• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4600962)   Today's Articles (2119)   Subscriber (49361)
For: Lisson CG, Lisson CS, Kleiner S, Regier M, Beer M, Schmidt SA. Iterative scatter correction for grid-less skeletal radiography allows improved image quality equal to an antiscatter grid in adjunct with dose reduction: a visual grading study of 20 body donors. Acta Radiol 2019;60:735-741. [PMID: 30149748 DOI: 10.1177/0284185118796668] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Number Cited by Other Article(s)
1
Gossye T, Buytaert D, Smeets PV, Morbée L, Vereecke E, Kellens P, Achten E, Bacher K. Evaluation of Virtual Grid processed clinical pelvic radiographs. J Appl Clin Med Phys 2024;25:e14353. [PMID: 38693646 PMCID: PMC11163484 DOI: 10.1002/acm2.14353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/24/2023] [Accepted: 03/13/2024] [Indexed: 05/03/2024]  Open
2
Sayed M, Knapp KM, Fulford J, Heales C, Alqahtani SJ. The impact of X-ray scatter correction software on abdomen radiography in terms of image quality and radiation dose. Radiography (Lond) 2024;30:1125-1135. [PMID: 38797045 DOI: 10.1016/j.radi.2024.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 04/24/2024] [Accepted: 05/13/2024] [Indexed: 05/29/2024]
3
Rossignol J, Bélanger G, Gaudreault D, Therrien AC, Bérubé-Lauziére Y, Fontaine R. Time-of-flight scatter rejection in x-ray radiography. Phys Med Biol 2024;69:055027. [PMID: 38232398 DOI: 10.1088/1361-6560/ad1f85] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 01/17/2024] [Indexed: 01/19/2024]
4
Seeber M, Lederer KA, Rowan C, Strohmayer C, Ludewig E. Image processing setting adaptions according to image dose and radiologist preference can improve image quality in computed radiography of the equine distal limb: A cadaveric study. Vet Radiol Ultrasound 2024;65:19-30. [PMID: 38098240 DOI: 10.1111/vru.13321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 11/19/2023] [Accepted: 11/22/2023] [Indexed: 02/07/2024]  Open
5
Sayed M, Knapp KM, Fulford J, Heales C, Alqahtani SJ. The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review. Eur J Radiol 2023;158:110600. [PMID: 36444818 DOI: 10.1016/j.ejrad.2022.110600] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 10/17/2022] [Accepted: 11/06/2022] [Indexed: 11/18/2022]
6
Lawson M, Qian L, Lau KK, Lau T, Massey D, Badawy M. Efficacy of the scatter correction algorithm in portable chest radiography. Emerg Radiol 2022;29:809-817. [PMID: 35612644 PMCID: PMC9130995 DOI: 10.1007/s10140-022-02063-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 05/17/2022] [Indexed: 11/26/2022]
7
Hansson J, Månsson LG, Båth M. EVALUATION OF VGC ANALYZER BY COMPARISON WITH GOLD STANDARD ROC SOFTWARE AND ANALYSIS OF SIMULATED VISUAL GRADING DATA. RADIATION PROTECTION DOSIMETRY 2021;195:378-390. [PMID: 33940628 PMCID: PMC8507457 DOI: 10.1093/rpd/ncab066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 03/09/2021] [Accepted: 04/03/2021] [Indexed: 06/12/2023]
8
Lisson CG, Lisson CS, Vogele D, Strauss B, Schuetze K, Cintean R, Beer M, Schmidt SA. Improvement of image quality applying iterative scatter correction for grid-less skeletal radiography in trauma room setting. Acta Radiol 2020;61:768-775. [PMID: 31569948 DOI: 10.1177/0284185119878348] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA