. Lung immunohistochemistry was performed for common procoagulant markers including fibrin(ogen), von Willebrand factor, and CD42d in control and SM-exposed lungs. Additionally, systemic levels of d-dimer and platelet aggregometry after adenosine diphosphate- and thrombin-stimulation were measured in plasma after SM exposure. In SM-exposed lungs, chest CT angiography demonstrated a significant decrease in the distal pulmonary vessel density assessed at 6 h postexposure. Immunohistochemistry also demonstrated increased intravascular fibrin(ogen), vascular von Willebrand factor, and platelet CD42d in the distal pulmonary vessels (<200 µm diameter). Circulating d-dimer levels were significantly increased (p < .001) at 6, 9, and 12 h after SM inhalation versus controls. Platelet aggregation was also increased in both adenosine diphosphate - (p < .01) and thrombin- (p < .001) stimulated platelet-rich plasma after SM inhalation. Significant pulmonary vascular thrombi formation was evident in distal pulmonary arterioles following SM inhalation in rats assessed by CT angiography and immunohistochemistry. Enhanced systemic platelet aggregation and activated systemic coagulation with subsequent thrombi formation likely contributed to pulmonary vessel occlusion.
Collapse
|