1
|
Ma Q, Wang J, Xu D, Zhu C, Qin J, Wu Y, Gao Y, Zhang C. Automatic Breast Volume Scanner and B-Ultrasound-Based Radiomics Nomogram for Clinician Management of BI-RADS 4A Lesions. Acad Radiol 2023; 30:1628-1637. [PMID: 36456445 DOI: 10.1016/j.acra.2022.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 10/17/2022] [Accepted: 11/01/2022] [Indexed: 11/29/2022]
Abstract
RATIONALE AND OBJECTIVES To develop and validate a nomogram for predicting the risk of malignancy of breast imaging reporting and data system (BI-RADS) 4A lesions to reduce unnecessary invasive examinations. MATERIALS AND METHODS From January 2017 to July 2021, 190 cases of 4A lesions included in this study were divided into training and validation sets in a ratio of 8:2. Radiomics features were extracted from sonograms by Automatic Breast Volume Scanner (ABVS) and B-ultrasound. We constructed the radiomics model and calculated the rad-scores. Univariate and multivariate logistic regressions were used to assess demographics and lesion elastography values (virtual touch tissue image, shear wave velocity) and to develop clinical model. A clinical radiomics model was developed using rad-score and independent clinical factors, and a nomogram was plotted. Nomogram performance was evaluated using discrimination, calibration, and clinical utility. RESULTS The nomogram included rad-score, age, and elastography, and showed good calibration. In the training set, the area under the receiver operating characteristic curve (AUC) of the clinical radiomics model (0.900, 95% confidence interval (CI): 0.843-0.958) was superior to that of the radiomics model (0.860, 95% CI: 0.799-0.921) and clinical model (0.816, 95% CI: 0.735-0.958) (p = 0.024 and 0.008, respectively). The decision curve analysis showed that the clinical radiomics model had the highest net benefit in most threshold probability ranges. CONCLUSION ABVS and B-ultrasound-based radiomics nomograms have satisfactory performance in differentiating benign and malignant 4A lesions. This can help clinicians make an accurate diagnosis of 4A lesions and reduce unnecessary biopsy.
Collapse
Affiliation(s)
- Qianqing Ma
- Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei, AH, P R China
| | - Junli Wang
- Department of Ultrasound, The Second People's Hospital of WuHu, Wuhu, AH P R China
| | - Daojing Xu
- Department of Ultrasound, The Second People's Hospital of WuHu, Wuhu, AH P R China
| | - Chao Zhu
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Hefei, AH, P R China
| | - Jing Qin
- Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei, AH, P R China
| | - Yimin Wu
- Department of Ultrasound, The Second People's Hospital of WuHu, Wuhu, AH P R China
| | - Yankun Gao
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Hefei, AH, P R China
| | - Chaoxue Zhang
- Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei, AH, P R China.
| |
Collapse
|
2
|
Zhao Z, Hou S, Li S, Sheng D, Liu Q, Chang C, Chen J, Li J. Application of Deep Learning to Reduce the Rate of Malignancy Among BI-RADS 4A Breast Lesions Based on Ultrasonography. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:2267-2275. [PMID: 36055860 DOI: 10.1016/j.ultrasmedbio.2022.06.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/31/2022] [Accepted: 06/24/2022] [Indexed: 06/15/2023]
Abstract
The aim of the work described here was to develop an ultrasound (US) image-based deep learning model to reduce the rate of malignancy among breast lesions diagnosed as category 4A of the Breast Imaging-Reporting and Data System (BI-RADS) during the pre-operative US examination. A total of 479 breast lesions diagnosed as BI-RADS 4A in pre-operative US examination were enrolled. There were 362 benign lesions and 117 malignant lesions confirmed by postoperative pathology with a malignancy rate of 24.4%. US images were collected from the database server. They were then randomly divided into training and testing cohorts at a ratio of 4:1. To correctly classify malignant and benign tumors diagnosed as BI-RADS 4A in US, four deep learning models, including MobileNet, DenseNet121, Xception and Inception V3, were developed. The performance of deep learning models was compared using the area under the receiver operating characteristic curve (AUROC), accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Meanwhile, the robustness of the models was evaluated by five-fold cross-validation. Among the four models, the MobileNet model turned to be the optimal model with the best performance in classifying benign and malignant lesions among BI-RADS 4A breast lesions. The AUROC, accuracy, sensitivity, specificity, PPV and NPV of the optimal model in the testing cohort were 0.897, 0.913, 0.926, 0.899, 0.958 and 0.784, respectively. About 14.4% of patients were expected to be upgraded to BI-RADS 4B in US with the assistance of the MobileNet model. The deep learning model MobileNet can help to reduce the rate of malignancy among BI-RADS 4A breast lesions in pre-operative US examinations, which is valuable to clinicians in tailoring treatment for suspicious breast lesions identified on US.
Collapse
Affiliation(s)
- Zhijin Zhao
- Department of Medical Ultrasound, Fudan University Shanghai Cancer Center, Shanghai, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Size Hou
- Department of Applied Mathematics, School of Science, Xi'an Jiaotong-Liverpool University, Suzhou, China
| | - Shuang Li
- International Business School Suzhou, Xi'an Jiaotong-Liverpool University, Suzhou, China
| | - Danli Sheng
- Department of Medical Ultrasound, Fudan University Shanghai Cancer Center, Shanghai, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Qi Liu
- Department of Medical Ultrasound, Fudan University Shanghai Cancer Center, Shanghai, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Cai Chang
- Department of Medical Ultrasound, Fudan University Shanghai Cancer Center, Shanghai, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Jiangang Chen
- Shanghai Key Laboratory of Multidimensional Information Processing, School of Communication & Electronic Engineering, East China Normal University, Shanghai, China; Engineering Research Center of Traditional Chinese Medicine Intelligent Rehabilitation, Ministry of Education, Shanghai, China.
| | - Jiawei Li
- Department of Medical Ultrasound, Fudan University Shanghai Cancer Center, Shanghai, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China.
| |
Collapse
|
3
|
Zackrisson S, Andersson I. The development of breast radiology: the Acta Radiologica perspective. Acta Radiol 2021; 62:1473-1480. [PMID: 34709078 DOI: 10.1177/02841851211050861] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The encouraging results of modern breast cancer care builds on tremendous improvements in diagnostics and therapy during the 20th century. Scandinavian countries have made important footprints in the development of breast diagnostics regarding technical development of imaging, cell and tissue sampling methods and, not least, population screening with mammography. The multimodality approach in combination with multidisciplinary clinical work in breast cancer serve as a role model for the management of many cancer types worldwide. The development of breast radiology is well represented in the research published in this journal and this historical review will describe the most important steps.
Collapse
Affiliation(s)
- Sophia Zackrisson
- Department of Translational Medicine, Diagnostic Radiology, Lund University, Skåne University Hospital Malmö, Malmö, Sweden
| | - Ingvar Andersson
- Department of Translational Medicine, Diagnostic Radiology, Lund University, Unilabs Breast Center, Skåne University Hospital Malmö, Malmö, Sweden
| |
Collapse
|
4
|
Nielsen MB, Søgaard SB, Bech Andersen S, Skjoldbye B, Hansen KL, Rafaelsen S, Nørgaard N, Carlsen JF. Highlights of the development in ultrasound during the last 70 years: A historical review. Acta Radiol 2021; 62:1499-1514. [PMID: 34791887 DOI: 10.1177/02841851211050859] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This review looks at highlights of the development in ultrasound, ranging from interventional ultrasound and Doppler to the newest techniques like contrast-enhanced ultrasound and elastography, and gives reference to some of the valuable articles in Acta Radiologica. Ultrasound equipment is now available in any size and for any purpose, ranging from handheld devices to high-end devices, and the scientific societies include ultrasound professionals of all disciplines publishing guidelines and recommendations. Interventional ultrasound is expanding the field of use of ultrasound-guided interventions into nearly all specialties of medicine, from ultrasound guidance in minimally invasive robotic procedures to simple ultrasound-guided punctures performed by general practitioners. Each medical specialty is urged to define minimum requirements for equipment, education, training, and maintenance of skills, also for medical students. The clinical application of contrast-enhanced ultrasound and elastography is a topic often seen in current research settings.
Collapse
Affiliation(s)
- Michael Bachmann Nielsen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Stinne Byrholdt Søgaard
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Sofie Bech Andersen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Bjørn Skjoldbye
- Department of Radiology, Aleris-Hamlet Hospitals, Copenhagen Denmark
| | - Kristoffer Lindskov Hansen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Søren Rafaelsen
- Department of Radiology, University Hospital of Southern Denmark, Vejle, Denmark
- Faculty of Health Sciences, Institute of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Nis Nørgaard
- Department of Urology, Herlev Gentofte Hospital, Copenhagen, Denmark
| | - Jonathan F. Carlsen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
5
|
Yang Y, Hu Y, Shen S, Jiang X, Gu R, Wang H, Liu F, Mei J, Liang J, Jia H, Liu Q, Gong C. A new nomogram for predicting the malignant diagnosis of Breast Imaging Reporting and Data System (BI-RADS) ultrasonography category 4A lesions in women with dense breast tissue in the diagnostic setting. Quant Imaging Med Surg 2021; 11:3005-3017. [PMID: 34249630 DOI: 10.21037/qims-20-1203] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 03/05/2021] [Indexed: 11/06/2022]
Abstract
Background Biopsy has been recommended for Breast Imaging Reporting and Data System (BI-RADS) category 4 lesions. However, the malignancy rate of category 4A lesions is very low (2-10%). Therefore, most biopsies of category 4A lesions are benign, and the results will generally cause additional health care costs and patient anxiety. Methods A prediction model was developed based on an analysis of 418 BI-RADS ultrasonography (US) category 4A patients at Sun Yat-sen Memorial Hospital. Univariate and multivariate logistic regression analyses were applied to identify significant variables for inclusion in the final nomogram. The predictive accuracy and discriminative ability were evaluated using the concordance index (C-index) and calibration curves. An independent cohort of 97 patients from the Second Affiliated Hospital of Guangzhou Medical University was used for external validation. Results The independent risk factors from the multivariate analysis for the training cohort were family history of breast cancer (OR =4.588, P=0.004), US features [margin (OR =2.916, P=0.019), shape (irregular vs. oval, OR =2.474, P=0.044; round vs. oval, OR =1.935, P=0.276), parallel orientation vs. not parallel (OR =2.204, P=0.040)], low suspicious lymph nodes (OR =7.664, P=0.019), and suspicious calcifications on mammography (MG) (OR =6.736, P=0.001). The C-index was good in the training [0.813, 95% confidence interval (95% CI), 0.733 to 0.893] and validation cohorts (0.765, 95% CI, 0.584 to 0.946). The calibration curves showed optimal agreement between the nomogram prediction and actual observations for the probability of malignancy. Also, the cutoff score was set to 100 for discriminating high and low risk. The model performed well in discerning different risk groups. Conclusions We developed a well-discriminated and calibrated nomogram to predict the malignancy of BI-RADS US category 4A lesions in dense breast tissue, which may help clinicians identify patients at lower or higher risk.
Collapse
Affiliation(s)
- Yaping Yang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yue Hu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Shiyu Shen
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Xiaofang Jiang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ran Gu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Hongli Wang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Fengtao Liu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Jingsi Mei
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Jing Liang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Haixia Jia
- Department of Breast Surgery, Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Qiang Liu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Chang Gong
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Breast Tumor Center, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
6
|
Wang H, Li CY, Zha HL, Xu D, Hu ZB. Diagnostic and Predictive Values of Strain Ratios in the Regions of Interests in Reference Tissue for Breast Tumor. Cancer Manag Res 2021; 13:1017-1028. [PMID: 33574701 PMCID: PMC7871176 DOI: 10.2147/cmar.s292944] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 01/08/2021] [Indexed: 12/23/2022] Open
Abstract
PURPOSE To investigate the diagnostic and predictive value of strain ratios in the regions of interests (ROIs) in reference tissue for breast tumor. PATIENTS AND METHODS A total of 707 lesions in 665 consecutive patients were examined with B-mode Breast Imaging-Reporting and Data System (BI-RADS) and Ultrasonic elastography (UE). Elasticity score (ES) and strain ratio (SR) in each lesion were calculated. Receiver operating characteristic (ROC) curves were used to assess the diagnostic value of BI-RADS, ES, SR1, SR2, BI-RADS combined with ES (BI-RADS+ES), BI-RADS combined with SR1 (BI-RADS+SR1), and BI-RADS combined with SR2 (BI-RADS+SR2). The sensitivity, specificity, and areas under the ROC curves (Az) were obtained. Scatter plots were generated to demonstrate the correlation between SR1 and SR2. Kruskal-Walls H-test, Mann-Whitney U-test and one-way ANOVA were performed to evaluate SRs and tumor-related variables. Multiple linear regression analysis was carried out to determine variables independently associated with SRs. RESULTS BI-RADS had high sensitivity and low specificity in the diagnosis of breast tumor. The specificity of BI-BADS combined with ES or SR was even higher. The Az value of BI-RADS+ES or BI-RADS+SRs was higher than that of BI-RADS (P < 0.001). The Az value of ES was higher than those of SR1 and SR2 (P < 0.001), and those of SR1 and SR2 were similar. SR1 and SR2 were highly positively correlated. There was no statistical difference between Az values of BI-RADS+ES, BI-RADS+SR1, and BI-RADS+SR2. Indistinct margin, high histologic grade, histological type, and negative human epidermal growth factor receptor (Her-2) were associated with SR1 and SR2. Progesterone receptor (PR) status and molecular subtype were associated with SR2. Histologic grade and tumor margin were significantly associated with SR1, and tumor margin was associated with SR2. CONCLUSION SRs in different ROIs in the reference tissue at the same depth showed no different diagnostic value for breast tumor. Both SR1 and SR2 could be useful in assessing the biological characteristics of invasive breast carcinoma.
Collapse
Affiliation(s)
- Hui Wang
- Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, People’s Republic of China
| | - Cui-Ying Li
- Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, People’s Republic of China
| | - Hai-Ling Zha
- Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, People’s Republic of China
| | - Di Xu
- Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, People’s Republic of China
| | - Zhi-Bin Hu
- Department of Epidemiology, Center for Global Health, School of Public Health, Nanjing Medical University, Nanjing, 211166, People’s Republic of China
| |
Collapse
|
7
|
Niu Z, Tian JW, Ran HT, Ren WD, Chang C, Yuan JJ, Kang CS, Deng YB, Wang H, Luo BM, Guo SL, Zhou Q, Xue ES, Zhan WW, Zhou Q, Li J, Zhou P, Zhang CQ, Chen M, Gu Y, Xu JF, Chen W, Zhang YH, Wang HQ, Li JC, Wang HY, Jiang YX. Risk-predicted dual nomograms consisting of clinical and ultrasound factors for downgrading BI-RADS category 4a breast lesions - A multiple centre study. J Cancer 2021; 12:292-304. [PMID: 33391426 PMCID: PMC7738830 DOI: 10.7150/jca.51302] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 10/18/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose: To develop and to validate a risk-predicted nomogram for downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4a breast lesions. Patients and Methods: We enrolled 680 patients with breast lesions that were diagnosed as BI-RADS category 4a by conventional ultrasound from December 2018 to June 2019. All 4a lesions were randomly divided into development and validation groups at the ratio of 3:1. In the development group consisting of 499 cases, the multiple clinical and ultrasound predicted factors were extracted, and dual-predicted nomograms were constructed by multivariable logistic regression analysis, named clinical nomogram and ultrasound nomogram, respectively. Patients were twice classified as either "high risk" or "low risk" in the two nomograms. The performance of these dual nomograms was assessed by an independent validation group of 181 cases. Receiver Operating Characteristic (ROC) curve and diagnostic value were calculated to evaluate the applicability of the new model. Results: After multiple logistic regression analysis, the clinical nomogram included 2 predictors: age and the first-degree family members with breast cancer. The area under the curve (AUC) value for the clinical nomogram was 0.661 and 0.712 for the development and validation groups, respectively. The ultrasound nomogram included 3 independent predictors (margins, calcification and strain ratio), and the AUC value in this nomogram was 0.782 and 0.747 in the development and validation groups, respectively. In the development group of 499 patients, approximately 50.90% (254/499) of patients were twice classified "low risk", with a malignancy rate of 1.18%. In the validation group of 181 patients, approximately 47.51% (86/181) of patients had been twice classified as "low risk", with a malignancy rate of 1.16%. Conclusions: A dual-predicted nomogram incorporating clinical factors and imaging characteristics is an applicable model for downgrading the low-risk lesions in BI-RADS category 4a and shows good stability and accuracy, which is useful for decreasing the rate of invasive examinations and surgery.
Collapse
Affiliation(s)
- Zihan Niu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Jia-Wei Tian
- Department of Ultrasound, the Second Affiliated Hospital of Harbin Medical University, Harbin 150086, China
| | - Hai-Tao Ran
- Department of Ultrasound, the Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, China; Chongqing Key Laboratory of Ultrasound Molecular Imaging, Chongqing 400010, China
| | - Wei-Dong Ren
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang 110004, China
| | - Cai Chang
- Department of Medical Ultrasound, Fudan University Shanghai Cancer Center & Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China
| | - Jian-Jun Yuan
- Department of Ultrasonography, Henan Provincial People's Hospital, Zhengzhou 450003, China
| | - Chun-Song Kang
- Department of Ultrasound, Shanxi Academy of Medical Science, Dayi Hospital of Shanxi Medical University, Taiyuan 030032, China
| | - You-Bin Deng
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China
| | - Hui Wang
- Department of Ultrasound, China-Japan Union Hospital of Jilin University, Changchun 130033, China
| | - Bao-Ming Luo
- Department of Ultrasound, the Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou 510120, China
| | - Sheng-Lan Guo
- Department of Ultrasonography, First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
| | - Qi Zhou
- Department of Medical Ultrasound, the Second Affiliated Hospital, School of Medicine, Xi'an Jiaotong University, Xi'an 710004, China
| | - En-Sheng Xue
- Department of Ultrasound, Union Hospital of Fujian Medical University, Fujian Institute of Ultrasound Medicine, Fuzhou 350001, China
| | - Wei-Wei Zhan
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University, School of Medicine, Shanghai 200025, China
| | - Qing Zhou
- Department of Ultrasonography, Renmin Hospital of Wuhan University, Wuhan 430060, China
| | - Jie Li
- Department of Ultrasound, Qilu Hospital, Shandong University, Jinan 250012, China
| | - Ping Zhou
- Department of Ultrasound, the Third Xiangya Hospital of Central South University, Changsha 410013, China
| | - Chun-Quan Zhang
- Department of Ultrasound, the Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China
| | - Man Chen
- Department of Ultrasound Medicine, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200336, China
| | - Ying Gu
- Department of Ultrasonography, the Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
| | - Jin-Feng Xu
- Department of Ultrasound, Shenzhen People's Hospital, the Second Clinical Medical College of Jinan University, Shenzhen 518020, China
| | - Wu Chen
- Department of Ultrasound, the First Hospital of Shanxi Medical University, Taiyuan 030001, China
| | - Yu-Hong Zhang
- Department of Ultrasound, the Second Hospital of Dalian Medical University, Dalian 116027, China
| | - Hong-Qiao Wang
- Department of Ultrasound, the Affiliated Hospital of Qingdao University, Qingdao 266003, China
| | - Jian-Chu Li
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Hong-Yan Wang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Yu-Xin Jiang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| |
Collapse
|
8
|
Zhao C, Xiao M, Liu H, Wang M, Wang H, Zhang J, Jiang Y, Zhu Q. Reducing the number of unnecessary biopsies of US-BI-RADS 4a lesions through a deep learning method for residents-in-training: a cross-sectional study. BMJ Open 2020; 10:e035757. [PMID: 32513885 PMCID: PMC7282415 DOI: 10.1136/bmjopen-2019-035757] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVE The aim of the study is to explore the potential value of S-Detect for residents-in-training, a computer-assisted diagnosis system based on deep learning (DL) algorithm. METHODS The study was designed as a cross-sectional study. Routine breast ultrasound examinations were conducted by an experienced radiologist. The ultrasonic images of the lesions were retrospectively assessed by five residents-in-training according to the Breast Imaging Report and Data System (BI-RADS) lexicon, and a dichotomic classification of the lesions was provided by S-Detect. The diagnostic performances of S-Detect and the five residents were measured and compared using the pathological results as the gold standard. The category 4a lesions assessed by the residents were downgraded to possibly benign as classified by S-Detect. The diagnostic performance of the integrated results was compared with the original results of the residents. PARTICIPANTS A total of 195 focal breast lesions were consecutively enrolled, including 82 malignant lesions and 113 benign lesions. RESULTS S-Detect presented higher specificity (77.88%) and area under the curve (AUC) (0.82) than the residents (specificity: 19.47%-48.67%, AUC: 0.62-0.74). A total of 24, 31, 38, 32 and 42 identified as BI-RADS 4a lesions by residents 1, 2, 3, 4 and 5 were downgraded to possibly benign lesions by S-Detect, respectively. Among these downgraded lesions, 24, 28, 35, 30 and 40 lesions were proven to be pathologically benign, respectively. After combining the residents' results with the results of the software in category 4a lesions, the specificity and AUC of the five residents significantly improved (specificity: 46.02%-76.11%, AUC: 0.71-0.85, p<0.001). The intraclass correlation coefficient of the five residents also increased after integration (from 0.480 to 0.643). CONCLUSIONS With the help of the DL software, the specificity, overall diagnostic performance and interobserver agreement of the residents greatly improved. The software can be used as adjunctive tool for residents-in-training, downgrading 4a lesions to possibly benign and reducing unnecessary biopsies.
Collapse
Affiliation(s)
- Chenyang Zhao
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Mengsu Xiao
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - He Liu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Ming Wang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hongyan Wang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jing Zhang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuxin Jiang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Qingli Zhu
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|